產品(49,000+)

INA240A4PWR - 200 V/V Current Sense Amplifier | TI
INA240A4PWR

INA240A4PWR - 200 V/V Current Sense Amplifier | TI

The Texas Instruments INA240A4PWR is a bidirectional, ultra-precise current-sense amplifier with a 200 V/V gain, a -4 V to 80 V common-mode range, and enhanced PWM rejection, housed in an 8-pin TSSOP package. It measures the voltage developed across a shunt resistor and produces a proportional analog output for current monitoring, control, protection, and diagnostics. A current-sense amplifier is an analog signal-conditioning device that converts the small differential voltage across a precision shunt into a larger, measurable voltage. Within the broader hierarchy of amplifier, instrumentation amplifier, signal-conditioning IC, and power-management IC, the INA240 supports high-side or low-side sensing while maintaining operation across negative common-mode voltages. Its -4 V lower limit allows sensing during the flyback interval of solenoid and motor systems. The INA240A4 provides a 200 V/V gain, bidirectional current measurement, and enhanced rejection of PWM-related errors. Its broad -4 V to 80 V common-mode operating range is independent of the device supply, allowing the shunt voltage to be measured without restricting it to the amplifier supply range. The 8-pin TSSOP package supports compact layouts while exposing inputs, supply, reference, output, and ground connections. Operationally, the device accepts a differential shunt voltage and drives an output referenced to ground. The reference input permits output-voltage adjustment or midscale biasing when bidirectional current around zero must be represented. The amplifier architecture is intended to preserve measurement accuracy in systems where high-side conductors carry fast-switching currents and substantial voltage transients. Typical uses include motor and solenoid current monitoring, industrial motor drives, robotics, automotive power systems, battery-management systems, power supplies, and inverter control. In these applications, the amplifier converts shunt differential voltage into a control signal suitable for an analog-to-digital converter, comparator, or motor-control loop. PCB design should prioritize the shunt connection. Keep input traces short, symmetric, and away from high-current switching nodes, then place the input and supply bypass capacitors close to their respective pins. A common-ground reference, stable reference implementation, and careful evaluation of shunt placement are essential for preserving measurement accuracy and common-mode performance. This product page combines the manufacturer’s device description, verified distributor availability information, package details, pin-compatible family options, comparison parameters, and practical PCB guidance to support faster component selection and implementation.

詢價 聯絡我們
INA250A1PW - 36V Bidirectional Current-Sense Amplifier | TI
INA250A1PW

INA250A1PW - 36V Bidirectional Current-Sense Amplifier | TI

The Texas Instruments INA250A1PW is a bidirectional, precision current-sense amplifier with an integrated shunt resistor, a 36 V common-mode range, and a gain of 20 V/V in a 16-pin TSSOP (PW) package. It is designed to measure positive and negative current while the measured conductor operates from 0 V to 36 V, independent of the amplifier supply voltage. The integrated precision shunt removes the external shunt-resistor element while preserving calibrated current measurement. A current-sense amplifier is a specialized instrumentation amplifier that converts the voltage across a current-sensing resistor into a proportional, low-level output voltage. The INA250 belongs to the current-sense amplifier hierarchy, where it supports precision measurement, power monitoring, motor control, industrial instrumentation, and protection systems. Its integrated shunt also reduces board area compared with a discrete shunt-resistor implementation. The device provides bidirectional measurement through an externally applied reference voltage. Positive current can move the output above the reference level, while negative current moves it below that level. This arrangement allows a unidirectional amplifier output to represent both load directions and supports applications that need absolute-value or signed-current information. The 0 V to 36 V common-mode range covers many industrial, automotive-adjacent, power-supply, and motor-system rails. The INA250A1PW uses the A1 gain option, which provides 20 V/V voltage gain. Its voltage-output architecture simplifies connection to analog-to-digital converters, comparators, controllers, and monitoring systems. Because the sensing element is integrated, PCB design must preserve the defined current path and provide adequate copper width and thermal capacity for the intended current level. The TSSOP package is a surface-mount package in the TSSOP-16 family. Typical applications include high-side power-supply monitoring, bidirectional motor-current measurement, industrial control systems, battery current sensing, solenoid monitoring, and electronic protection. In these systems, the amplifier reconstructs a current-proportional voltage that can be digitized or compared with a threshold. System calibration should account for the selected gain, reference voltage, ADC resolution, and the measurement bandwidth required by the load. Design attention should focus on Kelvin routing for the reference connection, filtering around the output when the measured waveform contains high-frequency noise, and thermal verification at maximum continuous current. The integrated shunt is convenient, but PCB copper, vias, pads, and connector geometry can limit practical current and increase temperature rise. Use the manufacturer pin-description table when assigning PCB tracks and the device data sheet for the complete recommended layout. This page combines the manufacturer device description, package and operating information, practical application guidance, replacement criteria, and engineering-oriented design notes. These resources help engineers evaluate the INA250A1PW beyond a basic distributor listing while keeping pin compatibility and measurement accuracy at the center of the selection process.

詢價 聯絡我們
INA250A1PWR - 36V Bidirectional Current-Sense Amplifier | TI (Tape & Reel)
INA250A1PWR

INA250A1PWR - 36V Bidirectional Current-Sense Amplifier | TI (Tape & Reel)

The Texas Instruments INA250A1PWR is a bidirectional, precision current-sense amplifier with an integrated shunt resistor, a 36 V common-mode range, and a gain of 20 V/V in a 16-pin TSSOP (PW) package. It is designed to measure positive and negative current while the measured conductor operates from 0 V to 36 V, independent of the amplifier supply voltage. The integrated precision shunt removes the external shunt-resistor element while preserving calibrated current measurement. A current-sense amplifier is a specialized instrumentation amplifier that converts the voltage across a current-sensing resistor into a proportional, low-level output voltage. The INA250 belongs to the current-sense amplifier hierarchy, where it supports precision measurement, power monitoring, motor control, industrial instrumentation, and protection systems. Its integrated shunt also reduces board area compared with a discrete shunt-resistor implementation. The device provides bidirectional measurement through an externally applied reference voltage. Positive current can move the output above the reference level, while negative current moves it below that level. This arrangement allows a unidirectional amplifier output to represent both load directions and supports applications that need absolute-value or signed-current information. The 0 V to 36 V common-mode range covers many industrial, automotive-adjacent, power-supply, and motor-system rails. The INA250A1PWR uses the A1 gain option, which provides 20 V/V voltage gain. Its voltage-output architecture simplifies connection to analog-to-digital converters, comparators, controllers, and monitoring systems. Because the sensing element is integrated, PCB design must preserve the defined current path and provide adequate copper width and thermal capacity for the intended current level. The TSSOP package is a surface-mount package in the TSSOP-16 family. Typical applications include high-side power-supply monitoring, bidirectional motor-current measurement, industrial control systems, battery current sensing, solenoid monitoring, and electronic protection. In these systems, the amplifier reconstructs a current-proportional voltage that can be digitized or compared with a threshold. System calibration should account for the selected gain, reference voltage, ADC resolution, and the measurement bandwidth required by the load. Design attention should focus on Kelvin routing for the reference connection, filtering around the output when the measured waveform contains high-frequency noise, and thermal verification at maximum continuous current. The integrated shunt is convenient, but PCB copper, vias, pads, and connector geometry can limit practical current and increase temperature rise. Use the manufacturer pin-description table when assigning PCB tracks and the device data sheet for the complete recommended layout. This page combines the manufacturer device description, package and operating information, practical application guidance, replacement criteria, and engineering-oriented design notes. These resources help engineers evaluate the INA250A1PWR beyond a basic distributor listing while keeping pin compatibility and measurement accuracy at the center of the selection process.

詢價 聯絡我們
INA250A2PWR - 36V Bidirectional Current-Sense Amplifier | TI
INA250A2PWR

INA250A2PWR - 36V Bidirectional Current-Sense Amplifier | TI

The Texas Instruments INA250A2PWR is a bidirectional, precision current-sense amplifier with an integrated shunt resistor, a 36 V maximum common-mode range, and a 16-pin TSSOP (PW) package. It supports low-side or high-side current measurement from 0 V to 36 V, operates from a single supply, and produces a voltage output proportional to the measured shunt current. According to the manufacturer datasheet, the device also accepts an external reference for centered, bidirectional measurements. A current-sense amplifier is an instrumentation amplifier that measures the small voltage generated across a current-carrying shunt resistor and converts it into a larger, easier-to-process voltage. In the product hierarchy, the INA250 belongs to the current-shunt monitor family within instrumentation amplifiers and analog signal-chain ICs. Its integrated shunt eliminates the need for a separate precision shunt in common-mode applications, simplifying current sensing in power supplies, motor controls, industrial equipment, and automotive systems. The INA250A2PWR combines bidirectional measurement with a wide common-mode operating range. Its voltage-output architecture can be referenced to ground for unidirectional sensing or shifted around an external reference for centered measurements. Zero-drift operation reduces temperature-dependent error, while integrated shunt matching and precision signal conditioning support accurate measurements in demanding power-control systems. The 16-pin TSSOP package also provides a compact surface-mount footprint for mixed-signal and industrial circuit boards. The device is intended for low-side or high-side sensing because its common-mode input range extends from 0 V to 36 V independently of the supply voltage. This separation between common-mode range and supply range allows the input shunt to operate near the supply rail without requiring the amplifier supply to exceed that rail. A reference pin supports bidirectional output placement, and the internal amplifier is optimized for high-side motor, solenoid, and power-supply current monitoring. Typical uses include DC motor current control, industrial actuator monitoring, solenoid current sensing, power-converter feedback, battery current measurement, and electronic circuit protection. The device is particularly useful when the current path is not referenced to ground, because the common-mode input can remain at a positive voltage. Its integrated shunt also reduces the number of precision external components required for a first prototype. When laying out a board, route the shunt connections as short and symmetrical as possible because trace resistance and unequal routing can unbalance the differential measurement. Keep the input and reference paths away from high-current switching nodes and provide a stable, low-noise reference network. Review the manufacturer pin description and recommended application circuit before assigning tracks around the exposed package features. This page combines the manufacturer's device description, ordering information, package details, and application guidance with practical layout considerations. It also identifies where gain or interface alternatives require a different part number rather than presenting them as unqualified pin-to-pin substitutes.

詢價 聯絡我們
INA250A3PW - 36V Bidirectional Current Sense Amplifier | TI
INA250A3PW

INA250A3PW - 36V Bidirectional Current Sense Amplifier | TI

Texas Instruments INA250A3PW is a bidirectional precision current-sense amplifier with an integrated shunt resistor, 100 V/V gain, and operation from a 2.7 V to 36 V supply. The device measures low- and high-side current across common-mode voltages from 0 V to 36 V and is housed in a 16-pin TSSOP package. Its voltage output supports direct connection to analog-to-digital converters, controllers, and monitoring systems. A current-sense amplifier converts the voltage generated across a shunt resistor into a proportional, measurable voltage. This integrated-resistor implementation belongs to the current-shunt monitor class within precision amplifier and power-management ICs. By placing the shunt inside the amplifier package, it removes the need for a separate precision shunt while reducing layout sensitivity associated with external Kelvin connections. The INA250A3PW provides a gain of 100 V/V, allowing the 50 mΩ integrated shunt to support current measurements up to 15 A according to the family specifications. Bidirectional operation measures positive or negative current, and an external reference can establish the output operating point for zero-current offset or bipolar reporting. A 2.7 V minimum supply permits use in low-voltage systems while the 36 V supply rating supports higher-voltage industrial buses. The INA250 family specifies a maximum supply current of 300 µA and operation from -40 °C to 125 °C. Its integrated shunt and Kelvin-connected internal structure improve measurement accuracy by reducing lead and trace resistance effects. The voltage-output architecture requires downstream filtering and input/output stability capacitors selected according to the manufacturer datasheet, rather than relying on an internal shunt resistor placed outside the package. Typical applications include motor and solenoid current monitoring, power-supply telemetry, battery-pack management, industrial control systems, and high-side or low-side protection. The device can monitor current in systems whose supply voltage changes independently of the sensed common-mode voltage, making it useful in 24 V industrial equipment, automotive-style loads, and distributed power architectures. Design layouts should keep the power path short and use solid copper planes so that shunt heat is distributed rather than concentrated in a narrow trace. Confirm output saturation, reference-pin behavior, common-mode limits, and filter-component values against the manufacturer datasheet before operating at the 15 A family limit. This page combines device specifications, application guidance, pin and package considerations, lifecycle information, and verified replacement analysis. It also distinguishes electrically similar family members from true pin-compatible drop-in choices so that PCB reuse decisions are based on measurable electrical differences rather than package similarity alone.

詢價 聯絡我們
INA250A3PWR - 36V Bidirectional Current Sense Amplifier | TI (Tape & Reel)
INA250A3PWR

INA250A3PWR - 36V Bidirectional Current Sense Amplifier | TI (Tape & Reel)

Texas Instruments INA250A3PWR is a bidirectional precision current-sense amplifier with an integrated shunt resistor, 100 V/V gain, and operation from a 2.7 V to 36 V supply. The device measures low- and high-side current across common-mode voltages from 0 V to 36 V and is housed in a 16-pin TSSOP package. Its voltage output supports direct connection to analog-to-digital converters, controllers, and monitoring systems. A current-sense amplifier converts the voltage generated across a shunt resistor into a proportional, measurable voltage. This integrated-resistor implementation belongs to the current-shunt monitor class within precision amplifier and power-management ICs. By placing the shunt inside the amplifier package, it removes the need for a separate precision shunt while reducing layout sensitivity associated with external Kelvin connections. The INA250A3PWR provides a gain of 100 V/V, allowing the 50 mΩ integrated shunt to support current measurements up to 15 A according to the family specifications. Bidirectional operation measures positive or negative current, and an external reference can establish the output operating point for zero-current offset or bipolar reporting. A 2.7 V minimum supply permits use in low-voltage systems while the 36 V supply rating supports higher-voltage industrial buses. The INA250 family specifies a maximum supply current of 300 µA and operation from -40 °C to 125 °C. Its integrated shunt and Kelvin-connected internal structure improve measurement accuracy by reducing lead and trace resistance effects. The voltage-output architecture requires downstream filtering and input/output stability capacitors selected according to the manufacturer datasheet, rather than relying on an internal shunt resistor placed outside the package. Typical applications include motor and solenoid current monitoring, power-supply telemetry, battery-pack management, industrial control systems, and high-side or low-side protection. The device can monitor current in systems whose supply voltage changes independently of the sensed common-mode voltage, making it useful in 24 V industrial equipment, automotive-style loads, and distributed power architectures. Design layouts should keep the power path short and use solid copper planes so that shunt heat is distributed rather than concentrated in a narrow trace. Confirm output saturation, reference-pin behavior, common-mode limits, and filter-component values against the manufacturer datasheet before operating at the 15 A family limit. This page combines device specifications, application guidance, pin and package considerations, lifecycle information, and verified replacement analysis. It also distinguishes electrically similar family members from true pin-compatible drop-in choices so that PCB reuse decisions are based on measurable electrical differences rather than package similarity alone.

詢價 聯絡我們
INA253A1IPW - 80V Bidirectional Current Sense Amp | TI
INA253A1IPW

INA253A1IPW - 80V Bidirectional Current Sense Amp | TI

The Texas Instruments INA253A1IPW is an 80 V bidirectional precision current-sense amplifier with PWM rejection and an integrated 2 mΩ precision, low-inductance shunt resistor, packaged in a 20-pin TSSOP. The device accepts a supply voltage of 2.7 V to 5.5 V and operates across a -40°C to 125°C temperature range. It converts the voltage developed across the integrated shunt into an amplified analog output that can be measured by an ADC, controller, or protection circuit. A current-sense amplifier is a specialized amplifier that measures the voltage across a current sensor and produces an output proportional to the sensed current. The INA253 belongs to the instrumentation-amplifier and current-sensing IC hierarchy, where its integrated shunt combines current measurement with low-inductance sensing. This integration simplifies the power path and supports bidirectional measurement, allowing positive and negative current to be represented around a common zero-current output level. Key features include an 80 V common-mode input range, bidirectional current sensing, PWM rejection, zero-drift operation, and an integrated 2 mΩ shunt resistor. The A1 gain option provides a 50 V/V output ratio. The 20-pin TSSOP package provides a compact surface-mount format for industrial, automotive-adjacent, communications, and power-supply control systems where measured current must withstand substantial switching-node transients. The integrated shunt is the defining technical feature. A low-inductance sensing element limits the voltage spikes that would otherwise appear when current changes rapidly. The PWM-rejection architecture reduces disturbance from switching waveforms, while the zero-drift input stage improves accuracy around zero current. Compared with a discrete shunt-and-amplifier implementation, the INA253 reduces board area and component count while retaining the gain and common-mode ratings needed for demanding power-conversion circuits. Typical uses include DC-DC converter output-current monitoring, bidirectional motor-control current measurement, battery and power-path monitoring, and protection in industrial equipment. The 80 V common-mode capability is especially useful when the sensed conductor sits near a switching node. The integrated shunt also makes the device suitable for compact instrumentation where external Kelvin routing and discrete shunt placement would increase complexity. For PCB design, keep the high-current path electrically short and place the amplifier and its decoupling capacitors close to the supply pins. Review the manufacturer datasheet's layout example for the recommended shunt and grounding arrangement. Confirm that the analog output remains within the input range of the receiving ADC, and account for amplifier output swing and system offset when defining trip thresholds. This page combines the manufacturer's key INA253A1IPW specifications with same-package family alternatives, package details, application guidance, and selection considerations. It is intended to help engineers identify the correct gain and automotive options without overlooking common-mode rating, shunt integration, temperature range, or PCB-layout requirements.

詢價 聯絡我們
INA253A2IPW - 80V Bidirectional Current Sense Amp | TI
INA253A2IPW

INA253A2IPW - 80V Bidirectional Current Sense Amp | TI

The Texas Instruments INA253A2IPW is a bidirectional, zero-drift current-shunt monitor with an integrated 2 mΩ shunt resistor, 200 mV/A gain, and a 20-pin TSSOP package. It operates from a 2.7 V to 5.5 V supply while monitoring common-mode voltages from -4 V to +80 V. The device combines precise current measurement with PWM rejection in a single surface-mount IC. A current-sense amplifier is an instrumentation amplifier that measures the small voltage generated across a shunt resistor and converts it into a proportional output voltage. The INA253 belongs to the current-sense amplifier hierarchy, where it bridges precision analog measurement and power-system monitoring. Integrating the shunt resistor reduces external component count and helps standardize the sensing element for bidirectional current applications. Key electrical features include 350 kHz -3 dB bandwidth, 2.4 V/µs slew rate, 90 pA input bias current, and 1.8 mA supply current. The A2 gain version produces 200 mV/V output for each ampere of sensed current. Its wide -4 V to +80 V common-mode range allows the shunt path to operate at high bus voltages while the amplifier itself remains powered from a low-voltage supply. Internally, the zero-drift architecture supports low offset behavior in precision measurement systems. The integrated precision shunt and chopper-stabilized amplifier are designed for systems where board space, component count, and current-direction measurement are important. Because the sensing element is integrated, PCB design should preserve the manufacturer-recommended current-path geometry and thermal conditions. Typical applications include motor-drive phase current monitoring, industrial power-supply control, battery current measurement, solenoid current sensing, and LED driver feedback. The -4 V to +80 V common-mode capability is particularly useful in systems where a shunt can be placed in a high-voltage conductor while the INA253 remains connected to a 2.7 V to 5.5 V control supply. Use the pin-description table in the manufacturer datasheet when assigning PCB tracks, especially for IN+, IN−, REF, OUT, and supply connections. Account for shunt heating at sustained high current and place input and reference components close to the device to minimize added error and pickup from fast-switching nodes. This page organizes the electrical characteristics, application guidance, confirmed family alternatives, and design trade-offs of the INA253A2IPW. It helps engineers distinguish what the integrated 2 mΩ solution provides from lower-current sensing approaches and from gain variants in the same INA253 family.

詢價 聯絡我們
INA253A3IPW - 400mV/A Bidirectional Current Sense | Texas Instruments
INA253A3IPW

INA253A3IPW - 400mV/A Bidirectional Current Sense | Texas Instruments

The Texas Instruments INA253A3IPW is a precision current-shunt monitor with a 400 mV/A gain, an 80 V common-mode range, and an integrated 2 mΩ low-inductive shunt resistor in a 20-pin TSSOP package. It supports bidirectional current measurement from -4 V to +80 V while combining a zero-drift chopped amplifier with integrated shunt-resistor current sensing. A current-shunt monitor is an instrumentation amplifier that measures the small voltage generated across a precision shunt resistor as current flows through a conductor. The INA253 belongs to the current-sense amplifier hierarchy, where the amplified shunt voltage is filtered, digitized, or used for power monitoring and control. Its integrated resistor simplifies the sensing path, reduces external component count, and keeps the shunt geometry close to the amplifier for improved measurement repeatability. The A3 gain option provides 400 mV/A, while the INA253 family also includes 100 mV/A and 200 mV/A versions. The device operates over a -4 V to +80 V common-mode range, independent of its supply voltage, which supports high-side sensing in 48 V industrial, communications, automotive, and power-system environments. Its 350 kHz -3 dB bandwidth accommodates dynamic current measurements while providing rejection of PWM-related disturbances. The INA253A3IPW combines precision zero-drift signal conditioning with an integrated 2 mΩ shunt. Bidirectional operation allows the output to move above or below ground depending on current direction. The listed operating-temperature range is -40°C to +125°C, and the device is supplied in a 20-pin TSSOP package measuring 0.173 inch, or 4.40 mm, in width. Typical uses include server and telecom power rails, industrial motor controls, battery-management systems, LED drivers, solenoid drivers, and automotive load monitoring. In each application, the shunt monitor converts bidirectional current into a proportional analog voltage, allowing a controller to monitor load current, detect overcurrent, or implement closed-loop power management. PCB layout is critical because the integrated shunt and amplifier must be placed directly in the current path. High-current conductors should use short, wide copper, while the supply and ground connections should follow the manufacturer’s pin-assignment and layout guidance. Designers should also account for output settling, filter selection, and common-mode transient protection when operating near rapidly switching power stages. This product page combines the exact ordering information, electrical characteristics, family-level comparison, and application guidance needed to plan an INA253A3-based current-measurement design. It also identifies which same-package alternatives can be evaluated when gain, automotive qualification, or supply requirements differ.

詢價 聯絡我們
INA293B1QDBVRQ1 - 110V, 1.3MHz Current Sense Amp | TI
INA293B1QDBVRQ1

INA293B1QDBVRQ1 - 110V, 1.3MHz Current Sense Amp | TI

The Texas Instruments INA293B1QDBVRQ1 is an AEC-Q100 qualified, ultra-precise bidirectional current-sense amplifier that measures voltage drops across shunt resistors over an exceptionally wide common-mode range from -4 V to +110 V. It delivers a 1.3 MHz small-signal bandwidth with a 20 V/V fixed gain (B1 variant) in a 5-pin SOT-23 (DBV) package, making it ideal for high-voltage, high-precision current monitoring in space-constrained automotive and industrial designs. What is a current-sense amplifier? A current-sense amplifier is a specialized analog building block that measures the small differential voltage developed across a shunt resistor placed in series with a load or supply rail, and converts it to a ground-referenced output voltage proportional to load current. Unlike a general-purpose op amp, a current-sense amplifier tolerates large common-mode voltages - often well above its own supply - and rejects the common-mode component, exposing only the shunt drop. The INA293-Q1 sits at the high-precision end of this category, combining low offset, low drift, and the widest common-mode range in TI's portfolio of unidirectional/bidirectional current-sense amplifiers. Key features include a maximum offset voltage of ±30 µV across temperature, ±0.2% gain error, and a quiescent current of approximately 1.5 mA over the -40 °C to +125 °C automotive grade-1 temperature range. The B1 gain variant provides 20 V/V; the B2, B3, B4, and B5 variants in the same family offer 50 V/V, 100 V/V, 200 V/V, and 500 V/V respectively, all sharing the SOT-23-5 footprint. The device operates from a single 2.7 V to 20 V supply and is robust against input transients well beyond its supply rail. Internally, the INA293-Q1 uses a precision chopped-input front end followed by a fixed-gain output stage, achieving CMRR greater than 100 dB at DC and PSRR above 80 dB at 1 kHz. The wide common-mode architecture supports both high-side and low-side sensing topologies, enabling accurate monitoring in 48 V mild-hybrid automotive systems, industrial 24 V/36 V/48 V rails, and telecom -48 V applications without level shifting. Typical applications include 48 V eMobility battery management, BLDC motor phase-current monitoring, server/AI accelerator hot-swap current telemetry, USB Power Delivery contract current sensing, and solar inverter string monitoring. Compared with isolated current transducers, the INA293-Q1 achieves comparable accuracy at a fraction of the BOM cost and PCB area. When designing with this device, place the shunt resistor as close as possible to the input pins and keep the input traces symmetrical to preserve CMRR. A 0.1 µF supply bypass capacitor placed within 5 mm of the V+ pin is recommended for stable operation across the full -4 V to +110 V common-mode range. This page synthesizes distributor pricing, drop-in alternatives from the INA293-Q1 family and competing high-side current-sense amplifiers, and practical design notes that go beyond the manufacturer datasheet.

詢價 聯絡我們
INA317IDGKT - 50µA Zero-Drift INA | Texas Instruments
INA317IDGKT

INA317IDGKT - 50µA Zero-Drift INA | Texas Instruments

The Texas Instruments INA317IDGKT is a micro-power, zero-drift, rail-to-rail-output instrumentation amplifier with a 50µA typical supply current, 75µV offset voltage at gains of 100 or higher, and 0.3µV/°C offset drift. It is offered in an 8-pin VSSOP package and operates across a -40°C to +125°C ambient-temperature range. An instrumentation amplifier is a precision differential-input amplifier optimized for measuring small signals superimposed on a larger common-mode voltage. Its internal three-operational-amplifier architecture provides differential gain, high input impedance, and common-mode rejection. The INA317 belongs to the instrumentation amplifier class within the broader operational-amplifier and analog-signal-conditioning hierarchy. The INA317 combines low offset, low drift, low noise density, and low quiescent current. According to the Texas Instruments product information, its 50nV/√Hz input-noise density extends down to DC, while its common-mode rejection reaches 100dB at a gain of 10 or higher. Autocalibration techniques are used to maintain precision over the extended industrial temperature range. The INA317 supports supply voltages as low as 1.8V, equivalent to ±0.9V for a dual-supply arrangement. A single external gain resistor sets the closed-loop gain from 1 to 1000 using G = 1 + (100kΩ/RG). Rail-to-rail output operation allows the output to use nearly the available output-voltage range, which is useful in compact low-voltage sensor systems. Typical applications include portable sensor acquisition, battery-powered measurement systems, bridge-sensor interfaces, biomedical instrumentation, and precision current sensing. Its low 50µA quiescent current is particularly valuable for portable equipment, while the 8-pin VSSOP package supports compact layouts. Designers should place the gain resistor close to the RG pins to minimize added noise and parasitic resistance. Decoupling capacitors should be connected directly to the supply pins, and the REF connection should be driven only when the circuit does not require the default midscale reference behavior. Input and output settling should be checked across the intended gain and signal bandwidth.

詢價 聯絡我們
INA321EA/250 - Micropower RRO Instrumentation Amp | TI
INA321EA/250

INA321EA/250 - Micropower RRO Instrumentation Amp | TI

Texas Instruments INA321EA/250 is a micropower, single-supply CMOS instrumentation amplifier with 40 µA typical supply current, 500 µV maximum offset voltage, 10 pA maximum bias current, and rail-to-rail output operation in an 8-pin VSSOP (DGK) package. Its specified operating range is 2.7 V to 5.5 V, with output swing to approximately ±2.75 V at a 5.5 V supply. An instrumentation amplifier is a specialized amplifier optimized for measuring small differential signals superimposed on a larger common-mode voltage. Its internal three-amplifier architecture provides high input impedance, controlled gain, and accurate differential amplification without requiring closely matched external resistors. The INA321 belongs to the instrumentation amplifier hierarchy, where it combines analog signal conditioning with power-management-conscious low-leakage characteristics for battery-powered and compact embedded systems. Key features include rail-to-rail output, shutdown support, low offset voltage, and low bias current. The 500 µV offset specification limits the input-referred error that can become important when resolving small sensor signals, while the 10 pA bias-current limit is particularly useful with high-impedance sources. The listed 500 kHz bandwidth and 0.04 V/µs slew rate support signal amplification without requiring the higher power consumption of a high-speed instrumentation amplifier. Technically, the INA321 is designed around a CMOS instrumentation-amplifier architecture and operates from a single supply. Rail-to-rail output allows the output to approach the supply rails more closely than a conventional fixed common-mode output, improving usable dynamic range in low-voltage designs. The 40 µA micropower operating current and shutdown function support duty-cycled acquisition systems in which the amplifier can be disabled between measurements. Typical uses include portable medical instrumentation, battery-powered sensor interfaces, low-current industrial monitoring, laboratory measurement systems, and compact test equipment. A bridge sensor, electrochemical sensor, or low-current transducer can feed the differential inputs, while the amplifier provides a single-ended, rail-to-rail output suitable for conversion by an ADC. When designing around the INA321EA/250, preserve the specified input and output common-mode limits, verify gain-setting accuracy, and provide stable bypassing close to the supply pins. Pay particular attention to source impedance and leakage when the measured signal has high output resistance, because input bias current creates an input-referred voltage error even when the amplifier itself is operating correctly. This product page consolidates the electrical characteristics, package information, practical application guidance, and verified ordering identifiers for INA321EA/250. It also distinguishes true pin-compatible replacements from ordering-code variants so engineers can make a board-level decision without assuming that a similarly packaged part has identical electrical behavior.

詢價 聯絡我們
INA321EA/2K5 - Micropower RRO Instrumentation Amplifier | Texas Instruments
INA321EA/2K5

INA321EA/2K5 - Micropower RRO Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA321EA/2K5 is a single-supply micropower CMOS instrumentation amplifier with 40 uA typical quiescent current, less than 1 uA shutdown current, and a 500 uV maximum offset specification. It provides rail-to-rail output, 94 dB common-mode rejection, 10 pA bias current, and external-resistor gain control in an 8-pin VSSOP (DGK) package. An instrumentation amplifier is a differential analog amplifier optimized for measuring small signals superimposed on a larger common-mode voltage. The INA321 belongs to the hierarchy of instrumentation amplifiers, differential amplifiers, amplifier ICs, and analog semiconductors. Its differential input stage rejects common-mode interference while amplifying the voltage difference between its input terminals, making it useful for bridge sensors, biomedical instrumentation, and low-voltage current measurement. Key features include a typical operating current of 40 uA, an offset voltage specified by the manufacturer at 500 uV maximum, a common-mode rejection ratio of 94 dB, and an input bias current of 10 pA. The shutdown function reduces quiescent current to below 1 uA. Its rail-to-rail output can approach the positive supply rail to within 0.02 V, while gain is established with external resistors. The high input impedance and low bias current are especially valuable when sensing high-source-impedance sensors. The amplifier uses a CMOS instrumentation-amplifier architecture optimized for low power and single-supply operation. With a gain of 5 V/V, the listed bandwidth is 500 kHz, providing useful bandwidth for slow biomedical signals, industrial bridges, and general-purpose differential measurements. Because the output approaches the positive rail, correct common-mode range and output-swing calculations remain essential when operating near the supply limit. Typical uses include low-power bridge-sensor conditioning, portable medical instrumentation, battery-powered sensor acquisition, current-shunt measurement, and precision analog front ends. The 40 uA operating current supports energy-limited systems, while shutdown supports duty-cycled measurement in which the amplifier remains inactive between readings. The low bias current minimizes disturbance from high-impedance sources. When designing the circuit, place the gain-setting resistors close to the amplifier and verify the complete input and output common-mode range against the actual signal. If the input is unipolar, bias it near mid-supply rather than allowing a negative input excursion. Do not substitute a similarly packaged instrumentation amplifier unless its pin functions, gain architecture, common-mode range, and output-swing behavior have all been checked. This product page combines the manufacturer's device specifications with practical application guidance, package information, pin mapping, sourcing guidance, and a comparison of available same-family choices. These engineering details help shorten component selection while keeping the decision focused on electrical compatibility rather than package name alone.

詢價 聯絡我們
INA322EA/250 - Micropower Rail-to-Rail INA | Texas Instruments
INA322EA/250

INA322EA/250 - Micropower Rail-to-Rail INA | Texas Instruments

Texas Instruments INA322EA/250 is a micropower, single-supply CMOS instrumentation amplifier with 40 µA per channel of supply current, 2 mV typical input offset voltage, 10 pA input bias current, and rail-to-rail output operation in an 8-pin VSSOP (DGK) package. The /250 ordering option is supplied on a 250-unit tape-and-reel format. It accepts single-supply or bipolar-supply operation and uses external resistors to set the closed-loop gain. An instrumentation amplifier is a precision analog signal-conditioning amplifier optimized for measuring small differential voltages embedded in larger common-mode voltages. Unlike a general-purpose operational amplifier, an instrumentation amplifier commonly provides high input impedance, symmetrical differential inputs, accurate gain control, and strong common-mode rejection. The INA322 belongs to the instrumentation-amplifier hierarchy within analog ICs, signal-chain conditioning, and sensor-interface applications. Key characteristics include a 40 µA per-channel quiescent current, approximately 1 µA shutdown current, a 2 ppm/°C gain drift specification, and a 10 pA bias current. External gain resistors make the closed-loop gain selectable rather than fixed. The rail-to-rail output can approach the positive supply rail closely, making the device useful in low-voltage systems where amplified sensor output must use much of the available signal range. The INA322 architecture uses an instrumentation-amplifier input stage to preserve common-mode rejection while amplifying the differential sensor signal. Its specified offset performance supports precision measurement of low-level signals, while the micropower bias allows continuous operation from constrained supplies. A closed-loop gain of 25 V/V appears in the manufacturer-part data, and operating temperature coverage extends from -55 °C to 125 °C for the identified ordering option. Typical uses include bridge and strain-gauge conditioning, pressure and load-cell front ends, biomedical instrumentation, industrial sensor acquisition, and battery-powered measurement systems. The low 40 µA per-channel current is particularly useful when several measurement channels must operate from a compact power budget. The 10 pA bias current helps minimize loading on high-impedance sensors. Design attention should center on gain-resistor selection, supply bypassing, input common-mode range, and output-signal headroom. Place the differential input connections away from switching nodes and noisy return currents. Use the manufacturer’s recommended capacitor and layout guidance, and verify that the input and output operating regions remain valid across the intended supply and temperature range. This page consolidates the manufacturer’s device description, package information, ordering details, electrical characteristics, comparison guidance, and practical design notes into one engineering reference for INA322EA/250 evaluation and PCB planning.

詢價 聯絡我們
INA322EA/2K5 - 25 V/V Micropower Instrumentation Amplifier | TI
INA322EA/2K5

INA322EA/2K5 - 25 V/V Micropower Instrumentation Amplifier | TI

The Texas Instruments INA322EA/2K5 is a micropower, single-supply CMOS instrumentation amplifier with a fixed closed-loop gain of 25 V/V, 40 µA typical supply current, 2 mV input offset voltage, and 10 pA input bias current in an 8-pin VSSOP (DGK) package. Designed for low-power measurement systems, it accepts inputs near the supply rails while providing rail-to-rail output operation. An instrumentation amplifier is a precision analog signal-conditioning component that amplifies the differential voltage between two inputs while rejecting common-mode interference. Its internal architecture is designed to provide high input impedance, consistent gain set by external resistors, and better common-mode rejection than ordinary op-amp configurations. The INA322 belongs to the broader hierarchy of instrumentation amplifier, analog amplifier, signal-conditioning IC, and power-management semiconductor. The INA322EA/2K5 provides a 40 µA typical quiescent current, 25 V/V gain, 60 dB minimum common-mode rejection, and 10 pA typical input bias current. Its low bias current is particularly useful when measuring high-impedance sensors because it minimizes loading of the source. The 2 mV offset specification supports low-level differential measurements, while rail-to-rail output operation increases the usable output range within a compact single-supply system. The gain is established with an external resistor, allowing the INA322 family to be used as a fixed-gain element in low-power analog front ends. Shutdown capability further reduces supply demand when measurements are not continuous. The manufacturer identifies the device as a low-cost, micropower CMOS instrumentation amplifier supporting single-supply and bipolar-supply operation, with the ordering code /2K5 denoting the 25 V/V configuration. Typical uses include battery-powered sensor interfaces, portable measurement instruments, current-shunt monitoring, low-voltage process-control signals, and low-energy IoT nodes. Its small VSSOP package and low 40 µA supply current are advantageous when board area and battery life are primary constraints. For systems requiring very high precision or integrated analog-to-digital conversion, the INA322 can provide analog conditioning before a separate converter. The main design consideration is input common-mode range: a differential signal is useful only while both input pins remain within the amplifier’s valid operating region. Input filtering, source impedance, resistor matching, and supply bypassing must therefore be evaluated together. Place the gain-setting resistor close to the appropriate device pin and connect the reference pin according to the manufacturer’s recommended application circuit when the output must be shifted. This page combines the manufacturer’s device specifications with practical interface guidance, sourcing information, and a direct comparison against a pin-compatible INA326 alternative. It also highlights where the INA322’s 25 V/V gain, 40 µA operating current, and 8-pin VSSOP footprint simplify a micropower instrumentation design.

詢價 聯絡我們
INA326EA/250 - 1kHz Precision Instrumentation Amplifier | TI
INA326EA/250

INA326EA/250 - 1kHz Precision Instrumentation Amplifier | TI

The Texas Instruments INA326EA/250 is a precision, low-drift CMOS instrumentation amplifier with rail-to-rail input and output operation, 100 µV maximum input offset voltage, 114 dB typical gain bandwidth at 1 kHz, and 33 nV/√Hz typical input noise. The device is supplied in an 8-pin VSSOP (DGK) package and operates from 2.7 V to 5.5 V. An instrumentation amplifier is a specialized analog amplifier optimized for measuring small differential signals while rejecting common-mode interference. Its internal architecture provides gain, differential sensing, and input common-mode rejection in one device. Within the broader hierarchy, an instrumentation amplifier is an amplifier IC and a precision signal-conditioning component used ahead of converters, sensors, and data-acquisition systems. The INA326 family is designed for systems requiring low drift, low noise, and rail-to-rail signal-chain flexibility. Key characteristics include one amplifier channel, a 0.1 V/V to 1000 V/V programmable gain range, rail-to-rail inputs and outputs, a 2.7 V to 5.5 V supply range, and operation from -40 °C to 85 °C. The combination of 100 µV maximum input offset and 33 nV/√Hz typical noise supports accurate extraction of low-level differential signals. The 1 kHz gain-bandwidth characteristic makes the device suitable for precision rather than high-speed signal acquisition. The INA326EA/250 uses a CMOS implementation to combine low input bias current, low offset voltage, and low drift with rail-to-rail input and output behavior. Because its output can approach the supply rails, downstream circuitry can use a wide portion of the available analog voltage range. Its programmable gain allows one device family to serve applications ranging from modest differential amplification to high-gain sensor conditioning while preserving the same 8-pin footprint. Typical uses include bridge and strain-gauge signal conditioning, low-level current measurement, precision sensor interfaces, medical instrumentation, industrial process measurement, and data-acquisition front ends. The device is particularly appropriate when the target signal is differential, the common-mode environment is demanding, and measurement accuracy matters more than wideband throughput. A suitable analog-to-digital converter can then digitize the conditioned output. A key design consideration is to preserve the differential nature of the input signal. Keep input routing compact, use symmetric interconnections where practical, and place the gain-setting resistor close to the RG pin. Follow the Texas Instruments datasheet pin-description table when assigning PCB tracks, and confirm that the selected gain, supply voltage, and output-swing requirements remain compatible with the intended sensor. This page consolidates the Texas Instruments product characteristics, ordering information, package details, technical comparisons, and application guidance for engineers evaluating the INA326EA/250. It also organizes drop-in ordering options, practical design considerations, and search-focused technical information into one engineering reference.

詢價 聯絡我們
INA326EA/2K5 - Precision Instrumentation Amplifier | TI
INA326EA/2K5

INA326EA/2K5 - Precision Instrumentation Amplifier | TI

The Texas Instruments INA326EA/2K5 is a precision, low-drift CMOS instrumentation amplifier with a fixed gain of 25 V/V, rail-to-rail input and output operation, and a 1 kHz gain-bandwidth product. It operates from a single 2.7 V to 5.5 V supply and is packaged in an 8-pin VSSOP (DGK) surface-mount package. An instrumentation amplifier is a differential analog amplifier optimized for measuring small signals while rejecting common-mode interference. Its internal architecture provides high input impedance, accurate differential gain, and controlled output behavior, making it more suitable for bridge sensors, biopotential signals, and current-shunt measurements than a general-purpose operational amplifier. The INA326 belongs to the instrumentation amplifier, analog IC, and semiconductor hierarchy. The INA326EA/2K5 combines a 0.1 V/V to 1000 V/V programmable gain range across the device family with a typical input offset voltage of 100 µV and input noise density of 33 nV/√Hz at 1 kHz. Rail-to-rail inputs increase usable signal range on low-voltage supplies, while the rail-to-rail output supports direct interface to low-voltage analog converters and control circuitry. The amplifier uses a precision, low-drift CMOS implementation to improve DC accuracy over temperature and time. At its fixed gain of 25 V/V, the 1 kHz gain-bandwidth product limits the usable closed-loop bandwidth to approximately 40 kHz. This bandwidth-versus-precision balance favors stable sensing channels operating at low or moderate frequencies rather than high-speed waveform acquisition. Typical uses include bridge-based pressure and strain measurements, ECG and biometric sensing, battery-current monitoring, industrial process-control instrumentation, and precision sensor interfaces. The 8-pin VSSOP package makes the device suitable for compact mixed-signal boards, while the single-supply operation simplifies portable and industrial equipment power architecture. Designers should verify gain-bandwidth behavior, settling time, input common-mode range, and output swing against the signal bandwidth and supply voltage. Input filtering and proper grounding are important when the source has substantial differential impedance or when common-mode voltage approaches either supply rail. This page combines the manufacturer ordering information, confirmed package and electrical characteristics, practical application guidance, and engineering-focused comparisons. It also distinguishes package-compatible family options from a verified drop-in replacement, helping engineers make a board-level decision without relying on packaging-only variants.

詢價 聯絡我們
INA327EA/250 - Precision Rail-to-Rail INA | Texas Instruments
INA327EA/250

INA327EA/250 - Precision Rail-to-Rail INA | Texas Instruments

Texas Instruments INA327EA/250 is a precision, low-drift CMOS instrumentation amplifier with rail-to-rail input and output, shutdown support, a 1 kHz gain-bandwidth product, and a 10-pin VSSOP (DGS) package. It operates from 2.7 V to 5.5 V and is designed for low-side current sensing, sensor conditioning, and measurement systems requiring accurate differential amplification with minimal drift. An instrumentation amplifier is a specialized amplifier that combines differential input sensing, high input impedance, precise gain setting, and common-mode rejection in one package. This functional category belongs to the amplifier IC hierarchy, where precision instrumentation amplifiers outperform general-purpose operational amplifiers in applications that must measure small differential signals while rejecting large common-mode voltages. The INA327 provides a 1 kHz gain-bandwidth product, rail-to-rail input and output operation, an input bias current of 200 pA, and a common-mode input range that extends beyond the positive and negative supply rails. Its true single-supply architecture supports operation from a single 2.7 V to 5.5 V supply, while low DC errors and low drift suit precision measurement equipment. The INA327EA/250 uses an external resistor network to establish gain, allowing the amplifier to be adapted to different sensor scales without changing the integrated circuit. Its CMOS input stage supports low input bias current and broad common-mode range, although the relatively narrow 1 kHz bandwidth makes it more appropriate for current, temperature, pressure, and slowly varying sensor signals than for wideband signal chains. Typical applications include shunt-based current measurement in power-conversion systems, low-side motor and solenoid monitoring, bridge-sensor signal conditioning, battery current sensing, and precision industrial instrumentation. The shutdown function can reduce supply demand when the measurement channel is not active, while the 10-pin VSSOP package supports compact surface-mount layouts. The principal design consideration is input filtering. Gain-setting resistors and the instrument-amplifier inputs should be positioned close to the device, with differential and common-mode filtering selected carefully to preserve differential accuracy and common-mode rejection. The power rails must remain within the 2.7 V to 5.5 V operating limits, and unused inputs should be connected according to the manufacturer pin-description table. This page combines manufacturer ordering information, package and operating details, drop-in alternatives, application guidance, PCB considerations, and a parameter-by-parameter comparison to support faster component selection and implementation.

詢價 聯絡我們
INA331IDGKR - 25 V/V Rail-to-Rail Instrumentation Amp | TI
INA331IDGKR

INA331IDGKR - 25 V/V Rail-to-Rail Instrumentation Amp | TI

The Texas Instruments INA331IDGKR is a low-power, single-supply CMOS instrumentation amplifier with a closed-loop gain of 25 V/V, 2.0 MHz bandwidth, and 5 V/us slew rate, housed in an 8-pin VSSOP (DGK) package. It is designed for low-cost, high-gain accuracy with gain set by external resistors, 0.02% gain accuracy, and a 2 ppm/°C temperature coefficient. Additional headline specifications include ±250 µV offset voltage, 90 dB CMRR, and rail-to-rail operation. An instrumentation amplifier is a differential-input analog signal-conditioning IC that amplifies the voltage difference between two sensors while rejecting common-mode interference. The INA331 belongs to the hierarchy of instrumentation amplifier, differential amplifier, analog amplifier, and amplifier IC. It is used where a small sensor differential must be measured accurately in the presence of larger common-mode voltages, particularly in battery-powered industrial, medical, and portable systems. Key features include gain accuracy of 0.02% and a gain temperature coefficient of 2 ppm/°C for gains above 5 V/V. The device has an input offset voltage of ±250 µV, low input bias current, 90 dB CMRR, and a 2.0 MHz bandwidth. Its 5 V/us slew rate supports faster signal transitions, while single-supply and rail-to-rail operation simplify systems operating from a low-voltage source. The low-power design is suited to portable instrumentation and sensor interfaces. The INA331 uses external gain-setting resistors, allowing the closed-loop gain to be adjusted for the required measurement range without changing the package. At the specified 25 V/V gain, the device combines useful bandwidth for low-frequency sensor measurements with common-mode rejection for noisy industrial environments. The input and output stages operate from a single supply, reducing the number of rails required in portable equipment. Typical applications include low-side current sensing in battery systems, differential pressure and temperature measurement, biomedical instrumentation, portable sensor acquisition, industrial bridge excitation, and precision current measurement. The INA331 is especially appropriate when the sensor output is small, the required gain is above 5 V/V, and system power consumption must remain low. When implementing the circuit, place the gain-setting resistors close to the gain inputs and keep the input differential loop area small to minimize noise pickup. Check the common-mode input range at the selected supply voltage and gain because the amplifier must remain within its valid operating region. Decoupling capacitors should be positioned close to the supply pins, with the layout verified against the manufacturer reference layout. This page combines the exact orderable part information, package characteristics, gain and common-mode performance, application guidance, replacement analysis, and PCB considerations needed to evaluate INA331IDGKR before implementation.

詢價 聯絡我們
INA331IDGKT - Low-Power 8-Pin Instrumentation Amplifier | TI
INA331IDGKT

INA331IDGKT - Low-Power 8-Pin Instrumentation Amplifier | TI

The Texas Instruments INA331IDGKT is a low-power, single-supply CMOS instrumentation amplifier with a 2.0 MHz bandwidth, 5 V/µs slew rate, and low 415 µA quiescent current, housed in an 8-pin VSSOP (DGK) package. It provides rail-to-rail output operation, ±250 µV low offset voltage, and 94 dB DC common-mode rejection for precision differential-signal conditioning. An instrumentation amplifier is a specialized analog amplifier optimized for measuring small differential signals superimposed on a larger common-mode voltage. Its internal three-op-amp architecture provides high input impedance and accurate differential gain, while the INA331 simplifies the external signal chain by accepting single-supply or bipolar-supply operation. This places it within the hierarchy of instrumentation amplifier, differential amplifier, analog signal-conditioning IC, and power-management-independent semiconductor category. The INA331 supports externally set gains from 1 V/V through 1000 V/V, with a specified 25 V/V configuration providing 0.02% gain accuracy and a 2 ppm/°C gain-temperature coefficient. Its 94 dB DC CMRR, 50 dB CMRR at 45 kHz, and 5 V/µs slew rate make it suitable for sensors, current measurement, and precision bridge interfaces. A shutdown mode reduces quiescent current to 0.01 µA. Internally, the INA331 uses CMOS analog circuitry arranged to preserve low offset, low bias current, and accurate gain-setting behavior. The gain is established with an external resistor, which lets the designer select the required sensitivity without changing the package or PCB footprint. The 2.0 MHz bandwidth supports higher-speed signal bandwidth than many low-power precision instrumentation amplifiers, while the 5 V/µs slew rate helps maintain output linearity for rapidly varying inputs. Typical uses include bridge and strain-gauge conditioning, battery and power-supply current monitoring, medical instrumentation, industrial process measurement, and low-level sensor amplification. Its rail-to-rail output allows useful signal range in low-voltage systems, and its low 415 µA supply current supports portable and battery-operated equipment. For stable operation, place the gain-setting resistor close to the device, maintain the specified supply and common-mode voltage limits, and provide adequate input and output decoupling. Check the shutdown logic, output-reference arrangement, and input bias-current requirements against the sensor source impedance before finalizing the circuit. This page combines device specifications, replacement guidance, application-oriented engineering notes, and parameter comparisons to support component selection and PCB design. It is intended to help engineers evaluate the INA331IDGKT for low-noise, low-power differential measurement without relying on raw catalog listings alone.

詢價 聯絡我們
INA333AIDGKR - 50uA Zero-Drift INA | Texas Instruments
INA333AIDGKR

INA333AIDGKR - 50uA Zero-Drift INA | Texas Instruments

The Texas Instruments INA333AIDGKR is a low-power, precision, zero-drift instrumentation amplifier with a 1.8 V to 5.5 V supply range, 10 uV typical input offset voltage, 150 kHz bandwidth, and an 8-pin VSSOP (DGK) package. It uses a three-operational-amplifier architecture and one external gain-setting resistor to provide gains from 1 to 1000. An instrumentation amplifier is a differential analog amplifier optimized for measuring small voltage signals superimposed on larger common-mode voltages. Its internal three-op-amp topology provides high input impedance and accurate differential gain, making it more practical than a discrete difference amplifier when source impedances are unequal or signals arrive from sensors. INA333 belongs to the precision amplifier hierarchy: instrumentation amplifier, operational amplifier, analog IC, and semiconductor. The INA333 emphasizes low power, low offset drift, and rail-to-rail output operation. Verified source data identifies a 50 uA typical supply current and a gain equation of G = 1 + 100 kΩ/RG. The 150 kHz bandwidth supports fast sensor signals, while the 10 uV input offset specification improves measurement resolution around the zero-input condition. Its input stage is designed to reject common-mode variation encountered in bridge, current-sense, and portable sensing systems. The zero-drift architecture reduces temperature-related offset movement, helping preserve measurement stability when the sensor signal is small relative to input offset. Rail-to-rail output increases usable output swing on low-voltage supplies, although engineers must still verify input common-mode range, output swing, bandwidth, and input bias behavior across the complete intended voltage and temperature range using the manufacturer datasheet. Typical uses include portable medical monitoring, battery-powered industrial instrumentation, pressure and load-cell signal conditioning, low-side current measurement, and low-voltage sensor acquisition. The 50 uA power budget is especially useful for wearable and remote systems where every microamp affects battery life. The VSSOP-8 package supports compact layouts, but differential routing and gain-resistor placement remain essential. For best results, connect the gain resistor close to the RG pins, use a low-noise reference supply, maintain symmetric input routing, and follow the datasheet bypass recommendations. Verify common-mode limits at every operating point rather than assuming rail-to-rail input. This page combines verified distributor data, manufacturer specifications, sourcing guidance, and practical design context.

詢價 聯絡我們
INA333SHKQ - Zero-Drift Instrumentation Amplifier | Texas Instruments
INA333SHKQ

INA333SHKQ - Zero-Drift Instrumentation Amplifier | Texas Instruments

Texas Instruments INA333SHKQ is a micro-power, zero-drift, rail-to-rail output instrumentation amplifier with a closed-loop gain range of 100 to 1000 V/V. It is offered in an 8-pin HKQ ceramic flat package and is rated for operation from -55°C to +210°C. The high-temperature grade makes the device suitable for precision sensing systems that require stable amplification under extended thermal exposure. An instrumentation amplifier is a specialized analog amplifier optimized for measuring small differential signals while rejecting common-mode interference. Its internal differential architecture preserves signal integrity when the inputs share substantial common-mode voltage. Within the broader semiconductor hierarchy, an instrumentation amplifier belongs to the amplifier IC family and combines precision input, gain-setting, and differential-to-single-ended conversion functions in one device. The INA333SHKQ supports closed-loop gains from 100 to 1000 V/V. At a gain of 100, the manufacturer lists a maximum input offset voltage of 25 µV, a typical drift of 0.2 µV/°C, and noise density of 55 nV/√Hz. Its listed common-mode rejection is at least 100 dB at a gain of 10. These characteristics make the amplifier suitable for bridge-based sensors where small millivolt-level differential outputs must be measured accurately. The device operates from a single 1.8 V to 3.5 V supply according to the INA333 family specifications. Its rail-to-rail output stage permits the output voltage to approach the supply limits, improving utilization of low-voltage signal chains. A single external resistor sets the gain, simplifying implementation while preserving accurate differential amplification. The micro-power operating current supports battery-operated instrumentation where continuous sensor monitoring is required without excessive load. Typical uses include pressure and force transducers, thermocouple and RTD interfaces, biomedical instrumentation, portable measurement systems, and industrial process-control equipment. The -55°C to +210°C operating range distinguishes the SHKQ grade from the standard commercial INA333 variants and supports use in high-temperature measurement environments. When laying out an INA333SHKQ circuit, route the differential input and gain-resistor connections as short, symmetric traces, and place input filtering close to the source. Check common-mode input limits at the selected supply voltage because the allowable input range is not independent of supply. Confirm output headroom at the required gain and load, especially in low-voltage systems where rail-to-rail output behavior is important. This page combines the high-temperature INA333SHKQ specifications with application guidance, package information, engineering design notes, and a careful drop-in replacement assessment. It is intended to help engineers determine whether the device fits a precision sensing application without overlooking gain, temperature, supply, or PCB-footprint constraints.

詢價 聯絡我們
INA333SJD - Precision Micro-Power Instrumentation Amplifier | TI
INA333SJD

INA333SJD - Precision Micro-Power Instrumentation Amplifier | TI

Texas Instruments INA333SJD is a low-power, zero-drift, rail-to-rail-output instrumentation amplifier packaged in an 8-pin SOIC-8 (JD) package. Its headline characteristics include a 1.8 V to 5.5 V supply range, 150 kHz gain-bandwidth product, 10 µV offset voltage, and 2 nA input bias current. The device is intended for precision low-level sensor measurements where low offset, low drift, high common-mode rejection, and low input bias current are more important than wide bandwidth. An instrumentation amplifier is a differential-input amplifier designed to amplify a small voltage difference between two inputs while rejecting common-mode voltage. The INA333 belongs to the broader zero-drift amplifier family, combining an instrumentation-amplifier architecture with chopper-stabilized low-offset behavior. A zero-drift amplifier continuously corrects its own offset error, allowing low input-referred offset to remain stable over time and temperature. The INA333SJD supports gains of 1, 10, 100, and 1000 through its RG pin. Manufacturer specifications identify a maximum offset voltage of 25 µV at a gain of 100, offset drift of 0.2 µV/°C at a gain of 1000, input noise of 55 nV/√Hz at a gain of 100, and minimum common-mode rejection of 100 dB at a gain of 10. Its 0.16 V/µs slew rate supports relatively slow sensor signals without requiring a high-speed amplifier. The rail-to-rail output allows the output voltage to approach the supply rails, improving usable signal range in low-voltage systems. Gain is established by a single external resistor on the RG pin, simplifying circuit implementation while keeping the gain-setting component outside the amplifier. The measured gain error also depends on the tolerance and temperature coefficient of that resistor, so precision applications should use a suitable resistor network. Typical uses include bridge-based pressure and strain measurements, low-current sensors, biomedical instrumentation, industrial process monitoring, and portable sensor systems. The device is particularly useful when sensor output is small, common-mode voltage is substantial, and thermal offset variation would otherwise dominate the measurement. The principal design trade-off is bandwidth versus precision: the INA333 prioritizes low offset and low drift, while its 150 kHz gain-bandwidth product is modest compared with general-purpose high-speed amplifiers. Designers should also evaluate the high-temperature variant indicated by the INA333SJD ordering information and verify the complete electrical limits for the intended operating range. This product page consolidates the verified manufacturer and distributor details, identifies the practical benefits of zero-drift operation, and organizes the device's gains, noise, offset, supply, package, and application constraints for faster engineering selection.

詢價 聯絡我們
INA333SKGD1 - 50uA Zero-Drift Instrumentation Amp | TI
INA333SKGD1

INA333SKGD1 - 50uA Zero-Drift Instrumentation Amp | TI

The Texas Instruments INA333SKGD1 is a low-power, zero-drift, precision instrumentation amplifier with 50 uA quiescent current, rail-to-rail output, and a 1.8 V minimum supply in a bare-die package. Its three-operational-amplifier architecture supports differential signal conditioning with a single external gain-setting resistor. The INA333SKGD1 is suitable for precision bridge, current-sense, and sensor-amplification circuits where low offset and excellent common-mode rejection are important. An instrumentation amplifier is a specialized analog amplifier optimized for measuring small differential signals superimposed on a larger common-mode voltage. Its internal three-op-amp topology provides high input impedance, symmetric differential inputs, and adjustable gain without disturbing source impedance balance. Within the broader semiconductor hierarchy, it is a linear amplifier, analog IC, and signal-conditioning component used between sensors and ADCs. Key characteristics include an offset voltage as low as 25 uV at 25 degrees C for gains of 100 or greater, offset drift of 0.2 uV/degree C at gains of 100 or greater, and common-mode rejection of 100 dB at gains of 10 or greater. The gain equation is G = 1 + 100 kOhm divided by RG, allowing gains from 1 to 1000. A 0.16 V/us slew rate supports rapidly changing sensor waveforms without requiring the operating current of a high-power amplifier. The zero-drift architecture uses autocalibration techniques to reduce input-referred offset over time and temperature. This makes the device useful in battery-powered industrial sensors, portable medical equipment, and low-frequency precision measurement systems. The rail-to-rail output stage improves output-voltage range, while the low 50 uA supply current suits energy-limited equipment. Care is still required near the positive supply rail because output swing and common-mode range depend on supply voltage and load. Typical uses include strain-gauge bridge excitation, current shunt measurement, pressure and temperature sensing, biomedical instrumentation, and low-level differential ADC front ends. For bridge circuits, the instrument amplifier rejects common-mode voltage and preserves sensor balance. For current measurement, its high input impedance minimizes loading of the shunt and minimizes errors from unequal input impedance. For reliable operation, place the gain resistor close to RG, maintain symmetric input routing, and use low-noise supply and reference circuitry. Decouple each supply connection locally and verify input common-mode voltage and output swing against the actual supply limits. Use the manufacturer pin-description and die-layout information when assigning connections on the bare die. This product page combines manufacturer specifications, engineering application guidance, practical design considerations, lifecycle information, and a transparent assessment of replacement options. It also distinguishes the bare-die INA333SKGD1 from packaged INA333 variants so engineers can assess footprint and assembly implications before committing a design.

詢價 聯絡我們