INA326EA/250 - 1kHz Precision Instrumentation Amplifier | TI
MPN: INA326EA/250 ✓ 啟用中INA326EA/250 概覽
An instrumentation amplifier is a specialized analog amplifier optimized for measuring small differential signals while rejecting common-mode interference. Its internal architecture provides gain, differential sensing, and input common-mode rejection in one device. Within the broader hierarchy, an instrumentation amplifier is an amplifier IC and a precision signal-conditioning component used ahead of converters, sensors, and data-acquisition systems. The INA326 family is designed for systems requiring low drift, low noise, and rail-to-rail signal-chain flexibility.
Key characteristics include one amplifier channel, a 0.1 V/V to 1000 V/V programmable gain range, rail-to-rail inputs and outputs, a 2.7 V to 5.5 V supply range, and operation from -40 °C to 85 °C. The combination of 100 µV maximum input offset and 33 nV/√Hz typical noise supports accurate extraction of low-level differential signals. The 1 kHz gain-bandwidth characteristic makes the device suitable for precision rather than high-speed signal acquisition.
The INA326EA/250 uses a CMOS implementation to combine low input bias current, low offset voltage, and low drift with rail-to-rail input and output behavior. Because its output can approach the supply rails, downstream circuitry can use a wide portion of the available analog voltage range. Its programmable gain allows one device family to serve applications ranging from modest differential amplification to high-gain sensor conditioning while preserving the same 8-pin footprint.
Typical uses include bridge and strain-gauge signal conditioning, low-level current measurement, precision sensor interfaces, medical instrumentation, industrial process measurement, and data-acquisition front ends. The device is particularly appropriate when the target signal is differential, the common-mode environment is demanding, and measurement accuracy matters more than wideband throughput. A suitable analog-to-digital converter can then digitize the conditioned output.
A key design consideration is to preserve the differential nature of the input signal. Keep input routing compact, use symmetric interconnections where practical, and place the gain-setting resistor close to the RG pin. Follow the Texas Instruments datasheet pin-description table when assigning PCB tracks, and confirm that the selected gain, supply voltage, and output-swing requirements remain compatible with the intended sensor.
This page consolidates the Texas Instruments product characteristics, ordering information, package details, technical comparisons, and application guidance for engineers evaluating the INA326EA/250. It also organizes drop-in ordering options, practical design considerations, and search-focused technical information into one engineering reference.
直接替換替代品,適用於 INA326EA/250 — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
INA326EA/250G4
✅ 直接替換📋 參考替代品(不在目錄中)
INA326EA/250 最大額定值與電氣特性
| Product Type | Precision CMOS instrumentation amplifier, 1 amplifier channel |
| Supply Voltage Range | 2.7 V to 5.5 V |
| Gain Bandwidth | 1 kHz |
| Typical Gain Bandwidth | 114 dB at 1 kHz |
| Maximum Input Offset Voltage | 100 µV |
| Input Noise Density | 33 nV/√Hz typical at 1 kHz |
| Programmable Gain Range | 0.1 V/V to 1000 V/V |
| Input Common-Mode Capability | Rail-to-rail |
| Output Swing Capability | Rail-to-rail |
| Number of Channels | 1 channel |
| Technology | CMOS |
| 工作溫度範圍 | -40 °C to +85 °C |
| 封裝 | 8-pin VSSOP (DGK) |
| 安裝類型 | Surface mount |
| RoHS 狀態 | Compliant |
INA326EA/250 8-pin vssop (dgk) 腳位配置指南
INA326EA/250(8-pin vssop (dgk) 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: INA326EA/250.
請參閱 資料表 以查看完整腳位配置。
典型應用
INA326EA/250 適用於 6 應用s: Strain-Gauge and Bridge Sensor Conditioning, Precision Current Measurement, Medical and Diagnostic Instrumentation, Industrial Process Measurement, Data-Acquisition Front Ends, Portable Sensor and IoT Interfaces.
Strain-Gauge and Bridge Sensor Conditioning
The INA326EA/250 fits low-level bridge measurements where differential excitation produces a small output around a substantial common-mode voltage. Its rail-to-rail input operation, 100 µV maximum input offset voltage, and programmable gain from 0.1 V/V to 1000 V/V help preserve accuracy while amplifying the bridge imbalance. The device is normally placed between the bridge and an ADC, with the gain-setting resistor connected according to the manufacturer configuration. Keep bridge excitation and sense paths short and symmetrical to reduce pickup and imbalance error.
推薦
Precision Current Measurement
The INA326EA/250 can amplify the voltage generated by a current shunt or current-transformer secondary when the signal is differential and low amplitude. Its 33 nV/√Hz typical input noise and low offset support measurements where the useful signal is close to the amplifier noise and offset limits. Because it is a precision, 1 kHz-bandwidth device rather than a wideband amplifier, the application benefits most when the measured current changes slowly enough for accurate settling and filtering.
推薦
Medical and Diagnostic Instrumentation
The INA326EA/250 is appropriate for biomedical front ends that measure small differential sensor signals while rejecting interference from the surrounding environment. Rail-to-rail input and output capability provides useful signal range from a 2.7 V to 5.5 V supply, while the 100 µV maximum offset supports a low baseline error. For patient-connected or diagnostic equipment, engineers must also evaluate isolation, protection, leakage, safety, and applicable medical requirements separately from the amplifier's performance ratings.
推薦
Industrial Process Measurement
The INA326EA/250 supports low-level industrial sensor interfaces where a transducer produces a differential voltage and the controller requires accurate amplification before conversion. Its precision CMOS architecture, low-drift positioning, rail-to-rail I/O, and programmable gain suit pressure, temperature, and process-control signals. The 1 kHz gain-bandwidth characteristic limits high-speed transient capture, so the interface should include suitable filtering and ensure that amplifier settling meets the control-loop timing requirements.
推薦
Data-Acquisition Front Ends
The INA326EA/250 can serve as the analog gain stage immediately before an ADC in a precision data-acquisition channel. A gain of 0.1 V/V to 1000 V/V allows the same amplifier family to handle signals of different amplitudes, while the 114 dB typical gain bandwidth at 1 kHz supports accurate low-frequency measurements. Use close input routing, a compact gain resistor, and appropriate anti-alias filtering. The ADC selection should match the amplifier's output swing, bandwidth, noise, and conversion requirements.
推薦
Portable Sensor and IoT Interfaces
The INA326EA/250 is suitable for battery-powered sensor nodes when the sensor output is small and differential and the system operates from a low-voltage rail. Its supply range begins at 2.7 V, and rail-to-rail input and output behavior can improve utilization of the available voltage in compact designs. The precision nature of the amplifier makes it useful for environmental, wearable, and condition-monitoring nodes. Designers should account for supply noise, sensor excitation, ADC conversion time, and the amplifier's own current consumption when calculating battery life.
推薦
推薦產品摘要
工程參考資料,適用於 INA326EA/250 — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | INA326EA/250G4 |
|---|---|---|
| Package | 8-pin VSSOP (DGK) | 8-pin VSSOP (DGK) |
| Brand | Texas Instruments | Texas Instruments |
| Supply Voltage Range | 2.7 V to 5.5 V | 2.7 V to 5.5 V |
| Number of Channels | 1 channel | 1 channel |
| Programmable Gain Range | 0.1 V/V to 1000 V/V | 0.1 V/V to 1000 V/V |
| Maximum Input Offset Voltage | 100 µV | 100 µV |
| Input Noise Density | 33 nV/√Hz typical at 1 kHz | 33 nV/√Hz typical at 1 kHz |
| Gain Bandwidth | 1 kHz, with 114 dB typical gain bandwidth | 1 kHz, with 114 dB typical gain bandwidth |
| Input and Output Capability | Rail-to-rail input and output | Rail-to-rail input and output |
| Operating Temperature Range | -40 °C to +85 °C | -40 °C to +85 °C |
| Technology | Precision, low-drift CMOS | Precision, low-drift CMOS |
主要差異化特點
- Exact same electrical and package configuration (對比INA326EA/250G4)
- Rail-to-rail differential signal interface (對比INA326EA/250G4)
- Precision noise and offset performance (對比INA326EA/250G4)
設計說明
Route the two inputs as a compact differential pair and connect the gain-setting resistor directly to the RG pin with a short, low-inductance trace. Keep the input network close to the amplifier to minimize parasitic capacitance and susceptibility to coupled noise. For a bridge sensor, maintain symmetrical geometry between the excitation and sensing paths so that a small physical disturbance does not become a differential measurement error.
Do not select the gain solely to make the signal appear large. First verify the sensor's output range, common-mode voltage, required bandwidth, and allowable error, then check that the amplified output can settle within the system's input range. The device is optimized for precision, 1 kHz-bandwidth measurements; excessive gain can consume output swing or reduce usable bandwidth before conversion.
Place the device's supply decoupling capacitor next to the supply and ground pins, and use a short ground return to minimize supply ripple and ground bounce. Apply filtering after amplification when the bandwidth requirement permits it. Account for the amplifier's 33 nV/√Hz input noise, the gain-setting resistor's own thermal noise, and the ADC's input-referred noise when establishing an end-to-end noise target.
合規資訊
RoHS compliance is identified in the Mouser product listing. No additional REACH, halogen-free, conflict-minerals, or automotive qualification statement is confirmed.