AS7030B-COLM vs AS7030B 比較
詳細並排比較 AS7030B-COLM 由 ams-OSRAM 與 AS7030B 由 ams-OSRAM. 比較關鍵規格、電氣參數、封裝、生命週期狀態、價格與供貨情況,以找出最符合您設計需求的元件。
規格比較
| 參數 | AS7030B-COLM | AS7030B |
|---|---|---|
| 品牌 | ams-OSRAM | ams-OSRAM |
| 類別 | Motion Sensors | Motion Sensors |
| 生命週期狀態 | 啟用中 | 啟用中 |
| 感測器類型 | Optical biosensor module with embedded ECG channel (PPG + ECG) | — |
| Sensing Modalities | Photoplethysmography (PPG) and electrocardiogram (ECG) | — |
| Integrated Elements | LEDs, photodetectors, analog front-end (AFE), sequencer | — |
| Output Interface | I2C | — |
| I2C Slave Address | 0x30 (7-bit); 0x60 write / 0x61 read (8-bit) | — |
| Interrupt Output | Yes (INT pin) | — |
| ECG AFE Standard | Meets IEC 60601-2-47 requirements (per manufacturer) | — |
| 工作溫度 | -30C to +70C | [DATA_NEEDED: operating temperature range] |
| 封裝 | OLGA22 | — |
| Packaging Option | Tape & Reel (T&R) | — |
| 安裝類型 | Surface Mount | Surface Mount |
| Typical Applications | Fitness bands, smart watches, sports watches, smart patches | Fitness bands, smart watches, sports watches, smart patches |
| 供應電壓 | [DATA_NEEDED: supply voltage range] | [DATA_NEEDED: supply voltage range] |
| 供應電流 | [DATA_NEEDED: typical supply current] | [DATA_NEEDED: supply current] |
| LED Peak Wavelength | [DATA_NEEDED: LED wavelength configuration] | — |
| ADC Resolution | [DATA_NEEDED: ADC resolution] | [DATA_NEEDED: ADC resolution] |
| RoHS 狀態 | Compliant (LF / lead-free ordering code) | [DATA_NEEDED: RoHS status] |
| Product Type | — | Vital-sign biosensor module (PPG + ECG) |
| Measurement Functions | — | PPG (HRM/HRV/SpO2), ECG, GSR, skin temperature (via external NTC) |
| Communication Interface | — | I2C |
| Optical Elements | — | Integrated LEDs and photodiodes (multi-wavelength PPG) plus IR emitter with dedicated photodiode for proximity |
| Analog Front End | — | Low-noise ECG AFE with synchronous demodulator |
| Proximity Function | — | Yes (IR emitter + dedicated photodiode) |
| Ambient Light Rejection | — | Synchronous demodulation |
| PPG Sample Rate | — | [DATA_NEEDED: PPG sample rate] |
| ECG Channel Bandwidth | — | [DATA_NEEDED: ECG bandwidth] |
| Package / Ordering Code | — | AS7030B-COLM (module) |
| Evaluation Kits | — | AS7030B_EVALKIT_USB, AS7030B_EVALKIT_BT |