AD629BRZ-R7 - 270V Common-Mode Difference Amplifier | ADI
MPN: AD629BRZ-R7 ✓ 啟用中AD629BRZ-R7 概覽
A difference amplifier measures the voltage difference between two input terminals while rejecting voltage common to both inputs. This function places the AD629 within the broader hierarchy of differential amplifiers, analog signal-chain ICs, and precision instrumentation amplifiers. Unlike an isolation amplifier, the AD629 does not provide galvanic isolation, so its inputs and outputs share the circuit's normal ground reference.
The AD629's principal benefit is its very high input common-mode range of 270 V. That range allows small sensor, shunt, or bridge signals to be measured even when both input nodes are elevated by a large common-mode voltage. A 500 kHz gain-bandwidth product supports signal bandwidth needed in measurement systems, while the 2.1 V/µs slew rate helps the output track input steps without excessive slew distortion. The eight-pin SOIC implementation is suitable for conventional surface-mount PCB assembly.
The AD629 operates from a dual supply of up to ±18 V according to the manufacturer information identified for this family. Its high-voltage input capability is implemented using high-voltage-tolerant input structures, allowing the amplifier to remain connected to elevated common-mode nodes while powered from a conventional low-voltage supply. This distinction is important: high common-mode input tolerance does not mean that the supply pins accept high voltage.
Typical uses include high-voltage bus current sensing, power-converter feedback monitoring, industrial process instrumentation, motor-control systems, and precision test equipment. In these systems, the AD629 can convert a small differential measurement across a shunt or bridge into a ground-referenced amplifier output while reducing the influence of common-mode voltage. Resistor-network gain and external filtering remain important parts of the overall signal-chain design.
Careful layout and signal integrity are essential because very small differential inputs must be preserved in the presence of potentially large common-mode voltages. Input traces should be short, matched where practical, and routed away from switching nodes and high-current paths. The input and feedback resistors should preserve the selected differential gain while keeping parasitic resistance and capacitance balanced.
This product page combines the manufacturer's device description with package, substitution, application, and design guidance. It also distinguishes confirmed direct substitutions from candidates whose exact pinout, package, or lifecycle status still requires engineering review before a production change is approved.
直接替換替代品,適用於 AD629BRZ-R7 — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: AD629BRZ-R7 (相同外形與佔位) — 差異在於 Operating Temperature Range, Package, RoHS Status, Slew Rate, Amplifier Type.
AD629BRZ
✅ 直接替換聯絡詢價
查看資料表 →AD629ARZ
✅ 直接替換聯絡詢價
查看資料表 →AD629BRZ-RL
✅ 直接替換聯絡詢價
查看資料表 →AD629BRZ-R7 最大額定值與電氣特性
| Product Type | Precision difference amplifier |
| Number of Circuits | 1 circuit |
| Input Common-Mode Voltage Range | Up to 270 V |
| Supply Voltage Range | ±18 V |
| Gain-Bandwidth Product | 500 kHz |
| Slew Rate | 2.1 V/µs |
| Amplifier Type | Difference amplifier |
| 封裝 | 8-lead SOIC |
| 安裝類型 | Surface mount |
AD629BRZ-R7 8-lead soic 腳位配置指南
AD629BRZ-R7(8-lead soic 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: AD629BRZ-R7.
請參閱 資料表 以查看完整腳位配置。
典型應用
AD629BRZ-R7 適用於 6 應用s: High-Side Current Sensing, Power Converter Feedback, Industrial Bridge Sensing, Motor Drive Current Monitoring, Battery Pack Monitoring, Precision Test and Measurement.
High-Side Current Sensing
The AD629BRZ-R7 fits high-side current measurement because its input common-mode range reaches 270 V while it extracts the small differential voltage generated across a power shunt. The 500 kHz gain-bandwidth product can accommodate measurement signals beyond DC, and the 2.1 V/µs slew rate allows the output to follow transients more effectively than a slow precision amplifier. Place the shunt amplifier in a Kelvin connection and route the small differential pair away from switching-node copper. The major trade-off is that the AD629 does not provide galvanic isolation, so the power-domain voltage must remain within the device's specified ratings.
推薦
Power Converter Feedback
The AD629BRZ-R7 can measure small feedback voltages in power-converter systems where the sensing nodes may be elevated far above ground. Its 270 V common-mode capability avoids forcing the feedback network into the low-voltage region, while the difference-amplifier function rejects voltage shared by both sensing points. The 500 kHz bandwidth supports closed-loop and supervisory measurements, and the 2.1 V/µs slew rate helps reproduce faster converter events. Layout must isolate the high dv/dt switching node from the sensitive input pair and maintain symmetrical resistance in the feedback network.
推薦
Industrial Bridge Sensing
The AD629BRZ-R7 is appropriate for bridge-based industrial sensing when both bridge inputs are driven by a substantial common-mode voltage. The amplifier measures the small differential bridge excitation while rejecting the larger voltage appearing at both inputs, providing a more useful result for an ADC or controller. Its 270 V common-mode range provides headroom for industrial buses and process equipment, while its 500 kHz bandwidth preserves faster dynamic information. The application remains sensitive to resistor tolerance and thermal drift, so the gain network and input routing should be designed for the required measurement accuracy.
推薦
Motor Drive Current Monitoring
The AD629BRZ-R7 can monitor the voltage across a motor-phase shunt in a drive system because the phase current path may place both shunt terminals at a high common-mode voltage. The device's 270 V input common-mode range makes it suitable for such elevated sensing nodes, and its 500 kHz gain-bandwidth product supports current waveforms beyond static measurements. The 2.1 V/µs slew rate assists during abrupt load changes. Kelvin routing, common-mode transient protection, and separation from motor-switching nodes are necessary because the useful differential signal is much smaller than the switching voltage.
推薦
Battery Pack Monitoring
The AD629BRZ-R7 can condition small differential measurements from cells or taps in a multi-cell battery system where the sensing nodes can be several volts or more above ground. Its 270 V common-mode range provides substantial margin for elevated pack buses, while the difference-amplifier topology emphasizes cell or shunt voltage rather than the common pack potential. The 500 kHz bandwidth can capture load transients when configured with suitable external gain and filtering. Protection, cell-balancing topology, and the exact battery maximum voltage must be evaluated before connecting the amplifier.
推薦
Precision Test and Measurement
The AD629BRZ-R7 is useful in test and measurement equipment that must detect small differential signals riding on a large common-mode voltage. Its precision difference-amplifier architecture allows the input pair to remain above ground while the output is presented relative to the system ground, and its 500 kHz bandwidth supports more than static voltage measurements. The 2.1 V/µs slew rate reduces distortion when the measured differential signal changes rapidly. Calibration should account for gain-network tolerance, input offset, and the relationship between the selected external resistors and the resulting full-scale output range.
推薦
推薦產品摘要
工程參考資料,適用於 AD629BRZ-R7 — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | AD629BRZ | AD629ARZ | AD629BRZ-RL |
|---|---|---|---|---|
| Package | 8-lead SOIC | 8-lead SOIC | 8-lead SOIC | 8-lead SOIC |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Product Type | Precision difference amplifier | Precision difference amplifier | Precision signal processing amplifier | Precision difference amplifier |
| Number of Channels | 1 circuit | 1 circuit | 1 circuit | 1 circuit |
| Order or Shipment Format | AD629BRZ-R7 | AD629BRZ | AD629ARZ | AD629BRZ-RL |
| Special Features | High common-mode voltage range; can replace costly isolation amplifiers where isolation is not required | Functionally equivalent core specifications and pinout | Same AD629 series and compared 500 kHz bandwidth | Identical electrical specifications with different packing format |
主要差異化特點
- High common-mode measurement capability (對比INA117P)
- Direct family-level footprint reuse (對比AD629BRZ)
- Electrical equivalence with flexible reel ordering (對比AD629BRZ-RL)
- Bandwidth suitable for dynamic differential measurements (對比AD629ARZ)
設計說明
Route the two input conductors as a close, matched pair and use Kelvin connections from the shunt or bridge whenever possible. High common-mode capability does not eliminate sensitivity to unequal parasitic resistance, capacitance, and coupled noise. Keep the input network close to the amplifier, avoid long loops around the measurement path, and maintain a continuous ground reference. Sensitive traces should remain separated from power-switching nodes and high-current copper.
Select the external gain resistors to produce the required output without approaching the output-voltage or supply-current limits. Keep the two feedback paths symmetric so parasitic capacitance does not convert common-mode edges into differential error. Place filtering capacitors on the appropriate amplifier nodes after accounting for their effect on gain and stability. Use the manufacturer's recommended values rather than substituting capacitors solely by capacitance value.
Do not interpret the 270 V common-mode rating as permission to apply 270 V to the supply pins. The amplifier is powered from a dual supply of up to ±18 V, while the high-voltage tolerance applies to the input nodes. Also verify that shutdown, input protection, and external circuitry do not introduce leakage that materially changes the measured difference. An isolation amplifier is required when galvanic isolation is part of the system specification.
Keep the high-voltage input path physically separated from switching converter loops because common-mode transitions can couple into the differential measurement even when the desired differential voltage is small. Use a compact ground-reference layout, minimize exposed input-node area, and consider filtering only after confirming the required measurement bandwidth. Changes to input capacitance or an unmatched filter can degrade CMRR and create an unintended differential transient.
合規資訊
The accessible manufacturer and distributor information does not provide a definitive compliance declaration for this exact order code. Confirm RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals status in the current manufacturer product documentation before release.