AD629BRZ-R7 - 270V Common-Mode Difference Amplifier | ADI
料号: AD629BRZ-R7 ✓ 量产中AD629BRZ-R7 概述
A difference amplifier measures the voltage difference between two input terminals while rejecting voltage common to both inputs. This function places the AD629 within the broader hierarchy of differential amplifiers, analog signal-chain ICs, and precision instrumentation amplifiers. Unlike an isolation amplifier, the AD629 does not provide galvanic isolation, so its inputs and outputs share the circuit's normal ground reference.
The AD629's principal benefit is its very high input common-mode range of 270 V. That range allows small sensor, shunt, or bridge signals to be measured even when both input nodes are elevated by a large common-mode voltage. A 500 kHz gain-bandwidth product supports signal bandwidth needed in measurement systems, while the 2.1 V/µs slew rate helps the output track input steps without excessive slew distortion. The eight-pin SOIC implementation is suitable for conventional surface-mount PCB assembly.
The AD629 operates from a dual supply of up to ±18 V according to the manufacturer information identified for this family. Its high-voltage input capability is implemented using high-voltage-tolerant input structures, allowing the amplifier to remain connected to elevated common-mode nodes while powered from a conventional low-voltage supply. This distinction is important: high common-mode input tolerance does not mean that the supply pins accept high voltage.
Typical uses include high-voltage bus current sensing, power-converter feedback monitoring, industrial process instrumentation, motor-control systems, and precision test equipment. In these systems, the AD629 can convert a small differential measurement across a shunt or bridge into a ground-referenced amplifier output while reducing the influence of common-mode voltage. Resistor-network gain and external filtering remain important parts of the overall signal-chain design.
Careful layout and signal integrity are essential because very small differential inputs must be preserved in the presence of potentially large common-mode voltages. Input traces should be short, matched where practical, and routed away from switching nodes and high-current paths. The input and feedback resistors should preserve the selected differential gain while keeping parasitic resistance and capacitance balanced.
This product page combines the manufacturer's device description with package, substitution, application, and design guidance. It also distinguishes confirmed direct substitutions from candidates whose exact pinout, package, or lifecycle status still requires engineering review before a production change is approved.
直接替换替代料: AD629BRZ-R7 ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: AD629BRZ-R7 (相同外形与封装尺寸) ——差异在于 Operating Temperature Range, Package, RoHS Status, Slew Rate, Amplifier Type.
AD629BRZ
✅ 直接替换联系询价
查看数据手册 →AD629ARZ
✅ 直接替换联系询价
查看数据手册 →AD629BRZ-RL
✅ 直接替换联系询价
查看数据手册 →AD629BRZ-R7 最大额定值与电气特性
| Product Type | Precision difference amplifier |
| Number of Circuits | 1 circuit |
| Input Common-Mode Voltage Range | Up to 270 V |
| Supply Voltage Range | ±18 V |
| Gain-Bandwidth Product | 500 kHz |
| Slew Rate | 2.1 V/µs |
| Amplifier Type | Difference amplifier |
| 封装 | 8-lead SOIC |
| 安装类型 | Surface mount |
AD629BRZ-R7 8-lead soic 引脚配置指南
AD629BRZ-R7(8-lead soic 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: AD629BRZ-R7.
请参阅 数据手册 以查看完整引脚配置。
典型应用
AD629BRZ-R7 适用于 6 应用s: High-Side Current Sensing, Power Converter Feedback, Industrial Bridge Sensing, Motor Drive Current Monitoring, Battery Pack Monitoring, Precision Test and Measurement.
High-Side Current Sensing
The AD629BRZ-R7 fits high-side current measurement because its input common-mode range reaches 270 V while it extracts the small differential voltage generated across a power shunt. The 500 kHz gain-bandwidth product can accommodate measurement signals beyond DC, and the 2.1 V/µs slew rate allows the output to follow transients more effectively than a slow precision amplifier. Place the shunt amplifier in a Kelvin connection and route the small differential pair away from switching-node copper. The major trade-off is that the AD629 does not provide galvanic isolation, so the power-domain voltage must remain within the device's specified ratings.
推荐
Power Converter Feedback
The AD629BRZ-R7 can measure small feedback voltages in power-converter systems where the sensing nodes may be elevated far above ground. Its 270 V common-mode capability avoids forcing the feedback network into the low-voltage region, while the difference-amplifier function rejects voltage shared by both sensing points. The 500 kHz bandwidth supports closed-loop and supervisory measurements, and the 2.1 V/µs slew rate helps reproduce faster converter events. Layout must isolate the high dv/dt switching node from the sensitive input pair and maintain symmetrical resistance in the feedback network.
推荐
Industrial Bridge Sensing
The AD629BRZ-R7 is appropriate for bridge-based industrial sensing when both bridge inputs are driven by a substantial common-mode voltage. The amplifier measures the small differential bridge excitation while rejecting the larger voltage appearing at both inputs, providing a more useful result for an ADC or controller. Its 270 V common-mode range provides headroom for industrial buses and process equipment, while its 500 kHz bandwidth preserves faster dynamic information. The application remains sensitive to resistor tolerance and thermal drift, so the gain network and input routing should be designed for the required measurement accuracy.
推荐
Motor Drive Current Monitoring
The AD629BRZ-R7 can monitor the voltage across a motor-phase shunt in a drive system because the phase current path may place both shunt terminals at a high common-mode voltage. The device's 270 V input common-mode range makes it suitable for such elevated sensing nodes, and its 500 kHz gain-bandwidth product supports current waveforms beyond static measurements. The 2.1 V/µs slew rate assists during abrupt load changes. Kelvin routing, common-mode transient protection, and separation from motor-switching nodes are necessary because the useful differential signal is much smaller than the switching voltage.
推荐
Battery Pack Monitoring
The AD629BRZ-R7 can condition small differential measurements from cells or taps in a multi-cell battery system where the sensing nodes can be several volts or more above ground. Its 270 V common-mode range provides substantial margin for elevated pack buses, while the difference-amplifier topology emphasizes cell or shunt voltage rather than the common pack potential. The 500 kHz bandwidth can capture load transients when configured with suitable external gain and filtering. Protection, cell-balancing topology, and the exact battery maximum voltage must be evaluated before connecting the amplifier.
推荐
Precision Test and Measurement
The AD629BRZ-R7 is useful in test and measurement equipment that must detect small differential signals riding on a large common-mode voltage. Its precision difference-amplifier architecture allows the input pair to remain above ground while the output is presented relative to the system ground, and its 500 kHz bandwidth supports more than static voltage measurements. The 2.1 V/µs slew rate reduces distortion when the measured differential signal changes rapidly. Calibration should account for gain-network tolerance, input offset, and the relationship between the selected external resistors and the resulting full-scale output range.
推荐
推荐产品汇总
工程参考数据: AD629BRZ-R7 ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | AD629BRZ | AD629ARZ | AD629BRZ-RL |
|---|---|---|---|---|
| Package | 8-lead SOIC | 8-lead SOIC | 8-lead SOIC | 8-lead SOIC |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Product Type | Precision difference amplifier | Precision difference amplifier | Precision signal processing amplifier | Precision difference amplifier |
| Number of Channels | 1 circuit | 1 circuit | 1 circuit | 1 circuit |
| Order or Shipment Format | AD629BRZ-R7 | AD629BRZ | AD629ARZ | AD629BRZ-RL |
| Special Features | High common-mode voltage range; can replace costly isolation amplifiers where isolation is not required | Functionally equivalent core specifications and pinout | Same AD629 series and compared 500 kHz bandwidth | Identical electrical specifications with different packing format |
关键差异点
- High common-mode measurement capability (对比 INA117P)
- Direct family-level footprint reuse (对比 AD629BRZ)
- Electrical equivalence with flexible reel ordering (对比 AD629BRZ-RL)
- Bandwidth suitable for dynamic differential measurements (对比 AD629ARZ)
设计说明
Route the two input conductors as a close, matched pair and use Kelvin connections from the shunt or bridge whenever possible. High common-mode capability does not eliminate sensitivity to unequal parasitic resistance, capacitance, and coupled noise. Keep the input network close to the amplifier, avoid long loops around the measurement path, and maintain a continuous ground reference. Sensitive traces should remain separated from power-switching nodes and high-current copper.
Select the external gain resistors to produce the required output without approaching the output-voltage or supply-current limits. Keep the two feedback paths symmetric so parasitic capacitance does not convert common-mode edges into differential error. Place filtering capacitors on the appropriate amplifier nodes after accounting for their effect on gain and stability. Use the manufacturer's recommended values rather than substituting capacitors solely by capacitance value.
Do not interpret the 270 V common-mode rating as permission to apply 270 V to the supply pins. The amplifier is powered from a dual supply of up to ±18 V, while the high-voltage tolerance applies to the input nodes. Also verify that shutdown, input protection, and external circuitry do not introduce leakage that materially changes the measured difference. An isolation amplifier is required when galvanic isolation is part of the system specification.
Keep the high-voltage input path physically separated from switching converter loops because common-mode transitions can couple into the differential measurement even when the desired differential voltage is small. Use a compact ground-reference layout, minimize exposed input-node area, and consider filtering only after confirming the required measurement bandwidth. Changes to input capacitance or an unmatched filter can degrade CMRR and create an unintended differential transient.
合规信息
The accessible manufacturer and distributor information does not provide a definitive compliance declaration for this exact order code. Confirm RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals status in the current manufacturer product documentation before release.