AD629BRZ-RL - ±270V High Common-Mode Difference Amp | ADI
MPN: AD629BRZ-RL ✓ ActiveAD629BRZ-RL Overview
A difference amplifier measures the voltage difference between two inputs while attenuating signals common to both inputs. This function is essential when a useful sensor signal occupies only a small differential range but is superimposed on a much larger voltage. Within the broader hierarchy, the AD629 is a difference amplifier, a specialized amplifier topology, and ultimately a signal-conditioning semiconductor used ahead of precision converters, meters, and control systems.
The AD629’s principal advantage is its high common-mode range. A ±270 V input capability allows measurement at a high-side bus, motor terminal, or industrial supply without requiring the signal to remain near ground. Input protection extends to ±500 V in both common-mode and differential modes, improving robustness in electrically noisy environments. The 96 dB CMRR specification suppresses common-mode voltage errors, while the 2.1 V/µs slew rate supports accurate response to changing differential waveforms.
The AD629 is intended for precision signal conditioning rather than general-purpose voltage amplification. Its architecture emphasizes rejection of large common-mode voltages and protection of sensitive measurement inputs. This makes it useful when a shunt or sensing network operates at a high bus voltage and the downstream instrument must recover only the small differential voltage. The 8-SOIC package supports conventional surface-mount assembly and compact analog boards.
Typical uses include high-side current measurement in motor controls, battery-management systems, industrial power monitors, photovoltaic inverters, and instrumentation. In these systems, the amplifier can process a shunt-derived differential signal while the inputs remain exposed to substantial common-mode voltage. Its role is to improve signal integrity before an ADC, controller, or analog-to-digital conversion stage.
Design attention should center on maintaining the required differential and common-mode limits, providing adequate supply bypassing, and observing the absolute maximum ratings. Because high-voltage inputs are involved, trace spacing, guarding, connectors, and isolation from sensitive low-level nodes require deliberate PCB planning. The signal path should also preserve the accuracy expected from the AD629 rather than allowing copper resistance or leakage to become the dominant error source.
This product page combines manufacturer specifications, verified package and ordering information, drop-in alternatives, and practical design guidance for engineers evaluating the AD629BRZ-RL. It supports faster part selection for high-voltage measurement designs while highlighting the common-mode range, protection limits, package constraints, and application-specific trade-offs that determine whether the device is suitable for a particular board.
Drop-in alternatives for AD629BRZ-RL — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.
Variants in this series
Same-series models that are drop-in compatible with AD629BRZ-RL (same form factor and footprint) — differing in Package, Operating Temperature Range, Product Type, Supply Voltage Range, Slew Rate.
AD629BRZ-R7
✅ Drop-InContact for price
View Datasheet →AD629BRZ
✅ Drop-InContact for price
View Datasheet →AD629ARZ
✅ Drop-InContact for price
View Datasheet →AD629ARZ-RL
✅ Drop-InContact for price
View Datasheet →INA117KU
✅ Drop-InContact for price
View Datasheet →AD629BRZ-RL Maximum Ratings & Electrical Characteristics
| Product Type | Precision difference amplifier |
| Channel Count | 1 channel |
| Common-Mode Voltage Range | ±270 V |
| Common-Mode Input Protection | ±500 V |
| Differential Input Protection | ±500 V |
| Supply Voltage | 15 V |
| Wide Power Supply Range | ±10 V |
| Common-Mode Rejection Ratio | 96 dB |
| Slew Rate | 2.1 V/µs |
| Gain-Bandwidth Product | 500 kHz |
| Operating Temperature Range | -40 °C to +85 °C |
| Package Type | 8-lead SOIC, MS-012AA |
| Number of Pins | 8 pins |
| Mounting Type | Surface mount |
| Input Protection | ±500 V common-mode and ±500 V differential-mode |
| RoHS Status | unknown |
| REACH Status | unknown |
AD629BRZ-RL 8-lead soic, ms-012aa Pin Configuration Guide
Pin configuration for AD629BRZ-RL (8-lead soic, ms-012aa package). This analog component features input, output, and power supply pins. Refer to the manufacturer datasheet for offset null, compensation, and enable pin configurations. Ideal for signal conditioning and amplifier circuits.
No detailed pinout data available for AD629BRZ-RL.
Refer to the datasheet for full pin configuration.
Typical Applications
AD629BRZ-RL is suitable for 6 applications: High-Side DC Motor Current Sensing, Industrial Power-Supply Monitoring, Battery Pack Current Measurement, Photovoltaic Inverter Current Control, Power-Distribution and Protection Systems, Precision Instrumentation and Test Equipment.
High-Side DC Motor Current Sensing
The AD629BRZ-RL fits high-side motor-current monitoring because its ±270 V common-mode range can accommodate a shunt placed in a high-voltage motor bus while the amplifier recovers only the shunt’s differential voltage. With 96 dB CMRR, it suppresses much of the common-mode disturbance produced by motor switching, while ±500 V input protection improves tolerance to transients. Use the device ahead of an ADC or controller, keep the shunt bandwidth within the amplifier’s 500 kHz gain-bandwidth product, and design separate filtering and clamping for switching-node energy. The important trade-off is that a 2.1 V/µs slew rate favors low-frequency current control more than high-bandwidth PWM analysis.
Recommended
Industrial Power-Supply Monitoring
AD629BRZ-RL is appropriate for industrial supply and protection systems where the voltage of interest is superimposed on a high bus potential. Its ±270 V common-mode capability permits direct sensing of a shunt or differential network without first reducing the bus voltage, while 96 dB CMRR limits the influence of common-mode noise. The measured signal can feed instrumentation, protection logic, or an ADC such as AD7453. Engineers should allow the full common-mode range when specifying connectors and trace spacing, and should verify that the ±10 V supply arrangement provides adequate headroom for the required output swing. The amplifier is most valuable where small differential accuracy matters more than compactness or minimum power consumption.
Recommended
Battery Pack Current Measurement
The AD629BRZ-RL can support accurate high-side current measurement in battery packs when cells or a bus rail operate above ground. Its ±270 V common-mode input range keeps the shunt amplifier functional even as the battery voltage changes, and 96 dB CMRR helps preserve measurement accuracy when the common-mode voltage is large relative to the shunt drop. The output can be routed to a precision converter such as AD780 for telemetry or AD7453 for a dedicated measurement channel. Designers must still implement cell-balancing protection outside the amplifier, observe the -40 °C to +85 °C rating, and account for the fixed 2.1 V/µs slew rate when estimating response time during rapid current transients.
Recommended
Photovoltaic Inverter Current Control
AD629BRZ-RL suits photovoltaic inverter current-control loops where a shunt is located in a high-side DC link and the amplifier must reject the changing bus voltage. The ±270 V common-mode range removes the need for an intermediate high-voltage attenuator, while the 96 dB CMRR specification helps prevent bus movement from appearing directly at the measurement output. A precision ADC such as AD7453 can sample the conditioned signal for control and protection. The 500 kHz gain-bandwidth product supports moderate-bandwidth current loops, but the 2.1 V/µs slew rate should be checked against the fastest expected inverter transient. High-voltage PCB creepage and input filtering remain essential outside the device itself.
Recommended
Power-Distribution and Protection Systems
AD629BRZ-RL can measure differential voltage in high-side power-distribution paths where bus transients and large common-mode levels are expected. Its ±500 V input protection ratings add margin around a precision measurement element, and the ±270 V operating common-mode range allows the signal-conditioning stage to remain close to the sensed node. A controller or ADC can use the output for overload reporting, energy accounting, or fault detection. The amplifier should not replace dedicated surge protection, fuses, or isolation barriers; it is the precision measurement element after those functions. Layout must keep high-voltage and low-level paths separated, and the supply rails should be filtered and decoupled to prevent converter noise from degrading the 96 dB common-mode rejection performance.
Recommended
Precision Instrumentation and Test Equipment
AD629BRZ-RL is useful in instrumentation that measures small differential voltages at elevated common-mode potentials, particularly where a conventional low-voltage amplifier would saturate. Its 96 dB CMRR reduces the influence of common-mode sources, while the 2.1 V/µs slew rate and 500 kHz gain-bandwidth product support accurate sensing across a broad range of industrial test waveforms. The output can drive a precision ADC such as AD7453 for digital instrumentation. Because the device is specified for -40 °C to +85 °C operation, enclosure temperature and self-heating must remain within that range. Component tolerance and the gain-setting network should also be evaluated carefully when traceable measurement accuracy is more important than simple current detection.
Recommended
Recommended Products Summary
Engineering reference data for AD629BRZ-RL — comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product | AD629BRZ-R7 | AD629BRZ | AD629ARZ | AD629ARZ-RL | INA117KU |
|---|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Texas Instruments |
| Package | 8-SOIC | 8-SOIC - same | 8-SOIC - same | 8-SOIC - same | 8-SOIC - same | 8-SOIC - same |
Key Differentiators
- Higher common-mode rejection in the AD629 ordering comparison (vs AD629ARZ)
- Direct same-family replacement with unchanged electrical ratings (vs AD629BRZ-R7)
- High-voltage input protection integrated into the measurement amplifier (vs INA117KU)
- Precision current-sense conditioning with a defined 500 kHz bandwidth (vs AD629BRZ)
Design Notes
Treat the AD629BRZ-RL input network as a high-voltage analog path even though the amplifier is supplied from ±10 V rails. Maintain generous copper-to-copper clearance around input and supply pins, avoid placing sensitive low-level traces beneath the device, and use guard structures where board contamination could affect leakage. Place input-protection and filtering components close to the pins, while keeping their voltage rating and pulse tolerance appropriate for the measured bus. The 8-SOIC land pattern must match the official package drawing, including lead pitch and exposed geometry if any.
Keep the differential input route compact and matched in proportion to the gain implemented around the AD629. The device’s 96 dB CMRR reduces common-mode error, but unequal input impedance, leakage, parasitic capacitance, and ground currents can still unbalance a small shunt signal. Use guarding and clean reference-ground connections, and route the output directly toward the next ADC or filter stage rather than across switching-power nodes. Confirm that the 500 kHz gain-bandwidth product and 2.1 V/µs slew rate provide enough bandwidth and settling behavior for the intended loop.
Decouple each supply rail close to the appropriate package pin and maintain a quiet return path so converter ripple does not degrade measurement accuracy. The AD629BRZ-RL uses a ±10 V supply arrangement; verify output swing, input common-mode operation, and supply sequencing against the Analog Devices manufacturer datasheet before finalizing the bias network. Do not interpret the ±500 V input-protection rating as permission to exceed the operating common-mode range or to omit upstream surge protection. Add external clamps where transient energy could exceed the device’s recommended limits.
A frequent design mistake is applying ordinary low-voltage current-sense amplifier rules to the AD629BRZ-RL. Its ±270 V common-mode capability is an operating specification, not a general permission for arbitrary overvoltage, and the protected input still requires a correctly scaled shunt and network. Another mistake is assuming that high CMRR eliminates errors caused by unbalanced gain-setting resistors or input leakage. Check resistor tolerances, source impedance, grounding, and temperature drift together with the amplifier’s 96 dB CMRR and 2.1 V/µs slew rate.
Compliance Information
No definitive RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status was established for the exact ordering code.