A dual-standard line transceiver is an interface IC that bridges low-voltage digital logic and differential or unbalanced serial communications. RS-232 uses single-ended signaling for point-to-point connections, while RS-422 uses differential signaling for longer, noise-resistant links. The AD7306JRZ combines both standards in one monolithic device, allowing one PCB design to support different cable ports without changing the integrated-circuit footprint.
Key characteristics include operation from a single 5 V supply, three transmit channels, three receive channels, operation to 5 Mbit/s, and a commercial temperature grade. Its 24-lead plastic SOIC package provides a conventional gull-wing surface-mount footprint. The configurable receiver path allows the unused receiver to be assigned to either an RS-232 or RS-422 input, reducing external switching and conserving board area.
The mixed RS-232 and RS-422 architecture supports legacy industrial equipment, instrumentation, point-of-sale terminals, barcode scanners, embedded controllers, and computer peripherals. A system can use the RS-232 drivers for short single-ended ports and the RS-422 driver and receiver for a longer balanced connection. The three-driver, three-receiver arrangement is useful when a peripheral requires multiple serial ports or when transmit and receive lines are not all used simultaneously.
Circuit design requires careful treatment of RS-232 and RS-422 because their electrical layers differ. RS-232 normally uses bipolar signal levels, whereas RS-422 is differential and normally requires termination at the receiver. Keep high-current driver returns away from sensitive logic ground paths, provide stable supply decoupling at the IC, and follow the manufacturer pin and grounding guidance when implementing both standards on one board.
This product guidance helps engineers distinguish the AD7306JRZ from general-purpose multi-driver interface ICs by focusing on its 5 V operation, three transmitters, three receivers, commercial grade, and 24-SOIC pinout. It also provides practical guidance for RS-232/RS-422 port implementation, package reuse, and direct interface decisions.
直接替換替代品,適用於 AD7306JRZ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
AD7306ARZ
✅ 直接替換聯絡詢價
查看資料表 →AD7306AN
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
AD7306BRZ
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
AD7306CRZ
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
AD7306ERZ
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
AD7306JRZ 最大額定值與電氣特性
| Product Type | RS-232 and RS-422 line transceiver |
| 供應電壓 | 5 V |
| Transmitter Count | 3 |
| Receiver Count | 3 |
| RS-232 Driver Count | 2 |
| RS-422 Driver Count | 1 |
| RS-232 Receiver Count | 1 |
| Configurable Receiver Path Count | 1 |
| Maximum Data Rate | 5 Mbit/s |
| Logic Interface | TTL signal levels |
| Supported Standards | EIA RS-232 and EIA RS-422 |
| Temperature Grade | Commercial |
| 封裝 | 24-lead SOIC |
| Terminal Form | Gull wing |
| 安裝類型 | Surface mount |
AD7306JRZ 24-lead soic 腳位配置指南
AD7306JRZ(24-lead soic 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: AD7306JRZ.
請參閱 資料表 以查看完整腳位配置。
典型應用
AD7306JRZ 適用於 6 應用s: Industrial Serial Port Interface, Instrumentation and Test Equipment, Embedded Control and Data Acquisition, Point-of-Sale and Peripheral Connectivity, Telecommunications and Network Equipment, Medical and Diagnostic Equipment.
Industrial Serial Port Interface
The AD7306JRZ fits industrial controller and data-acquisition equipment that must communicate through both RS-232 and RS-422. Its 5 V supply operation, two RS-232 drivers, one RS-422 driver, and three receiver paths provide flexible channel allocation in a single 24-SOIC footprint. The RS-422 channel can support a longer differential connection, while the RS-232 channels suit shorter single-ended links to sensors or legacy modules. Design the interface so ground returns and cable routing prevent switching or surge transients from coupling into adjacent logic, and verify termination and protection requirements for the actual RS-422 cable length.
推薦
Instrumentation and Test Equipment
The AD7306JRZ is appropriate for laboratory instruments that expose a mix of legacy RS-232 equipment ports and a balanced RS-422 connection. Three transmitters and three receivers allow the instrument to support several control or measurement links while maintaining a single 5 V interface supply. The device operates to 5 Mbit/s, providing useful margin for instrument-control traffic. Keep the transceiver close to the external connector and protection network, separate noisy return currents from precision analog grounds, and validate the logic thresholds and line behavior under the cable and equipment grounding conditions expected in service.
推薦
Embedded Control and Data Acquisition
The AD7306JRZ can connect a microcontroller or embedded processor to equipment using TTL logic on one side and RS-232 or RS-422 on the other. Its 3/3 channel organization is useful when a controller needs bidirectional communication across several serial links or supports both an RS-232 service port and an RS-422 field bus. The 5 V interface arrangement simplifies integration with systems that already use regulated 5 V. Confirm logic-level compatibility, configure unused channels according to the manufacturer guidance, and use the pin-description table to avoid assigning the configurable receiver path incorrectly.
推薦
Point-of-Sale and Peripheral Connectivity
The AD7306JRZ supports point-of-sale terminals, scanners, printers, and other peripherals that retain RS-232 connections while an equipment enclosure also needs a balanced RS-422 link. Two RS-232 drivers can address separate peripherals, and the remaining transmitter supports RS-422, while the receivers provide return paths for equipment control. The 24-SOIC package is practical for a conventional multilayer PCB and is easier to route than multiple separate interface packages. Place surge protection close to the connector, maintain recommended return-path geometry, and avoid long unprotected traces from the connector to the transceiver.
推薦
Telecommunications and Network Equipment
The AD7306JRZ can serve as a legacy interface bridge in telecommunications equipment that combines RS-232 control signaling with RS-422 communications. The RS-232 receiver handles single-ended control signals, while the differential RS-422 driver supports a balanced link over a longer cable run. The device's three transmitters and three receivers provide channel flexibility for console, alarm, and peripheral interfaces within one package. Designers should apply connector-level surge protection, observe the recommended RS-422 termination arrangement, and keep high-energy return paths separated from sensitive receiver grounds to maintain reliable operation.
推薦
Medical and Diagnostic Equipment
The AD7306JRZ can provide legacy serial connectivity in medical or diagnostic equipment that must communicate with RS-232 accessories and RS-422 instruments. Its 5 V supply, three transmitters, and three receivers allow several isolated-by-protocol communication paths to coexist in a compact 24-SOIC footprint. The commercial temperature grade may suit controlled indoor equipment, but it must be checked against the actual enclosure environment. Use appropriately rated protection networks at external connectors, maintain clean grounding between the interface and sensitive sections, and validate every cable-connected port for its intended electromagnetic and surge environment.
推薦
推薦產品摘要
工程參考資料,適用於 AD7306JRZ — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | AD7306ARZ | AD7306AN | AD7306BRZ | AD7306CRZ | AD7306ERZ |
|---|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | 24-lead SOIC | 24-lead SOIC | 24-lead SOIC | 24-lead SOIC | 24-lead SOIC | 24-lead SOIC |
| Supply Voltage | 5 V | 5 V | 5 V | 5 V | 5 V | 5 V |
| Transmitter Count | 3 | 3 | 3 | 3 | 3 | 3 |
| Receiver Count | 3 | 3 | 3 | 3 | 3 | 3 |
| RS-232 Driver Count | 2 | 2 | 2 | 2 | 2 | 2 |
| RS-422 Driver Count | 1 | 1 | 1 | 1 | 1 | 1 |
| Maximum Data Rate | 5 Mbit/s | 5 Mbit/s | 5 Mbit/s | 5 Mbit/s | 5 Mbit/s | 5 Mbit/s |
| Special Feature | Configurable receiver path | Configurable receiver path | Configurable receiver path | Configurable receiver path | Configurable receiver path | Configurable receiver path |
主要差異化特點
- Combines multiple standards and channels in one interface IC (對比MAX3232ECPWR)
- Supports a larger combined serial-channel count (對比MAX232EIPWR)
- Offers 5 Mbit/s operation for dual-standard interfaces (對比MAX3232IDBR)
設計說明
Place the AD7306JRZ close to the external serial connectors and place any protection network between the connector and the transceiver pins. Keep driver-current returns short and do not route them through sensitive analog or logic ground paths. Because RS-232 uses bipolar single-ended signaling while RS-422 is differential, separate their return and routing geometry where practical.
Apply RS-422 termination according to the cable topology and receiver location rather than adding it automatically at every endpoint. The AD7306JRZ supports a 5 Mbit/s interface, but usable distance remains strongly dependent on cable characteristics, grounding, reflections, and protection components. Validate the complete channel with the intended cable and connector because connector capacitance and surge-protection capacitance can degrade edge performance.
Do not assume that every AD7306 ordering code is a production drop-in. Confirm the exact 24-SOIC footprint, pin names, temperature grade, and electrical limits in the manufacturer datasheet before substituting AD7306ARZ or another family member. Also configure or terminate unused driver and receiver channels according to the datasheet rather than leaving unconnected inputs to float.
Use a stable 5 V supply and place the recommended bypass capacitance directly between the supply and ground pins near the IC. Keep the 5 V return path continuous under RS-232 driver switching activity. Verify supply tolerance, startup behavior, and ground-reference requirements against the manufacturer recommendations for the selected ordering code.
合規資訊
No definitive product-specific environmental or material-compliance declarations were identified in the manufacturer product information used for this page. Obtain current compliance documentation from Analog Devices before procurement.