AD7714YRU - 24-Bit 5-Input Sigma-Delta ADC | Analog Devices
MPN: AD7714YRU ✓ 啟用中AD7714YRU 概覽
A sigma-delta ADC is a voltage regulator for the digital world: it oversamples an analog input and uses digital filtering plus noise shaping to produce a high-resolution conversion result. Within the ADC hierarchy, the AD7714 is a signal-conditioning ADC and a sigma-delta converter. Its programmable gain, differential inputs, external reference, and serial interface allow it to interface directly with low-level bridge, strain-gauge, pressure, temperature, and current-measurement sensors while reducing the need for separate analog conditioning hardware.
Key characteristics include up to 24-bit resolution, five selectable analog input channels, external-reference operation, and a 1 ksps maximum conversion rate identified for the AD7714 family. The device operates from either 3 V or 5 V, making it suitable for both industrial control systems and low-voltage portable measurement equipment. Its 500 µA operating current supports designs in which analog power consumption must remain low.
The converter uses a sigma-delta conversion architecture with digital filtering and programmable gain to provide high resolution for slowly changing or low-frequency signals. Differential operation rejects common-mode noise when both sides of a transducer bridge are converted simultaneously. The serial output supports integration with microcontrollers, programmable logic, or industrial communication interfaces, while the analog section handles excitation, gain, and conversion within one package.
Typical uses include weighing systems, process-control instrumentation, strain and pressure measurement, industrial sensor acquisition, and laboratory measurement equipment. The YRU ordering code identifies the industrial-temperature, TSSOP-24, tube-packaged variant according to the product listing. Its small surface-mount footprint supports compact data-acquisition and control boards while maintaining a pin-compatible family ecosystem.
When laying out the circuit, treat the analog input, reference, and digital interface sections separately to minimize coupling from switching nodes and serial clock edges. Place input and reference filtering components close to their associated pins, follow the pin-description table in the manufacturer datasheet, and verify the programmed gain, filter bandwidth, and output-data rate against the required settling time. Differential input conditioning should also account for the input common-mode range of the selected operating mode.
This page organizes the verified AD7714YRU specifications, package information, sourcing details, and design considerations into a practical engineering reference. It also identifies the documented family alternatives and explains where an explicit pin-for-pin substitute is not established, helping designers make a defensible PCB-level decision without assuming that a similar converter is automatically interchangeable.
直接替換替代品,適用於 AD7714YRU — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
AD7714YRUZ
✅ 直接替換📋 參考替代品(不在目錄中)
AD7714YRU 最大額定值與電氣特性
| Device Type | 24-bit sigma-delta signal-conditioning ADC |
| 解析度 | 24 bit |
| Differential Analog Inputs | 3 |
| Pseudo-Differential Analog Inputs | 5 |
| 供應電壓 | 3 V or 5 V |
| Power Consumption | 500 µA |
| Conversion Architecture | Sigma-delta |
| Maximum Conversion Rate | 1 ksps |
| Reference Type | External |
| Input Type | Differential or pseudo-differential |
| Package Type | TSSOP-24 |
| 腳位數 | 24 pins |
| Terminal Form | Gull wing |
| 安裝方式 | Surface mount |
| Temperature Grade | Industrial |
| Package Shape | Rectangular |
| RoHS 狀態 | Compliant |
| REACH Status | Compliant |
| Analog Front End | Integrated signal conditioning and conversion |
AD7714YRU rectangular 腳位配置指南
AD7714YRU(rectangular 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: AD7714YRU.
請參閱 資料表 以查看完整腳位配置。
典型應用
AD7714YRU 適用於 6 應用s: Strain-Gauge and Load-Cell Measurement, Industrial Pressure Transducer Interface, Precision Temperature Measurement, Portable Environmental and Sensor Acquisition, Multichannel Process-Control Instrumentation, Precision Current and Resistance Measurement.
Strain-Gauge and Load-Cell Measurement
The AD7714YRU fits resistive bridge load cells because its 24-bit resolution and three differential analog inputs can measure small millivolt-level bridge imbalances while rejecting common-mode voltage. The integrated sigma-delta signal-conditioning front end reduces the need for a separate instrumentation amplifier and low-noise ADC. In a typical bridge circuit, excitation passes through the bridge, the differential output goes to the analog inputs, and the converter produces a filtered serial result. The main engineering consideration is common-mode range: bridge excitation and input protection must remain within the operating limits of the selected analog mode, while the digital filter rate must satisfy the required settling time.
推薦
Industrial Pressure Transducer Interface
The AD7714YRU is suitable for industrial pressure transducers that produce a differential millivolt output proportional to pressure. Its 24-bit conversion capability supports high-resolution pressure readings, while three differential inputs can accommodate multiple sensing elements or switching networks. Place protection, filtering, and excitation components close to the converter so switching from a multiplexed bridge network does not inject noise into the measurement path. Because this is a low-frequency signal-conditioning ADC rather than a wideband converter, it works best with pressure elements whose mechanical response and settling time are slow enough for the programmed digital filter.
推薦
Precision Temperature Measurement
The AD7714YRU can acquire low-level resistive temperature sensor signals where high resolution and low power are more important than high sampling speed. Its differential inputs help reject noise present equally on both sensor lines, and the integrated gain and sigma-delta conversion stage can simplify the analog chain around an RTD bridge. A practical implementation uses a precision excitation source, input protection, and reference components whose noise and drift remain below the target measurement resolution. The conversion-rate and filter settings should be selected from the temperature settling time, and self-heating in the sensor must be included in the system error budget.
推薦
Portable Environmental and Sensor Acquisition
The 500 µA operating consumption and 3 V supply capability make the AD7714YRU useful in compact battery-powered sensor acquisition equipment. It can combine analog conditioning and 24-bit conversion for slow-changing environmental variables without requiring a separate high-resolution converter. Power strategy remains important: the digital interface, reference source, excitation circuit, and protection network can dominate the complete measurement node's current draw. Use the lowest supply voltage compatible with the analog and digital interface requirements, disable unused channels where supported, and schedule conversions so the host processor and sensor interface can share the available energy budget.
推薦
Multichannel Process-Control Instrumentation
The AD7714YRU can serve process-control and test equipment that monitor several low-level analog quantities, such as strain, temperature, or differential bridge outputs. Its three differential inputs or five pseudo-differential configurations provide channel flexibility, and the serial interface allows a controller to retrieve filtered conversion words without a parallel bus. An analog multiplexer or external switching network can expand the channel count, but its charge injection and off-channel behavior must be checked against the small signal levels being measured. Keep the reference and analog grounds in a clean return path to the converter rather than sharing high-current return paths with motors or relays.
推薦
Precision Current and Resistance Measurement
The AD7714YRU is applicable to precision current or resistance measurement when the sensor produces a differential voltage and the required update rate is low. Its 24-bit sigma-delta architecture and low 500 µA power consumption support accurate measurement nodes in industrial meters, calibration equipment, and laboratory instruments. The external reference path sets the conversion accuracy, so reference stability, input resistance, and filtering must be designed together. Use a continuous excitation current only when the sensor and analog input network can tolerate it, and account for offset, gain drift, and lead or contact resistance in the final uncertainty budget.
推薦
推薦產品摘要
工程參考資料,適用於 AD7714YRU — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | AD7714YRUZ |
|---|---|---|
| Brand | Analog Devices | Analog Devices |
| Package | TSSOP-24 | TSSOP-24 |
| Resolution | 24 bit | 24 bit |
| Differential Inputs | 3 | 3 |
| Pseudo-Differential Inputs | 5 | 5 |
| Supply Voltage | 3 V or 5 V | 3 V or 5 V |
| Power Consumption | 500 µA | 500 µA |
| Conversion Rate | 1 ksps | 1 ksps |
| Reference Type | External | External |
| Lifecycle Status | Active | Obsolete |
主要差異化特點
- Active product status for new production (對比AD7714YRUZ)
- Integrated multichannel signal-conditioning ADC (對比AD7714YRUZ)
- Low-power single-supply operation (對比AD7714YRUZ)
設計說明
Separate the analog and digital return paths and place the reference, analog-input, and digital-interface connections according to the AD7714 datasheet layout guidance. Keep the analog-input traces short and avoid routing them beneath the serial clock or data nets. A solid analog ground plane beneath the converter is generally preferable to a fragmented ground arrangement, while high-current return paths for relays, motors, and actuators should remain outside the measurement area.
Treat the differential input as a matched pair: route the positive and negative signals with similar geometry, terminate both inputs consistently, and avoid asymmetrical stubs. If an analog multiplexer or protection network is used, verify its switching transients against the input bandwidth and the smallest signal being measured. This converter is intended for low-frequency measurements, so excessive filtering or long unprotected input traces can degrade the useful signal more than the nominal converter resolution suggests.
Decouple the 3 V or 5 V supply close to the device pins with the capacitance and placement specified in the manufacturer data sheet, and provide a clean reference source because the external reference directly affects conversion accuracy. Check noise, drift, and warm-up behavior of the reference against the target measurement resolution. The listed 500 µA figure describes the converter's identified operating condition and does not include reference, excitation, protection, or interface current.
Do not select the digital output rate independently of the required settling time. The program must allow the programmed sigma-delta filter to settle after each input or gain change; reading earlier can produce a value that appears numerically valid but is not fully settled. Also avoid substituting a 24-pin SOIC for the TSSOP-24 footprint, and confirm input common-mode voltage, external-reference voltage, and serial-interface logic levels before releasing the PCB.
合規資訊
RoHS and REACH compliance are identified for the AD7714YRU and AD7714YRUZ comparison. The exact lead-free, halogen-free, conflict-minerals, and AEC-Q100 declarations for the selected ordering code require manufacturer documentation.