Analog Devices

AD7714YRU - 24-Bit 5-Input Sigma-Delta ADC | Analog Devices

料号: AD7714YRU ✓ 量产中
3 V or 5 V Vdss TSSOP-24 Package
最小起订量: 1 |

AD7714YRU 概述

The Analog Devices AD7714YRU is a 24-bit sigma-delta analog-to-digital converter with three differential analog inputs, five pseudo-differential input channels, a 3 V or 5 V supply, and a low 500 µA power consumption, housed in a 24-lead TSSOP package. It is designed as a complete low-frequency signal-conditioning front end for transducer and sensor measurements.

A sigma-delta ADC is a voltage regulator for the digital world: it oversamples an analog input and uses digital filtering plus noise shaping to produce a high-resolution conversion result. Within the ADC hierarchy, the AD7714 is a signal-conditioning ADC and a sigma-delta converter. Its programmable gain, differential inputs, external reference, and serial interface allow it to interface directly with low-level bridge, strain-gauge, pressure, temperature, and current-measurement sensors while reducing the need for separate analog conditioning hardware.

Key characteristics include up to 24-bit resolution, five selectable analog input channels, external-reference operation, and a 1 ksps maximum conversion rate identified for the AD7714 family. The device operates from either 3 V or 5 V, making it suitable for both industrial control systems and low-voltage portable measurement equipment. Its 500 µA operating current supports designs in which analog power consumption must remain low.

The converter uses a sigma-delta conversion architecture with digital filtering and programmable gain to provide high resolution for slowly changing or low-frequency signals. Differential operation rejects common-mode noise when both sides of a transducer bridge are converted simultaneously. The serial output supports integration with microcontrollers, programmable logic, or industrial communication interfaces, while the analog section handles excitation, gain, and conversion within one package.

Typical uses include weighing systems, process-control instrumentation, strain and pressure measurement, industrial sensor acquisition, and laboratory measurement equipment. The YRU ordering code identifies the industrial-temperature, TSSOP-24, tube-packaged variant according to the product listing. Its small surface-mount footprint supports compact data-acquisition and control boards while maintaining a pin-compatible family ecosystem.

When laying out the circuit, treat the analog input, reference, and digital interface sections separately to minimize coupling from switching nodes and serial clock edges. Place input and reference filtering components close to their associated pins, follow the pin-description table in the manufacturer datasheet, and verify the programmed gain, filter bandwidth, and output-data rate against the required settling time. Differential input conditioning should also account for the input common-mode range of the selected operating mode.

This page organizes the verified AD7714YRU specifications, package information, sourcing details, and design considerations into a practical engineering reference. It also identifies the documented family alternatives and explains where an explicit pin-for-pin substitute is not established, helping designers make a defensible PCB-level decision without assuming that a similar converter is automatically interchangeable.

直接替换替代料: AD7714YRU ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

AD7714YRUZ

✅ 直接替换
📦 TSSOP-24
Same 24-pin TSSOP footprint and 24-bit conversion function, but the documented product status is obsolete while AD7714YRU is active

📋 参考替代料(不在目录中)

AD7714YRU 最大额定值与电气特性

Device Type 24-bit sigma-delta signal-conditioning ADC
分辨率 24 bit
Differential Analog Inputs 3
Pseudo-Differential Analog Inputs 5
电源电压 3 V or 5 V
Power Consumption 500 µA
Conversion Architecture Sigma-delta
Maximum Conversion Rate 1 ksps
Reference Type External
Input Type Differential or pseudo-differential
Package Type TSSOP-24
引脚数 24 pins
Terminal Form Gull wing
安装方式 Surface mount
Temperature Grade Industrial
Package Shape Rectangular
RoHS 状态 Compliant
REACH Status Compliant
Analog Front End Integrated signal conditioning and conversion

AD7714YRU rectangular 引脚配置指南

AD7714YRU(rectangular 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。

AD7714YRU 的 rectangular 封装引脚图

暂无详细引脚数据: AD7714YRU.

请参阅 数据手册 以查看完整引脚配置。

典型应用

AD7714YRU 适用于 6 应用s: Strain-Gauge and Load-Cell Measurement, Industrial Pressure Transducer Interface, Precision Temperature Measurement, Portable Environmental and Sensor Acquisition, Multichannel Process-Control Instrumentation, Precision Current and Resistance Measurement.

⚖️

Strain-Gauge and Load-Cell Measurement

The AD7714YRU fits resistive bridge load cells because its 24-bit resolution and three differential analog inputs can measure small millivolt-level bridge imbalances while rejecting common-mode voltage. The integrated sigma-delta signal-conditioning front end reduces the need for a separate instrumentation amplifier and low-noise ADC. In a typical bridge circuit, excitation passes through the bridge, the differential output goes to the analog inputs, and the converter produces a filtered serial result. The main engineering consideration is common-mode range: bridge excitation and input protection must remain within the operating limits of the selected analog mode, while the digital filter rate must satisfy the required settling time.

🏭

Industrial Pressure Transducer Interface

The AD7714YRU is suitable for industrial pressure transducers that produce a differential millivolt output proportional to pressure. Its 24-bit conversion capability supports high-resolution pressure readings, while three differential inputs can accommodate multiple sensing elements or switching networks. Place protection, filtering, and excitation components close to the converter so switching from a multiplexed bridge network does not inject noise into the measurement path. Because this is a low-frequency signal-conditioning ADC rather than a wideband converter, it works best with pressure elements whose mechanical response and settling time are slow enough for the programmed digital filter.

🌡️

Precision Temperature Measurement

The AD7714YRU can acquire low-level resistive temperature sensor signals where high resolution and low power are more important than high sampling speed. Its differential inputs help reject noise present equally on both sensor lines, and the integrated gain and sigma-delta conversion stage can simplify the analog chain around an RTD bridge. A practical implementation uses a precision excitation source, input protection, and reference components whose noise and drift remain below the target measurement resolution. The conversion-rate and filter settings should be selected from the temperature settling time, and self-heating in the sensor must be included in the system error budget.

🧩

Portable Environmental and Sensor Acquisition

The 500 µA operating consumption and 3 V supply capability make the AD7714YRU useful in compact battery-powered sensor acquisition equipment. It can combine analog conditioning and 24-bit conversion for slow-changing environmental variables without requiring a separate high-resolution converter. Power strategy remains important: the digital interface, reference source, excitation circuit, and protection network can dominate the complete measurement node's current draw. Use the lowest supply voltage compatible with the analog and digital interface requirements, disable unused channels where supported, and schedule conversions so the host processor and sensor interface can share the available energy budget.

🏭

Multichannel Process-Control Instrumentation

The AD7714YRU can serve process-control and test equipment that monitor several low-level analog quantities, such as strain, temperature, or differential bridge outputs. Its three differential inputs or five pseudo-differential configurations provide channel flexibility, and the serial interface allows a controller to retrieve filtered conversion words without a parallel bus. An analog multiplexer or external switching network can expand the channel count, but its charge injection and off-channel behavior must be checked against the small signal levels being measured. Keep the reference and analog grounds in a clean return path to the converter rather than sharing high-current return paths with motors or relays.

🔧

Precision Current and Resistance Measurement

The AD7714YRU is applicable to precision current or resistance measurement when the sensor produces a differential voltage and the required update rate is low. Its 24-bit sigma-delta architecture and low 500 µA power consumption support accurate measurement nodes in industrial meters, calibration equipment, and laboratory instruments. The external reference path sets the conversion accuracy, so reference stability, input resistance, and filtering must be designed together. Use a continuous excitation current only when the sensor and analog input network can tolerate it, and account for offset, gain drift, and lead or contact resistance in the final uncertainty budget.

What is the AD7714YRU?
The AD7714YRU is a 24-bit sigma-delta signal-conditioning ADC from Analog Devices, designed for low-level analog measurements. According to the AD7714 manufacturer product page, it accepts three differential analog inputs that can be configured as five pseudo-differential inputs, uses an external reference, operates from 3 V or 5 V, and consumes 500 µA in the identified operating configuration. The AD7714YRU is packaged in a 24-lead TSSOP.
What are the key specifications of AD7714YRU that engineers should know?
The principal AD7714YRU specifications are 24-bit resolution, up to five pseudo-differential channels, three differential inputs, 3 V or 5 V operation, 500 µA power consumption, and a 1 ksps maximum conversion rate. The manufacturer product information identifies the device as a CMOS signal-conditioning ADC with an external reference. Its industrial-temperature ordering option and 24-pin TSSOP package make it suitable for compact precision-measurement boards.
How many analog input channels does the AD7714YRU have?
The AD7714YRU provides three differential inputs that can alternatively be configured as five pseudo-differential channels. According to the AD7714 manufacturer product page, this channel arrangement allows the converter to serve systems with several sensors or excitation sources. The selected differential or pseudo-differential mode also determines the applicable analog input and common-mode constraints.
What is the difference between AD7714YRU and AD7714YRUZ?
The AD7714YRU and AD7714YRUZ use the same 24-lead TSSOP footprint and both provide 24-bit sigma-delta conversion with three differential or five pseudo-differential channels. The documented comparison identifies differences in product status, and the YRU is listed as an active family option while another ordering variant is marked obsolete. Verify temperature grade, packing, lifecycle status, and ordering codes against the manufacturer product-selection table before substitution.
Where can I download the AD7714YRU datasheet PDF?
The official AD7714 datasheet and product documentation are available through the Analog Devices AD7714 product page at analog.com. The manufacturer page provides the data sheet, product selection table, application information, and related design resources. For the specific AD7714YRU ordering code, use the part-selection table to confirm package, temperature grade, packing, and lifecycle information before releasing a production BOM.
Where can I find the AD7714YRU pinout and package information?
The AD7714YRU uses a 24-lead TSSOP package with gull-wing leads and surface-mount construction. Use the pin-description table and package drawing in the AD7714 manufacturer datasheet when assigning PCB nets, and use the package outline drawing for land patterns and solder-paste design. Do not infer the pin map from a 24-pin SOIC because mechanically and electrically compatible pin naming does not guarantee a valid TSSOP footprint.
What is the best drop-in replacement for AD7714YRU?
The closest documented drop-in option is the AD7714YRUZ because it retains the 24-pin TSSOP package, 24-bit conversion, and the same differential and pseudo-differential channel arrangement. However, the documented product-status difference must be checked before using it in a new design. For an existing AD7714YRU board, confirm lifecycle status, temperature grade, lead finish, packing, and every external resistor and capacitor value before approving a substitution.
Can AD7714YRUZ replace AD7714YRU in an existing design?
The AD7714YRUZ can be considered for an existing AD7714YRU design because the published comparison lists the same 24-lead TSSOP package and matching conversion functions. It is not an automatic cross-manufacturer replacement, however, because documented product-status and ordering differences apply. Review the manufacturer data sheet and your BOM requirements, then verify operation at the required temperature and supply voltages before substitution.
When should I choose AD7714YRU over another sigma-delta ADC?
Choose the AD7714YRU when a design needs a complete low-frequency signal-conditioning front end with 24-bit resolution, three differential inputs or five pseudo-differential channels, and low 500 µA consumption. It is particularly useful for bridge-based sensors where differential operation improves common-mode rejection. Select a different converter if the required conversion rate, input bandwidth, reference architecture, or digital interface falls outside the AD7714 feature set.
Is the AD7714YRU suitable for pressure, strain-gauge, and temperature sensing?
The AD7714YRU is suitable for low-level sensor interfaces such as strain gauges, pressure elements, and resistive temperature sensors when their bandwidth requirements are low. Its integrated signal-conditioning ADC, differential inputs, programmable gain, and 24-bit sigma-delta architecture support measurements taken directly from passive bridges. The excitation voltage, input common-mode limits, and settled output rate must still be checked against the transducer.
What can replace the AD7714YRU?
The AD7714YRUZ is the closest family-level replacement because it uses the same 24-lead TSSOP footprint and provides the same 24-bit sigma-delta conversion and channel arrangement. No verified cross-manufacturer pin-to-pin equivalent is established for this MPN. If the AD7714YRUZ is unavailable or obsolete for your program, evaluate the AD7714 family ordering options or request a sourcing review through the Request a Quote form on this page.
Where to buy AD7714YRU online?
Use the Request a Quote form on this page to request AD7714YRU availability, current pricing, and order routing from XAIPART. The form supports a quote-first purchasing workflow for prototypes, production quantities, and scheduled releases. Specify the required reel, tube, or other packing option, quantity, target date, and destination country so procurement can confirm the correct order configuration.
What is the price of the AD7714YRU?
Current AD7714YRU pricing is generated through the Request a Quote form on this page rather than reproduced as a static figure. Submit the required quantity, package packing, shipping destination, and requested delivery schedule to obtain a current quotation. This approach also lets procurement confirm stock allocation and any manufacturer lead-time constraints associated with the selected ordering code.
What is the lead time for AD7714YRU?
Lead time depends on current inventory, the selected package or packing option, and manufacturer allocation at the time of order. Request a confirmed lead time through the Request a Quote form on this page and state your required delivery date. For a production program, provide your forecast quantities and target build schedule so procurement can evaluate scheduling options.
Is the AD7714YRU in stock?
Stock availability for the AD7714YRU changes with order volume, packing configuration, and current factory allocation. Submit your quantity and required packing through the Request a Quote form on this page for a current availability response. The AD7714 manufacturer product page identifies the device as part of the production CMOS AD7714 range, which is useful context for planning but does not by itself confirm a specific order allocation.
Is AD7714YRU a RoHS-compliant ADC?
The AD7714YRU is identified as RoHS compliant and REACH compliant in the manufacturer-related comparison information for the AD7714YRU and AD7714YRUZ. RoHS compliance covers restricted substances in electronic equipment, while REACH addresses substances of very high concern. Request the current manufacturer material-compliance declaration for the exact ordering code and packing configuration when formal qualification documentation is required.

工程参考数据: AD7714YRU ——对比、设计指导和合规信息。

选型指南

Choose the AD7714YRU for a new design that needs an active, low-power, 24-bit sigma-delta signal-conditioning ADC with three differential inputs or five pseudo-differential channels in a TSSOP-24 package. It is a strong fit for slow-moving bridge sensors, pressure elements, strain gauges, and precision resistance or temperature measurement where differential rejection, low 500 µA consumption, and 3 V or 5 V operation matter. Consider the AD7714YRUZ only when an existing design must be maintained and its documented obsolete status does not conflict with sourcing or qualification requirements. No verified cross-manufacturer drop-in part is established for this MPN, so changing manufacturers requires a separate engineering review of the analog front end, pin function, digital interface, reference design, and filtering behavior rather than a footprint-only substitution.

与替代料对比

参数 本产品 AD7714YRUZ
Brand Analog Devices Analog Devices
Package TSSOP-24 TSSOP-24
Resolution 24 bit 24 bit
Differential Inputs 3 3
Pseudo-Differential Inputs 5 5
Supply Voltage 3 V or 5 V 3 V or 5 V
Power Consumption 500 µA 500 µA
Conversion Rate 1 ksps 1 ksps
Reference Type External External
Lifecycle Status Active Obsolete

关键差异点

  • Active product status for new production (对比 AD7714YRUZ)
  • Integrated multichannel signal-conditioning ADC (对比 AD7714YRUZ)
  • Low-power single-supply operation (对比 AD7714YRUZ)

设计说明

Separate the analog and digital return paths and place the reference, analog-input, and digital-interface connections according to the AD7714 datasheet layout guidance. Keep the analog-input traces short and avoid routing them beneath the serial clock or data nets. A solid analog ground plane beneath the converter is generally preferable to a fragmented ground arrangement, while high-current return paths for relays, motors, and actuators should remain outside the measurement area.

Treat the differential input as a matched pair: route the positive and negative signals with similar geometry, terminate both inputs consistently, and avoid asymmetrical stubs. If an analog multiplexer or protection network is used, verify its switching transients against the input bandwidth and the smallest signal being measured. This converter is intended for low-frequency measurements, so excessive filtering or long unprotected input traces can degrade the useful signal more than the nominal converter resolution suggests.

Decouple the 3 V or 5 V supply close to the device pins with the capacitance and placement specified in the manufacturer data sheet, and provide a clean reference source because the external reference directly affects conversion accuracy. Check noise, drift, and warm-up behavior of the reference against the target measurement resolution. The listed 500 µA figure describes the converter's identified operating condition and does not include reference, excitation, protection, or interface current.

Do not select the digital output rate independently of the required settling time. The program must allow the programmed sigma-delta filter to settle after each input or gain change; reading earlier can produce a value that appears numerically valid but is not fully settled. Also avoid substituting a 24-pin SOIC for the TSSOP-24 footprint, and confirm input common-mode voltage, external-reference voltage, and serial-interface logic levels before releasing the PCB.

合规信息

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

RoHS and REACH compliance are identified for the AD7714YRU and AD7714YRUZ comparison. The exact lead-free, halogen-free, conflict-minerals, and AEC-Q100 declarations for the selected ordering code require manufacturer documentation.

数据核验日期: 2026-11-26 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

AD7714YRU datasheet AD7714YRU datasheet pdf AD7714YRU pinout AD7714YRU specifications AD7714YRU TSSOP-24 AD7714YRU price AD7714YRU stock AD7714YRU equivalent AD7714YRU drop-in replacement AD7714YRU vs AD7714YRUZ Analog Devices AD7714YRU AD7714 24-bit ADC application circuit AD7714YRU load cell amplifier AD7714YRU pressure sensor interface

相关元器件 & 术语

Analog Devices AD7714YRU AD7714YRUZ sigma-delta ADC signal-conditioning ADC analog-to-digital converter precision data acquisition 24-bit resolution differential input pseudo-differential input external reference programmable gain digital filter noise shaping TSSOP-24 TSSOP package family surface-mount package RoHS REACH low-frequency measurement strain-gauge bridge pressure transducer resistive temperature sensor industrial sensor interface serial data interface
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情