ADM230LAN - 5V Dual RS-232 Interface | Analog Devices
MPN: ADM230LAN ✗ 停產ADM230LAN 概覽
An RS-232 interface IC is a line-driver and line-receiver device that converts logic-level signals into voltage levels suitable for RS-232 communications. The RS-232 interface sits between a host or controller and an external data link, performing electrical conversion while protecting the transmitting and receiving circuitry from voltage differences on the cable. The ADM230LAN belongs to the CMOS interface-IC hierarchy and supports EIA-232-E and V.28 communication requirements.
The principal features include operation from one 5 V supply, on-board DC-DC conversion, a 120 kB/s maximum data rate, 9 V output swing, small 1 F charge-pump capacitors, a low-power shutdown function, and receiver operation during shutdown. These characteristics make the device useful in systems that need full RS-232 levels without requiring the conventional plus-and-minus supply arrangement.
The integrated DC-DC converter allows the transmitter circuitry to develop the bipolar voltage swing required by RS-232 while the device itself operates from a single 5 V rail. This simplifies system power architecture, although charge-pump capacitor selection, startup behavior, and output slew rate still require attention in high-speed or long-cable applications. The CMOS implementation supports the 120 kB/s signaling rate identified for this device family.
Typical applications include point-of-sale terminals, serial instrumentation, industrial control equipment, data acquisition systems, and legacy peripheral interfaces. The ADM230LAN is particularly suitable when an embedded controller uses TTL or CMOS logic but the connected equipment requires an RS-232 port. It can also support bidirectional serial links when both sides of the interface are wired for communication rather than permanently configured as DTE or DCE.
When laying out the circuit, place the charge-pump capacitors and interface bypass capacitors close to their associated pins, and route the RS-232 driver and receiver traces away from sensitive clock, reset, and analog signals. Confirm signal polarity, grounding, and DTE-versus-DCE assignments before connecting equipment because a physically wired RS-232 link can fail even when both devices meet the same electrical specifications.
This page organizes the ADM230LAN specifications, sourcing information, compatible alternatives, and application guidance into a practical engineering reference. It also highlights the trade-offs involved when selecting an integrated single-supply transceiver for industrial, instrument, and embedded serial communication systems.
直接替換替代品,適用於 ADM230LAN — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: ADM230LAN (相同外形與佔位) — 差異在於 Package, Supply Voltage, Product Type.
ADM230LAN 規格
| Product Type | Dual RS-232 driver and receiver interface IC |
| 供應電壓 | 5 V |
| Supply Configuration | Single positive 5 V supply |
| Logic Technology | CMOS |
| Maximum Data Rate | 120 kB/s |
| RS-232 Output Swing | 9 V |
| DC-DC Converter | On-board |
| Charge-Pump Capacitor Value | 1 F |
| Power Shutdown | Low-power shutdown supported |
| Receiver Operation During Shutdown | Receivers remain active |
| Receiver Input Voltage | 30 V |
| RS-232 Standards | EIA-232-E and V.28 |
| 封裝 | PDIP-14 |
| 安裝類型 | Through-hole |
| 腳位數 | 14 pins |
ADM230LAN pdip-14 腳位配置指南
ADM230LAN(pdip-14 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: ADM230LAN.
請參閱 資料表 以查看完整腳位配置。
典型應用
ADM230LAN 適用於 6 應用s: Point-of-Sale Terminal Interfaces, Industrial Serial Instrumentation, Data Acquisition Systems, Embedded Controller Serial Bridges, Legacy Peripheral Connectivity, Security and Access-Control Equipment.
Point-of-Sale Terminal Interfaces
The ADM230LAN fits point-of-sale equipment that must connect a low-voltage controller to a legacy RS-232 peripheral. Its single 5 V supply eliminates the need for a separate positive and negative RS-232 rail, while the on-board DC-DC converter supports approximately 9 V of output swing. The 120 kB/s data rate is suitable for many receipt printers, scanners, and customer-display devices. Place the 1 F charge-pump capacitors and bypass capacitors close to the device, and confirm whether the peripheral expects DTE or DCE signal assignments before wiring the cable.
推薦
Industrial Serial Instrumentation
The ADM230LAN is appropriate for industrial instruments that expose an RS-232 configuration or maintenance port. The 5 V CMOS interface reduces the power-supply burden compared with a traditional bipolar RS-232 implementation, while the 120 kB/s rate supports configuration exchanges and moderate-rate telemetry. Its 30 V receiver input rating adds tolerance for externally applied interface signals, although it does not replace dedicated surge protection. Validate the operating temperature grade, isolation strategy, enclosure grounding, and applicable industrial immunity requirements before deployment.
推薦
Data Acquisition Systems
The ADM230LAN can provide a legacy serial bridge in data acquisition systems whose controller operates with CMOS logic but whose external instrument uses RS-232. The integrated DC-DC converter permits operation from one 5 V rail, and the 120 kB/s data rate is useful for command traffic and sampled data streams that do not require high-speed serial links. The 14-pin PDIP package is easy to prototype and rework. Keep the RS-232 traces separated from sensitive analog inputs and use the circuit reference layout to control charge-pump noise near the converter.
推薦
Embedded Controller Serial Bridges
The ADM230LAN is useful when an embedded controller needs to communicate with equipment that retains an RS-232 port. Because the device accepts a single 5 V supply and includes its own DC-DC converter, it can simplify interface isolation and power distribution around a 3.3 V or 5 V controller. The 120 kB/s limit should be checked against the protocol's baud rate and framing overhead. Disable unused channels where appropriate, use controlled signal levels, and verify that software accounts for the RS-232 voltage polarity used by the connected DTE or DCE equipment.
推薦
Legacy Peripheral Connectivity
The ADM230LAN supports cost-conscious designs that must retain compatibility with legacy RS-232 printers, scales, programmers, or service interfaces. A 5 V supply reduces the number of external rails, while the on-board converter preserves the bipolar signaling expected by RS-232 equipment. The 120 kB/s ceiling accommodates many command-oriented legacy protocols. Before installation, verify the connector gender, signal-ground arrangement, logic polarity, and whether the peripheral uses DTE or DCE timing. A software loopback test is recommended during production validation.
推薦
Security and Access-Control Equipment
The ADM230LAN can be used in access-control or security-system accessories that maintain an RS-232 service or configuration link. Its single 5 V operation is useful in compact equipment, and the receiver can remain active during shutdown when a low-power state must still monitor an incoming signal. The 30 V receiver input rating should not be interpreted as complete surge immunity, so cable protection may still be required for long or exposed installations. Confirm the equipment's grounding policy and test compatibility with the attached controller before field deployment.
推薦
推薦產品摘要
工程參考資料,適用於 ADM230LAN — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | ADM230LJN | ADM230LAQ |
|---|---|---|---|
| Manufacturer | Analog Devices | Analog Devices | Analog Devices |
| Package | PDIP-14 | PDIP-14 | PDIP-14 |
| Supply Voltage | 5 V | 5 V | 5 V |
| Maximum Data Rate | 120 kB/s | 120 kB/s | 120 kB/s |
主要差異化特點
- Single-supply RS-232 implementation (對比ADM230LJN)
- Established 120 kB/s communications class (對比ADM230LAQ)
- Receiver availability during low-power shutdown (對比ADM230LJN)
設計說明
Place the 1 F charge-pump capacitors and local supply bypass components close to their specified ADM230LAN pins, following the Analog Devices manufacturer datasheet layout. Keep these high-current paths compact and connect the device ground directly to the interface ground reference. Long capacitor or supply routes can increase converter noise and make output behavior less repeatable, particularly when the transceiver operates near its 120 kB/s limit.
Route RS-232 driver outputs and receiver inputs away from clock, reset, ADC reference, and other sensitive analog nodes. The integrated DC-DC converter can couple switching energy into surrounding circuitry even though the complete interface operates from one supply rail. Use a quiet ground strategy, avoid routing return current beneath the transceiver, and maintain the separation recommended by the datasheet reference layout.
Do not infer DTE or DCE behavior from the IC alone; signal names, logic polarity, connector gender, and wiring must agree at both ends of the cable. Verify the receiver threshold, shutdown state, and supply sequence in hardware. A loopback test with representative software and peripheral equipment can expose swapped signals, incorrect grounding, or protocol assumptions before the board is deployed.
合規資訊
Compliance declarations are not identified in the manufacturer material cited for this page. Confirm RoHS, REACH, lead-free, halogen-free, conflict-minerals, and AEC-Q100 status using the current manufacturer product documentation before qualification.