ADS7871IDB - 14-Bit 48kSPS DAS with MUX and PGA | Texas Instruments
MPN: ADS7871IDB ✓ 啟用中ADS7871IDB 概覽
A data acquisition system, or DAS, is an integrated analog-to-digital measurement component that acquires multiple sensor inputs, applies gain and conversion, and makes the resulting measurements available through a digital interface. The ADS7871 belongs to the ADC → data converter → data acquisition system → semiconductor hierarchy. Its integrated multiplexer allows one converter to service several sensors, while its programmable-gain amplifier adapts the input level to the ADC range before conversion.
The principal features include 14-bit resolution, a maximum conversion rate of 48 kSPS, four differential or eight single-ended input paths, and an integrated precision reference. According to the Texas Instruments product description, these functions are combined in a single low-power chip. The SSOP-28 package also supports a compact PCB footprint, while the serial interface provides a practical path to embedded processors and control systems.
Internally, the multiplexer selects the required analog input and routes it through the programmable-gain amplifier into the 14-bit successive-approximation ADC. This architecture supports repeatable multichannel measurements without requiring a separate external multiplexer or analog front-end amplifier. The internal reference reduces calibration complexity by eliminating the need for a separate precision reference in designs that can use the on-chip source.
Typical uses include industrial process monitoring, factory automation, portable measurement instruments, battery-powered data loggers, environmental monitoring, and laboratory test equipment. The device is especially useful when several analog sensors must share one converter and when system size, component count, and power consumption are more important than very high conversion throughput.
Designers should account for analog input range, common-mode limits, programmable-gain settings, serial-interface timing, and the acquisition time associated with successive-approximation conversion. Input filtering and grounding remain important for low-noise measurements, especially when sensor sources have high source impedance or when adjacent channels carry large voltage differences.
This product page consolidates the device architecture, package information, application guidance, verified drop-in alternatives, and practical design considerations. It also highlights where the ADS7870EA differs in resolution so engineers can distinguish a close functional match from a true pin-compatible replacement before committing a PCB design.
直接替換替代品,適用於 ADS7871IDB — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: ADS7871IDB (相同外形與佔位) — 差異在於 ADC Resolution, Multiplexer Configuration, Package.
ADS7871IDB 最大額定值與電氣特性
| ADC Resolution | 14 bit |
| Maximum Sampling Rate | 48 kSPS |
| Multiplexer Configuration | 4 differential channels or 8 single-ended channels |
| Converter Architecture | 14-bit successive-approximation ADC |
| Programmable-Gain Amplifier | Integrated programmable-gain amplifier |
| Internal Reference | Precision internal voltage reference |
| Serial Interface | MICROWIRE, QSPI and SPI serial interface |
| 封裝 | 28-pin SSOP (DB) |
| 腳位數 | 28 pins |
| 工作溫度範圍 | -40 °C to +85 °C |
| Screening Level | Industrial |
| 安裝類型 | Surface mount |
ADS7871IDB 28-pin ssop (db) 腳位配置指南
ADS7871IDB(28-pin ssop (db) 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: ADS7871IDB.
請參閱 資料表 以查看完整腳位配置。
典型應用
ADS7871IDB 適用於 6 應用s: Industrial Process Monitoring, Battery-Powered Data Loggers, Environmental Monitoring, Factory Automation Controls, Laboratory Measurement Instruments, Portable Diagnostic Equipment.
Industrial Process Monitoring
The ADS7871IDB fits industrial process monitoring because one 28-pin device can acquire up to eight single-ended or four differential sensor signals at 14-bit resolution and 48 kSPS. The programmable-gain amplifier is useful when pressure, level, or temperature transmitters operate over widely different voltage ranges. Place the selected inputs behind suitable protection and filtering, then use the internal reference when its accuracy meets the calibration requirement. Compared with a system built from separate multiplexers, amplifiers, and ADCs, this integration reduces board area and component count while preserving an industrial -40 °C to +85 °C temperature range.
推薦
Battery-Powered Data Loggers
The ADS7871IDB is suitable for portable data loggers that periodically sample several sensors and then transmit the results. Its integrated multiplexer, programmable-gain amplifier, ADC, and reference reduce the number of active components in a compact analog section. The 48 kSPS capability provides ample margin for common temperature, light, pressure, and electrochemical measurements. Because this is a successive-approximation converter, the system should allow the acquisition interval to include conversion time rather than assuming continuous 48 kSPS conversion. Power budget calculations should also include the reference, analog front end, and host interface rather than the ADC alone.
推薦
Environmental Monitoring
The ADS7871IDB can support multichannel environmental monitoring systems that combine outputs from temperature, humidity, pressure, light, and air-quality sensors. Eight single-ended inputs allow several analog sensors to share the converter, while differential operation supports suitably referenced transducers with common-mode rejection. Its 14-bit conversion resolution provides more than 16,384 quantization levels, which is useful when sensor output spans are relatively narrow. Engineers should still calculate the full signal-chain error budget and use input filtering where long sensor leads can introduce noise or unwanted transient energy.
推薦
Factory Automation Controls
The ADS7871IDB is appropriate for factory automation controllers that monitor analog feedback from pressure switches, position sensors, potentiometers, and process transmitters. Four differential channels are available for noise-sensitive transducer connections, and the integrated PGA can bring smaller signals into the converter's usable range. A serial MICROWIRE, QSPI, or SPI connection allows the device to share PCB space with a digital controller. Layout should keep analog traces short, place filtering near the input pins, and maintain a quiet ground path so switching controllers and digital logic do not degrade the acquired measurement.
推薦
Laboratory Measurement Instruments
The ADS7871IDB can serve as the acquisition front end in compact laboratory instruments measuring multiple low-level analog quantities. Its 48 kSPS rate is suitable for many general-purpose meter and bench-test functions, while the integrated multiplexer and PGA reduce the number of discrete analog components. Differential input operation improves common-mode rejection when the source is balanced and properly referenced. For precision instruments, assess reference accuracy, offset and gain error, input settling, noise, and calibration procedures before setting the measurement resolution. The interface timing should also be checked against the controller used for triggering and data capture.
推薦
Portable Diagnostic Equipment
The ADS7871IDB is useful in portable diagnostic equipment that acquires several sensor channels under size and power constraints. Its 28-pin SSOP package accommodates a compact analog board, and the integrated multiplexer, PGA, ADC, and reference minimize external component count. A 14-bit result can support moderate-resolution sensing without requiring a higher-rate or more complex converter. The main design consideration is acquisition timing: the host must issue channel-selection commands, allow the analog input to settle, and then read the conversion result. Input protection should be selected for the sensor voltage range rather than assuming every external source can connect directly.
推薦
推薦產品摘要
工程參考資料,適用於 ADS7871IDB — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | ADS7870EA |
|---|---|---|
| Brand | Texas Instruments | Texas Instruments |
| Package | 28-pin SSOP (DB) | SSOP-28 |
| ADC Resolution | 14 bit | 12 bit |
| Maximum Sampling Rate | 48 kSPS | 52 kSPS |
| Multiplexer Configuration | 4 differential or 8 single-ended channels | 4 differential or 8 single-ended channels |
| Converter Architecture | 14-bit successive-approximation ADC | 12-bit successive-approximation ADC |
| Programmable-Gain Amplifier | Integrated | Integrated |
| Internal Reference | Precision internal voltage reference | 2.5 V internal reference |
| Serial Interface | MICROWIRE, QSPI and SPI | SPI-compatible serial interface |
主要差異化特點
- Higher conversion resolution (對比ADS7870EA)
- Complete multichannel acquisition front end (對比ADS7870EA)
- Multiple supported serial interfaces (對比ADS7870EA)
設計說明
Route analog inputs directly from their connector or sensor interface to the corresponding ADS7871IDB pins, avoiding shared traces with digital clocks and switching nodes. Place input filtering and protection near the device or connector as appropriate, and provide a low-impedance ground return. Because the converter uses successive approximation, verify settling time after changing the multiplexed channel before initiating conversion.
Do not treat the 14-bit converter resolution as the complete measurement accuracy. Include offset error, gain error, reference accuracy, input noise, source impedance, and leakage in the error budget. Confirm that each sensor output remains within the selected PGA range and the absolute analog input limits. Differential inputs also require correct common-mode voltage and return connections.
Keep the serial interface traces short and driven with levels appropriate for the host device. Apply controlled clock timing and configure the interface mode required by the ADS7871IDB. If sensors have long leads, use shielding or differential routing and add input filtering close to the ADC. These measures reduce coupling from motors, relays, display drivers, and switching power converters.
合規資訊
The industrial operating-temperature range is stated, but specific RoHS, REACH, halogen-free, conflict-minerals, and automotive qualification statements were not established for the exact ADS7871IDB ordering code. AEC-Q100 is not applicable to this catalog configuration.