A programmable system-on-chip is a mixed-signal microcontroller architecture that integrates a CPU, programmable digital and analog resources, memory, and peripherals into one device. Within the semiconductor hierarchy, the CY8C3444LTI-112 belongs to the microcontroller class and the broader embedded-control and system-on-chip categories. Its 8051 processing core provides a familiar instruction set while the PSoC architecture supports application-specific peripheral configurations.
The device operates at up to 50 MHz and includes 16 KB, or 16K by 8 bits, of flash memory for firmware storage. Its 1.71 V to 5.5 V operating range supports low-voltage embedded systems, and its 48-QFN package provides a compact surface-mount option for space-constrained designs. The exposed-pad package designation supports improved thermal dissipation when the board layout provides suitable copper area.
The CY8C34xx family architecture is intended to consolidate control logic and configurable peripheral functions without requiring separate discrete components. Configuration of the available digital and analog resources is managed through the PSoC development environment. Because firmware and peripheral assignments are part of the design, engineers should confirm the required signal routing, clocking, and configuration details against the family documentation before finalizing PCB connections.
Typical uses include compact industrial controllers, sensor-conditioning equipment, consumer interfaces, building-control modules, and low-power embedded products with several mixed-signal functions. The 48-QFN footprint is particularly appropriate when board area is constrained, while the 16 KB flash allocation is suitable for firmware that does not require a larger code image.
A critical hardware consideration is exposed-pad layout. Connect the thermal pad to the appropriate ground plane as directed by the manufacturer package guidance, and preserve short return paths from the pad into the PCB. Keep sensitive inputs away from high-current switching paths and follow the recommended decoupling arrangement to limit supply disturbance.
This product record combines the exact manufacturer-family specifications, package and ordering information, current sourcing details, replacement analysis, and practical implementation guidance. It is intended to help engineers determine whether the CY8C3444LTI-112 fits the required voltage, memory, processing, package, and embedded-control constraints before committing a PCB layout.
直接替換替代品,適用於 CY8C3444LTI-112 — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: CY8C3444LTI-112 (相同外形與佔位) — 差異在於 Package, Maximum CPU Frequency, CPU Architecture, Product Type.
CY8C3444LTI-119
✅ 直接替換聯絡詢價
查看資料表 →CY8C3444LTI-110
✅ 直接替換聯絡詢價
查看資料表 →CY8C3444LTI-119T
✅ 直接替換📋 參考替代品(不在目錄中)
CY8C3444LTI-112 最大額定值與電氣特性
| Product Type | 8-bit PSoC 3 microcontroller |
| CPU Architecture | 8051 |
| Maximum CPU Frequency | 50 MHz |
| Embedded Flash Memory | 16 KB (16K x 8 bits) |
| Operating Voltage Range | 1.71 V to 5.5 V |
| 封裝 | 48-QFN (7 mm x 7 mm) |
| Package Type | 48-VFQFN with exposed pad |
| 安裝類型 | Surface mount |
| Family | PSoC 3 CY8C34xx |
| Programmable System-on-Chip | Yes |
| 腳位數 | 48 pins |
| Package Dimensions | 7 mm x 7 mm |
| Supplier Inventory Listing | 5,984 pieces |
| Lead Time | To be confirmed |
| Estimated Delivery Window | July 20 to July 25 |
CY8C3444LTI-112 7 mm x 7 mm 腳位配置指南
CY8C3444LTI-112(7 mm x 7 mm 封裝)的腳位配置。 此數位 IC 包含 GPIO、通訊介面(UART、SPI、I2C)與電源腳位。替代腳位功能與配置選項請參閱製造商資料表。對嵌入式系統設計與 PCB 佈局至關重要。
無詳細腳位定義資料: CY8C3444LTI-112.
請參閱 資料表 以查看完整腳位配置。
典型應用
CY8C3444LTI-112 適用於 6 應用s: Compact Industrial Control Modules, Sensor Conditioning and IoT Nodes, Consumer Interface Controllers, Building Control and Monitoring, Low-Power Measurement Instruments, Battery-Powered Embedded Products.
Compact Industrial Control Modules
The CY8C3444LTI-112 fits compact industrial controllers because its 50 MHz 8051 core provides dedicated embedded processing while the PSoC 3 architecture consolidates programmable control functions. The 16 KB flash capacity supports a focused firmware image, and the 1.71 V to 5.5 V operating range accommodates low-voltage sensor and actuator interfaces. In a motor, valve, or process-control module, the device can coordinate inputs, timers, communications, and output sequencing without requiring a larger discrete logic design. The 48-QFN package preserves board area, but the exposed pad requires deliberate PCB thermal-copper placement and short ground-return routing.
推薦
Sensor Conditioning and IoT Nodes
The CY8C3444LTI-112 is appropriate for sensor-conditioning and connected-node designs that need programmable mixed-signal functions close to a microcontroller core. Its 50 MHz 8051 processor can manage sampling, filtering, configuration, and a local communication protocol within a 16 KB flash budget. The 1.71 V minimum operating voltage supports systems that must retain operation across a reduced voltage range, while the 48-QFN footprint suits densely populated sensing assemblies. Designers should allocate exposed-pad copper, maintain short analog and digital return paths, and confirm each configured PSoC resource and pin assignment in the device documentation.
推薦
Consumer Interface Controllers
The CY8C3444LTI-112 can serve as the control element in compact consumer interfaces where a keypad, indicator, sensor, and local serial peripheral must be coordinated. Its 8051 architecture is straightforward for embedded firmware development, while the PSoC 3 family provides configurable resources that can reduce the need for separate logic ICs. A 50 MHz operating speed gives designers additional timing margin for input scanning, debouncing, state management, and communications. The 7 mm by 7 mm 48-QFN package helps reduce PCB area, although assembly planning must account for fine-pitch routing and the exposed thermal pad.
推薦
Building Control and Monitoring
The CY8C3444LTI-112 is suitable for building-control nodes that combine environmental inputs with local outputs, status indicators, and a communication interface. Its 1.71 V to 5.5 V operating range supports low-power rails found in distributed control equipment, and the 16 KB flash provides storage for a focused control application rather than a large user interface. The 48-QFN package allows placement beside the associated sensing circuitry without occupying a large connector area. In a monitor or room-control unit, designers should isolate switching-node wiring from sensitive measurement paths and use the exposed pad as part of a carefully designed thermal and ground structure.
推薦
Low-Power Measurement Instruments
The CY8C3444LTI-112 fits compact measurement instruments that require deterministic control, data acquisition, calibration, and local user interaction. The 50 MHz 8051 core supports signal acquisition timing and control-loop tasks, while the 16 KB flash can hold a focused application and configuration firmware. Its 48-QFN package helps reduce instrument size without eliminating thermal design responsibility because the package includes an exposed pad. For accurate results, separate analog input routing from digital activity, provide stable supply decoupling, and confirm the PSoC configuration and clocking scheme against the family datasheet before production release.
推薦
Battery-Powered Embedded Products
The CY8C3444LTI-112 can be used in battery-powered products where a compact processor, configurable peripherals, and a 1.71 V minimum operating voltage are useful. The 50 MHz 8051 core provides performance headroom for control tasks, and the 16 KB flash limits firmware footprint in space-constrained products. Its 48-QFN package supports dense portable assemblies, while the exposed pad provides an effective heat-spreading path when the PCB provides adequate copper. Designers should evaluate average and peak current consumption in the configured design, minimize unused peripheral activity, and validate battery behavior across the intended voltage and temperature conditions.
推薦
推薦產品摘要
工程參考資料,適用於 CY8C3444LTI-112 — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | CY8C3444LTI-119 | CY8C3444LTI-110 | CY8C3444LTI-119T |
|---|---|---|---|---|
| Brand | Infineon Technologies | Infineon Technologies | Infineon Technologies | Infineon Technologies |
| Package | 48-QFN (7x7) | 48-QFN (7x7) | 48-QFN (7x7) | 48-QFN (7x7) |
| Product Family | PSoC 3 CY8C34xx | PSoC 3 CY8C34xx | PSoC 3 CY8C34xx | PSoC 3 CY8C34xx |
| Ordering Code | CY8C3444LTI-112 | CY8C3444LTI-119 | CY8C3444LTI-110 | CY8C3444LTI-119T |
主要差異化特點
- Exact 112 ordering configuration (對比CY8C3444LTI-119)
- Low-voltage operating range (對比CY8C3444LTI-119T)
- Compact exposed-pad package (對比CY8C3444LTI-110)
設計說明
Treat the exposed pad as an electrical and thermal feature rather than an optional area. Connect it to the recommended ground plane and provide uninterrupted copper beneath the package where the PCB footprint allows. Because this QFN has no large top-side leads, the exposed pad is the primary heat-transfer path. Check junction-temperature limits using the actual maximum ambient temperature and estimated operating dissipation; the pad alone does not guarantee safe operation if copper area or airflow is inadequate.
Place input and output decoupling capacitors close to their corresponding device pins and keep their return connections within the capacitor footprint. Route high-current or switching signals away from sensitive control and measurement nets. For the 48-QFN footprint, verify land pattern, solder-mask aperture, paste stencil, and exposed-pad assembly rules against the manufacturer package drawing before releasing PCB artwork.
Do not assume that every CY8C3444 suffix represents an interchangeable production choice. The 110, 112, 119, and 119T ordering codes appeared in family comparison and product records, but the available information does not establish that temperature grade, qualification, tape-and-reel status, or lifecycle conditions are identical. Compare the complete ordering-information table and the exact manufacturer datasheet before substituting one code for another.
Design the supply for the complete operating range of 1.71 V to 5.5 V, including startup, transient response, and peripheral configuration states. Verify that each external power rail falls inside the selected device's allowed limits and that the regulator can support the calculated peak current. Low input voltage does not automatically guarantee low total power if a PSoC resource or external subsystem remains active.
合規資訊
The manufacturer listings identify the device and package but do not state RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status. These fields therefore remain unknown.