DS90C363MTD/NOPB - 3.3V 18-Bit LVDS Transmitter | Texas Instruments
MPN: DS90C363MTD/NOPB ✗ 停產DS90C363MTD/NOPB 概覽
An LVDS transmitter is a low-voltage differential-signaling interface IC that converts parallel digital data into balanced differential outputs. In the signal hierarchy, an LVDS transmitter belongs to the broader category of display-interface ICs, interface ICs, and semiconductors. Balanced differential signaling reduces sensitivity to common-mode noise and allows reliable data transmission over longer cable or PCB traces than conventional single-ended digital signaling when implemented with suitable termination and routing practices.
The DS90C363 supports 18-bit parallel data and programmable transmitter characteristics. Its 612.5 Mbps maximum data rate corresponds to the stated 65 MHz operating frequency, while the 3.3 V supply operation suits modern low-voltage display systems. The 250 ps output rise time provides a useful measure of edge speed, and the specified 55 mA output current establishes the differential output-current capability used in link-budget calculations.
Technically, the device translates parallel pixel data into a low-voltage differential pair and provides the transmitter half of an FPD-Link connection. The 48-pin TSSOP package exposes the parallel data inputs, control signals, power connections, and differential outputs. Its -40°C to +85°C industrial temperature range supports industrial equipment, instrumentation, automotive-adjacent industrial systems, and professional display equipment where commercial-temperature parts would provide insufficient margin.
Typical applications include small-format LCD controller panels, industrial HMIs, test and measurement equipment, medical display modules, automotive navigation displays, and point-of-sale terminals. The transmitter can be paired with a compatible 18-bit LVDS receiver, such as the DS90CF364 family, to form a complete display-link path between graphics electronics and a remote panel.
PCB design should use controlled-impedance differential routing, symmetrical pair geometry, and the receiver-side termination specified by the link design. Keep the 18-bit source bus timing consistent, place decoupling close to the supply pins, and verify connector or cable compatibility before substituting a receiver with different electrical characteristics.
This product page combines the manufacturer device identity, package and ordering information, verified interface specifications, comparison information, and practical PCB guidance to support transmitter selection and replacement planning.
直接替換替代品,適用於 DS90C363MTD/NOPB — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: DS90C363MTD/NOPB (相同外形與佔位) — 差異在於 Operating Temperature Range, Package, Product Type.
DS90C363BMT/NOPB
✅ 直接替換聯絡詢價
查看資料表 →DS90C363MTD/NOPB 規格
| Product Type | Programmable LVDS flat-panel-display transmitter |
| Data Width | 18 bit |
| 供應電壓 | 3.3 V |
| 最大時脈頻率 | 65 MHz |
| Maximum Data Rate | 612.5 Mbps |
| Output Rise Time | 250 ps |
| Output Current | 55 mA |
| 工作溫度範圍 | -40°C to +85°C |
| Output Differential Voltage | 0.45 V |
| 封裝 | 48-pin TSSOP |
| 安裝類型 | Surface mount |
| 腳位數 | 48 pins |
| Signal Standard | FPD-Link and LVDS |
| 輸出類型 | Differential |
| Programmability | Programmable |
| RoHS 狀態 | unknown |
| REACH Status | unknown |
| AEC-Q100 Qualification | unknown |
DS90C363MTD/NOPB 48-pin tssop 腳位配置指南
DS90C363MTD/NOPB(48-pin tssop 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: DS90C363MTD/NOPB.
請參閱 資料表 以查看完整腳位配置。
典型應用
DS90C363MTD/NOPB 適用於 6 應用s: Industrial Human-Machine Interface Displays, Medical Display Modules, Automotive Navigation Displays, Test and Measurement Equipment, Point-of-Sale Terminals, Professional Video Monitor Interfaces.
Industrial Human-Machine Interface Displays
The DS90C363MTD/NOPB fits industrial HMI controllers that send 18-bit display data over an FPD-Link connection. Its 65 MHz maximum clock and 612.5 Mbps data rate provide the stated throughput for high-speed pixel transport, while the -40°C to +85°C range supports equipment exposed to temperature variation outside a 0°C to 70°C office environment. In implementation, the parallel source bus is converted into a differential LVDS output and paired with a compatible receiver. Control PCB routing must preserve pair symmetry and account for connector or cable losses.
推薦
Medical Display Modules
The DS90C363MTD/NOPB is appropriate for medical display modules when the controller and panel use an 18-bit differential display interface. The device transmits at up to 612.5 Mbps with a 250 ps differential output rise time, supporting compact point-to-point links between processing electronics and a remote display. Its industrial temperature rating also allows operation down to -40°C and up to +85°C. System qualification must separately verify medical standards, isolation architecture, display timing, and receiver compatibility; the transmitter qualification alone does not establish compliance for the finished product.
推薦
Automotive Navigation Displays
The DS90C363MTD/NOPB can serve as the transmitter in an automotive navigation or instrument display interface that uses compatible 18-bit FPD-Link signaling. A 3.3 V supply, 65 MHz maximum clock, and 612.5 Mbps data rate align with low-voltage digital display architectures, while the -40°C to +85°C range provides useful environmental margin for vehicle electronics. Designers should still perform vehicle-specific qualification and verify EMI behavior across the complete cable, connector, and receiver arrangement before production release.
推薦
Test and Measurement Equipment
The DS90C363MTD/NOPB is suitable for test and measurement instruments that need to distribute an 18-bit digital display stream over a compact differential interface. Its 612.5 Mbps maximum data rate supports high-resolution panel timing, and the 55 mA output current provides the documented differential drive capability for link budgeting. The transmitter should be placed close to the source device, while the receiver appears near the display connector. Controlled-impedance routing, appropriate termination, and validation of cable loss help preserve signal integrity over the complete instrument enclosure.
推薦
Point-of-Sale Terminals
The DS90C363MTD/NOPB can connect a graphics controller to a compact LCD in a point-of-sale terminal when both devices use a compatible 18-bit FPD-Link interface. The 3.3 V operation reduces supply requirements, and the 65 MHz clock supports the device's stated display-transfer capability. Differential outputs also reduce sensitivity to common-mode interference found in retail equipment with multiple switching and display loads. The designer should confirm panel timing, receiver compatibility, connector pinout, and cable length because these system-level details determine whether the full 612.5 Mbps capability remains usable.
推薦
Professional Video Monitor Interfaces
The DS90C363MTD/NOPB is applicable to professional monitors and compact broadcast equipment that use an 18-bit LVDS display architecture. Its maximum 612.5 Mbps data rate provides a direct match for the stated 65 MHz operating mode, while the 250 ps rise time defines the output edge rate engineers should consider during signal-integrity analysis. In a working link, the transmitter converts parallel pixel data near the graphics processor and the receiver reconstructs the data at the display. Short, impedance-controlled differential routes and verified connector behavior are essential in multi-panel or densely routed systems.
推薦
推薦產品摘要
工程參考資料,適用於 DS90C363MTD/NOPB — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | DS90C363BMT/NOPB |
|---|---|---|
| Brand | Texas Instruments | Texas Instruments |
| Package | 48-pin TSSOP | 48-pin TSSOP |
| Product Type | 18-bit LVDS FPD-Link transmitter | 18-bit LVDS FPD-Link transmitter |
| Supply Voltage | 3.3 V | 3.3 V |
| Maximum Clock Frequency | 65 MHz | 65 MHz |
| Maximum Data Rate | 612.5 Mbps | 612.5 Mbps |
| Output Current | 55 mA | 55 mA |
| Operating Temperature Range | -40°C to +85°C | -10°C to +70°C |
主要差異化特點
- Wider industrial temperature coverage (對比DS90C363BMT/NOPB)
- Native 65 MHz display-link operation (對比DS90C363BMT/NOPB)
- Documented differential output behavior (對比DS90C363BMT/NOPB)
設計說明
Route the LVDS output as a controlled-impedance differential pair with continuous reference planes, symmetric geometry, and minimized stubs. Avoid discontinuities such as right-angle traces and unnecessary test pads. The receiver termination and connector launch geometry must be evaluated together because the 250 ps output rise time contains high-frequency content that can expose impedance discontinuities even when the parallel data bus appears correctly timed.
Place the transmitter and its local supply-decoupling network close to the graphics controller or source device. Follow the manufacturer's datasheet layout for supply and ground connections, and keep the 18-bit source traces short enough to preserve edge-to-edge timing at 65 MHz. Differential trace length matching should be based on the actual receiver and cable arrangement rather than a generic tolerance alone.
Do not approve the DS90C363BMT/NOPB as a substitute when the finished system can operate below -10°C or above 70°C. Its stated temperature range is narrower than the DS90C363MTD/NOPB range of -40°C to +85°C. Also verify receiver compatibility, link configuration, cable length, connector assignment, and termination before treating a shared package as proof of complete interchangeability.
Keep the LVDS pair away from clocks, switching-node returns, and other high-di/dt conductors. Maintain a continuous ground reference beneath the pair, use common-mode filtering only where it is supported by the complete link design, and verify radiated and conducted emissions at the finished-product level. A nominal 612.5 Mbps data rate does not by itself guarantee EMC compliance after enclosure, cable, and connector effects are included.
合規資訊
The /NOPB suffix identifies a no-lead-finish ordering option, but no explicit RoHS, REACH, AEC-Q100, halogen-free, or conflict-minerals declaration was established for this exact MPN. Automotive suitability depends on the complete product qualification and is not established solely by the operating-temperature range.