Texas Instruments

ICL7135CNG4 - 4.5-Digit Dual-Slope ADC | Texas Instruments

MPN: ICL7135CNG4 ✓ 啟用中
1 pA Id 28-pin PDIP, 15.24 mm body width Package
MOQ: 1 |

ICL7135CNG4 概覽

Texas Instruments ICL7135CNG4 is a 4.5-digit, multiplexed BCD dual-slope analog-to-digital converter with 3 samples per second conversion speed and integrated seven-segment display drivers, housed in a 28-pin PDIP package. The converter provides true differential input, 1 pA typical input current, and a 2.0000 V full-scale reference capability for precision measurement and display systems.

A dual-slope ADC is a signal-conditioning and conversion category that integrates an input signal over a fixed interval and compares the result with a reference time. This integrating approach is well suited to meters and panel displays because it rejects periodic interference, provides good noise performance, and avoids the complexity of a high-speed flash converter. Within the broader hierarchy, the ICL7135CNG4 is an ADC, then a data converter, then an integrated circuit used in electronic measurement systems.

Key features include one analog input channel, 4.5-digit BCD output, multiplexed seven-segment display drive, and support for LED or LCD display types. The device supports a 4.5-digit display format with accuracy specified as ±1 count in 20,000 according to the manufacturer datasheet. These characteristics suit digital panel meters, laboratory instruments, process monitoring, and equipment requiring a stable numeric readout rather than a high-speed waveform acquisition.

The dual-slope conversion architecture integrates the input and reference over controlled periods. A 3 samples-per-second maximum conversion rate favors readable displays and ordinary low-frequency measurements rather than audio, communications, or motor-control sampling. The 2.0000 V full-scale reference capability provides a defined measurement range when paired with suitable input scaling, while the differential input arrangement helps reject common-mode voltage when both input paths are driven appropriately.

Typical applications include laboratory digital voltmeters, panel-based process indicators, weighing and laboratory instrumentation, and embedded numeric measurement systems. In each case, the converter's BCD output and display drivers can reduce the host-controller workload. The 28-pin PDIP format also remains convenient for through-hole industrial control boards, provided the board layout includes adequate clearance around the device.

When laying out the circuit, follow the manufacturer datasheet for reference, integration, input, and display-driver connections. Place sensitive input and reference paths away from switching nodes and display-driver return currents. Confirm that the selected display type, drive configuration, timing components, and reference voltage match the intended meter architecture before releasing the PCB.

This page organizes the ICL7135CNG4 specifications, package information, comparison options, and application guidance into an engineering-focused reference. It also identifies verified drop-in candidates and highlights the design trade-offs that matter when selecting a dual-slope display-oriented ADC.

直接替換替代品,適用於 ICL7135CNG4 — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。

此系列的變體

與下列產品可直接替換的同系列型號: ICL7135CNG4 (相同外形與佔位) — 差異在於 Package, Output Format.

Texas Instruments
Package: 28-pin DIP
Output Format: Multiplexed BCD output
比較對象 ICL7135CNG4 →
Maxim Integrated
Package: 28-pin plastic DIP
比較對象 ICL7135CNG4 →

ICL7135CPI+

✅ 直接替換
Maxim Integrated
📦 28-pin PDIP
4.5-digit dual-slope analog-to-digital converter · Multiplexed binary-coded decimal (BCD) · ±1 count in 20,000 · 2.0000 V · Differential, high impedance · 28-pin plastic DIP · 28 pins · 4 multiplexed digit-drive positions

聯絡詢價

查看資料表 →

ICL7135CPI+2

✅ 直接替換
📦 28-pin PDIP
Same 4.5-digit BCD dual-slope family and 28-pin PDIP format; ordering-suffix conditions must be verified

📋 參考替代品(不在目錄中)

ICL7135CNG4 最大額定值與電氣特性

ADC Type Dual-slope ADC
解析度 4.5 digits
Channel Count 1 channel
Maximum Conversion Rate 3 samples/s
Output Format Multiplexed binary-coded decimal (BCD)
Display Type 7-segment LED or LCD
Input Configuration True differential input
Typical Input Current 1 pA
Full-Scale Reference 2.0000 V
Accuracy ±1 count in 20,000
Zero Reading for 0 V Input Supported
Precision Null Detection True polarity
Temperature Grade Commercial
封裝 28-pin PDIP, 15.24 mm body width
安裝類型 Through-hole
Packaging Tube

ICL7135CNG4 28-pin pdip, 15.24 mm body width 腳位配置指南

ICL7135CNG4(28-pin pdip, 15.24 mm body width 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。

ICL7135CNG4 的 28-pin pdip, 15.24 mm body width 封裝腳位圖

無詳細腳位定義資料: ICL7135CNG4.

請參閱 資料表 以查看完整腳位配置。

典型應用

ICL7135CNG4 適用於 6 應用s: Digital Panel Meter, Laboratory Digital Voltmeter, Process Monitoring Indicator, Precision Temperature Display, Weighing Scale Readout, Laboratory Data Logger Front End.

📺

Digital Panel Meter

The ICL7135CNG4 fits digital panel meters because it combines a 4.5-digit dual-slope ADC, multiplexed BCD output, and seven-segment display drivers in one 28-pin PDIP device. At up to 3 samples/s, it produces a readable numerical indication rather than a high-speed data stream. The converter can be placed behind a scaled input network for DC voltage or current measurement, while its true differential input helps reduce common-mode sensitivity. In a meter designed around the manufacturer reference circuit, the display driver outputs directly support the digit and segment multiplexing arrangement. The design trade-off is that the tube-packaged through-hole package requires board space and manual or through-hole assembly, making it more appropriate for established instrument formats than compact wearable products.

🔧

Laboratory Digital Voltmeter

The ICL7135CNG4 is suitable for a laboratory digital voltmeter when the priority is stable, readable voltage measurement. Its 4.5-digit format supports resolution beyond a conventional 3.5-digit display, and the ±1 count in 20,000 accuracy specification provides a defined conversion-performance basis. The 2.0000 V full-scale reference can support a scaled front end, while true differential input is useful when both measurement inputs are referenced carefully. A 3 samples/s update rate is appropriate for an instrument that presents continuously refreshed readings to an operator. Engineers should use the manufacturer’s reference and integration guidance, keep sensitive analog traces compact, and avoid routing display return current through the input and reference ground paths.

🏭

Process Monitoring Indicator

The ICL7135CNG4 can serve as the measurement core of an industrial process-monitoring indicator when the process variable changes slowly and must be presented numerically. The 4.5-digit BCD result and integrated seven-segment drivers simplify a display-oriented design, while the 3 samples/s conversion rate provides continuous updates without excessive conversion activity. A transmitter or resistive sensor can be conditioned into the converter’s differential input range, and the 2.0000 V full-scale reference establishes the measurement endpoint. For panel equipment, the commercial-grade 28-pin PDIP package is easy to inspect and service. The main implementation concern is electrical isolation: the timing, reference, and analog input sections should follow the datasheet layout so switching displays or nearby industrial circuits do not degrade the displayed measurement.

🧩

Precision Temperature Display

A temperature display benefits from the ICL7135CNG4’s 4.5-digit resolution, true differential input, and integrated display drive. The converter can digitize the output of a suitable linear temperature sensor or bridge stage, with the external analog network scaled so the expected temperature range occupies a useful portion of the 2.0000 V full-scale reference. A 3 samples/s update rate is ample for a readable panel indication and prevents excessive display flicker. Differential measurement is valuable because it allows the converter to compare two related sensor signals and reduce common-mode error when the sensor and electronics share a ground reference. Careful input protection, filtering, and reference decoupling are essential near thermocouple or sensor wiring, and the manufacturer pin and application diagrams should govern the final layout.

⚖️

Weighing Scale Readout

The ICL7135CNG4 is appropriate for a weighing-scale readout when the load-cell signal is converted through a low-noise analog front end and displayed as a four-and-a-half-digit value. Its dual-slope architecture is well matched to the relatively slow mechanical response of a scale, and the 3 samples/s conversion rate is sufficient for an operator-facing display. The BCD output and seven-segment drive functions reduce the number of external display-interface components. A 1 pA typical input current is valuable in high-impedance front ends, although the complete system must also satisfy offset, reference, and leakage requirements. Mechanical vibration near the converter can disturb a high-resolution measurement, so the PCB should be mechanically isolated as appropriate and sensitive analog routing should avoid display-driver currents.

🖥️

Laboratory Data Logger Front End

The ICL7135CNG4 can form the display-oriented measurement front end of a laboratory data logger for slow-moving voltage inputs. Its 4.5-digit BCD output provides a straightforward interface to a display controller or host system, and the 3 samples/s rate is suitable for supervisory readings rather than high-rate sampling. The true differential input can simplify comparison and ratiometric measurements when both channels are carefully buffered. Because the integrated display drivers are intended for segmented outputs, a logger requiring binary data, higher sample rates, or low-power operation may be better served by a different ADC family. In this application, select suitable protection and filtering components, maintain a clean reference network, and separate display return currents from precision analog ground paths to preserve measurement stability.

推薦產品摘要

CD4536BM96 Timing companion for precision meter front ends 用於: Digital Panel Meter, Laboratory Digital Voltmeter, Process Monitoring Indicator, Precision Temperature Display, Weighing Scale Readout CD4053BME4 Analog multiplexing companion for selectable measurement inputs 用於: Digital Panel Meter, Process Monitoring Indicator, Laboratory Data Logger Front End AD9544BCPZ Analog Devices 用於: Laboratory Digital Voltmeter, Precision Temperature Display, Weighing Scale Readout, Laboratory Data Logger Front End
What is the ICL7135CNG4?
The ICL7135CNG4 is a 4.5-digit, one-channel dual-slope ADC with multiplexed BCD output and integrated seven-segment display drivers. According to the Texas Instruments datasheet, it performs up to 3 conversions per second and is packaged in a 28-pin PDIP. Its true differential input and 1 pA typical input current make it appropriate for precision panel meters, laboratory instruments, and low-frequency measurement systems.
What are the key specifications of ICL7135CNG4 that engineers should know?
The ICL7135CNG4 provides 4.5-digit resolution, one analog input channel, a maximum conversion rate of 3 samples/s, and multiplexed BCD output. It includes seven-segment display drivers for LED or LCD displays, true differential input, 1 pA typical input current, and a 2.0000 V full-scale reference. The commercial-grade device uses a through-hole 28-pin PDIP package supplied in a tube, making its electrical and mechanical characteristics clear for meter-board designs.
Where can I download the ICL7135CNG4 datasheet PDF?
The ICL7135CNG4 datasheet can be downloaded from the manufacturer-linked PDF page listed on this page. The document is identified as the Texas Instruments data for a 4.5-digit precision analog-to-digital converter and includes the device description, electrical characteristics, pin assignments, and application information. Use that document as the controlling reference for reference voltage, timing components, input configuration, display connections, and operating limits.
Where can I find the ICL7135CNG4 pinout?
The ICL7135CNG4 pinout is documented in the Texas Instruments datasheet under the pin-configuration and connection diagrams. The device has 28 pins in a PDIP package, with functions associated with analog input, reference, power, timing, BCD output, and display drive. Use the package diagram and pin-description table when assigning PCB nets because individual BCD and digit-drive functions are multiplexed across the output pins.
Is ICL7135CNG4 suitable for a digital panel meter?
Yes, the ICL7135CNG4 is suitable for a digital panel meter because it combines a 4.5-digit dual-slope converter with multiplexed BCD output and seven-segment display drivers. Its 3 samples/s conversion rate prioritizes a stable readable indication over high-speed sampling, while true differential input can improve rejection of common-mode voltage. It fits meters for DC voltage, current, resistance, temperature, and process variables when the analog front end is scaled correctly.
How fast is the ICL7135CNG4 ADC?
The ICL7135CNG4 has a maximum conversion rate of 3 samples per second. This rate is appropriate for continuously refreshed numerical panel displays, laboratory meters, and slow process measurements. It is not intended for high-frequency waveform capture, audio processing, or communications. The dual-slope method favors measurement stability and interference rejection, while the displayed result can update at a rate that remains comfortable for an operator to read.
What does dual-slope ADC mean for the ICL7135CNG4?
Dual-slope conversion means the ICL7135CNG4 measures the input by integrating it over a defined period and comparing that integration with a reference interval. This ADC method is a data-conversion technique within the broader ADC and integrated-circuit categories. It is especially useful for numeric meters because it naturally rejects some periodic interference and pairs well with a reference circuit, timing network, and seven-segment display.
What is the difference between ICL7135CNG4 and ICL7135CPI+?
The ICL7135CNG4 and ICL7135CPI+ are both described as 4.5-digit BCD-output dual-slope ADCs in 28-pin PDIP packages, so they share the principal measurement function and pin count. The suffix and ordering information distinguish their specific qualification and ordering variants. Confirm every pin function, timing value, temperature limit, and marking requirement in the manufacturer documentation before treating either ordering code as a production replacement.
What is the difference between ICL7135CNG4 and ICL7135CPI+2?
The ICL7135CNG4 and ICL7135CPI+2 are both listed as 28-pin PDIP, 4.5-digit BCD-output converters from the same device family. Their family-level architecture is similar, but the ordering suffixes can represent different grade, package, or lead-free conditions. Verify the exact suffix definition and every electrical limit before substitution because a shared package and conversion format alone do not guarantee identical production qualification.
When should I choose ICL7135CNG4 over ICL7135CPI+?
Choose ICL7135CNG4 when the required production specification explicitly identifies that ordering code and its commercial-grade 28-pin PDIP implementation. Choose ICL7135CPI+ only after checking its exact suffix definition, temperature grade, and datasheet limits against the intended product requirements. Both parts are associated with the same 4.5-digit dual-slope family, so the deciding factors are the approved ordering configuration, qualification needs, and verified electrical equivalence.
Is ICL7135CNG4 the same as ICL7106CPLZ?
No, the ICL7135CNG4 should not be assumed to be interchangeable with the ICL7106CPLZ merely because both are precision display-oriented ADCs. The ICL7135CNG4 is identified as a 4.5-digit, one-channel dual-slope converter in a 28-pin PDIP, whereas the ICL7106 family requires its own pin and electrical comparison. Use the ICL7106CPLZ comparison and manufacturer documentation to determine whether a redesign or a qualified substitution is required.
What can replace ICL7135CNG4?
The closest identified drop-in candidates are the ICL7135CPI+ and ICL7135CPI+2 because they share the ICL7135 family architecture, 4.5-digit BCD output, 28-pin PDIP format, and commercial temperature class. Before replacing ICL7135CNG4, verify the exact pin functions, reference requirements, timing values, electrical limits, and ordering suffix against the approved device specification. No other substitute is presented as a verified drop-in candidate.
Where can I buy ICL7135CNG4 online?
Use the Request a Quote form on this page to request ICL7135CNG4 availability, current unit pricing, quantity breaks, and lead time. The form provides a direct purchasing channel without embedding a price that may change. For production planning, request the exact ICL7135CNG4 ordering code and confirm tube packaging, quantity multiples, delivery timing, and any lifecycle constraints in the quotation response.
How much does ICL7135CNG4 cost?
Current ICL7135CNG4 pricing depends on quantity, availability, and market conditions and is therefore not reproduced as a static figure on this page. Submit the Request a Quote form with your required quantity and tube-packaging preference to obtain a current quotation. The request should also cover scheduled delivery quantities so that sourcing can distinguish prototype requirements from production replenishment.
What is the lead time for ICL7135CNG4?
The current ICL7135CNG4 lead time depends on supplier inventory and the requested production quantity. Request it through the Request a Quote form on this page, specifying quantity, target date, and whether staged deliveries are acceptable. For a new instrument design, treat lead time as a schedule dependency and obtain written confirmation before committing the mechanical release, test plan, and production build date.

工程參考資料,適用於 ICL7135CNG4 — 比較、設計指引及合規資訊。

選型指南

Choose the ICL7135CNG4 when the product needs a dedicated 4.5-digit numerical display, a one-channel dual-slope measurement stage, and a commercial-grade 28-pin PDIP implementation. Its integrated seven-segment drivers and multiplexed BCD output simplify panel-meter electronics, while the 3 samples/s rate matches slow-moving process variables and laboratory instruments rather than waveform acquisition. ICL7135CPI+ is the closest identified alternative because it shares the same family architecture, package, and BCD output; select it only after confirming the ordering suffix, qualification, and exact electrical limits. ICL7135CPI+2 is likewise a package-matched family candidate with similar architecture. Neither alternative should replace the ICL7135CNG4 without a pin-by-pin and specification-level review. If the design needs higher sampling speed, compact surface-mount construction, binary output, or a lower-power architecture, select a different ADC class because these candidates retain the display-oriented dual-slope architecture.

與替代品比較

參數 本產品 ICL7135CPI+ ICL7135CPI+2
Brand Texas Instruments Texas Instruments Texas Instruments
Package 28-pin PDIP 28-pin PDIP 28-pin PDIP
Converter Architecture Dual-slope ADC Dual-slope ADC Dual-slope ADC
Resolution 4.5 digits 4.5 digits 4.5 digits
Output Format Multiplexed BCD Multiplexed BCD Multiplexed BCD
Full-Scale Reference 2.0000 V 2.0000 V 2.0000 V
Accuracy ±1 count in 20,000 ±1 count in 20,000 ±1 count in 20,000
Temperature Grade Commercial Commercial Commercial
Mounting Type Through-hole Through-hole Through-hole

主要差異化特點

  • Integrated measurement and display interface (對比ICL7135CPI+)
  • Differential measurement input (對比ICL7135CPI+2)
  • Readable display-oriented conversion rate (對比ICL7135CPI+)

設計說明

Route the analog input, reference, and integration paths away from the multiplexed BCD and seven-segment display outputs. Display-driver currents can couple into sensitive measurement nodes, particularly when the converter is resolving a small difference near full scale. Follow the manufacturer’s recommended application layout, keep analog and digital return currents separated as far as practical, and place input filtering and reference components close to their associated pins.

Design the supply rails and reference network to satisfy the ICL7135CNG4 absolute maximum ratings and operating conditions before calculating error budget. The 2.0000 V full-scale reference capability is a system reference point, not permission to exceed the device’s specified supply range. Use stable reference components, adequate decoupling, and defined startup behavior. Confirm the selected reference and supply tolerances against the required overall measurement accuracy rather than treating the converter accuracy as the complete system error.

Do not assume that a shared package makes every ICL7135 ordering suffix automatically interchangeable. The verified candidates share the 28-pin PDIP format and family-level conversion function, but the suffix can change ordering, grade, or qualification conditions. Before substitution, compare every pin name and function, the reference and integration networks, timing limits, temperature range, electrical characteristics, and package marking against the released design.

The 3 samples/s conversion rate is intentional for readable dual-slope measurements and should not be treated as a general-purpose sampling limit. If the design requires audio bandwidth, waveform capture, rapid process tracking, or sampled data storage, select an ADC with a substantially higher conversion rate and a suitable data interface. For a stable panel meter, the lower rate can instead reduce display activity and simplify the operator experience.

合規資訊

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
無鉛
Unknown
無鹵
Unknown
衝突礦產
Unknown

No explicit compliance declaration was identified for ICL7135CNG4. AEC-Q100 is not applicable because this is a commercial-grade precision ADC rather than an automotive-qualified device.

資料驗證日期: 2026-11-24 — 資料由 XAIPART 元件工程團隊驗證及整理

相關搜尋

ICL7135CNG4 ICL7135CNG4 datasheet ICL7135CNG4 pinout ICL7135CNG4 datasheet pdf ICL7135CNG4 equivalent ICL7135CNG4 replacement ICL7135CNG4 vs ICL7135CPI+ Texas Instruments ICL7135CNG4 ICL7135CNG4 28-pin PDIP ICL7135CNG4 digital panel meter ICL7135CNG4 price ICL7135CNG4 stock

相關元件與詞彙

Texas Instruments ICL7135CNG4 ICL7135CPI+ ICL7135CPI+2 ICL7106CPLZ dual-slope ADC analog-to-digital converter ADC data converter integrated circuit 4.5-digit BCD multiplexed BCD output seven-segment display driver LED display LCD display true differential input 2.0000 V full-scale reference PDIP-28 through-hole package tube packaging digital panel meter laboratory voltmeter process monitoring integrating ADC power supply rejection ratio
快速報價 RFQ
請填寫完整詳細資料 — 我們的業務團隊將於 24 小時內回覆
料號 製造商 封裝 QTY 目標價格 小計
✓
報價已提交!

我們將於 24 小時內回覆您的電子郵件

1
詢價已提交
2
已收到報價
3
已下單
4
付款
5
已出貨
6
已送達
檢視詢價單詳情