Texas Instruments

ICL7135CNG4 - 4.5-Digit Dual-Slope ADC | Texas Instruments

부품 번호: ICL7135CNG4 ✓ 활성
1 pA Id 28-pin PDIP, 15.24 mm body width Package
MOQ: 1 |

ICL7135CNG4 개요

Texas Instruments ICL7135CNG4 is a 4.5-digit, multiplexed BCD dual-slope analog-to-digital converter with 3 samples per second conversion speed and integrated seven-segment display drivers, housed in a 28-pin PDIP package. The converter provides true differential input, 1 pA typical input current, and a 2.0000 V full-scale reference capability for precision measurement and display systems.

A dual-slope ADC is a signal-conditioning and conversion category that integrates an input signal over a fixed interval and compares the result with a reference time. This integrating approach is well suited to meters and panel displays because it rejects periodic interference, provides good noise performance, and avoids the complexity of a high-speed flash converter. Within the broader hierarchy, the ICL7135CNG4 is an ADC, then a data converter, then an integrated circuit used in electronic measurement systems.

Key features include one analog input channel, 4.5-digit BCD output, multiplexed seven-segment display drive, and support for LED or LCD display types. The device supports a 4.5-digit display format with accuracy specified as ±1 count in 20,000 according to the manufacturer datasheet. These characteristics suit digital panel meters, laboratory instruments, process monitoring, and equipment requiring a stable numeric readout rather than a high-speed waveform acquisition.

The dual-slope conversion architecture integrates the input and reference over controlled periods. A 3 samples-per-second maximum conversion rate favors readable displays and ordinary low-frequency measurements rather than audio, communications, or motor-control sampling. The 2.0000 V full-scale reference capability provides a defined measurement range when paired with suitable input scaling, while the differential input arrangement helps reject common-mode voltage when both input paths are driven appropriately.

Typical applications include laboratory digital voltmeters, panel-based process indicators, weighing and laboratory instrumentation, and embedded numeric measurement systems. In each case, the converter's BCD output and display drivers can reduce the host-controller workload. The 28-pin PDIP format also remains convenient for through-hole industrial control boards, provided the board layout includes adequate clearance around the device.

When laying out the circuit, follow the manufacturer datasheet for reference, integration, input, and display-driver connections. Place sensitive input and reference paths away from switching nodes and display-driver return currents. Confirm that the selected display type, drive configuration, timing components, and reference voltage match the intended meter architecture before releasing the PCB.

This page organizes the ICL7135CNG4 specifications, package information, comparison options, and application guidance into an engineering-focused reference. It also identifies verified drop-in candidates and highlights the design trade-offs that matter when selecting a dual-slope display-oriented ADC.

드롭인 대체품: ICL7135CNG4 — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 시리즈의 변형

다음과 드롭인 호환되는 동일 시리즈 모델: ICL7135CNG4 (동일 폼 팩터 및 풋프린트) — 차이점: Package, Output Format.

Texas Instruments
Package: 28-pin DIP
Output Format: Multiplexed BCD output
비교 대상: ICL7135CNG4 →
Maxim Integrated
Package: 28-pin plastic DIP
비교 대상: ICL7135CNG4 →

ICL7135CPI+

✅ 드롭인
Maxim Integrated
📦 28-pin PDIP
4.5-digit dual-slope analog-to-digital converter · Multiplexed binary-coded decimal (BCD) · ±1 count in 20,000 · 2.0000 V · Differential, high impedance · 28-pin plastic DIP · 28 pins · 4 multiplexed digit-drive positions

가격 문의

데이터시트 보기 →

ICL7135CPI+2

✅ 드롭인
📦 28-pin PDIP
Same 4.5-digit BCD dual-slope family and 28-pin PDIP format; ordering-suffix conditions must be verified

📋 참조 대체품 (카탈로그에 없음)

ICL7135CNG4 최대 정격 & 전기적 특성

ADC Type Dual-slope ADC
분해능 4.5 digits
Channel Count 1 channel
Maximum Conversion Rate 3 samples/s
Output Format Multiplexed binary-coded decimal (BCD)
Display Type 7-segment LED or LCD
Input Configuration True differential input
Typical Input Current 1 pA
Full-Scale Reference 2.0000 V
Accuracy ±1 count in 20,000
Zero Reading for 0 V Input Supported
Precision Null Detection True polarity
Temperature Grade Commercial
패키지 28-pin PDIP, 15.24 mm body width
실장 유형 Through-hole
Packaging Tube

ICL7135CNG4 28-pin pdip, 15.24 mm body width 핀 구성 가이드

ICL7135CNG4(28-pin pdip, 15.24 mm body width 패키지)의 핀 구성입니다. 이 아날로그 부품에는 입력, 출력, 전원 공급 핀이 있습니다. 오프셋 널, 보상, 인에이블 핀 구성은 제조사 데이터시트를 참조하십시오. 신호 컨디셔닝 및 증폭기 회로에 이상적입니다.

ICL7135CNG4의 28-pin pdip, 15.24 mm body width 패키지 핀아웃 다이어그램

다음에 대한 상세 핀아웃 데이터 없음: ICL7135CNG4.

다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.

일반적인 애플리케이션

ICL7135CNG4 적합 용도: 6 애플리케이션s: Digital Panel Meter, Laboratory Digital Voltmeter, Process Monitoring Indicator, Precision Temperature Display, Weighing Scale Readout, Laboratory Data Logger Front End.

📺

Digital Panel Meter

The ICL7135CNG4 fits digital panel meters because it combines a 4.5-digit dual-slope ADC, multiplexed BCD output, and seven-segment display drivers in one 28-pin PDIP device. At up to 3 samples/s, it produces a readable numerical indication rather than a high-speed data stream. The converter can be placed behind a scaled input network for DC voltage or current measurement, while its true differential input helps reduce common-mode sensitivity. In a meter designed around the manufacturer reference circuit, the display driver outputs directly support the digit and segment multiplexing arrangement. The design trade-off is that the tube-packaged through-hole package requires board space and manual or through-hole assembly, making it more appropriate for established instrument formats than compact wearable products.

🔧

Laboratory Digital Voltmeter

The ICL7135CNG4 is suitable for a laboratory digital voltmeter when the priority is stable, readable voltage measurement. Its 4.5-digit format supports resolution beyond a conventional 3.5-digit display, and the ±1 count in 20,000 accuracy specification provides a defined conversion-performance basis. The 2.0000 V full-scale reference can support a scaled front end, while true differential input is useful when both measurement inputs are referenced carefully. A 3 samples/s update rate is appropriate for an instrument that presents continuously refreshed readings to an operator. Engineers should use the manufacturer’s reference and integration guidance, keep sensitive analog traces compact, and avoid routing display return current through the input and reference ground paths.

🏭

Process Monitoring Indicator

The ICL7135CNG4 can serve as the measurement core of an industrial process-monitoring indicator when the process variable changes slowly and must be presented numerically. The 4.5-digit BCD result and integrated seven-segment drivers simplify a display-oriented design, while the 3 samples/s conversion rate provides continuous updates without excessive conversion activity. A transmitter or resistive sensor can be conditioned into the converter’s differential input range, and the 2.0000 V full-scale reference establishes the measurement endpoint. For panel equipment, the commercial-grade 28-pin PDIP package is easy to inspect and service. The main implementation concern is electrical isolation: the timing, reference, and analog input sections should follow the datasheet layout so switching displays or nearby industrial circuits do not degrade the displayed measurement.

🧩

Precision Temperature Display

A temperature display benefits from the ICL7135CNG4’s 4.5-digit resolution, true differential input, and integrated display drive. The converter can digitize the output of a suitable linear temperature sensor or bridge stage, with the external analog network scaled so the expected temperature range occupies a useful portion of the 2.0000 V full-scale reference. A 3 samples/s update rate is ample for a readable panel indication and prevents excessive display flicker. Differential measurement is valuable because it allows the converter to compare two related sensor signals and reduce common-mode error when the sensor and electronics share a ground reference. Careful input protection, filtering, and reference decoupling are essential near thermocouple or sensor wiring, and the manufacturer pin and application diagrams should govern the final layout.

⚖️

Weighing Scale Readout

The ICL7135CNG4 is appropriate for a weighing-scale readout when the load-cell signal is converted through a low-noise analog front end and displayed as a four-and-a-half-digit value. Its dual-slope architecture is well matched to the relatively slow mechanical response of a scale, and the 3 samples/s conversion rate is sufficient for an operator-facing display. The BCD output and seven-segment drive functions reduce the number of external display-interface components. A 1 pA typical input current is valuable in high-impedance front ends, although the complete system must also satisfy offset, reference, and leakage requirements. Mechanical vibration near the converter can disturb a high-resolution measurement, so the PCB should be mechanically isolated as appropriate and sensitive analog routing should avoid display-driver currents.

🖥️

Laboratory Data Logger Front End

The ICL7135CNG4 can form the display-oriented measurement front end of a laboratory data logger for slow-moving voltage inputs. Its 4.5-digit BCD output provides a straightforward interface to a display controller or host system, and the 3 samples/s rate is suitable for supervisory readings rather than high-rate sampling. The true differential input can simplify comparison and ratiometric measurements when both channels are carefully buffered. Because the integrated display drivers are intended for segmented outputs, a logger requiring binary data, higher sample rates, or low-power operation may be better served by a different ADC family. In this application, select suitable protection and filtering components, maintain a clean reference network, and separate display return currents from precision analog ground paths to preserve measurement stability.

추천 제품 요약

CD4536BM96 Timing companion for precision meter front ends 사용처: Digital Panel Meter, Laboratory Digital Voltmeter, Process Monitoring Indicator, Precision Temperature Display, Weighing Scale Readout CD4053BME4 Analog multiplexing companion for selectable measurement inputs 사용처: Digital Panel Meter, Process Monitoring Indicator, Laboratory Data Logger Front End AD9544BCPZ Analog Devices 사용처: Laboratory Digital Voltmeter, Precision Temperature Display, Weighing Scale Readout, Laboratory Data Logger Front End
What is the ICL7135CNG4?
The ICL7135CNG4 is a 4.5-digit, one-channel dual-slope ADC with multiplexed BCD output and integrated seven-segment display drivers. According to the Texas Instruments datasheet, it performs up to 3 conversions per second and is packaged in a 28-pin PDIP. Its true differential input and 1 pA typical input current make it appropriate for precision panel meters, laboratory instruments, and low-frequency measurement systems.
What are the key specifications of ICL7135CNG4 that engineers should know?
The ICL7135CNG4 provides 4.5-digit resolution, one analog input channel, a maximum conversion rate of 3 samples/s, and multiplexed BCD output. It includes seven-segment display drivers for LED or LCD displays, true differential input, 1 pA typical input current, and a 2.0000 V full-scale reference. The commercial-grade device uses a through-hole 28-pin PDIP package supplied in a tube, making its electrical and mechanical characteristics clear for meter-board designs.
Where can I download the ICL7135CNG4 datasheet PDF?
The ICL7135CNG4 datasheet can be downloaded from the manufacturer-linked PDF page listed on this page. The document is identified as the Texas Instruments data for a 4.5-digit precision analog-to-digital converter and includes the device description, electrical characteristics, pin assignments, and application information. Use that document as the controlling reference for reference voltage, timing components, input configuration, display connections, and operating limits.
Where can I find the ICL7135CNG4 pinout?
The ICL7135CNG4 pinout is documented in the Texas Instruments datasheet under the pin-configuration and connection diagrams. The device has 28 pins in a PDIP package, with functions associated with analog input, reference, power, timing, BCD output, and display drive. Use the package diagram and pin-description table when assigning PCB nets because individual BCD and digit-drive functions are multiplexed across the output pins.
Is ICL7135CNG4 suitable for a digital panel meter?
Yes, the ICL7135CNG4 is suitable for a digital panel meter because it combines a 4.5-digit dual-slope converter with multiplexed BCD output and seven-segment display drivers. Its 3 samples/s conversion rate prioritizes a stable readable indication over high-speed sampling, while true differential input can improve rejection of common-mode voltage. It fits meters for DC voltage, current, resistance, temperature, and process variables when the analog front end is scaled correctly.
How fast is the ICL7135CNG4 ADC?
The ICL7135CNG4 has a maximum conversion rate of 3 samples per second. This rate is appropriate for continuously refreshed numerical panel displays, laboratory meters, and slow process measurements. It is not intended for high-frequency waveform capture, audio processing, or communications. The dual-slope method favors measurement stability and interference rejection, while the displayed result can update at a rate that remains comfortable for an operator to read.
What does dual-slope ADC mean for the ICL7135CNG4?
Dual-slope conversion means the ICL7135CNG4 measures the input by integrating it over a defined period and comparing that integration with a reference interval. This ADC method is a data-conversion technique within the broader ADC and integrated-circuit categories. It is especially useful for numeric meters because it naturally rejects some periodic interference and pairs well with a reference circuit, timing network, and seven-segment display.
What is the difference between ICL7135CNG4 and ICL7135CPI+?
The ICL7135CNG4 and ICL7135CPI+ are both described as 4.5-digit BCD-output dual-slope ADCs in 28-pin PDIP packages, so they share the principal measurement function and pin count. The suffix and ordering information distinguish their specific qualification and ordering variants. Confirm every pin function, timing value, temperature limit, and marking requirement in the manufacturer documentation before treating either ordering code as a production replacement.
What is the difference between ICL7135CNG4 and ICL7135CPI+2?
The ICL7135CNG4 and ICL7135CPI+2 are both listed as 28-pin PDIP, 4.5-digit BCD-output converters from the same device family. Their family-level architecture is similar, but the ordering suffixes can represent different grade, package, or lead-free conditions. Verify the exact suffix definition and every electrical limit before substitution because a shared package and conversion format alone do not guarantee identical production qualification.
When should I choose ICL7135CNG4 over ICL7135CPI+?
Choose ICL7135CNG4 when the required production specification explicitly identifies that ordering code and its commercial-grade 28-pin PDIP implementation. Choose ICL7135CPI+ only after checking its exact suffix definition, temperature grade, and datasheet limits against the intended product requirements. Both parts are associated with the same 4.5-digit dual-slope family, so the deciding factors are the approved ordering configuration, qualification needs, and verified electrical equivalence.
Is ICL7135CNG4 the same as ICL7106CPLZ?
No, the ICL7135CNG4 should not be assumed to be interchangeable with the ICL7106CPLZ merely because both are precision display-oriented ADCs. The ICL7135CNG4 is identified as a 4.5-digit, one-channel dual-slope converter in a 28-pin PDIP, whereas the ICL7106 family requires its own pin and electrical comparison. Use the ICL7106CPLZ comparison and manufacturer documentation to determine whether a redesign or a qualified substitution is required.
What can replace ICL7135CNG4?
The closest identified drop-in candidates are the ICL7135CPI+ and ICL7135CPI+2 because they share the ICL7135 family architecture, 4.5-digit BCD output, 28-pin PDIP format, and commercial temperature class. Before replacing ICL7135CNG4, verify the exact pin functions, reference requirements, timing values, electrical limits, and ordering suffix against the approved device specification. No other substitute is presented as a verified drop-in candidate.
Where can I buy ICL7135CNG4 online?
Use the Request a Quote form on this page to request ICL7135CNG4 availability, current unit pricing, quantity breaks, and lead time. The form provides a direct purchasing channel without embedding a price that may change. For production planning, request the exact ICL7135CNG4 ordering code and confirm tube packaging, quantity multiples, delivery timing, and any lifecycle constraints in the quotation response.
How much does ICL7135CNG4 cost?
Current ICL7135CNG4 pricing depends on quantity, availability, and market conditions and is therefore not reproduced as a static figure on this page. Submit the Request a Quote form with your required quantity and tube-packaging preference to obtain a current quotation. The request should also cover scheduled delivery quantities so that sourcing can distinguish prototype requirements from production replenishment.
What is the lead time for ICL7135CNG4?
The current ICL7135CNG4 lead time depends on supplier inventory and the requested production quantity. Request it through the Request a Quote form on this page, specifying quantity, target date, and whether staged deliveries are acceptable. For a new instrument design, treat lead time as a schedule dependency and obtain written confirmation before committing the mechanical release, test plan, and production build date.

엔지니어링 참조 데이터: ICL7135CNG4 — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the ICL7135CNG4 when the product needs a dedicated 4.5-digit numerical display, a one-channel dual-slope measurement stage, and a commercial-grade 28-pin PDIP implementation. Its integrated seven-segment drivers and multiplexed BCD output simplify panel-meter electronics, while the 3 samples/s rate matches slow-moving process variables and laboratory instruments rather than waveform acquisition. ICL7135CPI+ is the closest identified alternative because it shares the same family architecture, package, and BCD output; select it only after confirming the ordering suffix, qualification, and exact electrical limits. ICL7135CPI+2 is likewise a package-matched family candidate with similar architecture. Neither alternative should replace the ICL7135CNG4 without a pin-by-pin and specification-level review. If the design needs higher sampling speed, compact surface-mount construction, binary output, or a lower-power architecture, select a different ADC class because these candidates retain the display-oriented dual-slope architecture.

대체품과의 비교

파라미터 이 제품 ICL7135CPI+ ICL7135CPI+2
Brand Texas Instruments Texas Instruments Texas Instruments
Package 28-pin PDIP 28-pin PDIP 28-pin PDIP
Converter Architecture Dual-slope ADC Dual-slope ADC Dual-slope ADC
Resolution 4.5 digits 4.5 digits 4.5 digits
Output Format Multiplexed BCD Multiplexed BCD Multiplexed BCD
Full-Scale Reference 2.0000 V 2.0000 V 2.0000 V
Accuracy ±1 count in 20,000 ±1 count in 20,000 ±1 count in 20,000
Temperature Grade Commercial Commercial Commercial
Mounting Type Through-hole Through-hole Through-hole

주요 차별점

  • Integrated measurement and display interface (vs ICL7135CPI+)
  • Differential measurement input (vs ICL7135CPI+2)
  • Readable display-oriented conversion rate (vs ICL7135CPI+)

설계 노트

Route the analog input, reference, and integration paths away from the multiplexed BCD and seven-segment display outputs. Display-driver currents can couple into sensitive measurement nodes, particularly when the converter is resolving a small difference near full scale. Follow the manufacturer’s recommended application layout, keep analog and digital return currents separated as far as practical, and place input filtering and reference components close to their associated pins.

Design the supply rails and reference network to satisfy the ICL7135CNG4 absolute maximum ratings and operating conditions before calculating error budget. The 2.0000 V full-scale reference capability is a system reference point, not permission to exceed the device’s specified supply range. Use stable reference components, adequate decoupling, and defined startup behavior. Confirm the selected reference and supply tolerances against the required overall measurement accuracy rather than treating the converter accuracy as the complete system error.

Do not assume that a shared package makes every ICL7135 ordering suffix automatically interchangeable. The verified candidates share the 28-pin PDIP format and family-level conversion function, but the suffix can change ordering, grade, or qualification conditions. Before substitution, compare every pin name and function, the reference and integration networks, timing limits, temperature range, electrical characteristics, and package marking against the released design.

The 3 samples/s conversion rate is intentional for readable dual-slope measurements and should not be treated as a general-purpose sampling limit. If the design requires audio bandwidth, waveform capture, rapid process tracking, or sampled data storage, select an ADC with a substantially higher conversion rate and a suitable data interface. For a stable panel meter, the lower rate can instead reduce display activity and simplify the operator experience.

규정 준수 정보

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
무연
Unknown
무할로겐
Unknown
분쟁 광물
Unknown

No explicit compliance declaration was identified for ICL7135CNG4. AEC-Q100 is not applicable because this is a commercial-grade precision ADC rather than an automotive-qualified device.

데이터 검증일: 2026-11-24 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

ICL7135CNG4 ICL7135CNG4 datasheet ICL7135CNG4 pinout ICL7135CNG4 datasheet pdf ICL7135CNG4 equivalent ICL7135CNG4 replacement ICL7135CNG4 vs ICL7135CPI+ Texas Instruments ICL7135CNG4 ICL7135CNG4 28-pin PDIP ICL7135CNG4 digital panel meter ICL7135CNG4 price ICL7135CNG4 stock

관련 부품 & 용어

Texas Instruments ICL7135CNG4 ICL7135CPI+ ICL7135CPI+2 ICL7106CPLZ dual-slope ADC analog-to-digital converter ADC data converter integrated circuit 4.5-digit BCD multiplexed BCD output seven-segment display driver LED display LCD display true differential input 2.0000 V full-scale reference PDIP-28 through-hole package tube packaging digital panel meter laboratory voltmeter process monitoring integrating ADC power supply rejection ratio
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기