ICL7135CNG4 - 4.5-Digit Dual-Slope ADC | Texas Instruments
MPN: ICL7135CNG4 ✓ نشطICL7135CNG4 نظرة عامة
A dual-slope ADC is a signal-conditioning and conversion category that integrates an input signal over a fixed interval and compares the result with a reference time. This integrating approach is well suited to meters and panel displays because it rejects periodic interference, provides good noise performance, and avoids the complexity of a high-speed flash converter. Within the broader hierarchy, the ICL7135CNG4 is an ADC, then a data converter, then an integrated circuit used in electronic measurement systems.
Key features include one analog input channel, 4.5-digit BCD output, multiplexed seven-segment display drive, and support for LED or LCD display types. The device supports a 4.5-digit display format with accuracy specified as ±1 count in 20,000 according to the manufacturer datasheet. These characteristics suit digital panel meters, laboratory instruments, process monitoring, and equipment requiring a stable numeric readout rather than a high-speed waveform acquisition.
The dual-slope conversion architecture integrates the input and reference over controlled periods. A 3 samples-per-second maximum conversion rate favors readable displays and ordinary low-frequency measurements rather than audio, communications, or motor-control sampling. The 2.0000 V full-scale reference capability provides a defined measurement range when paired with suitable input scaling, while the differential input arrangement helps reject common-mode voltage when both input paths are driven appropriately.
Typical applications include laboratory digital voltmeters, panel-based process indicators, weighing and laboratory instrumentation, and embedded numeric measurement systems. In each case, the converter's BCD output and display drivers can reduce the host-controller workload. The 28-pin PDIP format also remains convenient for through-hole industrial control boards, provided the board layout includes adequate clearance around the device.
When laying out the circuit, follow the manufacturer datasheet for reference, integration, input, and display-driver connections. Place sensitive input and reference paths away from switching nodes and display-driver return currents. Confirm that the selected display type, drive configuration, timing components, and reference voltage match the intended meter architecture before releasing the PCB.
This page organizes the ICL7135CNG4 specifications, package information, comparison options, and application guidance into an engineering-focused reference. It also identifies verified drop-in candidates and highlights the design trade-offs that matter when selecting a dual-slope display-oriented ADC.
بدائل مباشرة لـ ICL7135CNG4 — نفس الحزمة، متوافق دبوس بدبوس. تُستثنى القطع ذات الحزم المختلفة التي تتطلب تعديل PCB.
الطرازات في هذه السلسلة
طرازات من نفس السلسلة متوافقة تمامًا مع ICL7135CNG4 (نفس عامل الشكل والبصمة) — يختلف في Package, Output Format.
ICL7135CPI+
✅ بديل مباشرتواصل لمعرفة السعر
عرض ورقة البيانات ←ICL7135CPI+2
✅ بديل مباشر📋 بديل مرجعي (غير موجود في الكتالوج)
ICL7135CNG4 الحدود القصوى والخصائص الكهربائية
| ADC Type | Dual-slope ADC |
| الدقة | 4.5 digits |
| Channel Count | 1 channel |
| Maximum Conversion Rate | 3 samples/s |
| Output Format | Multiplexed binary-coded decimal (BCD) |
| Display Type | 7-segment LED or LCD |
| Input Configuration | True differential input |
| Typical Input Current | 1 pA |
| Full-Scale Reference | 2.0000 V |
| Accuracy | ±1 count in 20,000 |
| Zero Reading for 0 V Input | Supported |
| Precision Null Detection | True polarity |
| Temperature Grade | Commercial |
| العلبة | 28-pin PDIP, 15.24 mm body width |
| نوع التركيب | Through-hole |
| Packaging | Tube |
دليل تكوين أطراف ICL7135CNG4 28-pin pdip, 15.24 mm body width
تكوين الأطراف لـ ICL7135CNG4 (حزمة 28-pin pdip, 15.24 mm body width). يتميز هذا المكوّن التناظري بأطراف الإدخال والإخراج وإمداد الطاقة. راجع ورقة بيانات الشركة المصنعة لتكوينات طرف إلغاء الإزاحة والتعويض والتمكين. مثالي لدوائر تكييف الإشارة والمضخمات.
لا تتوفر بيانات مفصلة لمخطط التوصيلات لـ ICL7135CNG4.
راجع ورقة البيانات للحصول على تكوين الأطراف الكامل.
التطبيقات النموذجية
ICL7135CNG4 مناسب لـ 6 التطبيقs: Digital Panel Meter, Laboratory Digital Voltmeter, Process Monitoring Indicator, Precision Temperature Display, Weighing Scale Readout, Laboratory Data Logger Front End.
Digital Panel Meter
The ICL7135CNG4 fits digital panel meters because it combines a 4.5-digit dual-slope ADC, multiplexed BCD output, and seven-segment display drivers in one 28-pin PDIP device. At up to 3 samples/s, it produces a readable numerical indication rather than a high-speed data stream. The converter can be placed behind a scaled input network for DC voltage or current measurement, while its true differential input helps reduce common-mode sensitivity. In a meter designed around the manufacturer reference circuit, the display driver outputs directly support the digit and segment multiplexing arrangement. The design trade-off is that the tube-packaged through-hole package requires board space and manual or through-hole assembly, making it more appropriate for established instrument formats than compact wearable products.
موصى به
Laboratory Digital Voltmeter
The ICL7135CNG4 is suitable for a laboratory digital voltmeter when the priority is stable, readable voltage measurement. Its 4.5-digit format supports resolution beyond a conventional 3.5-digit display, and the ±1 count in 20,000 accuracy specification provides a defined conversion-performance basis. The 2.0000 V full-scale reference can support a scaled front end, while true differential input is useful when both measurement inputs are referenced carefully. A 3 samples/s update rate is appropriate for an instrument that presents continuously refreshed readings to an operator. Engineers should use the manufacturer’s reference and integration guidance, keep sensitive analog traces compact, and avoid routing display return current through the input and reference ground paths.
موصى به
Process Monitoring Indicator
The ICL7135CNG4 can serve as the measurement core of an industrial process-monitoring indicator when the process variable changes slowly and must be presented numerically. The 4.5-digit BCD result and integrated seven-segment drivers simplify a display-oriented design, while the 3 samples/s conversion rate provides continuous updates without excessive conversion activity. A transmitter or resistive sensor can be conditioned into the converter’s differential input range, and the 2.0000 V full-scale reference establishes the measurement endpoint. For panel equipment, the commercial-grade 28-pin PDIP package is easy to inspect and service. The main implementation concern is electrical isolation: the timing, reference, and analog input sections should follow the datasheet layout so switching displays or nearby industrial circuits do not degrade the displayed measurement.
موصى به
Precision Temperature Display
A temperature display benefits from the ICL7135CNG4’s 4.5-digit resolution, true differential input, and integrated display drive. The converter can digitize the output of a suitable linear temperature sensor or bridge stage, with the external analog network scaled so the expected temperature range occupies a useful portion of the 2.0000 V full-scale reference. A 3 samples/s update rate is ample for a readable panel indication and prevents excessive display flicker. Differential measurement is valuable because it allows the converter to compare two related sensor signals and reduce common-mode error when the sensor and electronics share a ground reference. Careful input protection, filtering, and reference decoupling are essential near thermocouple or sensor wiring, and the manufacturer pin and application diagrams should govern the final layout.
موصى به
Weighing Scale Readout
The ICL7135CNG4 is appropriate for a weighing-scale readout when the load-cell signal is converted through a low-noise analog front end and displayed as a four-and-a-half-digit value. Its dual-slope architecture is well matched to the relatively slow mechanical response of a scale, and the 3 samples/s conversion rate is sufficient for an operator-facing display. The BCD output and seven-segment drive functions reduce the number of external display-interface components. A 1 pA typical input current is valuable in high-impedance front ends, although the complete system must also satisfy offset, reference, and leakage requirements. Mechanical vibration near the converter can disturb a high-resolution measurement, so the PCB should be mechanically isolated as appropriate and sensitive analog routing should avoid display-driver currents.
موصى به
Laboratory Data Logger Front End
The ICL7135CNG4 can form the display-oriented measurement front end of a laboratory data logger for slow-moving voltage inputs. Its 4.5-digit BCD output provides a straightforward interface to a display controller or host system, and the 3 samples/s rate is suitable for supervisory readings rather than high-rate sampling. The true differential input can simplify comparison and ratiometric measurements when both channels are carefully buffered. Because the integrated display drivers are intended for segmented outputs, a logger requiring binary data, higher sample rates, or low-power operation may be better served by a different ADC family. In this application, select suitable protection and filtering components, maintain a clean reference network, and separate display return currents from precision analog ground paths to preserve measurement stability.
موصى به
ملخص المنتجات الموصى بها
بيانات مرجعية هندسية لـ ICL7135CNG4 — المقارنة وإرشادات التصميم ومعلومات الامتثال.
دليل الاختيار
المقارنة مع البدائل
| المعامل | هذا المنتج | ICL7135CPI+ | ICL7135CPI+2 |
|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 28-pin PDIP | 28-pin PDIP | 28-pin PDIP |
| Converter Architecture | Dual-slope ADC | Dual-slope ADC | Dual-slope ADC |
| Resolution | 4.5 digits | 4.5 digits | 4.5 digits |
| Output Format | Multiplexed BCD | Multiplexed BCD | Multiplexed BCD |
| Full-Scale Reference | 2.0000 V | 2.0000 V | 2.0000 V |
| Accuracy | ±1 count in 20,000 | ±1 count in 20,000 | ±1 count in 20,000 |
| Temperature Grade | Commercial | Commercial | Commercial |
| Mounting Type | Through-hole | Through-hole | Through-hole |
أبرز الفروقات
- Integrated measurement and display interface (مقابلICL7135CPI+)
- Differential measurement input (مقابلICL7135CPI+2)
- Readable display-oriented conversion rate (مقابلICL7135CPI+)
ملاحظات التصميم
Route the analog input, reference, and integration paths away from the multiplexed BCD and seven-segment display outputs. Display-driver currents can couple into sensitive measurement nodes, particularly when the converter is resolving a small difference near full scale. Follow the manufacturer’s recommended application layout, keep analog and digital return currents separated as far as practical, and place input filtering and reference components close to their associated pins.
Design the supply rails and reference network to satisfy the ICL7135CNG4 absolute maximum ratings and operating conditions before calculating error budget. The 2.0000 V full-scale reference capability is a system reference point, not permission to exceed the device’s specified supply range. Use stable reference components, adequate decoupling, and defined startup behavior. Confirm the selected reference and supply tolerances against the required overall measurement accuracy rather than treating the converter accuracy as the complete system error.
Do not assume that a shared package makes every ICL7135 ordering suffix automatically interchangeable. The verified candidates share the 28-pin PDIP format and family-level conversion function, but the suffix can change ordering, grade, or qualification conditions. Before substitution, compare every pin name and function, the reference and integration networks, timing limits, temperature range, electrical characteristics, and package marking against the released design.
The 3 samples/s conversion rate is intentional for readable dual-slope measurements and should not be treated as a general-purpose sampling limit. If the design requires audio bandwidth, waveform capture, rapid process tracking, or sampled data storage, select an ADC with a substantially higher conversion rate and a suitable data interface. For a stable panel meter, the lower rate can instead reduce display activity and simplify the operator experience.
معلومات الامتثال
No explicit compliance declaration was identified for ICL7135CNG4. AEC-Q100 is not applicable because this is a commercial-grade precision ADC rather than an automotive-qualified device.