INA111APG4 - High-Speed FET-Input Instrumentation Amplifier | Texas Instruments
MPN: INA111APG4 ✓ 啟用中INA111APG4 概覽
An instrumentation amplifier is a specialized analog signal-conditioning IC that amplifies the voltage difference between two inputs while rejecting signals common to both inputs. Its internal three-op-amplifier architecture provides high input impedance and consistent gain-setting behavior. This places the INA111 in the amplifier hierarchy of analog ICs and instrumentation amplifiers, where it supports sensor interfaces, bridge amplifiers, current measurement, and laboratory acquisition systems without requiring a separate input-buffer stage.
Principal features include a maximum input bias current of 20 pA, a maximum input offset voltage of 500 µV, a maximum offset-voltage drift of 5 µV/°C, and a minimum common-mode rejection ratio of 106 dB. The device also provides high-speed operation with a listed 2 MHz bandwidth. These characteristics make it especially useful when the source presents very high impedance, when small differential signals must be measured in the presence of a much larger common-mode voltage, or when measurement bandwidth must exceed that of a general-purpose precision amplifier.
The INA111 uses a three-amplifier instrumentation-amplifier architecture. Its FET input stage limits input bias current, while the differential signal is amplified according to an external gain-setting resistor. The listed 106 dB minimum common-mode rejection helps suppress common-mode voltage in industrial sensor systems, while the 2 MHz bandwidth allows the device to process signals beyond the static-measurement range associated with many precision op amps. Its single-ended output is intended for use with external analog-to-digital converters, filters, and downstream acquisition circuitry.
Typical applications include low-current sensor conditioning, strain-gauge and resistance-bridge measurement, precision current sensing, high-impedance laboratory probes, and industrial process-monitoring inputs. In a bridge circuit, the amplifier converts a small differential bridge excitation into a larger single-ended voltage. In a current-shunt system, its low bias current minimizes measurement error from high-resistance sense lines, while the high common-mode rejection helps preserve accuracy when the shunt signal is superimposed on a larger supply voltage.
Design should preserve the distinction between input bias current, input offset voltage, and the common-mode voltage range. Place the gain-setting resistor close to the appropriate device pins, route sensitive input traces away from switching nodes and power-converter currents, and use a suitable reference arrangement when the output must remain centered in a unipolar converter range. Verify bandwidth, output-swing limits, supply headroom, and input protection against the actual sensor and ADC requirements.
This page combines manufacturer specifications, package and ordering information, comparison parameters, and practical circuit-design guidance for engineers evaluating the INA111APG4 as a high-speed FET-input instrumentation amplifier.
直接替換替代品,適用於 INA111APG4 — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: INA111APG4 (相同外形與佔位) — 差異在於 Common-Mode Rejection Ratio, Input Bias Current, Mounting Type, Package.
INA111BU
✅ 直接替換聯絡詢價
查看資料表 →INA114APG4
✅ 直接替換📋 參考替代品(不在目錄中)
INA111APG4 最大額定值與電氣特性
| Amplifier Type | Instrumentation amplifier |
| Number of Amplifier Circuits | 1 circuit |
| Internal Architecture | 3-op-amplifier design |
| Input Bias Current | 20 pA maximum |
| Input Offset Voltage | 500 µV maximum |
| Input Offset Voltage Drift | 5 µV/°C maximum |
| Common-Mode Rejection Ratio | 106 dB minimum |
| Bandwidth | 2 MHz |
| 輸出類型 | Single-ended |
| 封裝 | 8-pin plastic DIP |
| 安裝類型 | Through-hole |
| RoHS 狀態 | RoHS compliant |
INA111APG4 8-pin plastic dip 腳位配置指南
INA111APG4(8-pin plastic dip 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: INA111APG4.
請參閱 資料表 以查看完整腳位配置。
典型應用
INA111APG4 適用於 6 應用s: Precision Bridge Sensor Conditioning, High-Impedance Probe Amplification, Low-Current Shunt Measurement, Industrial Process Measurement, Laboratory Data Acquisition, Audio and Analog Signal Conditioning.
Precision Bridge Sensor Conditioning
The INA111APG4 is well suited to strain-gauge, load-cell, and resistive-bridge measurement because its 20 pA maximum input bias current limits the error introduced by high source impedance. Its 106 dB minimum common-mode rejection helps isolate the small differential bridge signal from excitation-related common-mode voltage. Place the device close to the bridge, route the two signal inputs symmetrically, and use the external gain-setting resistor to establish the required sensitivity. The 2 MHz bandwidth also leaves headroom for mechanical resonances and filtering above the primary measurement bandwidth. A suitable companion is the ADS1262IPW when a high-resolution converter is required.
推薦
High-Impedance Probe Amplification
The INA111APG4 can amplify signals from electrochemical, capacitive, or laboratory probes whose source impedance is high enough that input bias current matters. The listed maximum input bias current of 20 pA helps preserve sensor fidelity, while the minimum common-mode rejection ratio of 106 dB supports systems in which the common-mode voltage is much larger than the signal of interest. For practical layouts, minimize exposed trace area, use guarding where leakage can affect the measurement, and keep input capacitance low to preserve response. The device’s 2 MHz bandwidth makes it appropriate when the measurement includes content beyond static DC.
推薦
Low-Current Shunt Measurement
For low-current power monitoring, the INA111APG4 can amplify the differential voltage across a shunt while rejecting the supply-related common-mode voltage. Its 20 pA maximum input bias current is particularly helpful when using long, high-impedance sense connections that could otherwise introduce error. The common-mode rejection ratio of at least 106 dB supports accurate extraction of a relatively small shunt signal. Keep the Kelvin sense traces paired and away from high-current switching paths, and check the shunt’s power dissipation separately from the amplifier’s operating limits. The INA240A4DR is a useful alternative when the design requires a dedicated bidirectional current-sensing amplifier instead.
推薦
Industrial Process Measurement
The INA111APG4 is applicable to industrial process signals that arrive as small differential voltages over substantial common-mode voltage. Its 106 dB minimum common-mode rejection supports reliable extraction of sensor information in electrically noisy equipment, while the high-speed response can accommodate rapidly changing process variables. Use a protected input path, maintain a low-impedance reference for the output stage, and isolate the analog section from switching converters and high-current relays. The ADS1262IPW can serve as a companion when the measurement requires a high-resolution converter with integrated programmable gain and flexible excitation timing.
推薦
Laboratory Data Acquisition
The INA111APG4 provides a practical input stage for laboratory instruments that measure small differential signals over a larger common-mode voltage. The device’s 500 µV maximum offset voltage and 5 µV/°C maximum offset drift establish important limits for DC accuracy, while its 2 MHz bandwidth supports faster measurements than a purely static precision amplifier. Designers should account for the front-end’s noise, input capacitance, gain error, and the acquisition system’s ADC characteristics. Keep the gain resistor compact and use a clean analog ground reference. The ADS8519IDB is a suitable companion when multiple channels require simultaneous sampling.
推薦
Audio and Analog Signal Conditioning
The INA111APG4 can serve as a differential input stage for balanced audio or other low-level analog signals when low input bias current and common-mode rejection are important. Its single-ended output simplifies connection to a downstream ADC or voltage-processing stage. The 2 MHz bandwidth is substantially above the audible band, allowing signal-chain filtering without relying on an extremely narrow-band device. However, offset voltage and noise must be included in the overall signal-to-noise calculation, and the input network must preserve channel balance. Use a shielded or tightly routed input path, a stable reference, and suitable output filtering before conversion.
推薦
推薦產品摘要
工程參考資料,適用於 INA111APG4 — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | INA111BU | INA114APG4 |
|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 8-pin plastic DIP | 8-pin plastic DIP | 8-pin plastic DIP |
| Device Type | High-speed FET-input instrumentation amplifier | INA111-family instrumentation amplifier | Precision instrumentation amplifier |
| Internal Architecture | 3-op-amplifier design | 3-op-amplifier design | 3-op-amplifier design |
主要差異化特點
- Higher-bandwidth instrumentation-amplifier positioning (對比INA114APG4)
- Low-bias-current input stage (對比INA114APG4)
- Common-mode rejection suited to differential sensing (對比INA114APG4)
設計說明
Route the two input conductors as a matched pair and keep the external gain-setting resistor close to its designated pins. Place input protection components symmetrically so their leakage and capacitance do not unbalance the differential signal. Keep sensitive traces away from switching inductors, relay contacts, and high-current return paths. For high-impedance sources, reduce exposed PCB area and use guarding where its effect on leakage and capacitance has been evaluated.
Determine usable bandwidth at the selected closed-loop gain rather than relying only on the listed 2 MHz device bandwidth. Account for the gain-setting resistor’s parasitic capacitance, source capacitance, ADC input capacitance, and the bandwidth of the downstream filter. If the source is slow, added input capacitance can lengthen settling time; if it is fast, the input and output stages can limit system response. Use the manufacturer gain and application diagrams as the layout baseline.
Do not treat the 500 µV maximum input offset voltage as the only source of measurement error. Include offset drift, bias-current effects, gain error, resistor tolerance, ADC noise, and common-mode error in the uncertainty budget. Also verify the input common-mode range and output swing against the chosen supplies and reference voltage before assembly. These checks are essential when replacing INA111APG4 with INA114APG4 despite their common package and three-op-amplifier architecture.
合規資訊