INA111AUG4 - 2 MHz FET-Input Instrumentation Amp | TI
MPN: INA111AUG4 ✓ 啟用中INA111AUG4 概覽
An instrumentation amplifier is a specialized differential analog amplifier designed for sensor conditioning. Its internal architecture preserves signal integrity by rejecting common-mode noise while amplifying the difference between two inputs. The INA111 belongs to the broader instrumentation-amplifier family, which sits within amplifier ICs and analog signal-chain components used for bridge, current, pressure, temperature, and biomedical sensing.
The principal features of the INA111AUG4 include a 2 MHz gain bandwidth, FET inputs, a current-feedback topology, single-resistor gain selection, and laser-trimmed offset voltage and drift. The current-feedback architecture supports extended bandwidth at higher closed-loop gains and fast settling. One external gain resistor allows the same circuit to cover low-gain signal conditioning and gain values exceeding 1000, depending on application bandwidth requirements.
The INA111AUG4 is a single-amplifier device intended for precision differential measurement rather than general-purpose single-ended amplification. Its common-mode rejection improves measurement integrity when a sensor output is small relative to the voltage shared by both sensor terminals. Designers must still evaluate input common-mode range, output swing, supply voltage, gain-bandwidth distribution, resistor tolerance, and source impedance at the operating frequency.
Typical uses include bridge-transducer amplifiers, precision current sensing, laboratory instrumentation, medical monitoring, industrial sensor interfaces, and data-acquisition front ends. The device is particularly useful when a differential signal requires adjustable gain while retaining high speed and low input bias current. The SOIC package also supports conventional surface-mount assembly and compact analog circuit layouts.
For implementation, place the external gain resistor close to the gain-setting pin and route each input directly to minimize parasitic capacitance and pickup. Reference and power-ground paths should be planned so output-current return noise does not add directly to the input-referred signal. Confirm the usable bandwidth at the selected gain and verify the analog input limits against the supply rails.
This page combines the manufacturer product identity, distributor availability, package information, application guidance, comparison criteria, and design checks into an engineering-focused selection reference for the INA111AUG4.
直接替換替代品,適用於 INA111AUG4 — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: INA111AUG4 (相同外形與佔位) — 差異在於 Gain Range, Package, Product Type.
INA111AUE4
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
INA111AU
✅ 直接替換 ⚠️ 規格未經驗證聯絡詢價
查看資料表 →INA111AIPWR
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
INA111APWR
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
INA111AUG4 最大額定值與電氣特性
| Product Type | Instrumentation amplifier |
| Amplifier Circuit Count | 1 circuit |
| Input Stage | FET input |
| 拓撲 | Current feedback |
| Gain Bandwidth | 2 MHz |
| Gain Range | 1 to over 1000 |
| Settling Time | 4 us to 0.01% at gain 100 |
| Gain Setting | 1 external resistor |
| Offset Voltage and Drift | Laser trimmed |
| 封裝 | 16-SOIC |
| Package Width | 7.50 mm (0.295 in) |
| 安裝類型 | Surface mount |
INA111AUG4 7.50 mm (0.295 in) 腳位配置指南
INA111AUG4(7.50 mm (0.295 in) 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: INA111AUG4.
請參閱 資料表 以查看完整腳位配置。
典型應用
INA111AUG4 適用於 6 應用s: Bridge Transducer Signal Conditioning, Precision Current Sensing, Industrial Sensor Interface, Medical Monitoring Front End, Data Acquisition and Instrumentation, Audio and Low-Level Signal Amplification.
Bridge Transducer Signal Conditioning
The INA111AUG4 fits bridge-based pressure, load-cell, and strain measurements where the useful signal is small and differential. Its FET input minimizes loading of high-impedance sources, while the current-feedback amplifier and 2 MHz gain bandwidth support sensor systems that need more bandwidth than a slow precision-only amplifier provides. A single external gain resistor establishes a closed-loop gain from 1 to over 1000, allowing the same circuit family to cover millivolt-level signals and larger bridge spans. The 16-SOIC layout should place the gain resistor close to the device, while the bridge excitation and reference return should use quiet routing. Confirm bridge impedance, excitation voltage, common-mode voltage, and the required measurement bandwidth before selecting the resistor value.
推薦
Precision Current Sensing
INA111AUG4 can condition a differential current signal when the sensing element and amplifier share a suitable common-mode voltage. The 2 MHz gain bandwidth allows the front end to respond to fast current transients, while external gain selection supports sensitivity adjustment without a complex switched-gain network. Its differential architecture helps reject supply and ground disturbances that appear equally on both measurement inputs. In a shunt-based design, keep the Kelvin connection narrow and route it away from switching nodes. The external gain resistor should have suitable tolerance and low temperature drift when measurement accuracy matters. Before implementation, verify the amplifier's input and output ranges, quiescent behavior, source impedance, and the system's required common-mode rejection across frequency.
推薦
Industrial Sensor Interface
The INA111AUG4 is appropriate for industrial sensing front ends that amplify a differential sensor output while rejecting a substantial common-mode voltage. Its high-speed current-feedback implementation supports signal bandwidth beyond many precision instrumentation amplifiers, and the FET input stage helps preserve the output of high-impedance sensors. Engineers can set gain from 1 to over 1000 with one resistor, making the device useful across pressure, position, isolation-interface, and process-control signal chains. The 16-SOIC package is compatible with standard surface-mount assembly. Industrial implementations should include input transient protection, verified grounding, and separation between sensitive input traces and switching power or digital return paths. Check the actual sensor excitation and operating-temperature requirements against the device limits.
推薦
Medical Monitoring Front End
INA111AUG4 can amplify low-level differential signals in biomedical monitoring equipment when the selected operating point satisfies the device's electrical limits. The FET input stage is useful with high-impedance sensing elements because it limits input bias-current loading, while differential amplification supports rejection of common-mode interference in electrode or sensor systems. Its 2 MHz bandwidth and 4 us settling to 0.01% at gain 100 provide useful response for dynamic physiological signals. The amplifier does not by itself satisfy medical-product safety or isolation requirements, so the complete circuit must include appropriate protection, leakage control, and qualification. Verify electrode voltage limits, input bias-current requirements, output headroom, patient protection, and applicable regulatory requirements before using this device in a medical path.
推薦
Data Acquisition and Instrumentation
INA111AUG4 serves as an analog input stage in laboratory and data-acquisition systems that measure differential voltages over a broader frequency range than a slow DC-only amplifier may support. User-selectable gain from 1 to over 1000 allows the front end to normalize signals with widely different amplitudes, while the 2 MHz gain bandwidth preserves response for higher-frequency components. The current-feedback topology and 4 us settling to 0.01% at gain 100 are particularly relevant to stepped or multiplexed measurement systems. Use short input paths, a clean reference return, and a stable low-noise supply. The instrumentation amplifier must remain within its input common-mode and output voltage limits at every gain and signal condition, and system calibration should account for resistor tolerance, offset, and drift.
推薦
Audio and Low-Level Signal Amplification
INA111AUG4 is applicable when a small balanced audio or instrumentation signal requires differential gain and flexible gain selection rather than ordinary single-ended amplification. The current-feedback architecture provides a 2 MHz gain-bandwidth characteristic, while single-resistor gain setting from 1 to over 1000 allows the circuit to accommodate line-level and lower-level balanced signals. Its FET inputs are advantageous when the source has relatively high impedance. The amplifier does not itself provide audio output drive, so it is best used as a preamplifier or measurement stage ahead of a suitable line driver. Keep the input loop small, maintain symmetric routing where possible, and verify that the output swing remains within the selected supply. Feedback-network stability and gain-bandwidth interaction should also be checked against the required audio bandwidth.
推薦
推薦產品摘要
工程參考資料,適用於 INA111AUG4 — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | INA111AUE4 | INA111AU | INA111AIPWR | INA111APWR |
|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC |
| Product Type | Instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier |
| Amplifier Circuit Count | 1 circuit | 1 circuit | 1 circuit | 1 circuit | 1 circuit |
| Gain Bandwidth | 2 MHz | 2 MHz | 2 MHz | 2 MHz | 2 MHz |
| Gain Range | 1 to over 1000 | 1 to over 1000 | 1 to over 1000 | 1 to over 1000 | 1 to over 1000 |
| Settling Time | 4 us to 0.01% at gain 100 | 4 us to 0.01% at gain 100 | 4 us to 0.01% at gain 100 | 4 us to 0.01% at gain 100 | 4 us to 0.01% at gain 100 |
| Input Stage | FET input | FET input | FET input | FET input | FET input |
| Topology | Current feedback | Current feedback | Current feedback | Current feedback | Current feedback |
| Gain Setting Method | 1 external resistor | 1 external resistor | 1 external resistor | 1 external resistor | 1 external resistor |
主要差異化特點
- High-speed current-feedback architecture (對比INA111AU)
- Single-resistor gain programming (對比INA111AUE4)
- FET input for high-impedance sources (對比INA111APWR)
- Fast settling at high gain (對比INA111AIPWR)
設計說明
Route the two differential inputs as a compact, symmetrical pair and connect them directly to the amplifier pins rather than sharing a long trace with other circuitry. Place the external gain resistor close to its designated package pin to minimize parasitic capacitance and susceptibility to interference. Keep the input loop small and maintain a continuous return path beneath the circuit. Because the package is a conventional 16-SOIC, confirm the exact manufacturer pin diagram before assigning the footprint.
Bandwidth and settling must be checked together at the selected closed-loop gain. The INA111AUG4 has a 2 MHz gain-bandwidth characteristic and is described as settling to 0.01% in 4 us at gain 100. Do not treat 2 MHz as the usable flat bandwidth at every gain; use the manufacturer gain and bandwidth curves for the final resistor value. Also evaluate source impedance, parasitic capacitance, and the sensor's own frequency response because these can alter both settling behavior and effective bandwidth.
Do not assume that the gain-setting resistor alone determines system accuracy. The external resistor tolerance and temperature coefficient contribute to gain error, while source imbalance can create additional differential input offset. Confirm that the sensor common-mode voltage remains inside the amplifier's operating range and that the output has adequate voltage swing at the selected supply and gain. A substitute ordering code may use the same 16-SOIC footprint while differing in grade, marking, or reel orientation, so verify those attributes before procurement.
Separate the sensitive input pair from switching-node copper, inductor connections, and high-current return paths. Use a quiet analog ground strategy and connect the sensor return to the amplifier ground at a controlled point rather than allowing input current to flow through the input reference trace. Place local supply bypass capacitance close to the device and keep its current loop compact. These measures prevent common-mode and supply disturbances from being converted into apparent differential signal at the sensor input.
合規資訊
Compliance status was not stated in the manufacturer or distributor results and remains unknown. Confirm RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals status against the current manufacturer product documentation before release.