MPN: INA2126UA ✓ 啟用中INA2126UA 概覽
An instrumentation amplifier is a specialized analog amplifier that combines differential input measurement, high input impedance, and accurate gain-setting in one package. Within the signal-chain hierarchy, it sits between sensors or bridge networks and higher-level ADC, control, or monitoring systems. Its differential architecture rejects common-mode interference while preserving the small voltage variations being measured.
The INA2126UA provides two amplifier channels, a 5 V/V to 10,000 V/V programmable gain range, and a gain error of no more than 0.04%. A typical input offset of 250 µV supports precision measurements, while the low 175 µA-per-channel quiescent current suits battery-powered and portable instrumentation. The device operates across an extended temperature range of -40°C to +85°C.
Internally, the INA2126 family uses a two-op-amp instrumentation-amplifier architecture. This structure provides a practical balance between low power, low noise, common-mode rejection, and user-programmable gain. The external resistor between the RG pins establishes the differential gain, allowing one device to serve multiple measurement ranges without changing the analog front end architecture.
Typical uses include bridge-transducer signal conditioning, portable measurement systems, battery-powered diagnostic equipment, industrial sensor interfaces, and low-current precision sensing. Its differential inputs are particularly useful when the source includes substantial common-mode voltage or interference relative to the wanted signal.
Design the layout around the RG resistor, input filtering, and supply grounding. Place the gain-setting resistor close to the device, provide adequate bypassing on both supply rails, and maintain a quiet return path to minimize errors that can dominate microvolt-level measurements. Use the pin-description table in the manufacturer datasheet when assigning PCB tracks and checking exposed alternatives.
This product page combines the manufacturer specifications with practical selection guidance, application analysis, pin-package context, and a parameter-by-parameter comparison. It is intended to help engineers identify whether the INA2126UA fits a low-power precision measurement design and how closely related same-family devices compare.
直接替換替代品,適用於 INA2126UA — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: INA2126UA (相同外形與佔位) — 差異在於 Maximum Voltage Gain, Package.
INA2126U
✅ 直接替換聯絡詢價
查看資料表 →INA2126UE4
✅ 直接替換📋 參考替代品(不在目錄中)
INA2126E/250G4
✅ 直接替換📋 參考替代品(不在目錄中)
INA2126UA 最大額定值與電氣特性
| Amplifier Type | Dual precision instrumentation amplifier |
| Number of Channels | 2 channels |
| Maximum Supply Voltage | 36 V |
| Minimum Supply Voltage | 2.7 V |
| Quiescent Current per Channel | 175 µA |
| Input Offset Voltage | 250 µV |
| Minimum Voltage Gain | 5 V/V |
| Maximum Voltage Gain | 10,000 V/V |
| Gain Error | 0.04% maximum |
| Gain-Bandwidth Product | 200 kHz |
| 工作溫度範圍 | -40°C to +85°C |
| 封裝 | 16-pin SOIC (D) |
| 安裝類型 | Surface mount |
INA2126UA 16-pin soic (d) 腳位配置指南
INA2126UA(16-pin soic (d) 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: INA2126UA.
請參閱 資料表 以查看完整腳位配置。
典型應用
INA2126UA 適用於 6 應用s: Portable Sensor Measurement, Bridge Transducer Signal Conditioning, Battery-Powered Diagnostic Equipment, Precision Current Sensing, Industrial Sensor Interfaces, Portable Data Acquisition.
Portable Sensor Measurement
The INA2126UA suits portable and battery-operated sensor systems because its 175 µA quiescent current per channel limits the amplifier's contribution to standby demand. Two precision differential channels can measure paired sensors while a 2.7 V minimum supply supports low-energy operation. Its 250 µV offset and programmable gain from 5 V/V to 10,000 V/V permit small sensor outputs to be amplified without requiring a separate low-noise amplifier. The practical trade-off is that output common-mode behavior, reference configuration, and available input headroom must be checked against the selected gain and supply voltage.
推薦
Bridge Transducer Signal Conditioning
The INA2126UA is appropriate for resistive bridge outputs because its differential input arrangement reduces common-mode pickup and supports programmable gains up to 10,000 V/V. A 250 µV maximum input offset and 0.04% maximum gain error help preserve measurement accuracy in compact industrial transducers. The external RG resistor makes it practical to match gain to the bridge sensitivity without changing the amplifier package. Engineers should verify excitation voltage, bridge output range, input common-mode limits, and the resistor tolerance needed to meet the final system error budget.
推薦
Battery-Powered Diagnostic Equipment
The dual-channel INA2126UA helps reduce the amplifier count in portable diagnostic instruments that acquire two related low-level signals. Its 175 µA-per-channel quiescent current supports a low-power design, while the 36 V maximum supply provides flexibility for higher-voltage diagnostic interfaces. Differential acquisition helps reject common-mode noise present on sensor wiring. Because the offset specification is 250 µV, the actual signal-to-error ratio depends strongly on sensor excitation and output amplitude; low-level channels may require calibration or a more precise gain-setting resistor.
推薦
Precision Current Sensing
The INA2126UA can amplify low differential voltages from current-sense elements in battery systems and industrial controllers. Differential inputs are useful when the sense voltage is small relative to its common-mode level, while programmable gain increases the usable ADC range without placing large signals directly on the converter input. The 250 µV offset must be evaluated against the target current resolution and shunt dissipation. Layout should use a compact sense path, avoid copper routes parallel to the low-level inputs, and provide local supply bypassing to prevent conducted noise from obscuring the measurement.
推薦
Industrial Sensor Interfaces
The INA2126UA offers a compact way to condition two industrial sensor outputs with high common-mode content. Its 36 V maximum supply accommodates a broader operating environment than low-voltage-only amplifiers, while the two-op-amp architecture maintains low power at 175 µA per channel. Gain can be selected from 5 V/V to 10,000 V/V using the external RG resistor, allowing one architecture to cover several sensor sensitivities. The design must still include input filtering, overvoltage protection, and reference selection appropriate to the expected common-mode and output ranges.
推薦
Portable Data Acquisition
The INA2126UA fits two-channel portable data-acquisition systems requiring precision differential inputs and limited operating power. The 2.7 V minimum supply supports compact low-voltage platforms, while 175 µA quiescent current per channel leaves more of the system power budget available to sensors and signal processing. Its 5 V/V to 10,000 V/V gain range covers many low-level transducer outputs. For high-resolution conversion, evaluate input noise, common-mode rejection, offset across temperature, and RG-resistor tolerance because these characteristics can determine whether the amplifier or converter dominates the measurement error.
推薦
推薦產品摘要
工程參考資料,適用於 INA2126UA — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | INA2126U | INA2126UE4 | INA2126E/250G4 |
|---|---|---|---|---|
| Package | SOIC-16 (D) | SOIC-16 (D) | SOIC-16 (D) | SOIC-16 (D) |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
主要差異化特點
- Two-channel integration in one 16-pin SOIC package (對比INA126UA)
- Same-footprint ordering alternatives retain the core electrical ratings (對比INA2126U)
- Low-power dual-channel precision acquisition (對比INA2126E/250G4)
設計說明
Place the RG gain-setting resistor directly between the designated RG pins and minimize surrounding copper that could increase sensitivity to leakage. Keep input traces short, avoid routing them parallel to switching nodes, and use a continuous ground reference beneath the analog signal path. These practices are particularly important when the expected differential signal is comparable to the 250 µV input offset specification.
Evaluate the complete analog power budget using the 175 µA quiescent current per channel before finalizing a portable design. Supply bypass capacitors should be placed close to the power pins, with the ground connection returning directly to the device. Confirm that the 36 V maximum supply rating is never exceeded during startup, shutdown, or fault conditions, including transient overshoot from the upstream rail.
Do not select gain solely from the 5 V/V to 10,000 V/V headline range. Check input and output common-mode limits, the chosen RG resistor value, reference configuration, and the sensor's full-scale output at the intended supply voltage. An apparently correct gain can still clip or become inaccurate if the output range or input headroom is insufficient.