部品番号: INA2126UA ✓ 生産中INA2126UA 概要
An instrumentation amplifier is a specialized analog amplifier that combines differential input measurement, high input impedance, and accurate gain-setting in one package. Within the signal-chain hierarchy, it sits between sensors or bridge networks and higher-level ADC, control, or monitoring systems. Its differential architecture rejects common-mode interference while preserving the small voltage variations being measured.
The INA2126UA provides two amplifier channels, a 5 V/V to 10,000 V/V programmable gain range, and a gain error of no more than 0.04%. A typical input offset of 250 µV supports precision measurements, while the low 175 µA-per-channel quiescent current suits battery-powered and portable instrumentation. The device operates across an extended temperature range of -40°C to +85°C.
Internally, the INA2126 family uses a two-op-amp instrumentation-amplifier architecture. This structure provides a practical balance between low power, low noise, common-mode rejection, and user-programmable gain. The external resistor between the RG pins establishes the differential gain, allowing one device to serve multiple measurement ranges without changing the analog front end architecture.
Typical uses include bridge-transducer signal conditioning, portable measurement systems, battery-powered diagnostic equipment, industrial sensor interfaces, and low-current precision sensing. Its differential inputs are particularly useful when the source includes substantial common-mode voltage or interference relative to the wanted signal.
Design the layout around the RG resistor, input filtering, and supply grounding. Place the gain-setting resistor close to the device, provide adequate bypassing on both supply rails, and maintain a quiet return path to minimize errors that can dominate microvolt-level measurements. Use the pin-description table in the manufacturer datasheet when assigning PCB tracks and checking exposed alternatives.
This product page combines the manufacturer specifications with practical selection guidance, application analysis, pin-package context, and a parameter-by-parameter comparison. It is intended to help engineers identify whether the INA2126UA fits a low-power precision measurement design and how closely related same-family devices compare.
ドロップイン代替品: INA2126UA — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: INA2126UA (同一形状・フットプリント) — 相違点: Maximum Voltage Gain, Package.
INA2126U
✅ ドロップイン価格はお問い合わせください
データシートを見る →INA2126UE4
✅ ドロップイン📋 参考代替品(カタログ未掲載)
INA2126E/250G4
✅ ドロップイン📋 参考代替品(カタログ未掲載)
INA2126UA 最大定格&電気的特性
| Amplifier Type | Dual precision instrumentation amplifier |
| Number of Channels | 2 channels |
| Maximum Supply Voltage | 36 V |
| Minimum Supply Voltage | 2.7 V |
| Quiescent Current per Channel | 175 µA |
| Input Offset Voltage | 250 µV |
| Minimum Voltage Gain | 5 V/V |
| Maximum Voltage Gain | 10,000 V/V |
| Gain Error | 0.04% maximum |
| Gain-Bandwidth Product | 200 kHz |
| 動作温度範囲 | -40°C to +85°C |
| パッケージ | 16-pin SOIC (D) |
| 実装タイプ | Surface mount |
INA2126UA 16-pin soic (d) ピン配置ガイド
INA2126UA (16-pin soic (d) パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: INA2126UA.
詳細は データシート をご参照ください。
主な用途
INA2126UA の用途: 6 件s: Portable Sensor Measurement, Bridge Transducer Signal Conditioning, Battery-Powered Diagnostic Equipment, Precision Current Sensing, Industrial Sensor Interfaces, Portable Data Acquisition.
Portable Sensor Measurement
The INA2126UA suits portable and battery-operated sensor systems because its 175 µA quiescent current per channel limits the amplifier's contribution to standby demand. Two precision differential channels can measure paired sensors while a 2.7 V minimum supply supports low-energy operation. Its 250 µV offset and programmable gain from 5 V/V to 10,000 V/V permit small sensor outputs to be amplified without requiring a separate low-noise amplifier. The practical trade-off is that output common-mode behavior, reference configuration, and available input headroom must be checked against the selected gain and supply voltage.
おすすめ
Bridge Transducer Signal Conditioning
The INA2126UA is appropriate for resistive bridge outputs because its differential input arrangement reduces common-mode pickup and supports programmable gains up to 10,000 V/V. A 250 µV maximum input offset and 0.04% maximum gain error help preserve measurement accuracy in compact industrial transducers. The external RG resistor makes it practical to match gain to the bridge sensitivity without changing the amplifier package. Engineers should verify excitation voltage, bridge output range, input common-mode limits, and the resistor tolerance needed to meet the final system error budget.
おすすめ
Battery-Powered Diagnostic Equipment
The dual-channel INA2126UA helps reduce the amplifier count in portable diagnostic instruments that acquire two related low-level signals. Its 175 µA-per-channel quiescent current supports a low-power design, while the 36 V maximum supply provides flexibility for higher-voltage diagnostic interfaces. Differential acquisition helps reject common-mode noise present on sensor wiring. Because the offset specification is 250 µV, the actual signal-to-error ratio depends strongly on sensor excitation and output amplitude; low-level channels may require calibration or a more precise gain-setting resistor.
おすすめ
Precision Current Sensing
The INA2126UA can amplify low differential voltages from current-sense elements in battery systems and industrial controllers. Differential inputs are useful when the sense voltage is small relative to its common-mode level, while programmable gain increases the usable ADC range without placing large signals directly on the converter input. The 250 µV offset must be evaluated against the target current resolution and shunt dissipation. Layout should use a compact sense path, avoid copper routes parallel to the low-level inputs, and provide local supply bypassing to prevent conducted noise from obscuring the measurement.
おすすめ
Industrial Sensor Interfaces
The INA2126UA offers a compact way to condition two industrial sensor outputs with high common-mode content. Its 36 V maximum supply accommodates a broader operating environment than low-voltage-only amplifiers, while the two-op-amp architecture maintains low power at 175 µA per channel. Gain can be selected from 5 V/V to 10,000 V/V using the external RG resistor, allowing one architecture to cover several sensor sensitivities. The design must still include input filtering, overvoltage protection, and reference selection appropriate to the expected common-mode and output ranges.
おすすめ
Portable Data Acquisition
The INA2126UA fits two-channel portable data-acquisition systems requiring precision differential inputs and limited operating power. The 2.7 V minimum supply supports compact low-voltage platforms, while 175 µA quiescent current per channel leaves more of the system power budget available to sensors and signal processing. Its 5 V/V to 10,000 V/V gain range covers many low-level transducer outputs. For high-resolution conversion, evaluate input noise, common-mode rejection, offset across temperature, and RG-resistor tolerance because these characteristics can determine whether the amplifier or converter dominates the measurement error.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: INA2126UA — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | INA2126U | INA2126UE4 | INA2126E/250G4 |
|---|---|---|---|---|
| Package | SOIC-16 (D) | SOIC-16 (D) | SOIC-16 (D) | SOIC-16 (D) |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
主な差別化要因
- Two-channel integration in one 16-pin SOIC package (vs INA126UA)
- Same-footprint ordering alternatives retain the core electrical ratings (vs INA2126U)
- Low-power dual-channel precision acquisition (vs INA2126E/250G4)
設計ノート
Place the RG gain-setting resistor directly between the designated RG pins and minimize surrounding copper that could increase sensitivity to leakage. Keep input traces short, avoid routing them parallel to switching nodes, and use a continuous ground reference beneath the analog signal path. These practices are particularly important when the expected differential signal is comparable to the 250 µV input offset specification.
Evaluate the complete analog power budget using the 175 µA quiescent current per channel before finalizing a portable design. Supply bypass capacitors should be placed close to the power pins, with the ground connection returning directly to the device. Confirm that the 36 V maximum supply rating is never exceeded during startup, shutdown, or fault conditions, including transient overshoot from the upstream rail.
Do not select gain solely from the 5 V/V to 10,000 V/V headline range. Check input and output common-mode limits, the chosen RG resistor value, reference configuration, and the sensor's full-scale output at the intended supply voltage. An apparently correct gain can still clip or become inaccurate if the output range or input headroom is insufficient.
コンプライアンス情報
RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals status were not stated in the available product information. Confirm these requirements through the manufacturer product documentation or ordering records.