MPN: LMR342F-GE2 ✓ 啟用中LMR342F-GE2 概覽
A CMOS operational amplifier is a voltage-input, voltage-output amplifier whose internal devices consume very little bias current compared with conventional bipolar input stages. In the signal-chain hierarchy, the LMR342F-GE2 belongs to the operational amplifier family within analog and linear integrated circuits, where low input bias current helps preserve the integrity of high-impedance sensor signals. Its ground-sense architecture is particularly relevant when the input signal is referenced close to ground and the amplifier must support low-voltage operation.
The key engineering benefits are low operating supply current, low input bias current, ground-sense inputs, and full-swing output behavior. The two-circuit configuration allows two independent amplifier channels in one package, reducing board area where a dual amplifier is required. The low-power operating characteristics also help conserve energy in portable systems, while the rail-to-Rail output can improve usable signal range in low-voltage designs. The manufacturer product page identifies sensor amplification, battery-powered electronic equipment, battery monitoring, and audio preamplification as representative use cases.
The LMR342F family is implemented as a CMOS operational amplifier for precision and low-power signal conditioning. The exact electrical limits for the LMR342F-GE2, including supply range, gain-bandwidth product, input offset voltage, input bias current, output swing, and temperature limits, are not fully reproduced in the product excerpts available for this page. Use the manufacturer datasheet for the complete electrical characteristics, test conditions, recommended operating conditions, and pin-description table before finalizing a circuit.
Typical designs include current-sense and battery-monitor front ends, low-voltage sensor signal conditioning, portable audio preamplification, and grounded sensor inputs. Because the amplifier is intended for low-voltage and low-power systems, check supply headroom and output swing against the required signal range. The ground-sense input arrangement can simplify sensing relative to ground, while the full-swing output helps maximize usable output range.
For PCB implementation, place the device close to the protected sensor node and keep the input path short to minimize leakage and contamination sensitivity. Confirm bypass-capacitor requirements and stability guidance in the manufacturer datasheet. Decouple the supply rail locally and keep high-current return paths away from the input reference to reduce ground-induced errors.
This product page combines manufacturer and distributor information with application guidance, selection criteria, package details, and verified drop-in alternatives. It is intended to accelerate engineering evaluation while directing final electrical, thermal, and qualification decisions to the applicable ROHM documentation.
直接替換替代品,適用於 LMR342F-GE2 — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
LMR342FJ-GE2
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
LMR342FV-GE2
✅ 直接替換📋 參考替代品(不在目錄中)
LMR342F-GE2 最大額定值與電氣特性
| Amplifier Type | CMOS operational amplifier |
| Circuit Count | 2 circuits |
| 供應電流 | 32 mA |
| Input Type | Ground-sense input |
| Output Swing | Full swing |
| Rail-to-Rail | Rail-to-Rail |
| 封裝 | 8-SOP |
| 安裝類型 | Surface mount |
LMR342F-GE2 8-sop 腳位配置指南
LMR342F-GE2(8-sop 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: LMR342F-GE2.
請參閱 資料表 以查看完整腳位配置。
典型應用
LMR342F-GE2 適用於 6 應用s: Battery Monitoring, Portable Sensor Signal Conditioning, Voice Audio Preamplifier, Low-Voltage Current Sensing, Industrial Grounded Sensor Front End, Battery-Powered Instrument.
Battery Monitoring
The LMR342F-GE2 fits battery-monitoring front ends because the LMR342F series combines a 32 mA supply-current rating with ground-sense inputs and a full-swing output. Two amplifier channels can be used for signal conditioning or supporting measurements around a low-voltage battery system. Its CMOS input stage and low input bias current are advantageous when the monitored node has high source impedance. The design should still verify the common-mode range, supply limits, offset, and accuracy requirements across the battery's operating range.
推薦
Portable Sensor Signal Conditioning
The LMR342F-GE2 is appropriate for portable sensor conditioning where low operating supply current, low input bias current, and minimal board area are important. Ground-sense input supports sensors whose signals remain close to the lower supply rail, while the full-swing output helps preserve usable amplitude in a low-voltage design. Use the two amplifier channels for input conditioning or gain stages when channel independence is suitable. Verify sensor capacitance, leakage, settling behavior, and the required signal bandwidth before release.
推薦
Voice Audio Preamplifier
The LMR342F-GE2 supports low-power voice audio preamplification as identified by ROHM. Two amplifier channels can process left- and right-channel microphone signals in compact equipment, while low supply current benefits portable operation. The full-swing output can improve available signal range in low-voltage audio circuitry, and ground-sense inputs suit sources referenced close to ground. Confirm output drive, noise, distortion, gain stability, and maximum input amplitude for the intended microphone and load.
推薦
Low-Voltage Current Sensing
The LMR342F-GE2 can condition low-level current-sense signals when the sensing amplifier must operate from a low supply and place minimal load on the source. Its low input bias current helps avoid disturbing high-impedance sensing elements, and ground-sense operation is useful when the measured signal is close to ground. The dual package can support signal conditioning and an auxiliary channel when the system needs both. Validate input offset, common-mode range, slew behavior, and output accuracy against the current-measurement requirements.
推薦
Industrial Grounded Sensor Front End
The LMR342F-GE2 is suited to grounded industrial sensor interfaces where a compact dual amplifier can condition two related signals. The ground-sense architecture is useful for sensors referenced to the lower rail, while low supply current and low input bias current reduce loading in distributed low-power systems. Use short input routes and careful grounding to control offsets and noise. Validate industrial temperature limits, transient protection, common-mode behavior, and isolation requirements directly from the device documentation.
推薦
Battery-Powered Instrument
The LMR342F-GE2 works in battery-powered instrumentation where a dual amplifier can reduce component count and operating current. Ground-sense inputs and a full-swing output help maximize signal utilization when supply voltage is constrained. The LMR342F series is intended for low operating supply voltage, making the device relevant to portable measurement and monitoring systems. Review input bias behavior over the complete temperature range and include startup, supply noise, and output-swing margin in system verification.
推薦
推薦產品摘要
工程參考資料,適用於 LMR342F-GE2 — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | LMR342FJ-GE2 | LMR342FV-GE2 |
|---|---|---|---|
| Package | 8-SOP | 8-SOP | 8-SOP-B listing; package drawing requires confirmation |
| Brand | ROHM Semiconductor | ROHM Semiconductor | ROHM Semiconductor |
主要差異化特點
- Ground-sense input architecture (對比LMR342FJ-GE2)
- Full-swing output for low-voltage signal range (對比LMR342FV-GE2)
- Two-channel integration (對比LMR342FJ-GE2)
設計說明
Place the LMR342F-GE2 close to the sensor source and keep the ground-sense input trace short, clean, and isolated from switching-current paths. Use a local supply bypass capacitor at the device and follow the recommended capacitance and placement from the manufacturer datasheet. Because input bias and offset are important in high-impedance sensing applications, inspect the PCB for contamination, moisture exposure, and leakage paths before applying the final gain.
Verify the complete signal path against the datasheet's input common-mode range, output swing, gain-bandwidth product, slew rate, and stability recommendations. The ground-sense feature helps with signals near the lower rail but does not remove all common-mode restrictions. Include output-load and capacitive-load checks, especially when driving long PCB traces or ADC input networks, and verify settling before sampling slow sensor events.
Do not substitute the LMR342FJ-GE2 or LMR342FV-GE2 solely because their names are similar. The J and V suffixes identify related orderable versions whose package drawings and pin assignments must be checked against the LMR342F-GE2 8-SOP footprint. Also avoid applying the excerpted 2 MHz bandwidth, 1 V/us slew rate, 1 pA bias current, and 250 uV offset values to the target without checking the exact suffix data sheet.
合規資訊
The product excerpts do not provide extractable RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status.