MAX232BASE+T - 5V 2/2 RS-232 Transceiver | Analog Devices
MPN: MAX232BASE+T ✗ 停產MAX232BASE+T 概覽
An RS-232 transceiver is a bridge between a digital controller and a physical serial interface. Within the signal-chain hierarchy, it belongs to the interface-IC class, sits below RS-232 line drivers and receivers, and connects digital logic such as a microcontroller UART to external equipment. The MAX232BASE+T implements the full-duplex portion of that interface with two transmit channels and two receive channels, making it suitable for legacy ports, service consoles, industrial control links, and equipment built around PC-compatible serial communication.
Key characteristics include a 200 kbps maximum data rate, 500 mV receiver hysteresis, a 5 V nominal supply, and 2/2 full-duplex configuration. Its integrated charge pumps eliminate the need for a separate negative rail, while the 16-pin SOIC package supports conventional surface-mount assembly. The MAX232BASE+T is specified for commercial-temperature operation and is intended for equipment where a standard RS-232 port is required rather than higher-voltage or isolated interfaces.
The MAX232 family is based on charge-pump voltage conversion. A small flying capacitor is alternately pumped above and below ground to generate the bipolar voltage swing needed by RS-232 drivers. Receiver inputs include threshold hysteresis, which helps distinguish valid logic states from noise near the transition region. The transmitter converts logic-high and logic-low inputs into the positive and negative voltages defined for RS-232, while the receiver translates those bipolar levels back into logic-compatible signals.
Typical applications include legacy PC serial-port adapters, configuration interfaces for industrial equipment, programming ports for test systems, and control links between older host hardware and embedded controllers. The 200 kbps capability is more than adequate for command-and-response protocols, while the two receive channels can also support hardware flow-control or status signals when the connector pin assignment permits it.
When laying out a board around the MAX232BASE+T, place the charge-pump capacitors and the V+ bypass capacitor close to their designated pins, and route each transceiver line away from switching nodes. Keep the connector-facing nets short, provide a solid ground reference, and observe the RS-232 common-mode limits specified in the manufacturer datasheet. The MAX232 is not an RS-485 transceiver, so it cannot replace an RS-485 physical layer without a different device and termination strategy.
This page combines package and interface details, drop-in replacement guidance, comparison parameters, and practical layout guidance in a single engineering-focused reference for engineers sourcing or maintaining legacy serial-port designs.
直接替換替代品,適用於 MAX232BASE+T — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: MAX232BASE+T (相同外形與佔位) — 差異在於 Package, Interface Standard, Product Type, Number of Receivers, Charge Pump.
MAX232CSE+
✅ 直接替換 ⚠️ 規格未經驗證聯絡詢價
查看資料表 →MAX232ECSE+
✅ 直接替換 ⚠️ 規格未經驗證聯絡詢價
查看資料表 →MAX232ACSE+
✅ 直接替換 ⚠️ 規格未經驗證聯絡詢價
查看資料表 →MAX232EESE+
✅ 直接替換 ⚠️ 規格未經驗證聯絡詢價
查看資料表 →DS14C232CM
✅ 直接替換📋 參考替代品(不在目錄中)
MAX232BASE+T 規格
| Device Type | RS-232 transceiver |
| Number of Drivers | 2 |
| Number of Receivers | 2 |
| Duplex Mode | Full duplex |
| Maximum Data Rate | 200 kbps |
| Nominal Supply Voltage | 5 V |
| Supply Voltage Range | 4.5 V to 5.5 V |
| Receiver Hysteresis | 500 mV |
| 工作溫度範圍 | 0°C to +70°C |
| 封裝 | 16-pin SOIC |
| 安裝類型 | Surface mount |
| Product Description | IC RS-232 DRVR/RCVR COTS |
| Series | MAX232 |
MAX232BASE+T 腳位配置
| 腳位 1 | V+ — Positive supply-voltage connection |
| 腳位 2 | R1OUT — Receiver 1 output |
| 腳位 3 | R2OUT — Receiver 2 output |
| 腳位 4 | R2IN — Receiver 2 input |
| 腳位 5 | R1IN — Receiver 1 input |
| 腳位 6 | V- — Charge-pump negative-voltage node |
| 腳位 7 | T2OUT — Transmitter 2 output |
| 腳位 8 | T2IN — Transmitter 2 input |
| 腳位 9 | T1IN — Transmitter 1 input |
| 腳位 10 | T1OUT — Transmitter 1 output |
| 腳位 11 | V+ — Positive supply-voltage connection |
| 腳位 12 | V+ — Charge-pump positive-voltage connection |
| 腳位 13 | NC — Not connected |
| 腳位 14 | NC — Not connected |
| 腳位 15 | GND — Ground |
| 腳位 16 | V+ — Positive supply-voltage connection |
典型應用
MAX232BASE+T 適用於 6 應用s: Legacy PC Serial Port Interface, Industrial Equipment Control Port, Test and Measurement Service Console, Embedded Configuration Link, Instrumentation Data Port, Legacy Equipment Retrofit.
Legacy PC Serial Port Interface
The MAX232BASE+T fits legacy PC-compatible serial ports because it combines two transmit channels, two receive channels, and a 200 kbps maximum data rate in a 16-pin SOIC package. It converts the UART controller's TTL signals into bipolar RS-232 levels and returns received data as logic-compatible outputs. The integrated charge pump removes the need for a separate negative supply rail, simplifying an adapter or service-console board that requires the classic DE-9 or equivalent connector. Place the charge-pump and bypass capacitors close to the device and route the two driver outputs directly toward the connector while keeping them separated from sensitive logic traces.
推薦
Industrial Equipment Control Port
The MAX232BASE+T is useful for a dedicated control or maintenance port on industrial equipment that communicates through RS-232. Its 2/2 full-duplex arrangement supports one command channel and one response channel, while the 200 kbps rate is comfortably above the throughput of most human-interface protocols. The single 5 V supply simplifies powering from a regulated logic rail, and the integrated charge pump provides the required bipolar drive without an external negative rail. Verify the equipment's connector wiring, common-mode limits, and ground strategy because RS-232 is a single-ended interface and can be sensitive to ground-potential differences between connected systems.
推薦
Test and Measurement Service Console
A MAX232BASE+T-based service port gives test equipment, fixtures, and programming adapters a standard way to accept commands from a host computer. The two receivers can carry serial data and a status or flow-control signal, while the two drivers support bidirectional command traffic. With a maximum rate of 200 kbps and a 4.5 V to 5.5 V operating supply, the device suits conventional UART-based test protocols. For reliable measurements, connect the transceiver ground to the system reference at the appropriate interface point and keep the cable-side nets physically separated from high-current switching paths to reduce coupling into the receiver inputs.
推薦
Embedded Configuration Link
The MAX232BASE+T can provide a wired configuration channel between an embedded controller and a larger system using the familiar RS-232 physical layer. Its two transmit and two receive channels allow bidirectional command traffic plus optional hardware status signaling, and the 200 kbps rate is appropriate for short configuration frames rather than sustained bulk transfer. The device's integrated charge pump allows operation from a 5 V logic supply, reducing board complexity. Confirm the target equipment uses RS-232 bipolar signaling rather than RS-232/TTL or RS-485, and use the manufacturer's charge-pump capacitor values and placement guidance.
推薦
Instrumentation Data Port
The MAX232BASE+T can connect legacy laboratory and industrial instrumentation to a computer or controller through a full-duplex RS-232 port. The 200 kbps data-rate ceiling supports typical measurement-control protocols, while the 500 mV receiver hysteresis helps the receiver reject small disturbances near a logic threshold. Two drivers and two receivers also allow the design to include a remote command input and a separate telemetry output when the connector wiring supports it. Place the transceiver near the DB-style connector, provide a low-impedance ground connection, and keep long cable-side nets away from transformer windings, relays, and switching-regulator nodes.
推薦
Legacy Equipment Retrofit
The MAX232BASE+T is useful when retrofitting newer logic hardware to equipment that exposes only an RS-232 connector. Its 16-pin SOIC package can support board-level replacement of an equivalent legacy transceiver, while the 2/2 configuration preserves both directions of communication. The maximum 200 kbps rate suits firmware-update and diagnostic protocols common on older instruments. Before fitting the part to an existing board, compare the mechanical outline, pin numbering, supply requirements, charge-pump connections, and capacitor values, and verify that the connected equipment uses true bipolar RS-232 rather than a nonstandard TTL-level serial port.
推薦
推薦產品摘要
工程參考資料,適用於 MAX232BASE+T — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | MAX232CSE+ | MAX232ECSE+ | MAX232ACSE+ | MAX232EESE+ | DS14C232CM |
|---|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Texas Instruments |
| Package | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC |
| Transceiver Configuration | 2 drivers / 2 receivers | 2 drivers / 2 receivers | 2 drivers / 2 receivers | 2 drivers / 2 receivers | 2 drivers / 2 receivers | 2 drivers / 2 receivers |
| Product Classification | Commercial temperature | Commercial-temperature family variant | Extended/industrial family variant | Automotive family variant | Extended-temperature family variant | RS-232 transceiver |
主要差異化特點
- Direct MAX232-family interface continuity (對比DS14C232CM)
- Multiple temperature and qualification grades within one footprint family (對比MAX232CSE+)
- Integrated charge-pump operation from a single supply rail (對比MAX232EESE+)
設計說明
Place the charge-pump capacitors, V+ bypass capacitor, and device close to their associated pins. Keep the charge-pump loop compact because its switching current can couple into nearby analog or high-impedance nodes. Use the manufacturer application circuit as the starting point for component values and avoid routing connector-facing RS-232 traces beneath the IC or its capacitor network.
Do not treat every MAX232 suffix as an automatic board-for-board substitute. Confirm the package body width, lead pitch, pin numbering, temperature grade, and charge-pump connections in the candidate datasheet. Also verify that the connected equipment uses bipolar RS-232; a board labeled RS-232 can sometimes carry TTL-level signals that require a different transceiver.
Route the two driver outputs as direct, short traces toward the connector while separating them from receiver inputs and sensitive logic. Provide a low-impedance ground connection to the equipment ground or chassis reference at the interface boundary. If the cable leaves the board, use a protection strategy appropriate for the installation environment and keep unprotected driver traces away from adjacent high-energy circuits.
The MAX232BASE+T supports rates up to 200 kbps, but the usable rate also depends on cable length, connector construction, grounding, and the performance of the connected UART. Leave receiver inputs unloaded beyond the required termination, observe the specified input voltage limits, and avoid long stubs on unused inputs. Validate both logic directions with an oscilloscope during prototype bring-up.
合規資訊
The MAX232BASE+ listing identifies the part as obsolete. No explicit RoHS, REACH, halogen-free, or conflict-minerals declaration was available for the exact ordering code, so these fields remain unknown. AEC-Q100 is not applicable to the listed commercial-temperature MAX232BASE+T grade; use an automotive-qualified family variant when required.