MAX232EING4 - Dual RS-232 Transceiver | Texas Instruments
MPN: MAX232EING4 ✓ 啟用中MAX232EING4 概覽
An RS-232 transceiver is an interface IC that converts low-voltage TTL or CMOS logic signals into RS-232 bipolar levels and converts incoming RS-232 signals back into logic-compatible levels. Within the interface hierarchy, the MAX232 belongs to the RS-232 transceiver class, connects digital logic to serial communication equipment, and forms part of a broader communications interface semiconductor. It is intended for point-to-point RS-232 links rather than multidrop networks.
Key features include two driver and two receiver channels, 5 V operation, ±9 V RS-232 output levels, and ±2 kV ESD protection on the RS-232 pins. The 250 kbps maximum data rate supports common asynchronous serial interfaces when the associated baud rate, cable length, capacitance, and receiver loading permit reliable operation. An industrial temperature option allows operation from -40 °C to +85 °C.
The MAX232 architecture uses charge-pump circuits to generate the positive and negative voltages required by RS-232 transmitters. Each driver converts a logic-high or logic-low input into a corresponding bipolar output, while each receiver uses thresholding to determine the incoming signal state. The integrated voltage conversion avoids a separate negative power supply, although external charge-pump capacitors are required.
Typical applications include industrial serial controllers, data-acquisition equipment, instrumentation interfaces, service equipment, and legacy computer serial ports. The IC can bridge a UART or other CMOS/TTL controller to an RS-232 connector when signal polarity, grounding, and cable requirements are handled correctly. It is especially useful where a 5 V logic system must communicate with older RS-232 equipment.
Designers should place the charge-pump capacitors close to their associated pins and provide a stable, low-impedance bypass path at the supply pins. Long or capacitively loaded cables can reduce the usable baud rate, and the grounded shield or signal ground must be connected according to the RS-232 interface standard. Input and output logic levels should also be checked against the UART voltage thresholds.
This page combines the manufacturer’s electrical characteristics, package information, application guidance, drop-in candidates, and practical circuit considerations to support faster component selection and implementation.
直接替換替代品,適用於 MAX232EING4 — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: MAX232EING4 (相同外形與佔位) — 差異在於 Operating Temperature, Package, Supply Voltage, Data Rate, ESD Protection.
MAX232EPE
✅ 直接替換 ⚠️ 規格未經驗證聯絡詢價
查看資料表 →MAX232EANG4
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
MAX232CPE
✅ 直接替換聯絡詢價
查看資料表 →SP232P
✅ 直接替換📋 參考替代品(不在目錄中)
MAX232EING4 規格
| Device Type | Dual RS-232 transceiver |
| Number of Driver Channels | 2 channels |
| Number of Receiver Channels | 2 channels |
| 供應電壓 | 5 V |
| Maximum Data Rate | 250 kbps |
| RS-232 Output Voltage | ±9 V |
| ESD Protection | ±2 kV |
| 工作溫度 | -40 °C to +85 °C |
| 封裝 | PDIP-16 |
| 腳位數 | 16 pins |
| 安裝類型 | Through-hole |
MAX232EING4 pdip-16 腳位配置指南
MAX232EING4(pdip-16 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: MAX232EING4.
請參閱 資料表 以查看完整腳位配置。
典型應用
MAX232EING4 適用於 6 應用s: Industrial UART Serial Interface, Data Acquisition and Test Equipment, Legacy Computer Serial Port, Instrumentation and Sensor Gateway, Service and Diagnostic Equipment, Industrial Control and Automation.
Industrial UART Serial Interface
The MAX232EING4 fits industrial UART equipment that must translate 5 V CMOS or TTL logic into RS-232 levels. Its two driver and two receiver channels support bidirectional point-to-point serial communication, while the -40 °C to +85 °C rating covers a broad range of factory and process-control environments. The 250 kbps maximum data rate provides margin above common legacy serial baud rates, but cable capacitance and receiver loading must be checked at the intended distance. Integrated charge pumps generate the required bipolar voltage from the 5 V supply, eliminating a separate negative supply rail. Place the manufacturer-specified capacitors close to the charge-pump pins and validate the complete interface across temperature and cable length.
推薦
Data Acquisition and Test Equipment
The MAX232EING4 is appropriate for laboratory and production-test equipment that uses a legacy RS-232 command interface. Two receive channels can monitor commands or status signals, while two driver channels provide the required bipolar output levels. The -40 °C to +85 °C operating range supports equipment intended for industrial laboratories as well as factory-floor use. Because the device provides point-to-point RS-232 signaling rather than multidrop operation, it is best applied to isolated device connections or short bus arrangements validated for the intended loading. Use shielding and a properly referenced signal ground in noisy environments, and confirm the receiver and driver logic thresholds against the host UART.
推薦
Legacy Computer Serial Port
The MAX232EING4 can connect a modern controller to a legacy computer or peripheral with an RS-232 port. The 5 V supply suits contemporary embedded systems, and the two-channel arrangement allows one duplex link plus one additional data direction. The device eliminates the negative power supply normally required by older RS-232 interface circuits because its charge pumps create positive and negative levels internally. At the connector end, confirm the RS-232 signal names, polarity, and ground reference before wiring because DTE and DCE conventions differ. Maintain adequate clearance from high-voltage circuits and use a qualified connector shield. The 250 kbps capability is more than adequate for many legacy serial protocols, subject to cable limitations.
推薦
Instrumentation and Sensor Gateway
The MAX232EING4 suits remote instrumentation and sensor gateways that exchange configuration or status data over RS-232. Its dual channels support receive and transmit functions on one interface, and the industrial temperature range allows operation in uncontrolled equipment rooms and production cells. The bipolar driver levels allow communication with legacy sensors and controllers that lack modern differential interfaces. Designers should treat the RS-232 connection as a point-to-point link unless the complete system has been designed for multidrop behavior. Keep the transceiver away from motors and switching regulators, reference the interface ground correctly, and validate signal integrity with the longest cable and highest baud rate planned for deployment.
推薦
Service and Diagnostic Equipment
The MAX232EING4 is useful in portable service tools and field-diagnostic equipment that connects to older RS-232-controlled subsystems. The device requires only a 5 V rail, reducing system complexity compared with discrete bipolar driver networks. Two transmitters and two receivers allow diagnostic commands to be sent while responses or status lines are monitored. Its -40 °C to +85 °C range supports operation across industrial ambient conditions. The interface still requires careful attention to connector wiring, cable shielding, and logic polarity. Use the manufacturer’s pin and charge-pump capacitor tables directly during layout, and place the interface connector near the transceiver to minimize exposed high-impedance RS-232 traces.
推薦
Industrial Control and Automation
The MAX232EING4 can provide a robust legacy serial port in industrial controllers, remote I/O modules, and automated test systems. The -40 °C to +85 °C operating range and ±2 kV ESD protection make it suitable as an interface component in controlled industrial environments, although additional surge protection may be needed for exposed cables. Its 5 V supply and integrated charge pumps simplify system power design while delivering ±9 V RS-232 output capability. Pair the device with correctly specified logic thresholds and a stable ground reference. Confirm that the controller’s UART supports the selected baud rate and protocol framing, and test the assembled interface with production cable lengths to identify loading or grounding issues early.
推薦
推薦產品摘要
工程參考資料,適用於 MAX232EING4 — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | MAX232EPE | MAX232EANG4 | MAX232CPE | SP232P |
|---|---|---|---|---|---|
| Manufacturer | Texas Instruments | Texas Instruments | Texas Instruments | Analog Devices | Exar |
| Package | PDIP-16 | PDIP-16 | PDIP-16 | PDIP-16 | PDIP-16 |
| Device Type | Dual RS-232 transceiver | Dual RS-232 transceiver | Dual RS-232 transceiver | Dual RS-232 transceiver | Dual RS-232 transceiver |
主要差異化特點
- Industrial-temperature MAX232 option (對比MAX232EPE)
- Single 5 V supply implementation (對比MAX232CPE)
- Four-channel transceiver in a 16-pin PDIP (對比SP232P)
設計說明
Place the charge-pump capacitors directly beside their corresponding MAX232 pins and keep their return paths short. Follow the manufacturer’s recommended capacitance values and PCB footprint because substituted capacitor types or long loops can increase supply ripple or impair charge-pump operation. Add a low-ESR bypass capacitor close to the 5 V supply pins, and route the RS-232 connector and transceiver interface away from clocks, switching regulators, and high-current return paths.
Do not treat RS-232 as a voltage-drop-tolerant multidrop bus. Point-to-point operation is the preferred configuration, and any multidrop design must be evaluated for receiver loading, threshold overlap, cable length, and grounding. Also verify DTE versus DCE signal names and logic polarity at the connector. A pin-compatible-looking IC is not a safe substitution unless its temperature rating, supply voltage, data rate, receiver thresholds, and external capacitor values have all been checked.
Validate the complete interface using the longest production cable, highest planned baud rate, and worst-case transceiver loading. High-capacitance cables can slow RS-232 edges and cause receiver errors even when the nominal data rate is below 250 kbps. Use a properly referenced signal ground, route the cable through a qualified connector shield, and consider additional surge protection for cables that leave an enclosure or connect to externally accessible equipment.
合規資訊
Compliance status was not established from the available manufacturer and distributor pages. Request current quality and environmental documentation for the exact ordering option before production release.