MAX232EING4 - Dual RS-232 Transceiver | Texas Instruments
MPN: MAX232EING4 ✓ NakahandaMAX232EING4 Ulas
An RS-232 transceiver is an interface IC that converts low-voltage TTL or CMOS logic signals into RS-232 bipolar levels and converts incoming RS-232 signals back into logic-compatible levels. Within the interface hierarchy, the MAX232 belongs to the RS-232 transceiver class, connects digital logic to serial communication equipment, and forms part of a broader communications interface semiconductor. It is intended for point-to-point RS-232 links rather than multidrop networks.
Key features include two driver and two receiver channels, 5 V operation, ±9 V RS-232 output levels, and ±2 kV ESD protection on the RS-232 pins. The 250 kbps maximum data rate supports common asynchronous serial interfaces when the associated baud rate, cable length, capacitance, and receiver loading permit reliable operation. An industrial temperature option allows operation from -40 °C to +85 °C.
The MAX232 architecture uses charge-pump circuits to generate the positive and negative voltages required by RS-232 transmitters. Each driver converts a logic-high or logic-low input into a corresponding bipolar output, while each receiver uses thresholding to determine the incoming signal state. The integrated voltage conversion avoids a separate negative power supply, although external charge-pump capacitors are required.
Typical applications include industrial serial controllers, data-acquisition equipment, instrumentation interfaces, service equipment, and legacy computer serial ports. The IC can bridge a UART or other CMOS/TTL controller to an RS-232 connector when signal polarity, grounding, and cable requirements are handled correctly. It is especially useful where a 5 V logic system must communicate with older RS-232 equipment.
Designers should place the charge-pump capacitors close to their associated pins and provide a stable, low-impedance bypass path at the supply pins. Long or capacitively loaded cables can reduce the usable baud rate, and the grounded shield or signal ground must be connected according to the RS-232 interface standard. Input and output logic levels should also be checked against the UART voltage thresholds.
This page combines the manufacturer’s electrical characteristics, package information, application guidance, drop-in candidates, and practical circuit considerations to support faster component selection and implementation.
Mga alternatibo na pwedeng ilagay na MAX232EING4 — parehas na package, pin-to-pin na katugmang. Hindi kasama ang mga bahagi ng iba't-ibang package na nangangailangan ng pagpapaayos ng PCB.
Variante sa Seri na ito
Katulad na modelo sa serye na katugma sa pagpasok MAX232EING4 (parehas na form factor at footprint) — pagkakaiba sa Operating Temperature, Package, Supply Voltage, Data Rate, ESD Protection.
MAX232EPE
✅ Drop-In ⚠️ Mga Talaan Hindi NaiwerikmoMagkontak para sa presyo
Tingnan ang Datasheet →MAX232EANG4
✅ Drop-In ⚠️ Mga Talaan Hindi Naiwerikmo📋 Alternatibo na Reference (hindi sa katalogo)
MAX232CPE
✅ Drop-InMagkontak para sa presyo
Tingnan ang Datasheet →SP232P
✅ Drop-In📋 Alternatibo na Reference (hindi sa katalogo)
MAX232EING4 Mga Spesipikasyon
| Device Type | Dual RS-232 transceiver |
| Number of Driver Channels | 2 channels |
| Number of Receiver Channels | 2 channels |
| Volte ng Pagbibigay | 5 V |
| Maximum Data Rate | 250 kbps |
| RS-232 Output Voltage | ±9 V |
| ESD Protection | ±2 kV |
| Temperature na Operasyon | -40 °C to +85 °C |
| Packhaging | PDIP-16 |
| Bilang ng Pin | 16 pins |
| Uri ng Pagpapasok | Through-hole |
Gabay sa Pin Configuration ng MAX232EING4 pdip-16
Pin configuration para sa MAX232EING4 (pdip-16 package). Ang pagnunumero ng pin, mga function, at connection diagram ay tinukoy sa datasheet ng manufacturer. Sumangguni dito para sa eksaktong footprint at mga alituntunin sa soldering.
Wala ng detalyadong pinout data na magagamit para sa MAX232EING4.
Sumangguni sa datasheet para sa buong pin configuration.
Tipikal na mga Gamit
MAX232EING4 ay nararapat para sa 6 aplikasyons: Industrial UART Serial Interface, Data Acquisition and Test Equipment, Legacy Computer Serial Port, Instrumentation and Sensor Gateway, Service and Diagnostic Equipment, Industrial Control and Automation.
Industrial UART Serial Interface
The MAX232EING4 fits industrial UART equipment that must translate 5 V CMOS or TTL logic into RS-232 levels. Its two driver and two receiver channels support bidirectional point-to-point serial communication, while the -40 °C to +85 °C rating covers a broad range of factory and process-control environments. The 250 kbps maximum data rate provides margin above common legacy serial baud rates, but cable capacitance and receiver loading must be checked at the intended distance. Integrated charge pumps generate the required bipolar voltage from the 5 V supply, eliminating a separate negative supply rail. Place the manufacturer-specified capacitors close to the charge-pump pins and validate the complete interface across temperature and cable length.
Inirekomenda
Data Acquisition and Test Equipment
The MAX232EING4 is appropriate for laboratory and production-test equipment that uses a legacy RS-232 command interface. Two receive channels can monitor commands or status signals, while two driver channels provide the required bipolar output levels. The -40 °C to +85 °C operating range supports equipment intended for industrial laboratories as well as factory-floor use. Because the device provides point-to-point RS-232 signaling rather than multidrop operation, it is best applied to isolated device connections or short bus arrangements validated for the intended loading. Use shielding and a properly referenced signal ground in noisy environments, and confirm the receiver and driver logic thresholds against the host UART.
Inirekomenda
Legacy Computer Serial Port
The MAX232EING4 can connect a modern controller to a legacy computer or peripheral with an RS-232 port. The 5 V supply suits contemporary embedded systems, and the two-channel arrangement allows one duplex link plus one additional data direction. The device eliminates the negative power supply normally required by older RS-232 interface circuits because its charge pumps create positive and negative levels internally. At the connector end, confirm the RS-232 signal names, polarity, and ground reference before wiring because DTE and DCE conventions differ. Maintain adequate clearance from high-voltage circuits and use a qualified connector shield. The 250 kbps capability is more than adequate for many legacy serial protocols, subject to cable limitations.
Inirekomenda
Instrumentation and Sensor Gateway
The MAX232EING4 suits remote instrumentation and sensor gateways that exchange configuration or status data over RS-232. Its dual channels support receive and transmit functions on one interface, and the industrial temperature range allows operation in uncontrolled equipment rooms and production cells. The bipolar driver levels allow communication with legacy sensors and controllers that lack modern differential interfaces. Designers should treat the RS-232 connection as a point-to-point link unless the complete system has been designed for multidrop behavior. Keep the transceiver away from motors and switching regulators, reference the interface ground correctly, and validate signal integrity with the longest cable and highest baud rate planned for deployment.
Inirekomenda
Service and Diagnostic Equipment
The MAX232EING4 is useful in portable service tools and field-diagnostic equipment that connects to older RS-232-controlled subsystems. The device requires only a 5 V rail, reducing system complexity compared with discrete bipolar driver networks. Two transmitters and two receivers allow diagnostic commands to be sent while responses or status lines are monitored. Its -40 °C to +85 °C range supports operation across industrial ambient conditions. The interface still requires careful attention to connector wiring, cable shielding, and logic polarity. Use the manufacturer’s pin and charge-pump capacitor tables directly during layout, and place the interface connector near the transceiver to minimize exposed high-impedance RS-232 traces.
Inirekomenda
Industrial Control and Automation
The MAX232EING4 can provide a robust legacy serial port in industrial controllers, remote I/O modules, and automated test systems. The -40 °C to +85 °C operating range and ±2 kV ESD protection make it suitable as an interface component in controlled industrial environments, although additional surge protection may be needed for exposed cables. Its 5 V supply and integrated charge pumps simplify system power design while delivering ±9 V RS-232 output capability. Pair the device with correctly specified logic thresholds and a stable ground reference. Confirm that the controller’s UART supports the selected baud rate and protocol framing, and test the assembled interface with production cable lengths to identify loading or grounding issues early.
Inirekomenda
Buod ng mga Inirekomendang Produkto
Impormasyon ng Talumpati sa Engineering for MAX232EING4 — ikabit, gabay sa disenyo, at impormasyon ng pagsunod sa kautusan.
Paunawang Hanapin
Ikabit sa Mga Alternatibo
| Parametro | Ito ang Producto | MAX232EPE | MAX232EANG4 | MAX232CPE | SP232P |
|---|---|---|---|---|---|
| Manufacturer | Texas Instruments | Texas Instruments | Texas Instruments | Analog Devices | Exar |
| Package | PDIP-16 | PDIP-16 | PDIP-16 | PDIP-16 | PDIP-16 |
| Device Type | Dual RS-232 transceiver | Dual RS-232 transceiver | Dual RS-232 transceiver | Dual RS-232 transceiver | Dual RS-232 transceiver |
Pangunahing mga Pagkakaiba
- Industrial-temperature MAX232 option (kumpara saMAX232EPE)
- Single 5 V supply implementation (kumpara saMAX232CPE)
- Four-channel transceiver in a 16-pin PDIP (kumpara saSP232P)
Talaan ng Disenyo
Place the charge-pump capacitors directly beside their corresponding MAX232 pins and keep their return paths short. Follow the manufacturer’s recommended capacitance values and PCB footprint because substituted capacitor types or long loops can increase supply ripple or impair charge-pump operation. Add a low-ESR bypass capacitor close to the 5 V supply pins, and route the RS-232 connector and transceiver interface away from clocks, switching regulators, and high-current return paths.
Do not treat RS-232 as a voltage-drop-tolerant multidrop bus. Point-to-point operation is the preferred configuration, and any multidrop design must be evaluated for receiver loading, threshold overlap, cable length, and grounding. Also verify DTE versus DCE signal names and logic polarity at the connector. A pin-compatible-looking IC is not a safe substitution unless its temperature rating, supply voltage, data rate, receiver thresholds, and external capacitor values have all been checked.
Validate the complete interface using the longest production cable, highest planned baud rate, and worst-case transceiver loading. High-capacitance cables can slow RS-232 edges and cause receiver errors even when the nominal data rate is below 250 kbps. Use a properly referenced signal ground, route the cable through a qualified connector shield, and consider additional surge protection for cables that leave an enclosure or connect to externally accessible equipment.
Impormasyon ng Pagsunod sa Kautusan
Compliance status was not established from the available manufacturer and distributor pages. Request current quality and environmental documentation for the exact ordering option before production release.