MAX396CPI+ - 16-Channel 100Ω Analog Multiplexer | Analog Devices
MPN: MAX396CPI+ ✓ 啟用中MAX396CPI+ 概覽
An analog multiplexer is an analog switch that connects one of several input signals to a shared output. A 16:1 device such as the MAX396CPI+ provides one common output and four binary address inputs for selecting among 16 channels. In the broader semiconductor hierarchy, it belongs to the analog switch and multiplexer family within interface integrated circuits. Its low-voltage CMOS implementation supports instrumentation, data acquisition, control, and test systems that route bipolar or single-ended signals.
The MAX396 family provides maximum on-resistance of 100Ω, with resistance matching between switches maintained within 6Ω. The on-resistance remains flat within 10Ω over the specified signal range. Charge injection is limited to 5pC maximum, helping minimize switching transients in measurement paths. According to the manufacturer data sheet, the devices also provide electrostatic-discharge protection greater than 2000V using Method 3015.7.
The device accepts either a single positive supply from +2.7V to +16V or dual supplies from ±2.7V to ±8V while retaining CMOS-compatible logic inputs. Switching timing is specified at 150ns, enabling the mux to serve both moderate-speed acquisition systems and precision measurement circuits. The MAX396 is offered in dual 8-channel configurations, while MAX396CPI+ is the 16-channel, 28-pin PDIP implementation.
Typical uses include multiplexed sensor acquisition, programmable instrumentation, industrial control interfaces, automated test equipment, and low-level signal routing. The 100Ω on-resistance is particularly suitable for high-impedance sensors and amplifier inputs where insertion resistance must remain controlled. The low-voltage supply options also simplify systems using modern low-voltage analog and mixed-signal systems.
PCB design should minimize trace resistance on muxed analog paths and keep switching-node capacitance low. Enable and address transitions should be sequenced so that unwanted channels do not connect during signal acquisition. The 28-pin PDIP footprint is also mechanically straightforward to prototype, although production designs must consider its through-hole package versus smaller surface-mount options.
This page combines the manufacturer's electrical characteristics, packaging information, application guidance, pin-compatible comparisons, and practical layout considerations to support component selection and board-level implementation. It also identifies the operating limits and functional distinctions that matter when choosing between related MAX396 and MAX397 family members.
直接替換替代品,適用於 MAX396CPI+ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
MAX396CPI
✅ 直接替換📋 參考替代品(不在目錄中)
MAX396CPI+ 規格
| Number of Channels | 16 channels |
| Multiplexer Configuration | 16:1 |
| On-Resistance | 100Ω maximum |
| On-Resistance Matching | Within 6Ω between switches |
| On-Resistance Variation | 10Ω maximum over the specified signal range |
| Charge Injection | 5pC maximum |
| Single-Supply Voltage Range | +2.7V to +16V |
| Dual-Supply Voltage Range | ±2.7V to ±8V |
| Switching Time | 150ns |
| Electrostatic-Discharge Protection | Greater than 2000V using Method 3015.7 |
| Logic Compatibility | CMOS-compatible |
| Process Technology | Low-voltage silicon-gate CMOS |
| 工作溫度範圍 | 0°C to +70°C |
| 封裝 | 28-pin PDIP |
| 安裝類型 | Through-hole |
| RoHS 狀態 | Compliant |
| Production Status | Production |
MAX396CPI+ 28-pin pdip 腳位配置指南
MAX396CPI+(28-pin pdip 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: MAX396CPI+.
請參閱 資料表 以查看完整腳位配置。
典型應用
MAX396CPI+ 適用於 6 應用s: Multiplexed Sensor Acquisition, Programmable Instrumentation, Automated Test Equipment, Industrial Control Signal Routing, Precision Data-Acquisition Systems, Battery-Powered Measurement Devices.
Multiplexed Sensor Acquisition
The MAX396CPI+ can connect one of 16 sensors to a shared amplifier or converter input while preserving closely matched channel resistance. Its 100Ω maximum on-resistance is manageable for many high-impedance sensors, and on-resistance matching within 6Ω helps reduce channel-dependent gain variation. With charge injection limited to 5pC maximum, the device supports low-error acquisition systems. The main design consideration is amplifier settling after each address change, particularly when the sensor source impedance and multiplexer capacitance produce a long RC time constant.
Programmable Instrumentation
The MAX396CPI+ is useful in front ends that select among multiple voltage sources, reference inputs, or measurement nodes under digital control. Four address inputs can identify the required one of 16 channels, while the stated 150ns switching time supports prompt routing changes. The low-voltage operation allows the multiplexer to work from +2.7V to +16V or ±2.7V to ±8V. For precision instruments, account for the 5pC maximum charge injection and allow the analog node to settle before sampling.
Automated Test Equipment
The MAX396CPI+ can reduce the number of external connections in a test system by routing 16 inputs to one measurement channel. Its 100Ω maximum on-resistance and 6Ω maximum matching between switches help maintain consistency when different test points are selected. The 28-pin PDIP package also simplifies prototype-board assembly and socket-based maintenance. Production ATE designs should check the device's switching timing, leakage limits, and specified signal-range conditions against the fastest expected test sequence.
Industrial Control Signal Routing
The MAX396CPI+ can route multiple low-level control or feedback signals into a common controller input while keeping the switching network small and deterministic. Operation from +2.7V to +16V is suitable for compact industrial control electronics, and the dual-supply option supports bipolar signals. Because the device provides 100Ω maximum on-resistance, input impedance and injected noise must be considered. Use short analog traces and a suitable input buffer when driving high source impedances.
Precision Data-Acquisition Systems
The MAX396CPI+ supports multiplexed data acquisition by connecting one of 16 analog inputs to a shared converter or amplifier. Its on-resistance variation of 10Ω maximum over the specified signal range helps preserve channel consistency, while 5pC maximum charge injection limits transient error during address transitions. The architecture is well suited to low-voltage precision systems using a +2.7V to +16V supply. Choose acquisition settling time and acquisition timing to accommodate the stated 150ns switching characteristic.
Battery-Powered Measurement Devices
The MAX396CPI+ is suitable for portable measurement equipment because it can operate from a single supply as low as +2.7V. A 16:1 arrangement lets a compact analog front end share one amplifier or converter across multiple sensors without using 16 separate input stages. The 100Ω maximum on-resistance adds little burden to a high-impedance input, although it becomes more significant with lower source impedances. Low-voltage operation and the absence of a switching converter in the signal path also help control system noise.
工程參考資料,適用於 MAX396CPI+ — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | MAX396CPI |
|---|---|---|
| Package | 28-pin PDIP | 28-pin PDIP |
| Brand | Analog Devices | Analog Devices |
| Number of Channels | 16 channels | 16 channels |
| Multiplexer Configuration | 16:1 | 16:1 |
| Maximum On-Resistance | 100Ω | 100Ω |
| Single-Supply Voltage Range | +2.7V to +16V | +2.7V to +16V |
| Dual-Supply Voltage Range | ±2.7V to ±8V | ±2.7V to ±8V |
| Switching Time | 150ns | 150ns |
| Charge Injection | 5pC maximum | 5pC maximum |
主要差異化特點
- Closely matched 16-channel analog routing (對比MAX396CPI)
- Low channel-resistance variation (對比MAX396CPI)
- Flexible single- or dual-supply operation (對比MAX396CPI)
設計說明
Route the common analog output and all 16 channel inputs as short, direct analog traces, and place any input or output filtering capacitors close to the receiving amplifier. The MAX396CPI+ has 100Ω maximum on-resistance, so excessive trace resistance can materially increase the total source impedance. Keep digital address and enable routing away from sensitive analog nodes to reduce capacitive switching coupling.
Allow the analog node to settle after changing the address or enable state. Although the switching time is listed as 150ns, acquisition accuracy also depends on the source impedance, multiplexer capacitance, downstream amplifier bandwidth, and sample-and-hold timing. Account for the 5pC maximum charge injection by measuring acquisition time and error after address transitions rather than sampling immediately after switching.
Do not assume every MAX396 or MAX397 ordering suffix is interchangeable. The MAX396 family supports 16-channel and dual 8-channel configurations, and variants use different package or temperature-ordering codes. Verify the manufacturer pin-description table, supply arrangement, temperature range, and exact MPN before substitution. MAX396CPI is the documented same-package candidate for MAX396CPI+.
合規資訊
RoHS compliance is identified for MAX396CPI. The MAX396 family is listed as production by Analog Devices. Other compliance attributes are not stated and remain unknown.