MCP3561RT-E/NC - 24-Bit 153.6kSPS ADC | Microchip
MPN: MCP3561RT-E/NC ✓ 啟用中MCP3561RT-E/NC 概覽
A delta-sigma ADC is a category of analog-to-digital converter that oversamples its input and uses digital filtering plus noise shaping to convert an analog voltage into a high-resolution digital result. Within the broader signal-conversion hierarchy, it belongs to the data-converter IC family and is commonly positioned between sensor front ends and embedded control systems. The MCP3561RT-E/NC serves this role in industrial instrumentation, sensor measurement, and low-frequency precision acquisition systems.
Key device characteristics include 24-bit nominal resolution, a selectable throughput of up to 153.6 kSPS, a maximum analog input voltage of 3.6 V, and an operating temperature range from -40°C to +125°C. The converter supports SPI communication, which provides a compact serial interface for transferring conversion results to a microcontroller or embedded processor. The device also offers an internal voltage reference and oscillator according to the manufacturer product information for the MCP3561R family.
The delta-sigma conversion architecture favors resolution and noise performance over very high instantaneous throughput, making the device appropriate for sensor signals, process-control channels, and measurements where the signal bandwidth is substantially lower than the maximum conversion rate. The 3 mm by 3 mm UQFN package minimizes PCB area, while the exposed-pad construction supports improved thermal performance when the device operates at high conversion rates or elevated ambient temperatures.
Typical uses include industrial pressure and temperature sensing, laboratory measurement systems, battery and power monitoring, environmental monitoring equipment, and low-speed data acquisition. For analog signal chains, the ADC should be paired with an input amplifier, appropriate anti-alias filtering, and a reference or external precision reference as required by the measurement accuracy target.
PCB layout is critical because the small UQFN footprint leaves limited clearance for analog and digital routing. Place the analog input traces away from SPI lines and switching nodes, use the exposed pad as a thermal and ground connection according to the manufacturer land pattern, and keep input and return paths short to minimize pickup of external noise.
This page combines manufacturer-family specifications, distributor availability information, package and interface details, and application-specific design guidance. It also identifies the closest verified drop-in option and clarifies the electrical and mechanical differences that must be reviewed before substituting an ADC in an existing design.
直接替換替代品,適用於 MCP3561RT-E/NC — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: MCP3561RT-E/NC (相同外形與佔位) — 差異在於 Internal Oscillator, Package.
MCP3561T-E/NC
✅ 直接替換聯絡詢價
查看資料表 →MCP3561RT-E/NC 最大額定值與電氣特性
| 解析度 | 24 bit |
| Maximum Conversion Rate | 153.6 kSPS |
| Input Configuration | 2 single-ended inputs or 1 differential input |
| Conversion Architecture | Delta-sigma |
| Analog Input Count | 2 channels |
| Maximum Analog Input Voltage | 3.6 V |
| Digital Interface | SPI |
| 工作溫度範圍 | -40°C to +125°C |
| Linearity Error | 0.0032% |
| 供應電壓 | 3 V |
| 封裝 | 20-pin UQFN, 3 mm x 3 mm |
| Package Type | UQFN with exposed pad |
| 安裝類型 | Surface mount |
| Shipping Package | Tape and reel |
| Internal Voltage Reference | Yes, integrated in the MCP3561R family |
| Internal Oscillator | Yes, integrated in the MCP3561R family |
| RoHS 狀態 | RoHS compliant |
| 生命週期狀態 | Active |
MCP3561RT-E/NC tape and reel 腳位配置指南
MCP3561RT-E/NC(tape and reel 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: MCP3561RT-E/NC.
請參閱 資料表 以查看完整腳位配置。
典型應用
MCP3561RT-E/NC 適用於 6 應用s: Industrial Pressure and Temperature Sensing, Low-Noise Data Acquisition, Battery-Powered Environmental Monitoring, Process Control and Monitoring, Precision Current and Voltage Measurement, Laboratory and Test Equipment.
Industrial Pressure and Temperature Sensing
The MCP3561RT-E/NC fits industrial sensor front ends that convert low-level pressure, temperature, or level signals into calibrated digital measurements. Its 24-bit resolution preserves small changes in sensor output, while the dual single-ended or differential input arrangement supports both a sensor measurement and a reference or auxiliary channel. The maximum rate of 153.6 kSPS permits faster conversion than many slow-output sensor conditioners require. In a typical circuit, the sensor drives an instrumentation amplifier and an anti-alias filter before entering the ADC. Differential operation can reduce common-mode pickup when the sensor return is available. The 3 mm by 3 mm UQFN package leaves room for protection networks and analog conditioning around a compact sensor board.
推薦
Low-Noise Data Acquisition
The MCP3561RT-E/NC is appropriate for precision data-acquisition modules that prioritize resolution and conversion accuracy over very high sample rates. The 24-bit delta-sigma architecture, 153.6 kSPS maximum throughput, and 0.0032% specified linearity error support laboratory, test, and process-measurement channels. Place a low-noise analog amplifier ahead of the converter and select a digital filter and decimation setting that match the physical bandwidth of the measured signal. The SPI interface simplifies connection to an embedded controller while limiting pin count in compact instrumentation. Because delta-sigma converters trade instantaneous throughput for noise shaping and averaging, software should treat the configured output rate as the effective acquisition rate rather than the converter's maximum conversion capability.
推薦
Battery-Powered Environmental Monitoring
The MCP3561RT-E/NC can serve as the measurement converter in compact battery-powered environmental monitors for temperature, humidity, gas, or light sensing. Its 24-bit resolution allows the system to retain useful information from low-energy sensor outputs, while the integrated reference and oscillator in the MCP3561R family can reduce the number of external precision components. In a portable design, the analog input path should have a high-impedance buffer and leakage-conscious protection components to avoid corrupting the measurement. Duty-cycling the converter and choosing an appropriate decimation and output-data-rate setting helps control average power. The small UQFN footprint also allows the converter, microcontroller, and radio to coexist within a compact sensor enclosure.
推薦
Process Control and Monitoring
The MCP3561RT-E/NC is suited to supervisory and process-control loops where a controller must monitor slow-changing analog variables such as tank level, valve position, or supply conditions. Two single-ended channels can reduce the number of separate converters when the system also requires a reference or status measurement, while differential operation supports bridged sensors and rejects common-mode noise. A programmable digital filter and conversion-rate selection allow the design to trade latency against noise averaging. Place the analog traces away from motor-control and relay-switching nodes to prevent measurement errors. The -40°C to +125°C operating range supports extended-temperature industrial equipment when the external signal-conditioning components satisfy the same environmental limits.
推薦
Precision Current and Voltage Measurement
The MCP3561RT-E/NC can digitize outputs from shunt amplifiers, high-voltage dividers, or precision current-monitoring circuits when the analog input is conditioned to remain within the 3.6 V maximum input rating. The 24-bit conversion resolution is useful for resolving small changes across a wide measurement span, and the differential input capability suits systems where a reference or sense line is available. Input protection, filtering, and settling time around the converter are critical because switching-capacitor front ends may require additional acquisition time at lower output rates. Select the gain, output-data-rate, and digital-filter settings together so the system bandwidth matches the signal of interest without sacrificing unnecessary resolution.
推薦
Laboratory and Test Equipment
The MCP3561RT-E/NC fits bench instruments and automated test systems that measure low-level analog quantities with high resolution. The combination of 24-bit resolution, up to 153.6 kSPS throughput, SPI control, and differential input selection allows one converter to support both measurement and internal reference channels. For laboratory use, an external low-noise reference can be preferable when absolute calibration accuracy is more important than board size. Keep the analog input section physically separated from digital control and relay-driver wiring, and provide solid grounding between the converter, conditioning amplifier, and reference source. The exposed pad should be connected according to the manufacturer land pattern to maintain electrical and thermal performance.
推薦
工程參考資料,適用於 MCP3561RT-E/NC — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | MCP3561T-E/NC |
|---|---|---|
| Package | 20-pin UQFN, 3 mm x 3 mm | 20-pin UQFN, 3 mm x 3 mm |
| Brand | Microchip Technology | Microchip Technology |
| Resolution | 24 bit | 24 bit |
| Maximum Conversion Rate | 153.6 kSPS | 153.6 kSPS |
| Input Configuration | 2 single-ended inputs or 1 differential input | Single-channel ADC configuration |
| Digital Interface | SPI | SPI |
| Conversion Architecture | Delta-sigma | Delta-sigma |
主要差異化特點
- High-resolution conversion in a compact package (對比MCP3561T-E/NC)
- Flexible analog input arrangement (對比MCP3561T-E/NC)
- Extended commercial temperature coverage (對比MCP3561T-E/NC)
設計說明
Route MCP3561RT-E/NC analog inputs as short, continuous traces away from SPI signals, clocks, relay contacts, and switching-regulator nodes. Place the input protection network, anti-alias filter, and any amplifier close to the converter pins. Use the manufacturer land pattern for the 20-pin UQFN and connect the exposed pad according to the recommended analog-ground arrangement; a four-layer board with a continuous ground plane generally simplifies return-current control in this compact footprint.
Do not assume that a 153.6 kSPS converter rate equals the usable signal bandwidth. Output-data-rate, gain, averaging, and digital-filter settings affect both noise and settling behavior. Allow adequate acquisition time for the internal front end, and verify input common-mode and absolute voltage limits against the MCP3561R datasheet. An external precision reference may improve calibration accuracy even though the MCP3561R family includes an onboard reference.
The 3 mm by 3 mm UQFN package relies on its exposed pad for heat spreading. Apply the manufacturer land-pattern dimensions and a low-inductance via arrangement between the pad and the ground plane. For designs operating continuously at high conversion rates or elevated ambient temperature, calculate worst-case converter dissipation and confirm the resulting junction temperature against the device rating.
合規資訊
The distributor product record identifies the MCP3561RT-E/NC as RoHS compliant. No additional certification or material-compliance claims are stated in the product record.