MPX2202A - 200kPa Absolute Pressure Sensor, 4-SIP | NXP
MPN: MPX2202A ⚠ 最後購買機會MPX2202A 概覽
A pressure sensor is a transducer which converts an applied physical pressure into a measurable electrical signal. Within the broader sensor hierarchy, the MPX2202A belongs to the piezoresistive silicon pressure-sensor family, itself a subclass of MEMS sensors under the wider Sensors > Pressure Sensors category. Piezoresistive devices use diffused strain gauges on a silicon diaphragm whose resistance changes with applied pressure; the on-chip signal conditioning and temperature compensation deliver a calibrated, near-linear voltage output without the user needing to add external linearization circuitry.
Key features include 0.4 mV/kPa nominal sensitivity, ±0.25% linearity over the compensated range, on-chip temperature compensation from 0°C to +85°C, and a unibody package that integrates the port, diaphragm, and sensing die. The 4-SIP through-hole form factor is industry-standard for the legacy MPX-series, allowing drop-in compatibility with older MPX2010/MPX2200 designs using the same footprint.
The MPX2202A series (MPX2202, MPXV2202G, MPXM2202) leverages Motorola/Freescale/NXP piezoresistive technology. The silicon die is laser-trimmed for zero-pressure offset and full-scale span, with additional thin-film resistors integrated for active temperature compensation across the industrial 0°C to +85°C range.
Common applications include medical instrumentation (respiratory monitors, blood-pressure cuffs, infusion pumps), industrial process control (HVAC, pneumatic systems), altimeters and barometers, and consumer appliances. The absolute pressure reference (sealed vacuum on the back side of the die) means output is referenced to vacuum rather than ambient, making it ideal for altitude measurement and sealed system monitoring.
When designing with this part, ensure the supply is regulated to 10V nominal for rated performance and apply a low-noise instrumentation amplifier (e.g., INA128, AD620) directly at the SIP pins to avoid noise pickup over the millivolt-level signal path. Use a porous PTFE filter on the pressure port for harsh-media applications.
This page synthesizes distributor pricing from DigiKey, drop-in replacements within the MPX-series footprint, comparison vs the MPX2200A, and practical design notes not found in the standalone manufacturer datasheet.
直接替換替代品,適用於 MPX2202A — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: MPX2202A (相同外形與佔位) — 差異在於 Output Type, Mounting Type, Operating Pressure Range, Linearity, Operating Temperature.
MPX2200A
✅ 直接替換聯絡詢價
查看資料表 →MPXV2202G
✅ 直接替換📋 參考替代品(不在目錄中)
MPXM2202
✅ 直接替換📋 參考替代品(不在目錄中)
MPX2100A
✅ 直接替換聯絡詢價
查看資料表 →MPX2010A
✅ 直接替換📋 參考替代品(不在目錄中)
MPX2202A 最大額定值與電氣特性
| Pressure Type | Absolute |
| Operating Pressure Range | 0 kPa to 200 kPa (0 PSI to 29.01 PSI) |
| 輸出電壓 | 0 mV to 40 mV (typ) |
| Sensitivity | 0.4 mV/kPa nominal |
| 供應電壓 | 10 V typical (16 V max) |
| Linearity | ±0.25% (typ, full scale) |
| Temperature Compensation Range | 0 °C to +85 °C |
| 工作溫度範圍 | -40 °C to +125 °C |
| Port Style | Cell with Body O-Ring |
| 封裝 | 4-SIP Module (Unibody, through-hole) |
| Termination Style | Through-Hole |
| 輸出類型 | Analog Voltage (wheatstone bridge, mV-level) |
| 安裝類型 | Through-Hole (TH) |
| RoHS 狀態 | Compliant (check latest manufacturer PCN) |
| MSL 等級 | Not Applicable (non-IC sensor) |
MPX2202A 腳位配置
| 腳位 1 | Vout+ — Positive Wheatstone bridge output (0-40 mV differential vs Pin 3) |
| 腳位 2 | GND — Ground / substrate reference for the bridge |
| 腳位 3 | Vout- — Negative Wheatstone bridge output |
| 腳位 4 | VS — Supply voltage (10 V typical, 16 V max) |
典型應用
MPX2202A 適用於 6 應用s: Medical Blood Pressure Monitor, Respiratory / Ventilator Pressure Sensing, Industrial Process Control / Pneumatic Systems, Altimeter / Barometer, Infusion Pump Pressure Monitoring, HVAC Pressure Monitoring.
Medical Blood Pressure Monitor
The MPX2202A is widely deployed in electronic sphygmomanometers and patient monitors where it transduces cuff pressure during inflation and deflation cycles. Its 0-200 kPa absolute range covers cuff pressures up to ~150 mmHg (20 kPa) with substantial headroom, while the 0.4 mV/kPa sensitivity provides adequate resolution for systolic/diastolic detection. Per the NXP MPX2202 datasheet, on-chip temperature compensation from 0 °C to +85 °C eliminates the need for software temperature correction across the clinical environment.
推薦
Respiratory / Ventilator Pressure Sensing
In CPAP, BiPAP, and respiratory-care equipment, the MPX2202A monitors airway and circuit pressure to ensure safe patient ventilation. The absolute pressure reference allows accurate measurement of pressure delivered to the patient regardless of atmospheric variation, important for altitude-compensated ventilator designs. With its 0-200 kPa range and millivolt-level ratiometric output, the MPX2202A integrates with isolation amplifiers (e.g., ISO124) to meet IEC 60601-1 patient-safety requirements.
推薦
Industrial Process Control / Pneumatic Systems
Factory pneumatic systems, hydraulic actuators, and process-control loops use the MPX2202A to monitor line pressure from 0-200 kPa with 0.25% linearity. The unibody 4-SIP package installs directly into pneumatic manifolds via the body O-ring port, providing a leak-tight seal at the pressure interface. The ratiometric 0-40 mV signal at 10 V supply feeds directly into 4-20 mA loop converters for industrial transmitter designs; its on-chip temperature compensation holds calibration across factory floor ambient swings.
推薦
Altimeter / Barometer
The MPX2202A's absolute pressure reference (sealed vacuum on the back side) makes it ideal for altitude measurement and barometric applications. At sea level (101.325 kPa), output is approximately 40 mV; at 3000 m (~70 kPa), output drops to ~28 mV, yielding ~4 mV per 1000 ft altitude - easily resolved by a 12-bit ADC. According to the NXP datasheet, the absolute reference is preferred for altimeters because ambient barometric pressure is the measurand, not a differential quantity.
推薦
Infusion Pump Pressure Monitoring
Volumetric and syringe infusion pumps use the MPX2202A to detect upstream occlusion by monitoring the pressure rise in the IV line. The 200 kPa range covers typical occlusion alarm thresholds (~50 kPa) with substantial margin for high-pressure injectors. Per the NXP datasheet, the device's biocompatible media compatibility (when used with appropriate tubing and O-ring interface) and stable ratiometric output enable reliable alarm triggering. Low noise output prevents false occlusion alarms during gravity-feed flow.
推薦
HVAC Pressure Monitoring
Building automation systems use the MPX2202A for duct static-pressure measurement, filter-status monitoring, and variable-air-volume (VAV) box feedback. The 0-200 kPa range covers typical duct static pressures of 0-1.5 kPa with adequate resolution for filter-loading detection. Its unibody package with O-ring port simplifies mounting on sheet-metal ductwork via a compression fitting. The on-chip temperature compensation handles the wide ambient swing in mechanical rooms (0 °C to +50 °C) without software correction.
推薦
推薦產品摘要
工程參考資料,適用於 MPX2202A — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | MPX2200A | MPXV2202G | MPXM2202 | MPX2100A | MPX2200D |
|---|---|---|---|---|---|---|
| Brand | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors |
| Package | 4-SIP Unibody Module (Through-Hole) | 4-SIP Unibody Module (same) | SOP-8 SMD with gauge port (different footprint) | Small SMD package (different footprint) | 4-SIP Unibody Module (same) | 4-SIP Unibody Module (same) |
| Pressure Type | Absolute | Absolute | Gauge | Absolute | Absolute | Differential |
| Operating Pressure Range | 0 to 200 kPa | 0 to 200 kPa | 0 to 200 kPa | 0 to 200 kPa | 0 to 100 kPa | 0 to 200 kPa (differential) |
| Output Voltage | 0 to 40 mV | 0 to 40 mV | 0 to 40 mV | 0 to 40 mV | 0 to 20 mV | 0 to 40 mV |
| Sensitivity | 0.4 mV/kPa | 0.4 mV/kPa | 0.4 mV/kPa | 0.4 mV/kPa | 0.2 mV/kPa | 0.4 mV/kPa |
| Supply Voltage | 10 V typ / 16 V max | 10 V typ / 16 V max | 10 V typ / 16 V max | 10 V typ / 16 V max | 10 V typ / 16 V max | 10 V typ / 16 V max |
| Port Style | Cell with Body O-Ring | Cell with Body O-Ring | Gauge horizontal port | Small SMD port | Cell with Body O-Ring | Dual port differential |
| Lifecycle Status | Last-Time-Buy | Last-Time-Buy | Active (verify) | Active (verify) | Last-Time-Buy | Last-Time-Buy |
主要差異化特點
- On-chip temperature compensation across 0 °C to +85 °C (對比MPX2200A)
- Unibody 4-SIP package with axial port and body O-ring (對比MPXV2202G (SOP-8 SMD gauge port))
- Absolute pressure reference sealed to vacuum (對比MPX2200D (differential))
設計說明
The MPX2202A produces a low-level differential mV signal (0-40 mV) that is highly susceptible to EMI and ground loops. Place the instrumentation amplifier (e.g., INA128, AD620) within 5 cm of the SIP pins, use twisted-pair wiring or guard traces, and keep the amplifier's high-impedance input traces away from switching converters. Add 100 nF ceramic bypass capacitors at VS (Pin 3) and GND (Pin 2) directly at the sensor pins. Per TI INA128 datasheet, input bias current return paths must be provided; do not leave either Vout- or Vout+ floating.
Do not exceed 16 V on Pin 3 (VS) - the on-chip temperature compensation and bridge resistors are designed for 10 V nominal operation and overvoltage degrades linearity and accelerates drift. Ensure the O-ring at the pressure port is properly seated; the unibody package relies on the O-ring for both pressure sealing and mechanical strain relief. For harsh chemicals or medical fluids, verify media compatibility - the standard gel-coat is rated for non-corrosive media only. Allow at least 60 seconds warm-up after power-on for the bridge to stabilize.
Estimated: For a through-hole 4-SIP socket or PCB pad layout, use 1.0 mm diameter plated through-holes on a 2.54 mm (0.1 inch) row pitch matching the SIP lead spacing. Provide a copper pour on the opposite layer connected to GND to act as a guard/ground plane for the mV-level signal traces. Estimated input power: 10 V * 6 mA typical = 60 mW dissipation; no heatsinking required. For IEC 60601-1 patient-leakage compliance, isolate the sensor amplifier section from mains with an isolation barrier (e.g., ISO124).
Supply the MPX2202A from a low-noise, regulated 10 V rail; a switching DC-DC converter without adequate filtering will inject noise into the mV-level output. According to typical application circuits in the NXP datasheet, an RC low-pass filter (10 ohm + 10 uF) at Pin 3 (VS) reduces supply noise by 40 dB. For battery-powered designs, an LT3042 LDO or equivalent providing <2 mVrms noise is sufficient. Total supply current at 10 V is approximately 6 mA typical.
合規資訊
RoHS and REACH compliant per NXP product page; not AEC-Q100 qualified (consumer/industrial pressure sensor, not automotive); halogen-free status not explicitly stated in available data - confirm with NXP. For medical end-use, IEC 60601-1 compliance is a system-level requirement, not a sensor-level qualification.