OPA130PA - 1MHz Low-Power FET-Input Op Amp | Texas Instruments
MPN: OPA130PA ✓ 啟用中OPA130PA 概覽
A FET-input operational amplifier is an op amp whose input stage uses field-effect transistors rather than bipolar input transistors. The OPA130PA combines the very high input impedance and low bias current of a FET input stage with the precision dc characteristics expected from the OPAx130 family. In signal-chain terms, the device belongs to the operational-amplifier family and ultimately to the broader analog integrated-circuit and semiconductor categories.
Key specifications include a maximum input offset voltage of 1 mV, minimum open-loop gain of 120 dB, minimum common-mode rejection of 90 dB, and a maximum input bias current of 20 pA. Its 1 MHz bandwidth makes it suitable for precision buffers, instrumentation, sensor interfaces, and moderate-frequency signal conditioning. The 530 uA quiescent current supports portable, battery-powered, and high-impedance instrumentation systems where amplifier power consumption is important.
The OPA130PA uses a precision internal design that supports low-offset operation and high open-loop gain. Its FET input stage is particularly valuable when the source impedance is high, because the amplifier draws minimal input current and therefore minimizes source-loading errors. The device is also suitable for transimpedance-style front ends where the signal source may be a sensor with picoamp-level leakage.
Typical uses include low-level sensor amplification, current measurement, bridge-amplifier interfaces, audio and communications buffers, laboratory instrumentation, and portable measurement equipment. The wide supply range supports both single-supply systems and traditional ±15 V laboratory rails. Because the OPA130PA is a general-purpose precision amplifier rather than a high-speed comparator or rail-to-rail device, applications requiring operation close to the supply rails or substantially higher bandwidth should use a different amplifier family.
For PCB design, treat the PDIP package as a through-hole component and provide adequate clearance around the leads. Decoupling capacitors should be placed close to the supply pins, and input and output routing should avoid proximity to switching nodes. Confirm the input common-mode range and output swing against the actual supply voltage before finalizing the bias point.
This page combines the manufacturer product information, distributor records, cross-reference results, application guidance, and design notes into one engineering-focused reference for sourcing and circuit implementation.
直接替換替代品,適用於 OPA130PA — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: OPA130PA (相同外形與佔位) — 差異在於 Input Bias Current, Package, Amplifier Type, Open-Loop Gain, Quiescent Current.
OPA134PA
✅ 直接替換聯絡詢價
查看資料表 →OPA130PA 最大額定值與電氣特性
| Amplifier Type | Single operational amplifier |
| Input Topology | FET input |
| Gain-Bandwidth Product | 1 MHz |
| Input Bias Current | 20 pA maximum |
| 靜態電流 | 530 uA typical per amplifier |
| Input Offset Voltage | 1 mV maximum |
| Open-Loop Gain | 120 dB minimum |
| Common-Mode Rejection Ratio | 90 dB minimum |
| Supply Voltage Range | 4.5 V to 36 V |
| Total Supply Voltage Range | 4.5 V to 36 V |
| Dual-Supply Operating Range | +/-18 V |
| 封裝 | 8-pin PDIP, 0.300 inch body width |
| 安裝類型 | Through-hole |
| 腳位數 | 8 |
| Low Offset Voltage | 1 mV maximum |
| High Open-Loop Gain | 120 dB minimum |
| Excellent Bandwidth | 1 MHz |
| RoHS 狀態 | Compliant |
| AEC-Q100 Qualification | Not applicable |
OPA130PA 腳位配置
| 腳位 1 | NC — Not connected |
| 腳位 2 | IN- — Inverting input |
| 腳位 3 | IN+ — Non-inverting input |
| 腳位 4 | V- — Negative supply connection |
| 腳位 5 | NC — Not connected |
| 腳位 6 | OUT — Amplifier output |
| 腳位 7 | V+ — Positive supply connection |
| 腳位 8 | NC — Not connected |
典型應用
OPA130PA 適用於 6 應用s: High-Impedance Sensor Amplifier, Portable Battery-Powered Instrumentation, Transimpedance Front End, Precision Current Measurement, Laboratory Buffer and Active Probe, Audio and Communications Buffering.
High-Impedance Sensor Amplifier
The OPA130PA fits high-impedance sensor front ends because its FET input stage draws no more than 20 pA of input bias current. That low loading preserves the voltage generated by piezoelectric, electrochemical, or very-high-value resistive sources. With a 1 MHz gain-bandwidth product and 120 dB minimum open-loop gain, the amplifier can provide useful closed-loop gain while retaining low-offset behavior. Place the amplifier close to the sensor connection, keep input traces short, and shield them from switching nodes.
推薦
Portable Battery-Powered Instrumentation
The OPA130PA is suited to portable instruments because its typical quiescent current is only 530 uA per amplifier. Combined with a 4.5 V minimum total supply and 20 pA maximum input bias current, it supports low-power measurement channels with sensitive sources. The precision offset specification of 1 mV maximum helps preserve small-signal accuracy, while the 1 MHz bandwidth supports sensor signals below the amplifier's full capability. Calculate the complete system budget, including gain resistors and external filtering.
推薦
Transimpedance Front End
The OPA130PA can serve as the transimpedance amplifier in optical, photodiode, or photocurrent measurement circuits because its maximum input bias current is 20 pA. The low bias current reduces error current relative to the measured photocurrent and minimizes voltage error across a high-value feedback resistor. Its 90 dB minimum common-mode rejection ratio also helps suppress supply-related disturbances. Use the manufacturer stability and compensation guidance when selecting the feedback resistor and stray-capacitance allowance.
推薦
Precision Current Measurement
OPA130PA is appropriate for amplifying the voltage produced by a current shunt or current-sense element in precision industrial control systems. Its 1 mV maximum input offset voltage limits the error added at the input, and the 120 dB minimum open-loop gain supports accurate closed-loop operation. The wide 4.5 V to 36 V supply range also permits ±15 V laboratory instrumentation. For best results, keep the shunt connection compact and evaluate the amplifier's offset and bias-current errors against the required measurement resolution.
推薦
Laboratory Buffer and Active Probe
OPA130PA works well as a laboratory buffer or active probe driver when the source impedance is high and signal loading must remain small. The 20 pA maximum input bias current is more suitable for this role than the tens-of-nanoampere input currents common in bipolar-input op amps. A 1 MHz bandwidth supports moderate-frequency waveforms, and ±18 V dual-supply operation simplifies compatibility with legacy bench instruments. Use short, guarded input traces and verify the output swing before driving the intended load.
推薦
Audio and Communications Buffering
OPA130PA is suitable for low-level audio and communications signal buffering because it combines a 1 MHz gain-bandwidth product with low input bias current and low quiescent current. It can isolate a high-impedance source from a downstream load while maintaining acceptable signal integrity at moderate frequencies. The 36 V maximum total supply permits operation from common laboratory rails and higher industrial bias arrangements. Avoid using it for high-frequency video or RF stages because its 1 MHz bandwidth is the limiting parameter.
推薦
工程參考資料,適用於 OPA130PA — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | OPA134PA | OPA137PA | OPA130UA |
|---|---|---|---|---|
| Package | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP ordering variant |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Amplifier Configuration | Single | Single | Single | Single |
| Gain-Bandwidth Product | 1 MHz | 8 MHz | 5.5 MHz | 1 MHz |
| Input Bias Current | 20 pA maximum | 5 pA typical | 100 pA typical | 20 pA maximum |
| Input Offset Voltage | 1 mV maximum | 0.5 mV maximum | 0.5 mV maximum | 1 mV maximum |
| Supply Voltage Range | 4.5 V to 36 V | 2.5 V to 36 V | 4.5 V to 36 V | 4.5 V to 36 V |
主要差異化特點
- Lower power consumption than the precision alternatives (對比OPA137PA)
- High input impedance for sensor interfaces (對比OPA134PA)
- Direct same-family ordering alternative (對比OPA130UA)
設計說明
Place supply-decoupling capacitors close to the V+ and V- pins and connect the amplifier ground reference to the quiet analog return path. Keep the inverting and non-inverting inputs short and separate from switching-node copper. Because the OPA130PA uses a PDIP package, provide adequate lead-bend clearance and avoid applying mechanical stress to the pins during socket soldering.
Do not assume the 4.5 V to 36 V supply rating permits operation arbitrarily close to a rail. Check the specified input common-mode range and output swing against the intended signal and load. Also account for offset voltage, bias-current error, and resistor thermal drift when specifying the smallest measurable input. A higher-bandwidth amplifier may be required if the signal contains substantial content above 1 MHz.
For high-impedance sources, minimize PCB leakage and contamination around the input nodes, keep the input path short, and use a protective guard structure where practical. The 20 pA maximum input bias current is low, but board contamination can still create a comparable leakage error. Confirm stability with the intended source impedance, feedback network, and load capacitance using the manufacturer guidance.
合規資訊
A distributor product listing identifies the OPA130PA as RoHS compliant. No AEC-Q100 automotive qualification is listed for this general-purpose amplifier.