OPA606KP - 13MHz DIFET Op Amp | Texas Instruments
MPN: OPA606KP ✓ 啟用中OPA606KP 概覽
An operational amplifier is an analog building block that amplifies the voltage difference between its differential inputs while using negative feedback to set the closed-loop gain. The OPA606 belongs to the instrumentation-amplifier and general-purpose op-amp hierarchy: it combines high open-loop gain, wide frequency response, low offset voltage, low bias current, and fast slew performance in one precision analog IC.
The OPA606KP uses Texas Instruments’ Difet operational-amplifier technology to achieve a 13 MHz gain-bandwidth product and 30 V/µs slew rate. Its input bias current is 8 pA, while input offset voltage is 78 dB lower than a typical mV-level bipolar amplifier, with the manufacturer describing the offset-voltage characterization in dB. The device includes a single amplifier, supports operation from 10 V to 36 V total supply voltage, and is supplied in a through-hole 8-PDIP package.
Because its 13 MHz bandwidth and 30 V/µs slew rate can reproduce high-frequency signal transitions, the OPA606KP is well suited to instrumentation preamplifiers, active filters, wideband buffers, laboratory test circuits, and signal converters. Its 8 pA input bias current also helps preserve accuracy when the source presents very high impedance.
The 8-pin DIP construction favors legacy instrumentation, educational, prototype, and industrial control systems where through-hole assembly and socketed maintenance are useful. Its wide supply range also allows operation from conventional ±5 V and ±15 V laboratory rails, although input and output voltage limits must be respected during startup and saturation.
For reliable operation, place a short feedback path close to the amplifier, use low-leakage nodes around the high-impedance input, and decouple each supply rail near the package. Check the stable-gain configuration in the manufacturer datasheet, especially when driving capacitive loads or operating at gain levels where the amplifier’s frequency-response characteristics become critical.
This page combines the OPA606KP’s manufacturer characteristics with package-specific selection guidance, verified drop-in alternatives, and practical design notes for high-impedance and wideband analog circuits.
直接替換替代品,適用於 OPA606KP — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
OPA606KP-3
✅ 直接替換📋 參考替代品(不在目錄中)
OPA606KP 最大額定值與電氣特性
| Amplifier Type | Single operational amplifier |
| Gain-Bandwidth Product | 13 MHz |
| Slew Rate | 30 V/µs |
| Supply Voltage Range | ±5 V to ±18 V |
| Total Supply Voltage Range | 10 V to 36 V |
| Input Bias Current | 8 pA |
| Input Offset Voltage | 78 dB characterization |
| 最大輸出電流 | 10 mA per channel |
| Number of Amplifiers | 1 |
| 腳位數 | 8 |
| Package Type | 8-PDIP |
| Package Body Width | 0.300 in (7.62 mm) |
| Technology | DIFET |
| 安裝類型 | Through-hole |
OPA606KP 0.300 in (7.62 mm) 腳位配置指南
OPA606KP(0.300 in (7.62 mm) 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: OPA606KP.
請參閱 資料表 以查看完整腳位配置。
典型應用
OPA606KP 適用於 6 應用s: Precision Instrumentation Preamp, Wideband Active Filter, Laboratory Buffer, Test and Measurement Signal Conditioning, Audio and Communication Interface, Data Acquisition Front End.
Precision Instrumentation Preamp
The OPA606KP is appropriate for the input stage of a laboratory or process instrumentation circuit because its 8 pA input bias current creates very little error across a high-impedance sensor. The 13 MHz gain-bandwidth product also allows the amplifier to process signals beyond the bandwidth of many general-purpose precision op amps. Place the device close to the sensor input, use guarded high-impedance nodes, and keep feedback components compact to reduce parasitic capacitance and leakage.
推薦
Wideband Active Filter
OPA606KP can implement a wideband active-filter section when signal bandwidth matters and a 30 V/µs slew rate is required for clean large-signal transitions. Its 13 MHz gain-bandwidth product provides the loop bandwidth needed for practical low-pass, high-pass, or band-pass networks operating well above audio frequencies. Component tolerances and op-amp gain-bandwidth behavior determine the achieved response, so the filter should be simulated and stability-checked for the selected noise-gain curve.
推薦
Laboratory Buffer
OPA606KP is useful as a wideband unity-gain buffer for buffering oscillators, sensor outputs, and test fixtures. The 30 V/µs slew rate preserves large-amplitude, high-frequency signal edges better than a slow precision amplifier, while the 8 pA bias current limits loading of high-impedance sources. Confirm unity-gain stability and capacitive-load behavior in the manufacturer datasheet, and connect the feedback directly to the output to minimize parasitic feedback paths.
推薦
Test and Measurement Signal Conditioning
OPA606KP suits test and measurement front ends that must condition moderate-frequency signals without introducing excessive slew-rate distortion. Its 13 MHz gain-bandwidth product and 30 V/µs slew rate support waveform capture, gain stages, and impedance-conversion circuits around sensors and transducers. For high-precision DC measurements, evaluate input offset voltage and drift at the intended temperature; for high-source-impedance sources, pay particular attention to the 8 pA input bias current.
推薦
Audio and Communication Interface
OPA606KP can be used in line-level audio or communications interfaces that benefit from more bandwidth than conventional general-purpose op amps provide. The 13 MHz gain-bandwidth product and 30 V/µs slew rate provide margin for higher-frequency signal components and reduce slew-induced distortion. The single amplifier is suitable for an active filter, gain cell, or line driver, but output-current capability, load impedance, and output-voltage swing should be checked against the required channel load.
推薦
Data Acquisition Front End
OPA606KP works as a gain and drive stage ahead of an ADC when the acquisition path requires more bandwidth than a conventional precision amplifier provides. Its 30 V/µs slew rate helps maintain large-signal integrity, and its 8 pA bias current reduces input-stage error for high-impedance sources. The design must account for ADC input capacitance, settling time, and the amplifier’s stability with capacitive loads, using the manufacturer datasheet’s recommended values and typical application circuits.
推薦
推薦產品摘要
工程參考資料,適用於 OPA606KP — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | OPA606KP-3 |
|---|---|---|
| Brand | Texas Instruments | Texas Instruments |
| Package | 8-PDIP | 8-PDIP |
| Amplifier Type | Single operational amplifier | Single operational amplifier |
主要差異化特點
- Wide-bandwidth performance in a legacy DIP package (對比OPA606KP-3)
- Low input bias current supports high-impedance sources (對比OPA606KM)
- Higher slew rate preserves large-signal transitions (對比OPA606KM)
設計說明
Keep the op-amp input, feedback, and gain-setting networks compact. The 8 pA input bias current of the OPA606KP can support high-impedance sources, but PCB contamination and leakage across a sensitive input may still dominate the total error. Use a guarded or well-cleaned input area, avoid long exposed traces, and connect the feedback return directly to the amplifier output to minimize parasitic coupling.
The OPA606KP supports ±5 V to ±18 V operation, giving a 10 V to 36 V total supply range. Decouple each supply rail close to the package with a suitable high-frequency bypass capacitor, and keep the power and ground return paths short. Verify actual input and output swing because rail-adjacent signals, startup behavior, and overload conditions can reduce the usable output range even when the total supply voltage is within specification.
Do not substitute an eight-pin amplifier solely by package count. OPA606KM has slightly different published bandwidth and slew-rate values, and the cross-reference information does not establish that its footprint and pinout match the installed 8-PDIP. Before replacement, compare the power pins, offset-null pins, input pins, output, feedback topology, supply range, stability, and operating temperature requirements from the manufacturer datasheet.
合規資訊
Compliance status was not established by the cited component pages. AEC-Q100 is marked not applicable because OPA606KP is a general-purpose analog amplifier rather than an automotive-qualified device.