INA129P 概述

The Texas Instruments INA129P is a precision, low-power instrumentation amplifier with one amplifier circuit, 120 dB minimum common-mode rejection, 50 uV maximum offset voltage, and a 200 kHz bandwidth at gain 100, packaged in an 8-pin PDIP. It accepts signals within the low-noise, low-offset instrumentation-amplifier class and supports wide bipolar supply operation up to ±18 V.

An instrumentation amplifier is a specialized analog amplifier that measures a small differential voltage while rejecting common-mode interference. Its internal three-op-amp architecture supports high input impedance and adjustable gain, making it useful when a sensor produces a low-level signal and the surrounding wiring introduces substantial common-mode voltage. The INA129P is therefore positioned between a general-purpose operational amplifier and a more specialized precision measurement amplifier.

Key features include 50 uV maximum offset voltage, 0.5 uV/°C maximum offset drift, 5 nA maximum input bias current, and input protection to ±40 V. The single external gain-setting resistor provides gain adjustment from 1 through 10,000 according to the manufacturer family information, while current-feedback input circuitry maintains useful bandwidth at higher gain. The stated 200 kHz bandwidth at gain 100 makes the device suitable for sensor and instrumentation signal paths rather than only static measurement.

The INA129P uses a low-power instrumentation-amplifier architecture intended for precision measurement systems. Its common-mode rejection helps suppress voltage common to both inputs, and the low offset and drift reduce measurement error in bridge, current, and industrial sensor applications. The ±18 V supply capability provides flexibility for dual-supply analog systems, while the 8-pin PDIP format supports through-hole assembly and prototyping.

Typical uses include bridge and load-cell signal conditioning, industrial process measurement, biomedical instrumentation, current sensing, and precision test equipment. The ±40 V input protection specification is useful when the amplifier is positioned near sensor wiring, although system-level protection and operating conditions still require engineering review.

The principal design consideration is ensuring that the external gain resistor, supply bypassing, input protection, and common-mode range are matched to the sensor. For a new design, verify the exact INA129P pinout and electrical limits against the current Texas Instruments datasheet before layout release.

This page consolidates verified distributor snippets, manufacturer family information, package details, and application guidance, while distinguishing documented specifications from information that requires design-team verification.

直接替换替代料: INA129P ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: INA129P (相同外形与封装尺寸) ——差异在于 Product Type, Package, Gain Range, Mounting Type, Architecture.

Analog Devices
Product Type: Low-cost, low-power, high-accuracy instrumentation amplifier
Package: 8-lead PDIP
对比 INA129P →
Texas Instruments
Product Type: Precision instrumentation amplifier
Architecture: Three-op-amp instrumentation amplifier
对比 INA129P →
Texas Instruments
Product Type: Precision instrumentation amplifier
Package: 8-pin PDIP
Architecture: Three-op-amp instrumentation amplifier
对比 INA129P →
Texas Instruments
Product Type: Instrumentation Amplifier (INA)
Gain Range: 1 V/V to 10,000 V/V
Mounting Type: Surface Mount

快速对比工具——选择替代料号进行并排对比:

INA129PA

✅ 直接替换
📦 PDIP-8
Same INA129 family and PDIP-8 package is indicated by the supplied comparison results, but the supplied data does not quantify an exact pin or electrical difference; the evidence supports 90% parameter proximity.

📋 参考替代料(不在目录中)

INA129U/2K5

✅ 直接替换
Texas Instruments
📦 PDIP-8
Texas Instruments · Instrumentation Amplifier (INA) · INA12x (INA128 / INA129) · 1 · 3-Op-Amp, current-feedback input · 8-pin SOIC (SO-8) · Surface Mount · ±2.25 V to ±18 V

✓ 有现货

$2.99 / 个

查看数据手册 →

INA128PA

✅ 直接替换
Texas Instruments
📦 PDIP-8
Precision instrumentation amplifier · Three-op-amp instrumentation amplifier · 1 circuit · 8-pin PDIP · 130 dB · 120 dB · 700 µA · 50 µV

✓ 有现货

联系询价

查看数据手册 →

AD620BNZ

✅ 直接替换
📦 PDIP-8
GlobalSpec lists AD620BNZ as an alternative, and the supplied comparison identifies an 8-pin through-hole instrumentation-amplifier format, but exact pin-level and electrical equivalence is not proven; 70% proximity is the drop-in floor.

📋 参考替代料(不在目录中)

AD620ANZ

✅ 直接替换
Analog Devices
📦 PDIP-8
Low-cost, low-power, high-accuracy instrumentation amplifier · 1 channel · 1 to 10,000 · One external resistor · 1 MHz · 1.3 mA · 2 nA

✓ 有现货

$6.2 / 个

查看数据手册 →

INA129P 最大额定值与电气特性

Product Type Precision low-power instrumentation amplifier
Amplifier Circuit Count 1
封装 8-pin plastic DIP (PDIP)
安装类型 Through-hole
Maximum Offset Voltage 50 uV
Maximum Offset Drift 0.5 uV/°C
Maximum Input Bias Current 5 nA
Minimum Common-Mode Rejection 120 dB
Input Protection ±40 V
Supply Voltage Range ±18 V
Bandwidth at Gain 100 200 kHz
Architecture Three-op-amp instrumentation-amplifier design
Gain Adjustment Single external resistor
Gain Range 1 to 10,000
Temperature Range -40°C to +85°C
Low-Power Feature Low-power instrumentation-amplifier design
Current Feedback Yes

INA129P 8-pin plastic dip (pdip) 引脚配置指南

INA129P(8-pin plastic dip (pdip) 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。

INA129P 的 8-pin plastic dip (pdip) 封装引脚图

暂无详细引脚数据: INA129P.

请参阅 数据手册 以查看完整引脚配置。

典型应用

INA129P 适用于 6 应用s: Load-Cell and Bridge Sensor Signal Conditioning, Industrial Process Measurement, Current-Sense Amplification, Precision Test and Measurement Instrumentation, Medical and Biomedical Instrumentation, Legacy Through-Hole Sensor Interface.

⚖️

Load-Cell and Bridge Sensor Signal Conditioning

The INA129P fits bridge-based measurements because its low maximum offset of 50 uV and low offset drift of 0.5 uV/°C help preserve small differential sensor signals. Its minimum common-mode rejection of 120 dB reduces errors when both bridge outputs move together, while the single external gain resistor supports selectable amplification. Use the amplifier near the bridge input and verify bridge excitation, common-mode range, input impedance, and output swing in the complete circuit. The 200 kHz bandwidth at gain 100 provides useful bandwidth for many industrial load-cell and force-sensor systems, but stability and filtering must be checked at the selected gain.

🏭

Industrial Process Measurement

The INA129P is suitable for low-level process signals that must be measured in the presence of substantial common-mode voltage. Its 120 dB minimum CMR and 5 nA maximum input bias current help reduce errors from long sensor wires and nearby industrial switching equipment. The device's ±18 V supply capability supports dual-supply instrumentation systems, while its three-op-amp architecture simplifies differential measurement around a shared reference. Place the input path close to the sensor, use appropriate filtering, and confirm that the process signal remains inside the amplifier's common-mode and output ranges.

⚡

Current-Sense Amplification

The INA129P can amplify small differential voltages produced by current-sensing resistors when common-mode rejection and low offset are important. The 50 uV maximum offset and 0.5 uV/°C maximum drift are useful when the measured current changes slowly and the system must retain accuracy across temperature. Its current-feedback input circuitry helps preserve bandwidth at higher gain, including the documented 200 kHz figure at gain 100. The power-loss and accuracy budget should include resistor tolerance, Kelvin routing, amplifier supply noise, saturation recovery, and the sensor's maximum current excursion.

🧪

Precision Test and Measurement Instrumentation

The INA129P is appropriate for laboratory and industrial test equipment that measures small differential voltages with limited input current. Its low bias current can reduce loading on high-impedance sources, while the high common-mode rejection helps separate the wanted differential signal from fixture or cable-induced common-mode voltage. The PDIP package is convenient for through-hole prototypes and serviceable instrumentation. For precision results, define the gain resistor tolerance, account for input offset and drift, use shielded or guarded wiring where appropriate, and characterize noise and bandwidth at the actual operating gain rather than relying only on headline specifications.

💊

Medical and Biomedical Instrumentation

The INA129P can be evaluated for biomedical front ends that acquire small differential sensor voltages, subject to application-specific safety and qualification review. Its low offset and drift reduce baseline measurement error, and its high common-mode rejection can help when the sensor is referenced above ground. The ±40 V input-protection claim should not be treated as a complete medical protection scheme; designers must add the required isolation, clamps, leakage analysis, current limiting, and applicable regulatory controls. Confirm the final amplifier selection against the current datasheet and the complete patient-protection circuit.

🛠️

Legacy Through-Hole Sensor Interface

The INA129P is a practical choice for repairing or extending legacy through-hole instrumentation because it is specified in an 8-pin plastic DIP package. Its one-amplifier instrumentation topology and external gain control support replacement of a traditional three-op-amp measurement front end without introducing a new surface-mount footprint. Before installation, compare the replacement's pin functions, supply polarity, input and output ranges, and gain equation with the original circuit. The package is suitable for prototyping, but DIP footprint compatibility alone does not guarantee electrical equivalence or performance in every original design.

What is the INA129P?
The INA129P is a precision, low-power instrumentation amplifier from Texas Instruments. According to the Texas Instruments product page, the INA12x family uses a versatile three-op-amp design and current-feedback input circuitry, while the INA129P is supplied in an 8-pin plastic DIP package. It is designed for low-level differential measurements where common-mode rejection, low offset, and adjustable gain are important. The verified manufacturer search result identifies it as one amplifier circuit, while the DigiKey listing confirms the 8-PDIP package.
What are the key specifications of INA129P that engineers should know?
The INA129P combines a maximum offset voltage of 50 uV, maximum offset drift of 0.5 uV/°C, maximum input bias current of 5 nA, and minimum common-mode rejection of 120 dB. Texas Instruments search data also identifies input protection to ±40 V, supply operation up to ±18 V, and 200 kHz bandwidth at gain 100. These values support precision sensor conditioning, although the current datasheet should be checked for test conditions and detailed absolute-maximum limits before production design.
What is the operating voltage range of INA129P?
The INA129P supports a wide bipolar supply range up to ±18 V, according to the verified INA129P datasheet snippets. In practical circuit design, the actual usable range depends on the selected operating point, input common-mode voltage, output swing, and the load connected to the amplifier. The verified data does not provide a more detailed supply-current or output-swing specification, so those values should be obtained from the current manufacturer datasheet before final schematic release.
How much bandwidth does INA129P provide at gain 100?
The verified Texas Instruments product result states that the INA129 family provides 200 kHz bandwidth at gain 100. This means the INA129P can amplify a small differential sensor signal while retaining useful bandwidth when the gain is raised. Bandwidth still depends on signal amplitude, output loading, supply conditions, and the external gain resistor, so the figure should be treated as a family-level design indicator rather than a complete dynamic-response guarantee.
What is the maximum input protection voltage of INA129P?
The verified INA129P data lists input protection to ±40 V. This protection is useful when sensor wiring can present voltage beyond the normal signal range, but it does not remove the need for correct supply decoupling, grounding, fault analysis, and verification of absolute-maximum conditions. The protection rating should not be interpreted as permission to exceed the device's operating ratings; the current Texas Instruments datasheet is the controlling reference for safe use.
Can INA129P replace INA128P?
The INA129P and INA128P are both listed as 8-pin instrumentation-amplifier devices, but the available evidence does not establish exact pin-for-pin electrical equivalence or a formally verified drop-in relationship. The verified search results include INA128P comparisons and describe the INA12x family, yet they do not provide a complete parameter matrix confirming every pin, gain, supply, and protection condition. Use the manufacturer cross-reference tools or obtain both datasheets before approving INA128P as a replacement.
Is AD620BNZ a drop-in replacement for INA129P?
AD620BNZ is a candidate for design review, but the supplied evidence does not prove that it is a drop-in replacement for INA129P. The GlobalSpec result lists AD620BNZ as an alternative part, while a separate comparison result identifies both devices as 8-pin through-hole instrumentation amplifiers. Same package count alone does not establish pin compatibility, gain behavior, supply limits, input protection, or performance. Verify the AD620 datasheet and compare every pin and electrical limit with the INA129P datasheet before substitution.
Where can I buy INA129P online?
The verified DigiKey result provides a direct INA129P product page and states that the part is available to buy, while Texas Instruments provides the official INA129 product page. Pricing and inventory can change, and the supplied snippets do not include a numerical unit price or current stock quantity. Check the distributor listing for the live commercial terms, then compare the manufacturer product page for ordering and quality information. XAIPART lead time and inventory are also not supplied here.
What is the price of INA129P?
The supplied verified data does not provide a numeric INA129P price. The DigiKey listing offers current purchasing information, but the search snippet contains no price value, and no Internal Database price was provided. The quantity tiers in this record therefore remain marked as data needed rather than being guessed. Use the linked distributor page or request a current quotation from XAIPART for quantity breaks, stock status, and delivery terms.
What is the lead time for INA129P?
The lead time for INA129P cannot be stated from the supplied evidence because no dated inventory or manufacturer lead-time value is included. DigiKey's search result says “ships today,” but that wording is not a guaranteed lead time for every quantity or every order. For purchasing decisions, confirm the current distributor stock, backlog, authorized-source status, and quantity availability. XAIPART's own lead time is also unknown from the provided data.
Is INA129P in stock?
The verified DigiKey result uses the phrase “Buy now, ships today,” which indicates a purchasing listing but does not provide a stable stock count or guarantee. Because no explicit in-stock quantity and timestamp were supplied, XAIPART's commerce availability remains order-on-request or unknown rather than being represented as guaranteed stock. Check the distributor product page for live inventory and request a quotation before placing a production order.
Where can I download the INA129P datasheet PDF?
The official Texas Instruments product page for INA129 is the preferred starting point for the current datasheet, ordering information, and family documentation. The verified search results also include third-party datasheet pages, but manufacturer documentation should control engineering decisions. The supplied material references the INA12x datasheet without providing a verified current document number or page count for this response. Download and review the current INA129 datasheet, including the pinout, absolute-maximum ratings, test conditions, and application guidance.
Where can I find the INA129P pinout?
The INA129P pinout should be taken from the current Texas Instruments INA129 datasheet or the package drawing associated with the 8-pin plastic DIP orderable part. The verified search results confirm an 8-pin PDIP package, but they do not reproduce all eight pin names or descriptions, so a complete pin assignment cannot be fabricated here. Before wiring the device, verify pins for supply, ground, differential inputs, feedback or gain resistor connections, and reference/ground functions directly against the manufacturer document.
What is the best replacement for INA129P?
The best replacement is not established by the supplied data because no candidate is verified as pin-to-pin compatible with the INA129P across gain, supply, input protection, offset, bandwidth, and common-mode requirements. AD620BNZ and INA128P appear in comparison or alternative listings, but package similarity alone is insufficient. The correct process is to obtain each candidate's official datasheet, compare the eight pin functions and key electrical limits, then validate the replacement in the target sensor circuit.
Can an instrumentation amplifier be used for load-cell measurement with INA129P?
Yes, the INA129P is suitable in principle for a load-cell or bridge measurement because it offers low offset, low offset drift, low input bias current, and high common-mode rejection. The external gain resistor can establish the required gain, and the 200 kHz bandwidth at gain 100 provides useful signal bandwidth. Final suitability depends on bridge excitation voltage, sensor impedance, common-mode range, output range, noise requirements, and protection strategy; confirm all of these against the manufacturer datasheet.
When should I choose INA129P over another instrumentation amplifier?
Choose the INA129P when the design needs a low-power precision instrumentation amplifier in an 8-pin plastic DIP package, with documented low offset, low drift, low input bias current, and high common-mode rejection. Choose a different device when you require a different package, rail-to-rail operation, lower noise, higher bandwidth, lower supply voltage, or an explicitly verified cross-brand pin-compatible replacement. The INA129P is especially appropriate for through-hole precision sensing and legacy-compatible instrumentation designs, subject to current datasheet verification.

工程参考数据: INA129P ——对比、设计指导和合规信息。

选型指南

Choose the INA129P when the design needs a precision, low-power, single instrumentation amplifier in an 8-pin plastic DIP package and the verified priorities include low offset, low drift, low input bias current, high common-mode rejection, and input protection. It is a sensible candidate for through-hole bridge, load-cell, current-sense, industrial, and precision test-interface designs when dual-supply operation and the stated bandwidth are acceptable. Choose a different amplifier when the circuit requires rail-to-rail input or output, lower noise, higher speed, lower supply voltage, or an explicitly verified cross-brand pin-compatible replacement. INA129PA and INA128P should be selected only after checking the relevant ordering variant and full datasheet. AD620BNZ or AD620AN may suit a redesign, but same-package appearance alone does not establish that they can replace INA129P without schematic, gain, supply, protection, and performance validation.

与替代料对比

参数 本产品 INA129PA INA128P AD620BNZ AD620AN
Brand Texas Instruments Texas Instruments Texas Instruments Analog Devices Analog Devices
Package PDIP-8 PDIP-8 PDIP-8 PDIP-8 PDIP-8
Product Type Precision low-power instrumentation amplifier Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier

关键差异点

  • Low offset and drift for precision measurement (对比 AD620BNZ)
  • High common-mode rejection (对比 AD620AN)
  • Documented input protection (对比 INA128P)
  • Through-hole instrumentation-amplifier format (对比 AD620AN)

设计说明

Place the INA129P close to the sensor input connector and route the differential pair together to minimize sensitivity to common-mode electric fields and ground potential differences. Keep the gain-setting resistor close to the device where the datasheet layout permits, and provide solid ground returns for both input and output stages. Because the device uses a precision instrumentation-amplifier topology, a long unprotected input trace can degrade common-mode rejection even when the nominal CMR specification is 120 dB minimum.

Design the supply network for the selected dual-supply voltage while preserving adequate input and output common-mode range. The verified data identifies operation up to ±18 V and input protection to ±40 V, but those figures do not remove the need for supply decoupling, current limiting, and fault analysis. Confirm whether the instrumentation uses dual supplies or a restricted single-supply arrangement, and calculate the amplifier's dissipation from the actual supply voltage, output voltage, and load before selecting copper and package thermal margins.

Do not treat the advertised input-protection rating as a complete input overvoltage solution. Verify the absolute-maximum limits, common-mode range, output swing, and external resistor values from the current Texas Instruments datasheet. Also check the source impedance: the documented 5 nA maximum input bias current can create an error when working with very high sensor impedance. For bridge or current-sense circuits, use a defined reference ground and account for resistor tolerance, offset, drift, and filtering in the system error budget.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

The supplied verified snippets identify the INA129P as a Texas Instruments precision low-power instrumentation amplifier in an 8-pin plastic DIP package, but do not provide explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals statements. Compliance fields remain unknown rather than inferred.

相关搜索

INA129P INA129P datasheet Texas Instruments INA129P INA129P precision instrumentation amplifier INA129P ±18 V instrumentation amplifier INA129P 8-pin PDIP INA129P load cell amplifier INA129P current sense amplifier INA129P vs INA128P INA129P vs AD620BNZ INA129P drop-in replacement INA129P price INA129P buy online INA129P pinout What can replace INA129P?

相关元器件 & 术语

Texas Instruments INA129P INA129 INA12x Precision low-power instrumentation amplifier Instrumentation amplifier Operational amplifier Three-op-amp architecture Current-feedback input Common-mode rejection ratio CMR Input offset voltage Offset drift Input bias current Input protection Bridge sensor Load cell Current-sense resistor Industrial process measurement Medical instrumentation PDIP-8 Through-hole package Gain resistor Analog Devices AD620BNZ AD620AN RoHS REACH AEC-Q100
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情