AD7875BQ - 12-Bit 100 kHz SAR ADC | Analog Devices
料号: AD7875BQ ✓ 量产中AD7875BQ 概述
A sampling ADC is a data-converter category that acquires an analog voltage and converts it into a digital code. The AD7875 belongs to the successive-approximation ADC family within the broader analog-to-digital converter and data-converter hierarchy. Its self-contained architecture reduces the number of external support components, while its integrated reference and clock simplify deterministic sampling-system design.
Important features include a 2 µs track-and-hold acquisition time, an 8 µs conversion time, a 57 ns data-access interval, and 72 dB signal-to-noise ratio at a 10 kHz input frequency. The manufacturer describes the AD7875 as a complete monolithic converter with a unified 5 V input range. The combination of 12-bit resolution and 100 kHz throughput supports industrial measurement, process-control, instrumentation, and embedded data-acquisition systems.
Technically, the AD7875 uses a successive-approximation conversion process after the track-and-hold amplifier captures the input voltage. Its 3 V buried-Zener reference supports internal conversion references, while the laser-trimmed internal clock removes the need for an external oscillator. Versatile parallel, byte, and serial interfaces let the converter connect to processors, DSPs, programmable logic, or custom digital controllers while preserving the same sampling core.
Typical uses include process-control loops, transducer measurement, laboratory instrumentation, industrial data loggers, and embedded control systems. Designers can select the parallel interface for straightforward bus capture, the byte interface for microprocessor-compatible transfers, or the serial interface where wiring and board area are more important than maximum bus throughput.
The ceramic DIP package is suitable for through-hole industrial and legacy-system boards, but it is larger than modern surface-mount ADC packages. Before layout work begins, use the manufacturer pin-description table to assign analog, reference, clock, interface, and supply connections. Account for the 24-pin footprint, analog return paths, decoupling placement, and digital switching noise around the converter input.
This page combines the essential ADC specifications, interface and application guidance, verified manufacturer resources, and a practical comparison with closely related AD7875 devices. It is designed to help engineers identify whether the AD7875BQ fits an existing 12-bit, 100 kHz sampling architecture before committing to a legacy through-hole design.
直接替换替代料: AD7875BQ ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: AD7875BQ (相同外形与封装尺寸) ——差异在于 Package, Resolution.
AD7875TQ
✅ 直接替换联系询价
查看数据手册 →AD7875KNZ
✅ 直接替换📋 参考替代料(不在目录中)
AD7875BQ 最大额定值与电气特性
| 分辨率 | 12 bit |
| Converter Type | Successive-approximation ADC |
| Input Channels | 1 channel |
| Conversion Rate | 100 kSPS |
| Conversion Time | 8 µs |
| Track-and-Hold Acquisition Time | 2 µs |
| Signal-to-Noise Ratio | 72 dB at 10 kHz input frequency |
| Data Access Time | 57 ns |
| Internal Reference | 3 V buried-Zener reference |
| Internal Clock | Laser-trimmed self-contained clock |
| Input Range | Unipolar 5 V |
| Digital Interfaces | Parallel, byte, and serial |
| 封装 | 24-lead ceramic DIP (24-CDIP) |
| Process Technology | LC²MOS |
| 安装类型 | Through-hole |
| Analog Input Type | Unipolar single-ended input |
AD7875BQ 24-lead ceramic dip (24-cdip) 引脚配置指南
AD7875BQ(24-lead ceramic dip (24-cdip) 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: AD7875BQ.
请参阅 数据手册 以查看完整引脚配置。
典型应用
AD7875BQ 适用于 6 应用s: Industrial Process Control, Transducer Measurement, Laboratory Instrumentation, Embedded Data Acquisition, Power and Motor Control, Legacy Through-Hole Control Boards.
Industrial Process Control
The AD7875BQ fits process-control loops that need 12-bit measurement resolution and a maximum conversion rate of 100 kSPS. Its integrated 2 µs track-and-hold amplifier captures the sensor signal before the 8 µs successive-approximation conversion, while the internal 3 V buried-Zener reference supports a compact analog front end. The parallel interface can feed a controller quickly, and the byte or serial interface offers flexibility for lower-pin-count embedded designs. Designers should place decoupling close to the supply pins, route analog and digital returns carefully, and confirm the operating-temperature limits against the Analog Devices manufacturer ordering table.
推荐
Transducer Measurement
The AD7875BQ is appropriate for digitizing pressure, temperature, position, and level transducers whose analog outputs require faster conversion than typical low-rate sigma-delta devices. A 12-bit code and 100 kSPS throughput provide a practical balance between measurement speed and implementation complexity. The track-and-hold acquisition stage reduces input movement during conversion, while the 72 dB SNR reported at a 10 kHz input frequency provides a useful input-signal bandwidth reference. Front-end filtering, reference bypassing, and grounding remain essential for repeatable industrial results.
推荐
Laboratory Instrumentation
The AD7875BQ can serve laboratory instruments that sample moderate-bandwidth analog signals while retaining a straightforward 12-bit data path. Its self-contained internal clock and 3 V buried-Zener reference reduce external timing and reference components, helping shorten instrument-development cycles. The 57 ns data-access time supports direct acquisition logic, and engineers can choose parallel, byte, or serial communication according to the instrument's display processor or DSP interface. Calibration code should compensate for offset and gain, while PCB layout should isolate fast digital edges from the analog input and reference paths.
推荐
Embedded Data Acquisition
The AD7875BQ is useful in legacy embedded acquisition systems where a processor requires periodic analog samples without a high-complexity converter. The single input, 12-bit resolution, and selectable digital interfaces allow the same converter core to serve a parallel data bus, a byte-oriented processor, or a serial link. At 100 kSPS, the 8 µs conversion interval leaves practical time for digital control and storage operations. Firmware should validate the selected interface timing, account for the 2 µs acquisition phase, and ensure that analog conditioning presents a stable signal during conversion.
推荐
Power and Motor Control
The AD7875BQ can monitor current, voltage, or position feedback in power-conversion and motor-control subsystems that require rapid sampling. Its 100 kSPS maximum rate and 8 µs conversion time are suitable for supervisory and diagnostic loops, although compensation loops requiring very high update rates may demand a faster converter. The parallel interface supports deterministic acquisition, and the internal reference simplifies instrumentation around the power stage. Keep switching-node coupling out of the ADC input, use a dedicated analog return path, and place input filtering close to the converter for reliable measurements.
推荐
Legacy Through-Hole Control Boards
The AD7875BQ is especially relevant to legacy through-hole control and measurement boards that use a 24-lead ceramic DIP footprint. Its complete monolithic design includes the track-and-hold amplifier, converter, reference, clock, and interface logic, enabling repair or obsolescence-management projects without redesigning the surrounding analog section. The 12-bit, 100 kSPS capability supports general-purpose signal capture but may not satisfy high-end precision requirements. Confirm pin orientation, connector suffix, supply sequencing, and acquisition timing against the Analog Devices manufacturer documentation before fitting the device to an existing PCB.
推荐
推荐产品汇总
工程参考数据: AD7875BQ ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | AD7875TQ | AD7875KNZ |
|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Package | 24-CDIP | 24-CDIP | 24-CDIP |
| Resolution | 12 bit | 12 bit | 12 bit |
| Converter Architecture | Successive approximation | Successive approximation | Successive approximation |
| Conversion Rate | 100 kSPS | 100 kSPS | 100 kSPS |
| Conversion Time | 8 µs | 8 µs | 8 µs |
| Input Channels | 1 channel | 1 channel | 1 channel |
| Internal Reference | 3 V buried-Zener reference | 3 V buried-Zener reference | 3 V buried-Zener reference |
| Digital Interfaces | Parallel, byte, and serial | Parallel, byte, and serial | Parallel, byte, and serial |
关键差异点
- Complete 12-bit sampling converter in one device (对比 AD7875TQ)
- No external sampling clock required (对比 AD7875KNZ)
- Multiple digital-output organizations (对比 AD7875TQ)
设计说明
Place the AD7875BQ close to the source of the analog signal and route the analog input directly to the converter rather than through long traces shared with digital outputs. The 2 µs track-and-hold interval improves acquisition, but it does not remove the need for a stable input during that interval. Use the manufacturer pin-description table to locate supply and analog-ground pins before assigning a footprint.
Keep parallel digital interface traces away from the analog input and internal reference paths. Parallel output switching can couple into a high-impedance input and disturb the 12-bit conversion result. Use a quiet analog return, provide local supply bypassing at the IC pins, and place input filtering close to the source or converter so that unwanted noise is attenuated before sampling.
Do not select AD7875BQ, AD7875TQ, or AD7875KNZ solely because all three are described as 12-bit ADCs. Confirm the exact ordering suffix, temperature grade, package construction, pin assignments, and operating limits in the Analog Devices manufacturer ordering documentation. A drop-in footprint match alone does not establish that a replacement is approved for the original environmental and qualification requirements.
The integrated 3 V buried-Zener reference is a defining feature of the AD7875, but external reference bypassing and supply-decoupling layout still influence measurement stability. Follow the manufacturer's recommended capacitor values and placement directly. Confirm the device's electrical limits in the datasheet before selecting rail tolerances or adding protection networks around sensitive analog inputs.
合规信息
The available product and distributor records do not establish RoHS, REACH, lead-free, halogen-free, or conflict-minerals status. AEC-Q100 is not applicable because the AD7875BQ is an industrial and commercial analog-to-digital converter rather than an automotive-qualified device.