A sampling ADC is a data-converter category that acquires an analog voltage and converts it into a digital code. The AD7875 belongs to the successive-approximation ADC family within the broader analog-to-digital converter and data-converter hierarchy. Its self-contained architecture reduces the number of external support components, while its integrated reference and clock simplify deterministic sampling-system design.
Important features include a 2 µs track-and-hold acquisition time, an 8 µs conversion time, a 57 ns data-access interval, and 72 dB signal-to-noise ratio at a 10 kHz input frequency. The manufacturer describes the AD7875 as a complete monolithic converter with a unified 5 V input range. The combination of 12-bit resolution and 100 kHz throughput supports industrial measurement, process-control, instrumentation, and embedded data-acquisition systems.
Technically, the AD7875 uses a successive-approximation conversion process after the track-and-hold amplifier captures the input voltage. Its 3 V buried-Zener reference supports internal conversion references, while the laser-trimmed internal clock removes the need for an external oscillator. Versatile parallel, byte, and serial interfaces let the converter connect to processors, DSPs, programmable logic, or custom digital controllers while preserving the same sampling core.
Typical uses include process-control loops, transducer measurement, laboratory instrumentation, industrial data loggers, and embedded control systems. Designers can select the parallel interface for straightforward bus capture, the byte interface for microprocessor-compatible transfers, or the serial interface where wiring and board area are more important than maximum bus throughput.
The ceramic DIP package is suitable for through-hole industrial and legacy-system boards, but it is larger than modern surface-mount ADC packages. Before layout work begins, use the manufacturer pin-description table to assign analog, reference, clock, interface, and supply connections. Account for the 24-pin footprint, analog return paths, decoupling placement, and digital switching noise around the converter input.
This page combines the essential ADC specifications, interface and application guidance, verified manufacturer resources, and a practical comparison with closely related AD7875 devices. It is designed to help engineers identify whether the AD7875BQ fits an existing 12-bit, 100 kHz sampling architecture before committing to a legacy through-hole design.
드롭인 대체품: AD7875BQ — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 시리즈의 변형
다음과 드롭인 호환되는 동일 시리즈 모델: AD7875BQ (동일 폼 팩터 및 풋프린트) — 차이점: Package, Resolution.
AD7875TQ
✅ 드롭인가격 문의
데이터시트 보기 →AD7875KNZ
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
AD7875BQ 최대 정격 & 전기적 특성
| 분해능 | 12 bit |
| Converter Type | Successive-approximation ADC |
| Input Channels | 1 channel |
| Conversion Rate | 100 kSPS |
| Conversion Time | 8 µs |
| Track-and-Hold Acquisition Time | 2 µs |
| Signal-to-Noise Ratio | 72 dB at 10 kHz input frequency |
| Data Access Time | 57 ns |
| Internal Reference | 3 V buried-Zener reference |
| Internal Clock | Laser-trimmed self-contained clock |
| Input Range | Unipolar 5 V |
| Digital Interfaces | Parallel, byte, and serial |
| 패키지 | 24-lead ceramic DIP (24-CDIP) |
| Process Technology | LC²MOS |
| 실장 유형 | Through-hole |
| Analog Input Type | Unipolar single-ended input |
AD7875BQ 24-lead ceramic dip (24-cdip) 핀 구성 가이드
AD7875BQ(24-lead ceramic dip (24-cdip) 패키지)의 핀 구성입니다. 이 아날로그 부품에는 입력, 출력, 전원 공급 핀이 있습니다. 오프셋 널, 보상, 인에이블 핀 구성은 제조사 데이터시트를 참조하십시오. 신호 컨디셔닝 및 증폭기 회로에 이상적입니다.
다음에 대한 상세 핀아웃 데이터 없음: AD7875BQ.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
AD7875BQ 적합 용도: 6 애플리케이션s: Industrial Process Control, Transducer Measurement, Laboratory Instrumentation, Embedded Data Acquisition, Power and Motor Control, Legacy Through-Hole Control Boards.
Industrial Process Control
The AD7875BQ fits process-control loops that need 12-bit measurement resolution and a maximum conversion rate of 100 kSPS. Its integrated 2 µs track-and-hold amplifier captures the sensor signal before the 8 µs successive-approximation conversion, while the internal 3 V buried-Zener reference supports a compact analog front end. The parallel interface can feed a controller quickly, and the byte or serial interface offers flexibility for lower-pin-count embedded designs. Designers should place decoupling close to the supply pins, route analog and digital returns carefully, and confirm the operating-temperature limits against the Analog Devices manufacturer ordering table.
추천
Transducer Measurement
The AD7875BQ is appropriate for digitizing pressure, temperature, position, and level transducers whose analog outputs require faster conversion than typical low-rate sigma-delta devices. A 12-bit code and 100 kSPS throughput provide a practical balance between measurement speed and implementation complexity. The track-and-hold acquisition stage reduces input movement during conversion, while the 72 dB SNR reported at a 10 kHz input frequency provides a useful input-signal bandwidth reference. Front-end filtering, reference bypassing, and grounding remain essential for repeatable industrial results.
추천
Laboratory Instrumentation
The AD7875BQ can serve laboratory instruments that sample moderate-bandwidth analog signals while retaining a straightforward 12-bit data path. Its self-contained internal clock and 3 V buried-Zener reference reduce external timing and reference components, helping shorten instrument-development cycles. The 57 ns data-access time supports direct acquisition logic, and engineers can choose parallel, byte, or serial communication according to the instrument's display processor or DSP interface. Calibration code should compensate for offset and gain, while PCB layout should isolate fast digital edges from the analog input and reference paths.
추천
Embedded Data Acquisition
The AD7875BQ is useful in legacy embedded acquisition systems where a processor requires periodic analog samples without a high-complexity converter. The single input, 12-bit resolution, and selectable digital interfaces allow the same converter core to serve a parallel data bus, a byte-oriented processor, or a serial link. At 100 kSPS, the 8 µs conversion interval leaves practical time for digital control and storage operations. Firmware should validate the selected interface timing, account for the 2 µs acquisition phase, and ensure that analog conditioning presents a stable signal during conversion.
추천
Power and Motor Control
The AD7875BQ can monitor current, voltage, or position feedback in power-conversion and motor-control subsystems that require rapid sampling. Its 100 kSPS maximum rate and 8 µs conversion time are suitable for supervisory and diagnostic loops, although compensation loops requiring very high update rates may demand a faster converter. The parallel interface supports deterministic acquisition, and the internal reference simplifies instrumentation around the power stage. Keep switching-node coupling out of the ADC input, use a dedicated analog return path, and place input filtering close to the converter for reliable measurements.
추천
Legacy Through-Hole Control Boards
The AD7875BQ is especially relevant to legacy through-hole control and measurement boards that use a 24-lead ceramic DIP footprint. Its complete monolithic design includes the track-and-hold amplifier, converter, reference, clock, and interface logic, enabling repair or obsolescence-management projects without redesigning the surrounding analog section. The 12-bit, 100 kSPS capability supports general-purpose signal capture but may not satisfy high-end precision requirements. Confirm pin orientation, connector suffix, supply sequencing, and acquisition timing against the Analog Devices manufacturer documentation before fitting the device to an existing PCB.
추천
추천 제품 요약
엔지니어링 참조 데이터: AD7875BQ — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | AD7875TQ | AD7875KNZ |
|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Package | 24-CDIP | 24-CDIP | 24-CDIP |
| Resolution | 12 bit | 12 bit | 12 bit |
| Converter Architecture | Successive approximation | Successive approximation | Successive approximation |
| Conversion Rate | 100 kSPS | 100 kSPS | 100 kSPS |
| Conversion Time | 8 µs | 8 µs | 8 µs |
| Input Channels | 1 channel | 1 channel | 1 channel |
| Internal Reference | 3 V buried-Zener reference | 3 V buried-Zener reference | 3 V buried-Zener reference |
| Digital Interfaces | Parallel, byte, and serial | Parallel, byte, and serial | Parallel, byte, and serial |
주요 차별점
- Complete 12-bit sampling converter in one device (vs AD7875TQ)
- No external sampling clock required (vs AD7875KNZ)
- Multiple digital-output organizations (vs AD7875TQ)
설계 노트
Place the AD7875BQ close to the source of the analog signal and route the analog input directly to the converter rather than through long traces shared with digital outputs. The 2 µs track-and-hold interval improves acquisition, but it does not remove the need for a stable input during that interval. Use the manufacturer pin-description table to locate supply and analog-ground pins before assigning a footprint.
Keep parallel digital interface traces away from the analog input and internal reference paths. Parallel output switching can couple into a high-impedance input and disturb the 12-bit conversion result. Use a quiet analog return, provide local supply bypassing at the IC pins, and place input filtering close to the source or converter so that unwanted noise is attenuated before sampling.
Do not select AD7875BQ, AD7875TQ, or AD7875KNZ solely because all three are described as 12-bit ADCs. Confirm the exact ordering suffix, temperature grade, package construction, pin assignments, and operating limits in the Analog Devices manufacturer ordering documentation. A drop-in footprint match alone does not establish that a replacement is approved for the original environmental and qualification requirements.
The integrated 3 V buried-Zener reference is a defining feature of the AD7875, but external reference bypassing and supply-decoupling layout still influence measurement stability. Follow the manufacturer's recommended capacitor values and placement directly. Confirm the device's electrical limits in the datasheet before selecting rail tolerances or adding protection networks around sensitive analog inputs.