ADM239LAQ - 120 kbps RS-232 Interface | Analog Devices
料号: ADM239LAQ ✓ 量产中ADM239LAQ 概述
An RS-232 interface IC is a semiconductor that converts logic-level signals between a host or peripheral and the voltage levels used by the EIA-232-E serial bus. The ADM239LAQ combines CMOS transceivers, charge-pump converters, driver slew control, receiver threshold detection, and shutdown control in one integrated device. It sits between digital logic and the physical RS-232 connector.
Key features include operation from a single +5 V supply, support for 120 kbps data rates, TTL- and CMOS-compatible receiver thresholds, and low-power shutdown. The on-board DC-DC converters generate the elevated voltage required for RS-232 driver outputs. A 9 V output swing from the 5 V supply supports reliable communication over longer cable runs than a conventional ±5 V-compatible interface.
The receiver switching threshold is VCC/4, which is 1.25 V typical at a 5 V supply. Unused receiver inputs may remain unconnected because an internal 400 kΩ pull-up forces the corresponding output low. The EIA-232-E implementation also limits driver slew rate, helping control unwanted ringing and electromagnetic interference on connected cables.
Typical applications include industrial serial controllers, test and measurement equipment, point-of-sale terminals, diagnostic interfaces, and embedded systems that need bidirectional RS-232 communication without an external negative supply. The device is particularly useful when equipment must combine several RS-232 ports with low-power standby operation on a single 5 V rail.
Designers should follow the manufacturer datasheet for external charge-pump capacitor selection, receiver and driver pin assignments, and unused-channel handling. Place the required capacitors close to their associated pins and route the RS-232 connector interface away from sensitive analog or high-speed digital circuits to minimize coupling.
This page combines the ADM239LAQ electrical characteristics, interface guidance, application fit, and verified sourcing information in one engineering-focused reference. It helps designers distinguish the device's integrated DC-DC architecture, 120 kbps capability, shutdown behavior, and 30 V receiver tolerance when planning an RS-232 interface.
直接替换替代料: ADM239LAQ ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
ADM239LANZ
✅ 直接替换📋 参考替代料(不在目录中)
ADM239LAQ 规格参数
| 电源电压 | +5 V |
| 数据速率 | 120 kbps |
| Driver and Receiver Configuration | 3 drivers and 3 receivers |
| RS-232 Output Swing | 9 V |
| External Charge-Pump Capacitors | 1 uF |
| Receiver Maximum Input Voltage | 30 V |
| Receiver Switching Threshold | VCC/4 |
| Nominal Receiver Switching Threshold at 5 V | 1.25 V typical |
| Input Logic Compatibility | TTL and CMOS compatible |
| Unused Input Pull-Up Resistance | 400 kΩ |
| Driver Slew Rate | Less than 30 V/ms |
| Power Shutdown | Low-power shutdown |
| Receivers Active During Shutdown | Yes |
| RS-232 Compliance | EIA-232-E and V.28 specifications |
| Power Conversion | On-board DC-DC converters |
| 封装 | CDIP-24 |
ADM239LAQ cdip-24 引脚配置指南
ADM239LAQ(cdip-24 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。
暂无详细引脚数据: ADM239LAQ.
请参阅 数据手册 以查看完整引脚配置。
典型应用
ADM239LAQ 适用于 6 应用s: Industrial Serial Controllers, Test and Measurement Equipment, Point-of-Sale Terminals, Embedded Diagnostic Interfaces, Legacy Communication Port Expansion, Security and Access Systems.
Industrial Serial Controllers
The ADM239LAQ fits industrial equipment that must expose legacy RS-232 ports from a 5 V control board. Three drivers and three receivers provide six communication channels, while the integrated DC-DC converters produce an approximately 9 V driver swing without an external negative supply. Its 120 kbps rate is appropriate for configuration links, service consoles, and supervisory communications. The key design trade-off is that the CDIP-24 package occupies more board area than a compact surface-mount transceiver.
推荐
Test and Measurement Equipment
The ADM239LAQ is appropriate for test and measurement instruments that retain RS-232 control ports for legacy computers and service technicians. A single 5 V rail powers the interface, and the on-board converters avoid a separate negative rail for the three driver channels. Receiver inputs rated to 30 V improve tolerance to connected cable conditions. The 120 kbps limit supports terminal and control traffic rather than bulk instrument-data transfer.
推荐
Point-of-Sale Terminals
The ADM239LAQ can serve point-of-sale terminals requiring several RS-232 peripherals, such as scales, printers, or customer-display equipment. Its three transmitters and three receivers provide useful channel density within one ceramic DIP package, while 5 V-only operation simplifies the power architecture. Low-power shutdown supports systems that spend substantial time idle. Designers should treat the approximately 9 V output swing as a platform advantage over basic single-supply line drivers.
推荐
Embedded Diagnostic Interfaces
The ADM239LAQ is useful in embedded diagnostic equipment that communicates with service tools through an RS-232 port while maintaining a 5 V power budget. The receivers remain active during shutdown, allowing selected receive paths to continue monitoring where the system architecture requires it. The 30 V receiver-input rating improves robustness on connected diagnostic cables. A ceramic DIP format is appropriate for legacy repairability but requires careful connector placement and mechanical planning.
推荐
Legacy Communication Port Expansion
The ADM239LAQ can expand an embedded controller that retains one or more older RS-232 ports but has limited driver and receiver resources. Each device adds three driver outputs and three receiver inputs, all operating from the same 5 V supply as many embedded systems. Its 120 kbps rating is suitable for command and status traffic. The design trade-off is the relatively large CDIP-24 footprint compared with modern multichannel interface packages.
推荐
Security and Access Systems
The ADM239LAQ can support access-control panels, alarm controllers, and configuration links that use RS-232 as an auxiliary communication interface. Six transceiver channels allow multiple readers, supervisory terminals, or service interfaces to coexist, and the integrated converters remove the need for a separate negative supply. Shutdown behavior can reduce consumption in idle installations. Engineers should still verify cable length, ground strategy, and the 30 V receiver-input limit at the board interface.
推荐
工程参考数据: ADM239LAQ ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 |
|---|---|
| Package | CDIP-24 |
| Brand | Analog Devices |
| Supply Voltage | +5 V |
| Data Rate | 120 kbps |
| Driver and Receiver Configuration | 3 drivers and 3 receivers |
| RS-232 Output Swing | 9 V |
| Receiver Maximum Input Voltage | 30 V |
| Receiver Switching Threshold | VCC/4, 1.25 V typical at 5 V |
| External Capacitor Value | 1 uF |
| Shutdown Capability | Low-power shutdown with receivers active |
关键差异点
- Three full-duplex RS-232 channels in one package (对比 MC1489NG4)
- Single-supply architecture with elevated driver swing (对比 MC1488NE4)
- Receive-side protection and shutdown flexibility (对比 MC1489NE4)
设计说明
Place the 1 uF charge-pump capacitors close to the pins specified by the manufacturer datasheet and minimize loop area between each capacitor and its associated device pin. Keep the RS-232 driver and connector traces away from sensitive analog inputs and high-speed digital nets. A solid ground plane beneath the interface can improve return-path continuity, but connector ground and logic ground should be arranged to prevent large return currents from crossing sensitive signal paths.
The ADM239LAQ operates from a single +5 V supply and generates the elevated RS-232 output voltage internally. Follow the datasheet capacitor values and connection diagram rather than substituting generic charge-pump networks. Confirm that 5 V remains within the device's operating limits during startup and transient conditions. Because the driver can produce approximately 9 V swing, decouple the supply locally and keep the power-distribution path short to minimize switching-current excursions.
Do not treat an unused ADM239LAQ receiver input as mandatory to terminate if the circuit must remain in the documented inactive state. The internal 400 kΩ pull-up can force an unused input high and the corresponding output low, but leaving unused drivers unconnected requires different care because an undriven RS-232 output may create an uncontrolled interface state. Consult the pin-description table and explicitly configure every driver, receiver, supply, shutdown, and charge-pump connection.
合规信息
The Analog Devices datasheet identifies EIA-232-E and V.28 specification compliance. Specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals declarations require confirmation from the manufacturer.