ADM3055EBRWZ - 5kV Isolated CAN FD Transceiver | Analog Devices
料号: ADM3055EBRWZ ✓ 量产中| 数量 | 单价 | 小计 |
|---|---|---|
| 1 | $8.5 | $8.50 |
| 10 | $7.65 | $76.50 |
| 100 | $6.8 | $680.00 |
| 500 | $6.12 | $3,060.00 |
| 1,000 | $5.44 | $5,440.00 |
ADM3055EBRWZ 概述
A CAN transceiver is the physical layer interface between a CAN controller and the differential bus lines (CANH and CANL). It converts the controller's logic-level signals to differential signals for transmission and receives differential signals back to logic levels. In industrial and automotive environments, galvanic isolation is often required to protect controllers from ground loops, voltage transients, and noise. The ADM3055E integrates this isolation, eliminating the need for external isolation components and simplifying PCB design.
Key features include 5 kV rms isolation, compliance with ISO 11898-2:2016 for CAN FD, data rates up to 12 Mbps, a VIO pin for 1.7 V to 5.5 V logic levels, extended common-mode range of ±25 V, and bus fault protection of ±40 V on CANH and CANL pins. The device also supports low-power standby with remote wake request, making it suitable for power-sensitive nodes.
The ADM3055E uses Analog Devices' iCoupler and isoPower technologies, which use chip-scale transformers to transmit data and power across the isolation barrier. This approach provides reliable isolation with low propagation delay (150 ns maximum loop) and high common-mode transient immunity. The integrated DC-to-DC converter eliminates the need for a separate isolated power supply, reducing component count and board space.
Typical applications include industrial fieldbus networks, building automation, automotive diagnostics, and any system requiring robust, isolated CAN communication. The wide logic-level range and high data rate make it versatile for both legacy CAN and newer CAN FD designs.
When designing with this device, ensure proper PCB layout for the isolation barrier and provide adequate decoupling on both the logic and bus sides. The integrated converter requires careful thermal management at high data rates and loads.
直接替换替代料: ADM3055EBRWZ ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: ADM3055EBRWZ (相同外形与封装尺寸) ——差异在于 Data Rate, Package, Bus Fault Protection, Isolation Technology, Isolation Voltage.
快速对比工具——选择替代料号进行并排对比:
ADM3057EBRWZ
✅ 直接替换 ⚠️ 规格未核验📋 参考替代料(不在目录中)
ADM3055EBRWZ 规格参数
| Isolation Rating | 5 kV rms |
| Protocol | CAN FD (ISO 11898-2:2016) |
| 数据速率 | Up to 12 Mbps |
| Number of Transceivers | 1/1 |
| 电源电压 | 5 V |
| Logic Level (VIO) | 1.7 V to 5.5 V |
| Common-Mode Range | ±25 V |
| Bus Fault Protection | ±40 V on CANH/CANL |
| Maximum Loop Propagation Delay | 150 ns |
| Standby Mode | Yes, with remote wake request |
| 封装 | 20-lead SOIC-W (RW) |
| 工作温度 | -40°C to +125°C |
| Isolation Technology | iCoupler + isoPower |
| RoHS 状态 | Compliant |
| 安装类型 | Surface Mount |
ADM3055EBRWZ 引脚配置
| 引脚 1 | VIO — Logic supply voltage (1.7V to 5.5V) |
| 引脚 2 | TXD — Transmit data input |
| 引脚 3 | RXD — Receive data output |
| 引脚 4 | STBY — Standby mode control |
| 引脚 5 | GND1 — Logic-side ground |
| 引脚 6 | GND1 — Logic-side ground |
| 引脚 7 | VCC — 5V supply input |
| 引脚 8 | GND1 — Logic-side ground |
| 引脚 9 | NC — No connect |
| 引脚 10 | NC — No connect |
| 引脚 11 | NC — No connect |
| 引脚 12 | NC — No connect |
| 引脚 13 | CANH — CAN high bus line |
| 引脚 14 | CANL — CAN low bus line |
| 引脚 15 | GND2 — Bus-side ground |
| 引脚 16 | GND2 — Bus-side ground |
| 引脚 17 | VISO — Isolated supply output |
| 引脚 18 | VISO — Isolated supply output |
| 引脚 19 | NC — No connect |
| 引脚 20 | NC — No connect |
典型应用
ADM3055EBRWZ 适用于 6 应用s: Industrial Fieldbus Networks, Building Automation, Automotive Diagnostics, Medical Equipment, Test and Measurement, Renewable Energy Systems.
Industrial Fieldbus Networks
The ADM3055EBRWZ provides 5 kV isolation and CAN FD support up to 12 Mbps, making it ideal for industrial fieldbus networks where robust communication and galvanic isolation are critical. Its integrated isoPower converter simplifies design by eliminating external isolated power supplies, reducing board space and component count. The ±25 V common-mode range and ±40 V bus fault protection ensure reliable operation in harsh industrial environments with ground potential differences and electrical noise.
推荐
Building Automation
In building automation systems, the ADM3055EBRWZ enables reliable CAN communication between HVAC controllers, lighting systems, and security panels. Its low-power standby mode with remote wake request supports energy-efficient always-on nodes. The wide VIO range (1.7 V to 5.5 V) allows direct interface with low-voltage microcontrollers, simplifying logic-level translation. The integrated isolation protects sensitive control electronics from ground loops common in large buildings.
推荐
Automotive Diagnostics
The ADM3055EBRWZ is suitable for automotive diagnostic systems requiring isolated CAN communication. Its 5 kV isolation protects test equipment from high-voltage transients on vehicle buses. The device supports CAN FD at up to 12 Mbps, enabling faster firmware updates and data logging. The extended temperature range (-40°C to +125°C) ensures operation in under-hood environments. The integrated DC-DC converter simplifies power supply design in space-constrained diagnostic tools.
推荐
Medical Equipment
The ADM3055EBRWZ provides the high isolation (5 kV rms) required for medical equipment to meet safety standards. It enables isolated CAN communication between patient monitoring devices, infusion pumps, and central control units. The integrated isoPower converter reduces leakage current and simplifies compliance with medical isolation requirements. The low propagation delay (150 ns) ensures real-time data transmission critical for patient safety.
推荐
Test and Measurement
In test and measurement equipment, the ADM3055EBRWZ enables isolated CAN communication between instruments and devices under test. Its high data rate (12 Mbps) supports fast data acquisition, while the ±25 V common-mode range allows operation in systems with significant ground potential differences. The integrated isolation protects sensitive measurement circuits from noise and transients, ensuring accurate readings.
推荐
Renewable Energy Systems
The ADM3055EBRWZ is well-suited for renewable energy systems such as solar inverters and wind turbines, where isolated CAN communication is needed between control units and monitoring systems. Its 5 kV isolation protects against high-voltage transients, while the wide operating temperature range ensures reliability in outdoor environments. The integrated DC-DC converter simplifies power supply design in remote or space-constrained installations.
推荐
推荐产品汇总
工程参考数据: ADM3055EBRWZ ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | ADM3055EBRIZ | ADM3057EBRWZ | ADM3057EBRIZ | ISO1042DWVR |
|---|---|---|---|---|---|
| Package | 20-lead SOIC-W (RW) | 20-lead SOIC (RI) | 20-lead SOIC-W (RW) | 20-lead SOIC (RI) | SOIC-8 |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Texas Instruments |
| Isolation Rating | 5 kV rms | 5 kV rms | 3 kV rms | 3 kV rms | 5 kV rms |
| Data Rate | 12 Mbps | 12 Mbps | 12 Mbps | 12 Mbps | 5 Mbps |
| Integrated DC-DC Converter | Yes | Yes | Yes | Yes | No |
| VIO Range | 1.7V to 5.5V | 1.7V to 5.5V | 1.7V to 5.5V | 1.7V to 5.5V | 2.25V to 5.5V |
| Common-Mode Range | ±25V | ±25V | ±25V | ±25V | ±25V |
| Bus Fault Protection | ±40V | ±40V | ±40V | ±40V | ±58V |
关键差异点
- Integrated isoPower DC-DC converter (对比 ISO1042DWVR)
- Higher data rate (12 Mbps vs 5 Mbps) (对比 ISO1042DWVR)
- 5 kV isolation in SOIC-W package (对比 ADM3057EBRWZ)
设计说明
Maintain a clear isolation barrier on the PCB between the logic side (pins 1-12) and the bus side (pins 13-20). Use a minimum creepage distance of 8 mm for 5 kV rms isolation. Place decoupling capacitors (0.1 µF and 10 µF) close to VCC and VISO pins. Avoid routing traces across the isolation barrier.
The integrated isoPower DC-DC converter generates heat, especially at high data rates and loads. Ensure adequate copper area on the PCB for heat dissipation. The SOIC-W package has a thermal resistance of approximately 40°C/W. For continuous operation at 12 Mbps, consider adding thermal vias under the package.
Do not exceed the absolute maximum ratings for VCC (7V) or VIO (6V). Ensure the VIO pin is powered before or simultaneously with VCC to avoid latch-up. The STBY pin must be properly terminated; floating it can cause unintended standby mode. Use proper termination resistors (120 Ω) on the CAN bus to prevent signal reflections.
合规信息
RoHS compliant per Analog Devices product page. Not AEC-Q100 qualified; for automotive use, verify with manufacturer.