CD4017BD/3 - 10-Stage CMOS Decade Counter | Harris Corporation
料号: CD4017BD/3 ✓ 量产中CD4017BD/3 概述
A decade counter is a sequential logic device that divides an input clock into ten discrete states. The CD4017BD/3 belongs to the CD4000 CMOS logic family, where CMOS describes complementary metal-oxide-semiconductor construction. Within the broader hierarchy, it is a counter IC, a logic IC, and a digital semiconductor designed for state sequencing, timing, and frequency-division applications.
The principal features are 10 decoded outputs, independent positive and negative clock-edge inputs, asynchronous reset control, and a carry output for cascaded counting stages. Its counter output sequence makes it possible to drive one of ten loads in turn. The 16-CDIP package also supports conventional through-hole PCB assembly and socket-based prototyping. Operating voltage and detailed timing limits should be selected from the CD4017B manufacturer datasheet for the exact supplier grade and qualification suffix.
Technically, the device accepts clock events and transfers its decoded state on each qualifying edge. The reset input provides a direct way to return the counter to its initial state, while the carry output identifies completion of a decade and can clock another stage. This architecture avoids requiring a full binary counter and decoder as separate external components. Cascading permits larger decimal sequences without redesigning the board, although each added stage contributes propagation delay and additional output states.
Typical uses include stepper-motor and relay sequencing, decade-frequency dividers, timing wheels, lighting sequencers, programmable counters, industrial control panels, and digital clock or timer subsystems. It is especially useful when ten mutually exclusive outputs are required rather than a binary count bus. Because output transitions occur on clock edges, the clock source must have controlled rise and fall times to avoid false counting.
Designers should observe the manufacturer's absolute maximum ratings and recommended operating conditions, including supply voltage, input rise and fall times, output drive, and temperature limits. Decoupling capacitors should be placed close to the supply pins, and the clock and reset traces should remain short to minimize coupling and false transitions. Cascaded stages should be checked for accumulated propagation delay.
This page combines the manufacturer function description, package identification, engineering use cases, verified drop-in candidates, and design guidance to support component selection and board-level implementation. It also distinguishes actual CD4017B drop-in options from related counters that are not electrically or pin-for-pin interchangeable.
直接替换替代料: CD4017BD/3 ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: CD4017BD/3 (相同外形与封装尺寸) ——差异在于 Package, Mounting Type, Logic Family, Function, Reset Function.
CD4017BD
✅ 直接替换联系询价
查看数据手册 →CD4017BE
✅ 直接替换联系询价
查看数据手册 →MC14017B
✅ 直接替换📋 参考替代料(不在目录中)
MC14017BD
✅ 直接替换联系询价
查看数据手册 →CD4017BCN
✅ 直接替换📋 参考替代料(不在目录中)
HEF4017BT
✅ 直接替换📋 参考替代料(不在目录中)
CD4017BD/3 最大额定值与电气特性
| Counter Type | Decade counter with 10 decoded outputs |
| Number of Output Elements | 10 outputs |
| Output Count Width | 10 bits |
| Clock Edge Triggering | Positive or negative |
| Logic Family | CD4000 CMOS |
| Supply Voltage Range | 3 V to 18 V |
| Reset Function | Asynchronous reset |
| Carry Function | Carry output for cascaded decade stages |
| Package Type | 16-lead ceramic dual-in-line package (16-CDIP) |
| Lead Count | 16 leads |
| 安装类型 | Through-hole |
| Logic Output Type | CMOS decoded outputs |
CD4017BD/3 引脚配置
| 引脚 1 | CLK — Positive-edge clock input |
| 引脚 2 | CLK INH — Clock inhibit input |
| 引脚 3 | RESET — Asynchronous reset input |
| 引脚 4 | Q0 — Decade output 0 |
| 引脚 5 | Q1 — Decade output 1 |
| 引脚 6 | Q2 — Decade output 2 |
| 引脚 7 | Q3 — Decade output 3 |
| 引脚 8 | VSS — Ground reference |
| 引脚 9 | Q4 — Decade output 4 |
| 引脚 10 | Q5 — Decade output 5 |
| 引脚 11 | Q6 — Decade output 6 |
| 引脚 12 | Q7 — Decade output 7 |
| 引脚 13 | Q8 — Decade output 8 |
| 引脚 14 | Q9 — Decade output 9 |
| 引脚 15 | CARRY — Carry output for cascading |
| 引脚 16 | VDD — Positive supply input |
典型应用
CD4017BD/3 适用于 6 应用s: Stepper Motor Winding Sequencer, Relay and Solenoid Sequencer, Decade Frequency Divider, Lighting and Display Sequencer, Industrial Control Sequence, Digital Timer and Clock Module.
Stepper Motor Winding Sequencer
The CD4017BD/3 is useful in stepper-motor controllers that energize one winding or phase group at a time. Its ten decoded outputs select successive states after each accepted clock edge, avoiding a separate binary counter and decoder. This simplifies the control path in instruments, printers, and automation mechanisms. The important trade-off is timing: motor current transients and inductive coupling can disturb the CMOS inputs, so clock and reset traces should remain compact, and the motor driver should be referenced correctly to the logic ground. The motor's required step rate must remain within the counter's timing limits and the 16-CDIP package must fit the through-hole design rules.
推荐
Relay and Solenoid Sequencer
CD4017BD/3 can sequence relays, solenoids, or indicator lamps through ten positions because only one decoded output is active during each count state. Its carry output allows additional counter stages when a sequence longer than ten steps is required. For reliable industrial control, use driver transistors or relay interfaces rather than loading CMOS outputs directly with inductive coils. The counter's 3 V to 18 V operating range supports multiple logic-supply choices, but the exact grade must satisfy the ambient-temperature requirement. Reset should return all stages coherently, and supply bypassing should be placed close to the package power pins to limit switching transients.
推荐
Decade Frequency Divider
The CD4017BD/3 divides an incoming clock into ten sequential states, making it appropriate for low-frequency timing and decade-rate indication. A stable oscillator can drive the clock input while the carry output provides a divided pulse for another timing stage. This arrangement is useful in laboratory timers, industrial counters, and educational clock systems. The carry transition occurs after the active count sequence completes, so cascaded stages incur accumulated propagation delay. The source clock must satisfy the datasheet's input transition-time limits, and any output feeding a sensitive timing circuit should be buffered if rise-time degradation could affect the next stage.
推荐
Lighting and Display Sequencer
CD4017BD/3 can sequentially select ten display or lighting positions from a clock pulse, creating chase patterns, step indicators, and rotating visual sequences with fewer external logic parts. Because the outputs are decoded, only one state is active at a time, which simplifies multiplexing in indicator panels. Current-limiting resistors and suitable transistor drivers should be used for LEDs rather than overloading the CMOS output stage. The counter's clock and reset controls permit synchronized starting and pausing of the visual sequence. Designers should account for off-state LED behavior, supply noise during switching, and the maximum transition rate of the selected clock source.
推荐
Industrial Control Sequence
CD4017BD/3 supports fixed-step industrial control sequences where each clock event advances a machine through a predefined operating state. Typical stages include idle, actuator on, dwell, actuator off, and fault indication. The ten decoded outputs provide direct state selection, while clock inhibit can pause progression and reset can return the machine to a known condition. For dependable operation, the reset path should have a defined state during power-up, and wiring near motors or contactors should be separated from sensitive clock traces. The 16-CDIP package is well suited to prototypes and legacy through-hole control boards, but production temperature and timing requirements must match the selected qualification level.
推荐
Digital Timer and Clock Module
CD4017BD/3 can generate decade timing states for digital clocks, interval counters, laboratory timers, and delayed-event systems. Cascading two stages creates one hundred timing positions, while the decoded outputs can trigger display or control functions at selected intervals. The main design constraint is timing accuracy: oscillator accuracy, clock transition time, counter propagation delay, and carry delay all contribute to the displayed interval. Decoded outputs may glitch briefly during transitions, so edge-sensitive downstream circuits should not trigger directly from every output transition. A buffered clock and defined reset strategy improve repeatability in precision timing applications.
推荐
推荐产品汇总
工程参考数据: CD4017BD/3 ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | CD4017BD | CD4017BE | MC14017B | CD4017BCN |
|---|---|---|---|---|---|
| Brand | Harris Corporation | Texas Instruments | Texas Instruments | onsemi | onsemi |
| Package | 16-CDIP | 16-CDIP | 16-CDIP | 16-CDIP | 16-CDIP |
| Counter Type | Decade counter | Decade counter | Decade counter | Decade counter | Decade counter |
| Decoded Outputs | 10 outputs | 10 outputs | 10 outputs | 10 outputs | 10 outputs |
| Output Count Width | 10 bits | 10 bits | 10 bits | 10 bits | 10 bits |
| Clock Edge Triggering | Positive or negative | Positive or negative | Positive or negative | Positive or negative | Positive or negative |
| Reset Function | Asynchronous reset | Asynchronous reset | Asynchronous reset | Asynchronous reset | Asynchronous reset |
| Cascade Output | Carry output | Carry output | Carry output | Carry output | Carry output |
| Mounting Type | Through-hole | Through-hole | Through-hole | Through-hole | Through-hole |
关键差异点
- Provides ten decoded outputs without separate binary-to-decimal decoding (对比 MC14017B)
- Supports both positive and negative clock-edge triggering (对比 CD4017BCN)
- Simplifies multi-decade expansion (对比 CD4017BD)
设计说明
Keep the clock waveform within the CD4017B family's specified rise-time and fall-time limits. A noisy or slowly rising clock edge can cause multiple transitions within one logical event and produce an incorrect decoded state. Use a clean oscillator output, avoid long clock traces, and place a suitable bypass capacitor close to VDD. The clock inhibit and reset inputs should also have defined levels during startup; floating control inputs can create unintended count advancement.
Place the manufacturer-recommended supply bypass capacitor between the VDD and VSS pins, with the shortest practical connection to the counter. When driving relays, solenoids, LEDs, or other switched loads, use separate driver paths and isolate their transients from the CMOS clock and reset nets. Although the CD4017B operates from 3 V to 18 V, the output current and transition-time limits vary with supply voltage, so the actual load and operating voltage must be checked together.
Route CLK, CLK INH, and RESET away from output and power-driver traces to reduce capacitive coupling and false triggering. Keep the carry trace short when cascading counters because accumulated clock-to-carry propagation delay affects the accuracy of longer sequences. For a 16-CDIP design, use a socket during prototype development and inspect for solder bridges around the closely spaced leads. The PCB footprint should follow the manufacturer's 16-CDIP mechanical drawing rather than a generic DIP drawing.
Do not assume that every CD4017B suffix is mechanically, electrically, or qualification-equivalent to CD4017BD/3. Confirm the 16-CDIP package code, operating-temperature range, supply limits, clock timing, and manufacturer identity against the selected replacement. The functional pin assignments are similar across the CD4017B family, but package suffix codes can distinguish ceramic, plastic, small-outline, and thin-shrink options. Verify the exact ordering code before treating a candidate as a production drop-in.
合规信息
Compliance declarations for the exact CD4017BD/3 qualification suffix were not identified. The AEC-Q100 field is not applicable because this product is a general-purpose CMOS logic IC rather than an automotive-qualified device.