Vicor

DCM2322T50T2660T60 - 60W 9-50V to 24V Isolated DC-DC | Vicor

料号: DCM2322T50T2660T60 ✓ 量产中
有现货 1-3 个工作日内发货
9 Vdc to 50 Vdc Vdss 2.50 A Id Vicor ChiP through-hole module (DCM2322) Package
低至 $84.77 USD / 件
最小起订量: 1 |
价格更新于: 2026-10-13
批量定价
数量 单价 小计
1 $141.29 $141.29
10 $127.16 $1,271.60
100 $113.03 $11,303.00
500 $98.9 $49,450.00
1,000 $84.77 $84,770.00
ℹ️ 所有价格均以 USD 计价

DCM2322T50T2660T60 概述

The Vicor DCM2322T50T2660T60 is an isolated, regulated DC-DC converter module delivering up to 60 W output power with 2.50 A continuous output current, housed in the Vicor ChiP (Converter housed in Package) through-hole module format. It accepts a wide 9-50 Vdc input range and provides a fixed 24 V nominal SELV (Safety Extra Low Voltage) output, making it well suited to industrial 24 V bus systems. The device achieves a peak efficiency of 88.7% and delivers an industry-leading 266 W/in³ power density thanks to its ZVS (Zero-Voltage Switching) high-frequency architecture.

An isolated, regulated DC-DC converter is a power module that converts one DC voltage to another while providing galvanic isolation between input and output. Galvanic isolation breaks the electrical conduction path, allowing grounds of different sections of a system to float independently and to break ground loops. Within the broader taxonomy, the DCM2322 sits in the isolated DC-DC converter family, which is itself a subclass of DC-DC converters, falling under the power management umbrella of integrated electronic components. These modules pair a fixed input-side bus with downstream point-of-load rails in industrial, railway, and aerospace systems.

Key features include 3000 Vdc isolation, full output regulation, integrated input and output filtering on select pins, and a T-grade internal operating temperature range of -40°C to +125°C. The DCM2322 platform uses a ZVS buck-boost topology combined with Vicor's proprietary ChiP packaging, achieving low-noise switching and high power density in a small footprint. The ChiP module exposes -IN and +IN power pins plus -OUT and +OUT power pins, with the negative pins serving as the reference for control signals and Kelvin connection.

Typical applications include industrial 24 V bus power systems, factory automation controllers, railway rolling-stock auxiliary power, and distributed 24 V power for embedded computing. The wide 9-50 Vdc input also covers 12 V, 24 V, and 36/48 V battery systems, allowing one module to span multiple bus architectures. The fixed 24 V nominal output is convenient for powering sensors, PLC I/O, and downstream point-of-load converters.

When designing with the DCM2322T50T2660T60, observe Kelvin connection practices on the -IN pin to minimize voltage drop across the control reference. Ensure that heat sinking or forced-air cooling accounts for worst-case dissipation at minimum input voltage where efficiency drops. The module is SELV-compliant when properly integrated, but the input side retains a higher voltage potential and requires appropriate fusing.

This page synthesizes distributor pricing, parametric proximity-rated alternatives, and PCB Kelvin-connection design notes that complement - rather than duplicate - the manufacturer datasheet.

直接替换替代料: DCM2322T50T2660T60 ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

快速对比工具——选择替代料号进行并排对比:

DCM2322T50T2660M60

✅ 直接替换
📦 Vicor ChiP DCM2322 through-hole
M-Grade internal temp range -55°C to +125°C vs T-Grade -40°C to +125°C; same 24 Vout, 60 W, 3000 Vdc isolation

📋 参考替代料(不在目录中)

DCM2322T72S2660T60

✅ 直接替换 ⚠️ 规格未核验
📦 Vicor ChiP DCM2322 through-hole
Same 24 Vout 60 W output; DCM2322T72 variant shares identical ChiP footprint per Vicor family

📋 参考替代料(不在目录中)

DCM2322T50T3160T60

✅ 直接替换
📦 Vicor ChiP DCM2322 through-hole
Same 9-50 Vin, 60 W, ChiP DCM2322 footprint; output code 3160 = 31.5 Vout vs 2660 = 24 Vout (+31%)

📋 参考替代料(不在目录中)

DCM2322T50T1760M60

✅ 直接替换
📦 Vicor ChiP DCM2322 through-hole
Same 9-50 Vin, 60 W, 3000 Vdc isolation, ChiP DCM2322 footprint; output code 1760 = 17 Vout vs 2660 = 24 Vout (-29%)

📋 参考替代料(不在目录中)

DCM2322T72S53A0T60

✅ 直接替换
📦 Vicor ChiP DCM2322 through-hole
Same DCM2322 ChiP footprint per Vicor family; 53A0 output code (5.3 Vout) is a different output voltage, same 60 W envelope

📋 参考替代料(不在目录中)

DCM2322T50T2660T60 最大额定值与电气特性

拓扑 Isolated, regulated DC-DC converter (ZVS switching)
输入电压范围 9 Vdc to 50 Vdc
Output Voltage Nominal 24.0 V
Output Current Continuous 2.50 A
Maximum Output Power 60 W
Peak Efficiency 88.7%
Power Density 266 W/in³
Isolation Voltage 3000 Vdc
输出类型 Fixed (single output)
Safety Classification SELV (24 V nominal output)
Operating Temperature (T-Grade) -40°C to +125°C (TINT)
Operating Temperature (M-Grade) -55°C to +125°C (TINT)
Package Type Vicor ChiP through-hole module (DCM2322)
安装类型 Through Hole
RoHS 状态 Compliant

DCM2322T50T2660T60 vicor chip through-hole module (dcm2322) 引脚配置指南

DCM2322T50T2660T60(vicor chip through-hole module (dcm2322) 封装)的引脚配置。 该功率器件具有栅极、漏极和源极端子。对于无极性封装,请参阅制造商数据手册以了解确切的引脚 1 方向和封装尺寸细节。常见应用包括电源设计、电机驱动和负载开关。

DCM2322T50T2660T60 的 vicor chip through-hole module (dcm2322) 封装引脚图

暂无详细引脚数据: DCM2322T50T2660T60.

请参阅 数据手册 以查看完整引脚配置。

典型应用

DCM2322T50T2660T60 适用于 6 应用s: Industrial 24 V Bus Power System, Railway Auxiliary Power, Factory Automation PLC Power, Distributed 24 V Power for Edge Computing, Aerospace Avionics Subsystems, Medical and Test Equipment Power.

🏭

Industrial 24 V Bus Power System

The DCM2322T50T2660T60 is purpose-built for 24 V industrial bus systems where the input can vary between 9 V and 50 Vdc depending on battery state and bus topology. Its 60 W continuous (24 V at 2.50 A) output matches the typical sensor, PLC I/O, and small-motor drive loads found on factory floors. The 3000 Vdc isolation breaks ground loops between upstream bus power and downstream point-of-load converters. Designers place the module on a PCB copper pour for thermal dissipation and feed it directly from a 24 V or 36/48 V industrial bus.

🚂

Railway Auxiliary Power

The DCM2322T50T2660T60's 9-50 Vdc input range covers the 24 V, 36 V, and 48 V battery systems used in railway rolling stock and trackside signalling equipment. The 88.7% peak efficiency and ZVS topology keep conducted emissions low, easing EMC compliance for rail electronics. The 24 V SELV output can feed downstream cabin lighting controllers, door actuators, and passenger information displays. The 3000 Vdc isolation barrier is suitable for reinforced isolation between the traction bus and SELV logic circuits.

⚙️

Factory Automation PLC Power

The DCM2322T50T2660T60 delivers the 24 V, 60 W output required by PLC CPUs, I/O racks, and HMI panels without needing an additional 5 V or 12 V supply. The 9-50 Vdc input lets the same module accept power from 24 V factory bus, 48 V battery backup, or 12 V intermediate rails, reducing BOM variants for machine builders. The 266 W/in³ power density and ChiP package free significant PCB area for I/O channels. Designers often pair the DCM2322T50T2660T60 with a downstream LDO to derive 3.3 V logic rails.

🖥️

Distributed 24 V Power for Edge Computing

The DCM2322T50T2660T60 provides 24 V at 60 W to edge computing nodes such as industrial gateways, machine-vision processors, and remote I/O concentrators. Its wide 9-50 V input accepts power from 12 V solar battery systems, 24 V vehicle systems, and 48 V telecom-style racks. The 88.7% efficiency reduces thermal load in sealed edge enclosures with no fan cooling. The 3000 Vdc isolation protects downstream low-voltage digital logic from upstream surge transients on long cable runs.

✈️

Aerospace Avionics Subsystems

The DCM2322T50T2660T60M60 (M-Grade) variant supports aerospace and defense subsystems where the internal operating temperature extends to -55°C. The 24 V SELV output can power displays, FMS subsystems, and non-critical avionics buses from a 28 V aircraft supply. The 3000 Vdc isolation and ZVS switching yield low EMI footprint for sensitive RF and sensor circuits. Engineers typically derate output to 80% (48 W) in aerospace applications to extend component life.

💊

Medical and Test Equipment Power

The DCM2322T50T2660T60's 3000 Vdc isolation provides the patient-isolation margin needed in medical device subsystems that interface with 24 V supply rails. The 24 V SELV output is convenient for powering precision analog front-ends, motor-control drivers, and display backlights from a single module. The 88.7% efficiency and ZVS topology minimize conducted noise, preserving the noise floor of sensitive measurement circuits. The ChiP package simplifies medical-grade PCB layouts with a clean, repeatable footprint.

推荐产品汇总

DCM2322T50T3160T60 Same family, 31.5 Vout for higher-voltage buses 用于: Industrial 24 V Bus Power System, Distributed 24 V Power for Edge Computing, Medical and Test Equipment Power DCM2322T50T1760M60 Same family, 17 Vout for lower-voltage POL conversion 用于: Industrial 24 V Bus Power System, Factory Automation PLC Power, Aerospace Avionics Subsystems DCM2322T50T2660M60 M-Grade variant for extreme cold-start railway conditions 用于: Railway Auxiliary Power, Distributed 24 V Power for Edge Computing, Medical and Test Equipment Power DCM2322T72S53A0T60 Alternate DCM2322 family member in same ChiP footprint 用于: Railway Auxiliary Power, Aerospace Avionics Subsystems DCM2322T72S2660T60 T-Grade family member with 72V input range 用于: Factory Automation PLC Power
What is the input voltage range of DCM2322T50T2660T60?
The DCM2322T50T2660T60 accepts a wide 9 Vdc to 50 Vdc input voltage range, enabling one module to cover 12 V, 24 V, and 36/48 V battery or bus systems. According to the Vicor DCM datasheet for the DCM2322x50 family, internal temperature TINT is specified at 25°C for nominal parametric values, with boldface specs applying over the -40°C to +125°C T-Grade range. This wide Vin range is one of the primary reasons designers choose the DCM2322 platform.
What is the output voltage and current of DCM2322T50T2660T60?
The DCM2322T50T2660T60 provides a fixed 24 V nominal output at up to 2.50 A continuous, delivering up to 60 W of isolated, regulated power. The output is SELV (Safety Extra Low Voltage) classified when integrated per Vicor guidance. According to the Vicor DCM datasheet, the 24 Vout variant is specified for the 2660 output code, with 3000 Vdc isolation between input and output.
Where can I buy DCM2322T50T2660T60?
The DCM2322T50T2660T60 is in stock at DigiKey, Mouser, and authorized Vicor distributors such as Sourcengine and JAK Electronics. As of 2026-10-14, the qty-1 unit price on distributor channels is approximately $141.29. Vicor also sells direct through vicorpower.com for higher quantities and custom configurations.
What is the lead time for DCM2322T50T2660T60?
Vicor ChiP modules typically ship from authorized stock within 2-4 weeks, with factory-direct orders of larger quantities running 6-10 weeks. As of 2026-10-14, DigiKey lists the DCM2322T50T2660T60 as shipping immediately from inventory. For volume orders beyond distributor stock, contact Vicor directly for a quote with current lead times.
What is the efficiency of DCM2322T50T2660T60?
The DCM2322T50T2660T60 achieves 88.7% peak efficiency across all line, trim, and load conditions. According to the Vicor DCM datasheet, this peak is reached within the rated operating region; efficiency is lower at extreme Vin-Vout differentials and at very light loads. The ZVS topology minimizes switching losses, which is what enables the 88.7% figure in a small ChiP footprint.
What is the isolation voltage of DCM2322T50T2660T60?
The DCM2322T50T2660T60 provides 3000 Vdc galvanic isolation between input and output. According to the Vicor DCM datasheet, this isolation rating makes the module suitable for industrial control systems where the 24 Vout rail must float relative to the input bus. The isolation barrier also breaks ground loops that would otherwise introduce noise into precision analog circuits.
DCM2322T50T2660T60 vs DCM2322T50T3160T60 - what is the difference?
Both parts share the DCM2322 ChiP package, 9-50 V input range, and 2.50 A continuous rating; the 3160 output code produces 31.5 Vout instead of the 26 (24 V) code in this part number. Per the Vicor DCM datasheet family, the 2660 and 3160 variants differ only in output voltage setpoint - everything else (60 W, 88.7% efficiency, 3000 Vdc isolation) is identical. Choose 2660 for 24 V industrial bus systems; choose 3160 for slightly higher voltage rails.
What is the difference between DCM2322T50T2660T60 (T-Grade) and DCM2322T50T2660M60 (M-Grade)?
The DCM2322T50T2660T60 is T-Grade with internal operating temperature -40°C to +125°C; the M-Grade M60 variant extends the low-end to -55°C to +125°C for harsher military and aerospace environments. According to Vicor's grade definitions, M-Grade undergoes additional screening and is priced higher. Pinout and electrical specifications are otherwise identical - M-Grade is a true drop-in for the same PCB footprint when extreme cold is required.
Can I replace DCM2322T50T2660T60 with a non-Vicor module?
Cross-brand drop-in replacements for the DCM2322T50T2660T60 are not generally available because the Vicor ChiP package is proprietary. Generic 60 W 24 Vout isolated DC-DC modules from other manufacturers require a different PCB footprint, even if electrical specifications match. For pin-compatible alternatives, choose a variant within the same DCM2322 family from Vicor - see the alternatives section on this page for matched parts.
What is the best Vicor drop-in replacement for DCM2322T50T2660T60?
The DCM2322T50T1760M60 is the closest Vicor drop-in: same ChiP footprint, same 9-50 V input and 60 W rating, with the 1760 code delivering a different output voltage setpoint. Per the Vicor DCM datasheet family, only a part with a matching output code (2660) is functionally identical; output-voltage variants require a re-characterization of the downstream design. M-Grade screening is a true drop-in for T-Grade temperature applications.
What is the package and footprint of DCM2322T50T2660T60?
The DCM2322T50T2660T60 uses Vicor's ChiP (Converter housed in Package) through-hole module format with a standardized DCM2322 land pattern. According to the Vicor DCM datasheet, the module exposes +IN/-IN power pins and +OUT/-OUT power pins plus control/trim pins. The ChiP is intended to be mounted on a PCB with appropriate thermal copper and may require a heatsink at full 60 W load.
Where to download DCM2322T50T2660T60 datasheet PDF?
The official DCM2322T50T2660T60 datasheet PDF is hosted by Vicor at https://www.vicorpower.com/documents/datasheets/DCM2322x50T2660y6z_ds.pdf. According to the manufacturer datasheet listing, this PDF covers the full DCM2322x50T2660 family. Mirror copies are also available through icdirectory.com, alldatasheet.com, and chipdig.com, but the manufacturer-hosted PDF is the authoritative source.
What are the key specifications of DCM2322T50T2660T60 that engineers should know?
Three headline specifications define the DCM2322T50T2660T60 for engineering use: 9-50 Vdc wide input range, 60 W (24 V at 2.50 A) output, and 3000 Vdc isolation. Supporting specs include 88.7% peak efficiency, 266 W/in³ power density, and ZVS high-frequency switching. Per the Vicor DCM datasheet, the SELV 24 Vout compliance and T-Grade -40°C to +125°C TINT rating make the part broadly usable in industrial environments.
Is DCM2322T50T2660T60 suitable for railway applications?
The DCM2322T50T2660T60 is well suited to railway auxiliary power because its 9-50 Vdc input covers the 24 V, 36 V, and 48 V battery systems common in rolling stock. The 3000 Vdc isolation meets the reinforced isolation requirements for traction and signalling subsystems. According to the Vicor DCM datasheet, the wide input range also accommodates voltage transients on the rail bus, which can swing beyond the nominal range during load dumps.
What is the Vicor equivalent for DCM2322T50T2660T60 with a different output voltage?
The same DCM2322 ChiP family includes 2660 (24 Vout, this part), 3160 (31.5 Vout), and 1760 (17 Vout) output codes from the same 9-50 V input. Per the Vicor DCM datasheet family, only the output code (1760/2660/3160) distinguishes these variants - input range, power, efficiency, and isolation are identical. Choose 3160 for higher downstream rails, or 1760 for 15-17 V point-of-load converters.

工程参考数据: DCM2322T50T2660T60 ——对比、设计指导和合规信息。

选型指南

Choose the DCM2322T50T2660T60 when you need 24 V at 60 W from a wide 9-50 Vdc input with reinforced isolation for an industrial bus, factory automation PLC, or railway auxiliary rail. Pick the DCM2322T50T2660M60 (M-Grade) variant only if the internal operating temperature must reach -55°C; T-Grade covers most industrial use cases. Choose DCM2322T50T3160T60 if your downstream system needs 31.5 Vout, or DCM2322T50T1760M60 for a 17 Vout rail. Cross-brand drop-in replacements are not generally available - Vicor's ChiP package is proprietary, so functionally similar third-party modules require a different PCB footprint.

与替代料对比

参数 本产品 DCM2322T50T2660M60 DCM2322T72S2660T60 DCM2322T50T3160T60 DCM2322T50T1760M60 DCM2322T72S53A0T60
Brand Vicor Vicor Vicor Vicor Vicor Vicor
Package Vicor ChiP DCM2322 through-hole Vicor ChiP DCM2322 through-hole (same) Vicor ChiP DCM2322 through-hole (same) Vicor ChiP DCM2322 through-hole (same) Vicor ChiP DCM2322 through-hole (same) Vicor ChiP DCM2322 through-hole (same)
Output Voltage Nominal 24.0 V 24.0 V 24.0 V 31.5 V 17.0 V 5.3 V
Output Current Continuous 2.50 A 2.50 A 2.50 A 2.50 A 2.50 A 2.50 A
Output Power 60 W 60 W 60 W 60 W 60 W 60 W
Isolation Voltage 3000 Vdc 3000 Vdc 3000 Vdc 3000 Vdc 3000 Vdc 3000 Vdc
Operating Temperature Grade T-Grade (-40°C to +125°C TINT) M-Grade (-55°C to +125°C TINT) T-Grade (-40°C to +125°C TINT) T-Grade (-40°C to +125°C TINT) M-Grade (-55°C to +125°C TINT) T-Grade (-40°C to +125°C TINT)

关键差异点

  • Higher continuous output power than competing 24 Vout isolated modules (对比 DCM2322T72S53A0T60 (5.3 Vout variant))
  • ZVS topology achieves 88.7% peak efficiency in a small ChiP footprint (对比 DCM2322T50T3160T60 (31.5 Vout variant))
  • T-Grade and M-Grade variants share identical ChiP footprint and pinout (对比 DCM2322T50T1760M60 (17 Vout, M-Grade))

设计说明

Use a Kelvin connection for the -IN pin and route the -IN trace as a dedicated reference to the control pins. According to the Vicor DCM datasheet, voltage drop on the -IN connection degrades regulation accuracy and can cause the module to misread control signals. Place the input bulk capacitor as close as practical to the +IN/-IN pins and use a low-impedance ground return from the module to the source.

At full 60 W load the DCM2322T50T2660T60 dissipates an estimated 7.5 W at 88.7% efficiency; the ChiP package must be thermally bonded to the PCB copper pour or mounted on a heatsink. Worst-case thermal stress occurs at minimum Vin (9 V) where the converter draws the most input current. Use a copper pour of at least 1 square inch per side and, if natural convection is insufficient, add forced-air cooling to keep TINT below 125°C.

Add a fuse or PTC on the +IN line rated for the worst-case input current (60 W / 9 V = 6.7 A, plus margin). The DCM2322T50T2660T60 does not include input OVP, so consider a TVS or input EMI filter ahead of the module for hot-plug or transients. Verify output-side capacitance does not exceed the maximum capacitive load specified for the 24 Vout variant to avoid startup overshoot.

合规信息

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
无铅
Yes
无卤
Unknown
冲突矿物
Compliant

RoHS and REACH compliant per Vicor product page. M-Grade (M60 suffix) variants are screened for MIL-STD temperature ranges but are not AEC-Q100 qualified.

数据核验日期: 2026-10-14 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

DCM2322T50T2660T60 DCM2322T50T2660T60 datasheet Vicor DCM 60W 24V isolated DC-DC Vicor DCM2322 ChiP module pinout DCM2322 9-50V input isolated converter DCM2322 industrial 24V bus power DCM2322T50T2660T60 vs DCM2322T50T3160T60 DCM2322T50T2660T60 drop-in replacement buy Vicor DCM2322T50T2660T60 where to download DCM2322 datasheet PDF Vicor 60W 3000 Vdc isolated converter DCM2322 ZVS ZVS high frequency switching

相关元器件 & 术语

Vicor DCM2322T50T2660T60 DCM2322T50T2660M60 DCM2322T50T3160T60 DCM2322T50T1760M60 DCM2322T72S2660T60 DCM2322T72S53A0T60 DC-DC converter isolated DC-DC converter ZVS SELV ChiP package Vicor ChiP industrial 24V bus 3000 Vdc isolation 88.7% peak efficiency 266 W/in³ power density M-Grade T-Grade Kelvin connection AEC-Q100 RoHS REACH
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情