Texas Instruments

INA101KUE4 - High-Accuracy Instrumentation Amplifier | TI

料号: INA101KUE4 ✓ 量产中
250 uV Vdss 16-pin SOIC, 7.50 mm width Package
最小起订量: 1 |

INA101KUE4 概述

The Texas Instruments INA101KUE4 is a high-accuracy instrumentation amplifier with three internal amplifiers, a 300 kHz bandwidth, 250 uV input offset voltage, and single-ended output capability, packaged in a 16-pin SOIC. It is designed for precision differential-signal conditioning where high input impedance, common-mode rejection, and adjustable gain are important. The device is suitable for sensor interfaces, industrial measurement systems, medical instrumentation, and laboratory equipment.

An instrumentation amplifier is a specialized amplifier that combines differential input, high input impedance, and precise gain-setting behavior in one integrated circuit. Its functional position is signal conditioning within the broader amplifier IC category: sensor output -> instrumentation amplifier -> ADC or signal-processing circuit. Unlike a general-purpose operational amplifier, an instrumentation amplifier is optimized for measuring small differential signals riding on a larger common-mode voltage, which helps preserve signal integrity in precision measurement systems.

The INA101KUE4 uses a three-amplifier architecture to provide high input impedance and accurate differential gain. Its stated bandwidth is 300 kHz, while the input offset voltage is 250 uV. The manufacturer describes the device as a high-accuracy instrumentation amplifier, and its single-ended amplifier output supports conversion of a differential input into a ground-referenced signal for downstream data conversion. An external resistor network sets the closed-loop gain according to the manufacturer's recommended circuit.

The main design trade-off is bandwidth versus precision. A 300 kHz bandwidth is suitable for many pressure, temperature, bridge-sensor, and general industrial measurement signals, but it is not intended for high-frequency waveform systems requiring megahertz-class signal bandwidth. Input common-mode range, output swing, supply voltage, and gain-error limits must be checked against the actual sensor output and the selected supply rails before the circuit is finalized.

Typical uses include low-level bridge and strain-gauge conditioning, medical sensor instrumentation, current-shunt measurement, precision current sensing, laboratory test equipment, and industrial process-control modules. In each case, the differential input architecture helps reject common-mode disturbance when the measured signal is small relative to the surrounding voltage range.

Place the gain-setting resistor directly at the amplifier pins and use a quiet reference or regulated supply for analog circuitry. Keep input and feedback traces short, use a solid ground plane, and decouple each supply rail close to the device. Check input and output common-mode limits across temperature, because operation near either range boundary can reduce usable signal swing even when the supply voltage itself is adequate.

This product page combines the INA101KUE4 device identity, verified package and performance details, sourcing information, replacement guidance, and practical circuit-design notes. It is intended to help engineers compare the exact INA101KUE4 ordering code against compatible alternatives while recognizing that instrumentation-amplifier pin compatibility must be confirmed at the individual-pin level.

直接替换替代料: INA101KUE4 ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: INA101KUE4 (相同外形与封装尺寸) ——差异在于 Package, Input Offset Voltage, Number of Circuits, Bandwidth, Gain Setting.

Texas Instruments
Package: 16-SOIC (DW / SOL-16)
Input Offset Voltage: 25 uV max
Number of Circuits: 1
对比 INA101KUE4 →
Texas Instruments
Package: 16-pin SOIC (DW)
Input Offset Voltage: 25 uV max
Number of Circuits: 1
Texas Instruments
Package: 16-SOIC
Input Offset Voltage: 250 µV maximum
对比 INA101KUE4 →

INA101KU

✅ 直接替换
Texas Instruments
📦 SOIC-14
Instrumentation Amplifier · 1 · 3-amplifier (three op amp) architecture · 25 uV max · 0.25 uV/C max · 0.002% max · 13 nV/Hz · High CMR at 60 Hz

联系询价

查看数据手册 →

INA103KU

✅ 直接替换
Texas Instruments
📦 SOIC-16
Monolithic instrumentation amplifier · 1 circuit · 16-SOIC · Surface mount · 9 V to 25 V · 6 MHz · 15 V/s · 250 µV maximum

联系询价

查看数据手册 →

INA105KU/2K5

✅ 直接替换
📦 SOIC-16
The cross-reference result identifies INA105KU/2K5 as a related candidate, while the available excerpt does not quantify its pin-level or electrical differences from INA101KUE4.

📋 参考替代料(不在目录中)

INA101KUE4 最大额定值与电气特性

Product Type High-accuracy instrumentation amplifier
Number of Amplifiers 3 internal amplifiers
Number of Circuits 1 circuit
Input Offset Voltage 250 uV
Bandwidth 300 kHz
输出类型 Single-ended
封装 16-pin SOIC, 7.50 mm width
Terminal Count 16 terminals
Terminal Form Gull wing
Package Shape Rectangular
Package Code SOP
安装方式 Surface mount
Temperature Grade Commercial

INA101KUE4 sop 引脚配置指南

INA101KUE4(sop 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。

INA101KUE4 的 sop 封装引脚图

暂无详细引脚数据: INA101KUE4.

请参阅 数据手册 以查看完整引脚配置。

典型应用

INA101KUE4 适用于 6 应用s: Bridge and Strain-Gauge Measurement, Medical Sensor Instrumentation, Precision Current-Shunt Monitoring, Industrial Process-Control Sensing, Laboratory Measurement Equipment, Portable Battery-Powered Instrumentation.

🏭

Bridge and Strain-Gauge Measurement

The INA101KUE4 is well suited to low-level differential sensing from resistive bridges, strain gauges, and pressure elements because its instrumentation-amplifier architecture accepts a differential input while rejecting common-mode voltage. The 250 uV input offset specification is important when the bridge output is small, and the 300 kHz bandwidth is sufficient for many static and moderately dynamic mechanical measurements. Place the gain resistor close to the device, establish the sensor-return path cleanly, and verify that bridge excitation and signal common-mode voltage remain within the manufacturer limits.

💊

Medical Sensor Instrumentation

The INA101KUE4 can condition low-amplitude differential signals from medical and biosensing front ends where preserving the sensor's small output is important. Its 250 uV input offset specification helps limit error relative to microvolt- and millivolt-level sensor outputs, while the 300 kHz bandwidth covers many physiological and diagnostic signals below that limit. Shield sensitive input traces, isolate digital clocks and switching regulators, and confirm suitability for the required medical-grade qualification and operating-temperature requirements.

⚡

Precision Current-Shunt Monitoring

The INA101KUE4 is appropriate for measuring the differential voltage generated across a current shunt in power supplies, motor controls, and battery systems. The differential input rejects the common-mode voltage present across a low-ohm shunt, while the instrumentation-amplifier configuration simplifies gain control. The 300 kHz bandwidth is useful for ripple and load-current analysis but does not extend to fast switching transients. Select a shunt resistance that keeps the signal within the input common-mode range and use Kelvin routing for best accuracy.

🏭

Industrial Process-Control Sensing

The INA101KUE4 can amplify differential outputs from industrial pressure, temperature, and level sensors before conversion by an ADC. Its 300 kHz bandwidth handles process-control signals without requiring a high-speed amplifier, and the three-amplifier architecture reduces the need for a carefully matched discrete gain stage. In factory equipment, maintain a separate analog ground return for the sensor and amplifier, keep relay and motor currents out of the reference path, and check transient protection at long cable interfaces.

🔧

Laboratory Measurement Equipment

The INA101KUE4 supports laboratory instruments that measure small differential voltages with high input impedance, including bench meters, programmable sources, and precision test fixtures. The 250 uV input offset specification helps establish accuracy for low-level measurements, while adjustable gain permits scaling for different transducer sensitivities. Place the gain resistor close to the IC, use short shielded input routing, decouple the supply rails locally, and account for output headroom when selecting the gain and operating voltage.

📱

Portable Battery-Powered Instrumentation

The INA101KUE4 is suitable for portable measurement modules that must combine high input impedance with compact analog conditioning. Its 16-pin SOIC package supports conventional surface-mount assembly, and the 300 kHz bandwidth covers many sensor outputs without demanding a high-speed analog design. In a battery-powered system, confirm the supported supply range and supply current in the manufacturer datasheet, use a low-noise analog supply, and place bypass capacitors immediately across the supply pins to limit switching-induced noise.

推荐产品汇总

ADS1246 Delta-sigma ADC for precision bridge measurements 用于: Bridge and Strain-Gauge Measurement, Medical Sensor Instrumentation, Industrial Process-Control Sensing, Laboratory Measurement Equipment, Portable Battery-Powered Instrumentation OPA333 Low-power precision operational amplifier for auxiliary signal conditioning 用于: Bridge and Strain-Gauge Measurement, Medical Sensor Instrumentation, Laboratory Measurement Equipment LM2904PWR Texas Instruments 用于: Precision Current-Shunt Monitoring, Industrial Process-Control Sensing, Portable Battery-Powered Instrumentation LM324NSR Texas Instruments 用于: Precision Current-Shunt Monitoring
What is the INA101KUE4?
The INA101KUE4 is a Texas Instruments high-accuracy, single-circuit instrumentation amplifier with three internal amplifiers, a 300 kHz bandwidth, a 250 uV input offset voltage, and a single-ended output. According to the manufacturer datasheet, the device is intended for differential-signal conditioning where common-mode rejection, high input impedance, and externally controlled gain are important. The exact ordering code is supplied in a 16-pin SOIC package.
Where can I download the INA101KUE4 datasheet PDF?
The INA101KUE4 datasheet PDF is available from Texas Instruments through the INA101 product documentation. The document describes the instrumentation-amplifier architecture, electrical characteristics, pin configuration, gain equation, typical application circuits, and ordering information. When creating a PCB or replacing the device, consult the pin-description table in the manufacturer datasheet and compare every connection on the 16-pin footprint.
What are the key specifications of INA101KUE4?
The key INA101KUE4 specifications are a 300 kHz bandwidth, 250 uV input offset voltage, three internal amplifiers, one amplifier circuit, and a single-ended output. Texas Instruments packages the component in a 16-terminal gull-wing SOIC with a 7.50 mm body width. These details make it suitable for low-level differential sensors and industrial measurement circuits, subject to the supply, common-mode, and output-swing limits in the datasheet.
What applications suit the INA101KUE4?
The INA101KUE4 suits bridge sensors, strain gauges, medical sensor interfaces, current-shunt monitoring, laboratory instrumentation, and industrial process-control circuits. Its 300 kHz bandwidth is appropriate for many low- and medium-frequency measurement signals, while the 250 uV input offset specification is relevant to low-level differential measurements. The signal source must remain inside the device's input common-mode range, and the output must retain adequate swing.
Is INA101KUE4 pin compatible with INA101KU?
The INA101KUE4 and INA101KU are related ordering codes, but the comparison result identifies INA101KU/1K as a 14-pin SOIC while the INA101KUE4 is a 16-pin SOIC. They therefore should not be treated as drop-in equivalents based on package family alone. Check the INA101 family datasheet for the complete pin lists and verify supply voltage, gain architecture, and missing-pin functions before considering any board change.
What is the difference between INA101KUE4 and INA103KU?
The INA101KUE4 is identified as a 16-pin SOIC, while a dedicated comparison page places INA103KU in the same broader instrumentation-amplifier category. The available comparison excerpt does not establish every pin function or quantitative electrical difference, so absolute drop-in compatibility cannot be confirmed from that page alone. Use the Texas Instruments pin descriptions and ordering tables for both devices, then verify supply range, gain setting, input common-mode range, and output configuration.
What can replace INA101KUE4?
A valid drop-in replacement for INA101KUE4 must match its 16-pin footprint, pin functions, supply range, gain-setting method, input and output common-mode limits, bandwidth, and error characteristics. The cross-reference material identifies INA103KU, INA105KU/2K5, INA101HPG4, and INA101KU/1K as related candidates, but it does not prove that all are pin-to-pin compatible. Do not substitute any of them without comparing the manufacturer pin tables.
What is the best drop-in replacement for INA101KUE4?
The best drop-in replacement is the device that reproduces all 16 INA101KUE4 connections and remains within the original circuit's electrical limits; the available comparison results do not establish one universal substitute. INA101KU/1K is a 14-pin part and is therefore not footprint-compatible without qualification. Have the candidate's manufacturer datasheet checked pin by pin, including the external gain resistor, supply pins, reference connection, and output.
When should I choose INA101KUE4 over a general-purpose op amp?
Choose the INA101KUE4 when the source is a low-level differential signal and the circuit needs high input impedance plus accurate differential gain without building a matched resistor network from multiple amplifiers. Its three-amplifier instrumentation-amplifier architecture and 300 kHz bandwidth are better aligned with bridge and shunt measurements than a single general-purpose op amp. A discrete or single-amplifier design may be preferable when the source impedance is known, low, and gain requirements are modest.
How do I set the gain of INA101KUE4?
The INA101KUE4 uses an external gain-setting resistor to establish its closed-loop differential gain. Use the gain equation and recommended resistor value in the manufacturer datasheet, and place the resistor close to the gain terminals to minimize parasitic resistance and noise. Also verify that the selected gain keeps the amplifier within its input and output common-mode limits at the actual supply voltage.
What design considerations matter for INA101KUE4 power and thermal performance?
The INA101KUE4 is an analog signal-conditioning IC rather than a power device, so thermal design centers on total supply dissipation and the PCB's copper area. Estimate dissipation from the actual supply voltage, output voltage, and quiescent or load current, then confirm the junction-temperature limit in the manufacturer datasheet. Use a ground plane and local supply bypassing, but avoid placing noisy digital return currents through the analog input reference path.
Where can I buy INA101KUE4 and check its lead time?
Use the Request a Quote form on this page to request the INA101KUE4, current lead time, and minimum order quantity from XAIPART. The device is shown in a 16-pin SOIC package, but package identification alone does not guarantee immediate stock. Supply status can change, so confirm the exact ordering code, quantity, and delivery requirements when requesting a quotation.
What is the price of INA101KUE4?
Current pricing for the INA101KUE4 is presented through the Request a Quote form on this page rather than as a static price statement. Submit the required quantity and package details to request a current quotation, including stock allocation and expected lead time. The exact MPN is INA101KUE4, so include the complete ordering suffix when requesting an assembled quotation.
Is INA101KUE4 in stock?
Inventory for INA101KUE4 should be confirmed through the Request a Quote form on this page. A distributor snippet may show stock for one moment, but availability can change without notice and may differ by quantity. Provide the required order quantity and target delivery date so the current allocation and lead-time position can be answered against the exact INA101KUE4 ordering code.
Where is the INA101KUE4 pinout located?
The INA101KUE4 pinout is located in the pin-configuration section of the Texas Instruments INA101 datasheet. The device uses a 16-pin SOIC, and the pin table identifies the differential inputs, output, supply connections, gain-setting connection, and any reference or balance-related functions. Use that table when assigning PCB tracks; do not infer the pinout from a generic 16-pin amplifier symbol or from a related 14-pin device.

工程参考数据: INA101KUE4 ——对比、设计指导和合规信息。

选型指南

Choose the INA101KUE4 for low-level differential measurements that require high input impedance, three-amplifier instrumentation behavior, adjustable gain, and a 300 kHz bandwidth. It is a strong fit for bridge sensors, strain gauges, medical sensing, shunt current measurement, laboratory instruments, and industrial process controls. Choose INA103KU only after its pin functions and electrical limits have been compared with the original design. Consider INA105KU/2K5 for its own documented gain and error characteristics after confirming board compatibility. Do not select INA101KU as a drop-in part for a 16-pin PCB because the identified package has fewer pins. For a general-purpose low-cost signal stage, an ordinary dual amplifier may be more appropriate, but it will not reproduce the integrated differential-input architecture. In every case, validate supply range, common-mode range, output swing, gain accuracy, offset, bandwidth, and exposed-versus-naked pin functions against the manufacturer datasheet.

与替代料对比

参数 本产品 INA101KU INA103KU INA105KU/2K5
Package SOIC-16 SOIC-14 SOIC-16 SOIC-16
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Product Type High-accuracy instrumentation amplifier Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier

关键差异点

  • Purpose-built differential signal conditioning (对比 LM2904PWR)
  • Defined measurement bandwidth (对比 INA103KU)
  • Single-ended precision output (对比 INA105KU/2K5)

设计说明

Place the INA101KUE4 gain-setting resistor directly across the designated gain pins and keep the loop short to reduce parasitic resistance and noise pickup. Route differential inputs as a tightly matched pair and provide a continuous ground plane beneath the analog section. Avoid switching-regulator traces, relay-driver paths, and digital clock lines beneath the amplifier and feedback nodes.

Establish the common-mode and output-voltage budget before selecting the gain. The sensor or shunt must remain inside the amplifier's input common-mode range, and the required output must retain enough headroom below the positive supply rail. Estimated: for a gain of 100 and a 10 mV differential input, the ideal output is 1 V; add input-offset and gain-error effects when sizing the signal range.

Use separate local bypass capacitors from each supply pin to the ground plane and keep them close to the device. Confirm the supported supply range, supply-current behavior, and output-swing limits in the manufacturer datasheet before choosing rail voltages. For precision measurements, power the analog section from a low-noise source and prevent high-current returns from sharing the sensitive reference path.

Do not assume that every INA-family ordering code is board-compatible. INA101KU is identified as a 14-pin SOIC, while INA101KUE4 uses 16 pins. Before replacement, compare every named pin, the external gain-resistor connection, reference implementation, supply range, and output function. A matching package body alone does not establish pin-to-pin compatibility.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

The commercial temperature grade is identified in the product listing. RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals status require confirmation from the manufacturer product documentation.

数据核验日期: 2026-11-14 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

INA101KUE4 datasheet INA101KUE4 pinout INA101KUE4 datasheet pdf INA101KUE4 equivalent INA101KUE4 replacement INA101KUE4 vs INA103KU INA101KUE4 16 pin SOIC INA101KUE4 300 kHz bandwidth INA101KUE4 250 uV offset INA101KUE4 price INA101KUE4 stock Texas Instruments INA101KUE4

相关元器件 & 术语

Texas Instruments INA101KUE4 INA101KU INA103KU INA105KU/2K5 INA101HPG4 instrumentation amplifier amplifier IC signal-conditioning IC semiconductor differential input single-ended output input offset voltage common-mode rejection gain bandwidth 300 kHz bandwidth 250 uV input offset voltage bridge sensor strain gauge medical sensor interface current-shunt measurement SOIC-16 SOIC package family surface mount
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情