INA101KUE4 - High-Accuracy Instrumentation Amplifier | TI
部品番号: INA101KUE4 ✓ 生産中INA101KUE4 概要
An instrumentation amplifier is a specialized amplifier that combines differential input, high input impedance, and precise gain-setting behavior in one integrated circuit. Its functional position is signal conditioning within the broader amplifier IC category: sensor output -> instrumentation amplifier -> ADC or signal-processing circuit. Unlike a general-purpose operational amplifier, an instrumentation amplifier is optimized for measuring small differential signals riding on a larger common-mode voltage, which helps preserve signal integrity in precision measurement systems.
The INA101KUE4 uses a three-amplifier architecture to provide high input impedance and accurate differential gain. Its stated bandwidth is 300 kHz, while the input offset voltage is 250 uV. The manufacturer describes the device as a high-accuracy instrumentation amplifier, and its single-ended amplifier output supports conversion of a differential input into a ground-referenced signal for downstream data conversion. An external resistor network sets the closed-loop gain according to the manufacturer's recommended circuit.
The main design trade-off is bandwidth versus precision. A 300 kHz bandwidth is suitable for many pressure, temperature, bridge-sensor, and general industrial measurement signals, but it is not intended for high-frequency waveform systems requiring megahertz-class signal bandwidth. Input common-mode range, output swing, supply voltage, and gain-error limits must be checked against the actual sensor output and the selected supply rails before the circuit is finalized.
Typical uses include low-level bridge and strain-gauge conditioning, medical sensor instrumentation, current-shunt measurement, precision current sensing, laboratory test equipment, and industrial process-control modules. In each case, the differential input architecture helps reject common-mode disturbance when the measured signal is small relative to the surrounding voltage range.
Place the gain-setting resistor directly at the amplifier pins and use a quiet reference or regulated supply for analog circuitry. Keep input and feedback traces short, use a solid ground plane, and decouple each supply rail close to the device. Check input and output common-mode limits across temperature, because operation near either range boundary can reduce usable signal swing even when the supply voltage itself is adequate.
This product page combines the INA101KUE4 device identity, verified package and performance details, sourcing information, replacement guidance, and practical circuit-design notes. It is intended to help engineers compare the exact INA101KUE4 ordering code against compatible alternatives while recognizing that instrumentation-amplifier pin compatibility must be confirmed at the individual-pin level.
ドロップイン代替品: INA101KUE4 — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: INA101KUE4 (同一形状・フットプリント) — 相違点: Package, Input Offset Voltage, Number of Circuits, Bandwidth, Gain Setting.
INA101KU
✅ ドロップイン価格はお問い合わせください
データシートを見る →INA103KU
✅ ドロップイン価格はお問い合わせください
データシートを見る →INA105KU/2K5
✅ ドロップイン📋 参考代替品(カタログ未掲載)
INA101KUE4 最大定格&電気的特性
| Product Type | High-accuracy instrumentation amplifier |
| Number of Amplifiers | 3 internal amplifiers |
| Number of Circuits | 1 circuit |
| Input Offset Voltage | 250 uV |
| Bandwidth | 300 kHz |
| 出力タイプ | Single-ended |
| パッケージ | 16-pin SOIC, 7.50 mm width |
| Terminal Count | 16 terminals |
| Terminal Form | Gull wing |
| Package Shape | Rectangular |
| Package Code | SOP |
| 実装スタイル | Surface mount |
| Temperature Grade | Commercial |
INA101KUE4 sop ピン配置ガイド
INA101KUE4 (sop パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: INA101KUE4.
詳細は データシート をご参照ください。
主な用途
INA101KUE4 の用途: 6 件s: Bridge and Strain-Gauge Measurement, Medical Sensor Instrumentation, Precision Current-Shunt Monitoring, Industrial Process-Control Sensing, Laboratory Measurement Equipment, Portable Battery-Powered Instrumentation.
Bridge and Strain-Gauge Measurement
The INA101KUE4 is well suited to low-level differential sensing from resistive bridges, strain gauges, and pressure elements because its instrumentation-amplifier architecture accepts a differential input while rejecting common-mode voltage. The 250 uV input offset specification is important when the bridge output is small, and the 300 kHz bandwidth is sufficient for many static and moderately dynamic mechanical measurements. Place the gain resistor close to the device, establish the sensor-return path cleanly, and verify that bridge excitation and signal common-mode voltage remain within the manufacturer limits.
おすすめ
Medical Sensor Instrumentation
The INA101KUE4 can condition low-amplitude differential signals from medical and biosensing front ends where preserving the sensor's small output is important. Its 250 uV input offset specification helps limit error relative to microvolt- and millivolt-level sensor outputs, while the 300 kHz bandwidth covers many physiological and diagnostic signals below that limit. Shield sensitive input traces, isolate digital clocks and switching regulators, and confirm suitability for the required medical-grade qualification and operating-temperature requirements.
おすすめ
Precision Current-Shunt Monitoring
The INA101KUE4 is appropriate for measuring the differential voltage generated across a current shunt in power supplies, motor controls, and battery systems. The differential input rejects the common-mode voltage present across a low-ohm shunt, while the instrumentation-amplifier configuration simplifies gain control. The 300 kHz bandwidth is useful for ripple and load-current analysis but does not extend to fast switching transients. Select a shunt resistance that keeps the signal within the input common-mode range and use Kelvin routing for best accuracy.
おすすめ
Industrial Process-Control Sensing
The INA101KUE4 can amplify differential outputs from industrial pressure, temperature, and level sensors before conversion by an ADC. Its 300 kHz bandwidth handles process-control signals without requiring a high-speed amplifier, and the three-amplifier architecture reduces the need for a carefully matched discrete gain stage. In factory equipment, maintain a separate analog ground return for the sensor and amplifier, keep relay and motor currents out of the reference path, and check transient protection at long cable interfaces.
おすすめ
Laboratory Measurement Equipment
The INA101KUE4 supports laboratory instruments that measure small differential voltages with high input impedance, including bench meters, programmable sources, and precision test fixtures. The 250 uV input offset specification helps establish accuracy for low-level measurements, while adjustable gain permits scaling for different transducer sensitivities. Place the gain resistor close to the IC, use short shielded input routing, decouple the supply rails locally, and account for output headroom when selecting the gain and operating voltage.
おすすめ
Portable Battery-Powered Instrumentation
The INA101KUE4 is suitable for portable measurement modules that must combine high input impedance with compact analog conditioning. Its 16-pin SOIC package supports conventional surface-mount assembly, and the 300 kHz bandwidth covers many sensor outputs without demanding a high-speed analog design. In a battery-powered system, confirm the supported supply range and supply current in the manufacturer datasheet, use a low-noise analog supply, and place bypass capacitors immediately across the supply pins to limit switching-induced noise.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: INA101KUE4 — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | INA101KU | INA103KU | INA105KU/2K5 |
|---|---|---|---|---|
| Package | SOIC-16 | SOIC-14 | SOIC-16 | SOIC-16 |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Product Type | High-accuracy instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier |
主な差別化要因
- Purpose-built differential signal conditioning (vs LM2904PWR)
- Defined measurement bandwidth (vs INA103KU)
- Single-ended precision output (vs INA105KU/2K5)
設計ノート
Place the INA101KUE4 gain-setting resistor directly across the designated gain pins and keep the loop short to reduce parasitic resistance and noise pickup. Route differential inputs as a tightly matched pair and provide a continuous ground plane beneath the analog section. Avoid switching-regulator traces, relay-driver paths, and digital clock lines beneath the amplifier and feedback nodes.
Establish the common-mode and output-voltage budget before selecting the gain. The sensor or shunt must remain inside the amplifier's input common-mode range, and the required output must retain enough headroom below the positive supply rail. Estimated: for a gain of 100 and a 10 mV differential input, the ideal output is 1 V; add input-offset and gain-error effects when sizing the signal range.
Use separate local bypass capacitors from each supply pin to the ground plane and keep them close to the device. Confirm the supported supply range, supply-current behavior, and output-swing limits in the manufacturer datasheet before choosing rail voltages. For precision measurements, power the analog section from a low-noise source and prevent high-current returns from sharing the sensitive reference path.
Do not assume that every INA-family ordering code is board-compatible. INA101KU is identified as a 14-pin SOIC, while INA101KUE4 uses 16 pins. Before replacement, compare every named pin, the external gain-resistor connection, reference implementation, supply range, and output function. A matching package body alone does not establish pin-to-pin compatibility.
コンプライアンス情報
The commercial temperature grade is identified in the product listing. RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals status require confirmation from the manufacturer product documentation.