MAX3232ECUP+ - 1Mbps RS-232 Transceiver | Analog Devices
料号: MAX3232ECUP+ ✓ 量产中MAX3232ECUP+ 概述
A true RS-232 transceiver is an interface IC that converts logic-level UART signals into RS-232 bipolar levels and converts incoming RS-232 signals back into CMOS-compatible logic. Within the interface hierarchy, the MAX3232ECUP+ belongs to the RS-232 transceiver class, which is part of the broader line-driver and line-receiver family within interface ICs. Its internal dual charge pump supports the voltage swings required for true RS-232 communication.
Key features include operation from 3.0 V to 5.5 V, data rates up to 1 Mbps, ±15 kV ESD protection, and a supply current as low as 10 nA. Two transmit channels and two receive channels support full-duplex serial links. The E suffix identifies the enhanced ESD-protected version, while the UP package code corresponds to the 20-pin TSSOP used by this ordering variant.
Technically, the device combines a dual charge-pump circuit with four small charge-pump capacitors, two line drivers, and two line receivers. The charge pump develops positive and negative voltage rails needed by the transmitter outputs, allowing true RS-232 operation from a single low-voltage supply. Receiver inputs provide the electrical boundary between the ±RS-232 signal environment and a host UART operating at CMOS logic levels.
Typical uses include industrial serial consoles, data-acquisition equipment, point-of-sale systems, instrumentation, and embedded control boards. The 1 Mbps capability is useful for links requiring faster transfers than conventional low-speed serial ports, while the 3.0 V minimum supply supports modern 3.3 V systems. For 5 V systems, the same part operates within its stated upper supply limit.
PCB design should place the charge-pump capacitors close to their associated pins and provide a continuous ground return from the interface connector. Keep RS-232 traces away from sensitive analog or high-speed digital nets, use appropriate surge and ESD protection for exposed cables, and validate the external charge-pump capacitor values against the manufacturer datasheet.
This product page combines the manufacturer specifications, package details, pricing channels, replacement analysis, and practical PCB guidance. It also distinguishes genuine same-footprint alternatives from functional substitutes, helping engineers shorten qualification and sourcing work without overlooking charge-pump, ESD, speed, or shutdown differences.
直接替换替代料: MAX3232ECUP+ ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: MAX3232ECUP+ (相同外形与封装尺寸) ——差异在于 Package, ESD Protection, Product Type, Supply Voltage Range, Maximum Data Rate.
MAX3232ECDR
✅ 直接替换联系询价
查看数据手册 →MAX3232CDBR
✅ 直接替换联系询价
查看数据手册 →MAX3232CUE+
✅ 直接替换联系询价
查看数据手册 →MAX3232EEUP+
✅ 直接替换联系询价
查看数据手册 →MAX3000EEUP+
✅ 直接替换📋 参考替代料(不在目录中)
MAX3232ECUP+ 规格参数
| Product Type | True RS-232 transceiver |
| Transceiver Configuration | 2 transmitters and 2 receivers |
| Supply Voltage Range | 3.0 V to 5.5 V |
| Maximum Data Rate | 1 Mbps |
| ESD Protection | ±15 kV |
| Low-Power Supply Current | Down to 10 nA |
| Number of Drivers | 2 |
| Number of Receivers | 2 |
| Duplex Mode | Full duplex |
| Charge Pump | Dual charge-pump circuit |
| External Charge-Pump Capacitors | 4 capacitors |
| 封装 | 20-pin TSSOP |
| 安装类型 | Surface mount |
MAX3232ECUP+ 20-pin tssop 引脚配置指南
MAX3232ECUP+(20-pin tssop 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。
暂无详细引脚数据: MAX3232ECUP+.
请参阅 数据手册 以查看完整引脚配置。
典型应用
MAX3232ECUP+ 适用于 6 应用s: Industrial Serial Console, Data Acquisition Equipment, Point-of-Sale Terminal, Embedded Instrumentation, Laboratory Test Equipment, Low-Power Communication Module.
Industrial Serial Console
The MAX3232ECUP+ is suitable for an industrial console or service port because it combines two transmitters, two receivers, operation from 3.0 V to 5.5 V, and data rates up to 1 Mbps. Its true RS-232 interface lets a 3.3 V UART communicate directly with a conventional RS-232 connector while the internal dual charge pump supplies the required bipolar signaling levels. The ±15 kV ESD-protected version adds protection for cable-connected equipment exposed to electrostatic discharge. Use the manufacturer recommended charge-pump capacitors and keep the connector-side ground return continuous to reduce noise and surge-current paths.
推荐
Data Acquisition Equipment
The MAX3232ECUP+ can interface a controller or data-acquisition module to a legacy RS-232 instrument that requires true bipolar signaling. The 1 Mbps maximum data rate supports instrument control and burst transfers, while the dual-driver, dual-receiver arrangement allows full-duplex communication over two paths. Operating from 3.0 V to 5.5 V lets the same transceiver serve 3.3 V control hardware and 5 V peripheral equipment. Place the four charge-pump capacitors close to the device, separate the RS-232 routing from sensitive measurement channels, and validate the complete cable and grounding arrangement before field deployment.
推荐
Point-of-Sale Terminal
The MAX3232ECUP+ provides a compact interface between a point-of-sale controller and an RS-232 peripheral such as a printer, scanner, or customer display. Two receive channels can support a bidirectional control link, and two transmitter channels can serve separate peripheral connections when the system requires full-duplex traffic. Its 3.0 V to 5.5 V supply range supports common embedded logic levels, while operation up to 1 Mbps allows rapid transaction data transfer. The 20-pin TSSOP package keeps the interface compact, but exposed retail equipment requires careful cable protection, ground-return design, and ESD-conscious layout.
推荐
Embedded Instrumentation
The MAX3232ECUP+ fits embedded instrumentation that must communicate with a host over RS-232 while running from a 3.3 V system rail. The low-power capability, which can reach 10 nA under applicable shutdown conditions, is useful in portable or intermittently powered test equipment. The device's true RS-232 outputs and receivers eliminate the need for external level-shifting circuitry on a conventional serial link. Use the exact suffix data sheet to confirm the operating mode, and ensure the charge-pump network follows the prescribed capacitor values and placement to avoid output ripple or startup problems.
推荐
Laboratory Test Equipment
The MAX3232ECUP+ is appropriate for laboratory instruments that exchange commands and measurement data with a computer or controller over RS-232. The 1 Mbps capability supports faster command responses and data transfers, while ±15 kV ESD protection strengthens the interface against charged cables and operator-contact events. Two transmitters and two receivers provide enough channels for full-duplex instrument communication. In precision equipment, isolate the RS-232 traces from analog inputs, maintain a low-impedance ground reference, and follow the manufacturer layout to prevent charge-pump ripple from affecting measured signals.
推荐
Low-Power Communication Module
The MAX3232ECUP+ can provide an RS-232 connection for a low-power embedded module that occasionally communicates with a service port. Its supply range includes 3.3 V operation, and the low-power rating can extend to 10 nA when the relevant shutdown state is used. The true RS-232 interface remains compatible with legacy service equipment while avoiding external negative-supply circuitry. Qualification should include checking whether the selected MAX3232E ordering code offers the required shutdown and wake behavior. Keep the interface enabled only when needed, and verify startup timing across the full system power sequence.
推荐
推荐产品汇总
工程参考数据: MAX3232ECUP+ ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | MAX3232ECDR | MAX3232CDBR | MAX3232CUE+ | MAX3232EEUP+ | MAX3000EEUP+ |
|---|---|---|---|---|---|---|
| Package | TSSOP-20 | TSSOP-20 | TSSOP-20 | TSSOP-20 | TSSOP-20 | TSSOP-20 |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
关键差异点
- Higher stated maximum data rate (对比 MAX3232CDBR)
- Enhanced ESD protection in the selected suffix (对比 MAX3232CUE+)
- Single 3.0 V to 5.5 V supply with true RS-232 signaling (对比 MAX3000EEUP+)
设计说明
Place the four external charge-pump capacitors close to their corresponding MAX3232ECUP+ pins and use the values and tolerances specified by the Analog Devices datasheet. Ceramic capacitor effective capacitance can fall substantially with DC bias, so validate the effective value rather than relying only on the printed capacitance. Keep charge-pump current loops compact and provide a low-impedance ground reference near the device. This layout discipline reduces charge-pump ripple, startup variation, and emissions that could disturb nearby circuitry.
Route RS-232 driver and receiver nets away from sensitive analog inputs, clock signals, and high-speed digital traces wherever possible. Keep the connector-side ground return continuous and short so surge and ESD currents do not pass through sensitive system ground paths. Use controlled geometry for the cable interface and avoid long parallel runs with unrelated nets. Although the device provides ±15 kV ESD protection, that rating does not replace careful placement, grounding, or external surge-protection design for long or exposed cables.
Decouple the 3.0 V to 5.5 V supply with capacitors selected according to the manufacturer layout and stability guidance. Check the exact suffix data sheet before assigning the device's shutdown pins because shutdown topology and timing can vary across MAX3232E ordering codes. When power is switched intermittently, verify that the UART remains in a defined logic state during startup and shutdown. The low-power specification of down to 10 nA applies only under its defined conditions and should not be interpreted as the active operating current.
合规信息
No definitive compliance declaration for the exact MAX3232ECUP+ ordering code appears in the retrieved manufacturer or distributor information. Confirm RoHS, REACH, lead-free, halogen-free, and conflict-minerals status using the current manufacturer product declaration before procurement.