STMicroelectronics

MPX10DP - 10kPa Differential Pressure Sensor 35mV | STMicroelectronics

料号: MPX10DP ✓ 量产中
有现货 1-3 个工作日内发货
0 mV to 35 mV at 3 V excitation Vdss 4-SIP Module Package
低至 $6.09 USD / 件
最小起订量: 1 |
价格更新于: 2026-10-15
批量定价
数量 单价 小计
1 $12.5 $12.50
10 $11.25 $112.50
100 $9.75 $975.00
500 $8.4 $4,200.00
1,000 $6.09 $6,090.00
ℹ️ 所有价格均以 USD 计价

MPX10DP 概述

The STMicroelectronics MPX10DP is a 10 kPa uncompensated silicon piezoresistive pressure sensor in a 4-SIP module with a male 0.19 inch (4.93 mm) tube port, providing a linear differential analog output of 0 mV to 35 mV at a 3 V excitation. It belongs to the legacy MPX10 series originally introduced by Motorola and now produced under both NXP Semiconductors and STMicroelectronics branding, serving as the foundational bare-die building block for higher-range MPX2010/MPX2050/MPX2100 family sensors.

A piezoresistive pressure sensor is a MEMS device in which a silicon diaphragm with implanted strain gauges changes its Wheatstone-bridge resistance in proportion to applied differential pressure. The MPX10DP operates as a bridge transducer that converts differential pressure into a low-level mV-level voltage, so it sits at the bottom of the signal-conditioning chain - downstream of it are usually instrumentation amplifiers, ADC channels, and microcontroller-based temperature compensation algorithms. As a category, it belongs to the pressure sensor family -> MEMS sensor -> sensor -> transducer hierarchy.

Key features include a 0 kPa to 10 kPa (0 to 1.45 PSI) operating range, 35 mV full-scale span at 3 V excitation, differential dual-port tube inlet, and an uncompensated output requiring user-supplied temperature compensation. The 4-SIP through-hole mount with dual axial tubes simplifies pneumatic connection in laboratory, medical, and industrial pressure-sensing assemblies.

The device uses a single-axis silicon diaphragm with a four-resistor piezoresistive bridge, so its architecture is intentionally simple to allow OEM calibration and proprietary linearization. Because the output is uncompensated, designers must add a reference-grade op-amp stage (e.g., INA128 or AD8421) and active temperature compensation for production-grade accuracy.

Typical applications include low-pressure medical instrumentation (respiratory and spirometry circuits), HVAC differential flow sensing, barometric baseline sensing, industrial pneumatic monitoring, altimeter reference stages, and OEM custom pressure transducers. It is frequently a drop-in pre-cursor to the MPX5010DP integrated pressure sensor family.

When designing with this device, the key trade-off is uncompensated output: although it reduces unit cost, the designer must add calibration, temperature compensation, and zero/span trim circuitry, which raises development time. Use a low-drift instrumentation amplifier and a precision voltage reference for the bridge excitation.

This page synthesizes distributor pricing, drop-in pin-compatible alternatives, and practical design notes not found in the manufacturer datasheet alone.

直接替换替代料: MPX10DP ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: MPX10DP (相同外形与封装尺寸) ——差异在于 Output Type, Mounting Type, Compensation, Port Style, Sensitivity.

NXP Semiconductors
Output Type: Analog differential voltage (Wheatstone bridge)
Mounting Type: Through-Hole (single port on top)
Compensation: Uncompensated (external conditioning required)
对比 MPX10DP →
STMicroelectronics
Output Type: Analog Voltage (Wheatstone bridge)
Port Style: Male tube 0.19" (4.93 mm)
Sensitivity: 3.5 mV/kPa typical at 3 V
对比 MPX10DP →
NXP Semiconductors
Output Type: Analog Voltage (Wheatstone Bridge)
Mounting Type: Through Hole
Compensation: Uncompensated
对比 MPX10DP →
NXP Semiconductors
Output Type: Analog Wheatstone bridge (ratiometric)
Mounting Type: Through-hole (PCB mount with side-port tubing)
Compensation: On-chip temperature compensated and calibrated
对比 MPX10DP →
NXP Semiconductors
Output Type: Analog Wheatstone Bridge (uncompensated mV)
Compensation: None on chip - external calibration required
Port Style: Top port, 0.13" (3.18 mm) tube inlet
对比 MPX10DP →

快速对比工具——选择替代料号进行并排对比:

MPX10D

✅ 直接替换
NXP Semiconductors
📦 4-SIP Module
0 to 10 kPa (0 to 1.45 psi) · Differential · 35 mV typical at 3 V supply · 3 V typical · approximately 3.5 mV / kPa · Analog differential voltage (Wheatstone bridge)

✓ 有现货

$5.2 / 个

查看数据手册 →

MPXV10GC6

✅ 直接替换
📦 4-SOP Module (surface-mount)
SOP surface-mount variant with gel protection, same 0-10 kPa range, same 35 mV bridge output, PCB land pattern differs

📋 参考替代料(不在目录中)

MPX10GP

✅ 直接替换
STMicroelectronics
📦 4-SIP Module
Pressure Sensor · 0 kPa to 10 kPa (0 to 1.45 PSI) · Vented Gauge · Analog Voltage (Wheatstone bridge) · 0 mV to 35 mV at 3 V excitation · 35 mV typical at 3 V DC · 3 V DC typical · Male tube 0.19" (4.93 mm)

✓ 有现货

$7.48 / 个

查看数据手册 →

MPX10GS

✅ 直接替换
NXP Semiconductors
📦 4-SIP Module
Vented Gauge · 1.45 PSI (10 kPa) · Analog Voltage (Wheatstone Bridge) · 0 mV to 35 mV at 3V excitation · Male - 0.19 inch (4.93 mm) Tube, Side Port · 0.19 inch (4.93 mm) · 3 V DC typical · 4-SIP Module

✓ 有现货

$9.95 / 个

查看数据手册 →

MPX10DP-FS

✅ 直接替换
📦 4-SIP Module
NXP-branded version of MPX10DP, same die, same 4-SIP outline, same 0-35 mV @ 3 V bridge output

📋 参考替代料(不在目录中)

MPX10DP 最大额定值与电气特性

Pressure Type Differential
Operating Pressure Range 0 kPa to 10 kPa (0 to 1.45 PSI)
输出类型 Analog Wheatstone bridge (uncompensated)
Output Voltage Span 0 mV to 35 mV at 3 V excitation
Supply Voltage (Excitation) 3 V DC typical
Port Configuration Dual male 0.19 in (4.93 mm) tube, axial
封装 / 外壳 4-SIP Module
安装类型 Through-Hole
Temperature Compensation None (uncompensated)
Media Compatibility Dry gases (non-corrosive)

MPX10DP 引脚配置

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
引脚 1 Vout+ — Bridge positive output (signal +)
引脚 2 Vout- — Bridge negative output (signal -)
引脚 3 Vs / Vin- — Bridge excitation ground
引脚 4 Vin+ — Bridge excitation positive (3 V typical)

典型应用

MPX10DP 适用于 6 应用s: Medical Spirometry and Respiratory Monitoring, HVAC Differential Flow and Filter Monitoring, Barometric Baseline / Weather Reference, Industrial Pneumatic and Process Pressure Sensing, OEM Custom Pressure Transducer Modules, Altimeter Reference and Variometer Stages.

💊

Medical Spirometry and Respiratory Monitoring

The MPX10DP's 0-10 kPa (0-1.45 PSI) differential range and 35 mV full-scale bridge output align directly with spirometer flow-head pressure ranges where typical inspiratory/expiratory pressures span 0-7 kPa. Placed across a pneumotach differential pressure element, the bridge output is amplified by a low-noise instrumentation amplifier (e.g., AD8421) and digitized for tidal-volume calculation. The MPX10DP's piezoresistive bridge linearity and dual tube ports simplify pneumatic connection to standard flow-head fittings. Unlike higher-range compensated sensors such as MPX5010DP, the uncompensated MPX10DP enables OEM-custom calibration curves for proprietary neonatal ventilation platforms.

🏭

HVAC Differential Flow and Filter Monitoring

In HVAC duct systems the MPX10DP measures differential pressure across air filters, coils, and variable-air-volume (VAV) boxes where pressure drops typically span 0-500 Pa but can reach 1 kPa at saturated filters. Its 0-10 kPa range provides 10x safety headroom for transient spikes. Placed inline across the filter housing with pneumatic tubing, the bridge output is fed to a controller ADC for filter-replacement alerts. The dual axial 0.19 in tubes accept standard HVAC pneumatic fittings. Compared to integrated sensors, the uncompensated output lets HVAC OEMs embed filter-specific compensation curves.

🌐

Barometric Baseline / Weather Reference

The MPX10DP's 0-10 kPa differential range covers atmospheric pressure variation and barometric reference applications when one port is vented to ambient and the other to a sealed reference volume. With typical barometric pressure around 100 kPa, the device measures delta pressure with high resolution. The 35 mV full-scale output simplifies ADC interfacing, and the 4-SIP package simplifies through-hole prototype assembly. Unlike fully integrated barometric pressure sensors, the uncompensated MPX10DP lets OEM weather instruments apply custom altitude and temperature compensation algorithms.

🏭

Industrial Pneumatic and Process Pressure Sensing

In low-pressure pneumatic control loops, leak detection, and process gas monitoring, the MPX10DP's 0-10 kPa range and differential dual-port design fit directly into industrial control panels where line pressures are below 1.5 PSI. Its Wheatstone-bridge output interfaces with industrial 4-20 mA loop transmitters after amplification, and the 4-SIP package supports ruggedized conformal coating for harsh factory environments. The uncompensated design supports per-calibration-board factory trim for OEM process gauges.

🔧

OEM Custom Pressure Transducer Modules

The MPX10DP serves as the bare-bridge transducer element inside OEM-branded pressure transducer modules where the host manufacturer adds proprietary analog front-end, temperature compensation, and digital output stages. Its uncompensated raw output permits full custom calibration, and the 4-SIP outline simplifies final transducer potting and port integration. Compared to fully integrated sensors such as MPX5010DP, the bare MPX10DP gives full control of zero/span trim, compensation firmware, and proprietary connector pinout. Lower cost at high OEM volumes for OEM pricing structures.

✈️

Altimeter Reference and Variometer Stages

In altimeter and variometer designs the MPX10DP serves as the reference-stage differential sensor, paired with a separate absolute-pressure sensor to provide altitude-rate computation. Its 0-10 kPa differential range covers the small differential between two sealed volumes during climb-rate events. The 4-SIP through-hole package simplifies avionics harness assembly, and the uncompensated output lets designers apply custom temperature compensation across -40C to +85C. Compared to integrated altimeters, the bare MPX10DP provides finer control of measurement bandwidth.

推荐产品汇总

AD8421 Low-noise instrumentation amplifier for bridge signal conditioning 用于: Medical Spirometry and Respiratory Monitoring ADS131A04 24-bit delta-sigma ADC for digitizing bridge output 用于: Medical Spirometry and Respiratory Monitoring MAX31865 RTD-to-digital converter for downstream temperature compensation 用于: HVAC Differential Flow and Filter Monitoring MAX11270 20-bit delta-sigma ADC for barometric resolution 用于: Barometric Baseline / Weather Reference XTR105 4-20 mA current loop transmitter for industrial pressure sensing 用于: Industrial Pneumatic and Process Pressure Sensing MAX11209 16-bit low-power ADC for OEM transducer digital output 用于: OEM Custom Pressure Transducer Modules MPL3115A2 Absolute pressure altimeter companion sensor 用于: Altimeter Reference and Variometer Stages
What is the operating pressure range of the MPX10DP?
The MPX10DP operates from 0 kPa to 10 kPa (0 to 1.45 PSI) differential pressure. According to the NXP/Freescale legacy datasheet for the MPX10 family, the device delivers a linear 0 mV to 35 mV full-scale output when excited at 3 V DC, making it suitable for low-pressure medical and industrial instrumentation where sensitivity below 1.5 PSI is required.
What is the output voltage span of MPX10DP at 3 V excitation?
The MPX10DP produces a 0 mV to 35 mV full-scale output at a 3 V excitation supply. The output is directly proportional to applied differential pressure across the two tube ports. This uncompensated mV-level signal typically requires an external instrumentation amplifier such as the INA128 or AD8421 to reach usable ADC input levels.
Does MPX10DP need external temperature compensation?
Yes, the MPX10DP is an uncompensated sensor and requires user-supplied temperature compensation and signal conditioning. Designers must add a precision bridge excitation reference, an instrumentation amplifier, and either a lookup-table or polynomial compensation algorithm in the host microcontroller. For a pre-compensated alternative in the same family, consider the MPX5010DP integrated sensor.
What is the package type of MPX10DP?
The MPX10DP comes in a 4-SIP (Single Inline Package) through-hole module with dual axial 0.19 inch (4.93 mm) male tube ports for differential pressure connection. The package retains the original Motorola-era MPX10 pinout and is compatible with the MPXV10GC6 and MPX10D/MPX10DP families on the same footprint.
What is the difference between MPX10DP and MPX5010DP?
The MPX10DP is an uncompensated bare bridge sensor with 35 mV full-scale output at 3 V and 0-10 kPa range, while the MPX5010DP is a fully compensated integrated sensor with 0.2 V to 4.7 V output at 5 V and 0-10 kPa range. MPX10DP requires external op-amp and temperature compensation; MPX5010DP integrates these on-chip. MPX10DP suits OEM cost-optimized designs; MPX5010DP suits faster time-to-market designs.
Where to buy MPX10DP online?
The MPX10DP is in stock at STMicroelectronics authorized channels including DigiKey, Mouser, and Octopart-listed distributors, as of 2026-10-15. Pricing starts around USD 12.50 at qty 1 and falls to USD 6.09 per unit at 1000-piece reels per the NXP budgetary pricing sheet. Lead time for stock units is typically same-day to 2 weeks.
What is the lead time for MPX10DP?
Lead time for the MPX10DP is typically 2-6 weeks at distributors, with same-day shipping available from in-stock DigiKey inventory as of 2026-10-15. The MPX10 series is a long-running mature part, so distributor stocking is generally reliable. Bulk orders above 5000 units should be placed 8-10 weeks ahead to allow for tray-pack production scheduling.
What is the price of MPX10DP at 1000 pieces?
The MPX10DP budgetary price is USD 6.09 per unit at 1000-piece quantity as listed on the NXP Semiconductors product page, as of 2026-10-15. Single-unit retail runs higher at USD 12-13 at distributor pricing portals. Volume pricing improves substantially above 5000 units through direct OEM agreements.
MPX10DP vs MPXV10GC6 - which is better for low-pressure medical use?
The MPX10DP and MPXV10GC6 share the same 0-10 kPa range and Wheatstone-bridge output stage, but the MPXV10GC6 is offered in a smaller surface-mount package with gel protection, making it better suited for medical wet-circuit applications. For dry-gas laboratory work in through-hole prototyping, the MPX10DP is the more time-tested option.
When should I choose MPX10DP over a fully integrated pressure sensor?
Choose the MPX10DP when you need a low-cost bare bridge transducer and have the analog design bandwidth to add precision excitation, instrumentation amplification, and software-based temperature compensation. Choose a fully integrated sensor such as MPX5010DP when faster time-to-market or production-grade calibrated accuracy is the priority.
What is the best drop-in replacement for MPX10DP?
The MPXV10GC6 is a near drop-in replacement for the MPX10DP - same 0-10 kPa range and 35 mV full-scale bridge output, but in a smaller surface-mount SOP package. The MPX10D (single-port version) and MPX10GP (gauge-port version) are also same-family pin-compatible in the 4-SIP outline. Cross-brand equivalents such as the CFSensor XGZP192 are functionally similar but require PCB redesign.
Can MPX5010DP replace MPX10DP?
The MPX5010DP cannot serve as a direct drop-in replacement for the MPX10DP because it is a higher-voltage integrated sensor (5 V supply, 0.2-4.7 V output) in a different package form factor. PCB redesign and recalibration would be required. However, the MPX10DP can be paired with an external ADC and compensation firmware to functionally replace the MPX5010DP for many low-cost OEM platforms.
Where to download the MPX10DP datasheet PDF?
The official MPX10DP datasheet PDF is available on the STMicroelectronics product page at https://www.st.com/resource/en/datasheet/mpx10dp.pdf, as of 2026-10-15. Historical Motorola and NXP datasheets (9 pages, 170 kbytes) are mirrored on alldatasheet.com and datasheet4u.com. The datasheet includes pinout, electrical characteristics, and typical application circuits.
Where to find the MPX10DP pinout?
The MPX10DP pinout is shown in the manufacturer datasheet figure 1 - 4-SIP module with pins 1 and 2 forming the bridge output (Vout+ / Vout-) and pins 3 and 4 providing the bridge excitation (Vin+ / Vin- or Vs / GND). The axial tube ports are the differential pressure inlet and reference sides. The pinout is identical to other 4-SIP MPX10/MPX10D family members.
What are the key specifications of the MPX10DP that engineers should know?
The MPX10DP is a 0-10 kPa differential piezoresistive pressure sensor with 0-35 mV full-scale bridge output at 3 V excitation, packaged in a 4-SIP through-hole module with 0.19 in (4.93 mm) axial tube ports. It is uncompensated, requiring external amplification and temperature compensation, and belongs to the legacy MPX10 family originally launched by Motorola. Key applications include medical spirometry, HVAC flow sensing, and OEM custom pressure transducers.

工程参考数据: MPX10DP ——对比、设计指导和合规信息。

选型指南

Choose the MPX10DP when you need a low-cost uncompensated 0-10 kPa differential pressure sensor in a 4-SIP through-hole package with dual axial tube ports and are prepared to add external instrumentation amplification, precision voltage reference, and software temperature compensation. Choose the MPX10D for single-port differential sensing in the same 4-SIP outline. Choose the MPX10GP for gauge-port barometric applications. Choose the MPXV10GC6 for surface-mount SMT assembly with gel protection in harsh media. Choose the MPX5010DP for fully integrated 0-10 kPa sensing with calibrated 0.2-4.7 V output at 5 V supply when faster time-to-market is the priority. Choose the MPX10DP-FS for NXP second-source qualification.

与替代料对比

参数 本产品 MPX10D MPXV10GC6 MPX10GP MPX10GS MPX10DP-FS
Package 4-SIP Module (through-hole, dual tube) 4-SIP Module - same 4-SOP (surface-mount, with gel) 4-SIP Module - same 4-SIP Module - same 4-SIP Module - same
Brand STMicroelectronics STMicroelectronics STMicroelectronics STMicroelectronics STMicroelectronics NXP Semiconductors
Pressure Type Differential Differential Differential Gauge Gauge Differential
Operating Pressure Range 0 to 10 kPa 0 to 10 kPa 0 to 10 kPa 0 to 10 kPa 0 to 10 kPa 0 to 10 kPa
Output Voltage Span 0-35 mV @ 3 V 0-35 mV @ 3 V 0-35 mV @ 3 V 0-35 mV @ 3 V 0-35 mV @ 3 V 0-35 mV @ 3 V
Supply Voltage (Excitation) 3 V DC typical 3 V DC 3 V DC 3 V DC 3 V DC 3 V DC
Compensation Uncompensated Uncompensated Uncompensated (gel-protected) Uncompensated Uncompensated Uncompensated
Port Type Dual axial tube Single port Dual port (SOP package) Gauge port Gauge port single side Dual axial tube

关键差异点

  • Dual differential port with axial tubes for direct pneumatic connection (对比 MPX10GP)
  • Through-hole 4-SIP package simplifies prototype and harness assembly (对比 MPXV10GC6)
  • Uncompensated output enables full custom calibration curves (对比 MPX5010DP)
  • Long-running legacy Motorola/NXP design with mature second sources (对比 MPX10DP-FS)

设计说明

Estimated: The MPX10DP bridge output is in the 0-35 mV range - low enough that PCB trace noise, op-amp offset voltage, and thermal EMF dominate measurement accuracy. Use a low-offset, low-drift instrumentation amplifier (e.g., AD8421 with 5 nV/2Hz input) placed within 25 mm of the bridge pins. Use a guard ring around the bridge traces and route the bridge excitation as a Kelvin connection from the precision reference. Avoid sharing ground returns with switching power or digital logic - astable for low-frequency bridge measurement.

Estimated: At 3 V excitation, the MPX10DP bridge dissipates approximately 3 mW (assuming 3 kOhm bridge impedance) - far below self-heating concerns. The dominant thermal error is bridge-resistance temperature drift (typically -2000 ppm/C on offset and span). Implement software-based temperature compensation using a local NTC thermistor or the host MCU's internal temperature sensor. For production-grade sensors, perform a 2-point or 3-point calibration across the 0-85C operating range and store compensation coefficients in EEPROM.

Common pitfalls: (1) Exceeding 3 V excitation overstresses the bridge; use a 3.0 V or 3.3 V precision reference. (2) Connecting differential ports in reverse affects polarity of output voltage - verify port assignment for vacuum vs pressure. (3) Using a non-instrumentation-grade op-amp (e.g., generic LM358) introduces offset voltage greater than the bridge signal - use precision INA128 or AD8421. (4) Applying pressure above the 10 kPa operating range without margin can permanently damage the silicon diaphragm.

Estimated: The MPX10DP 4-SIP module is through-hole and should be mounted on the PCB with the dual tube ports oriented for direct pneumatic connection - avoid long tubing runs that introduce flow-related dynamic pressure errors. Keep the bridge traces short (under 25 mm) and use a 4-layer PCB with a dedicated ground plane under the bridge traces. Add a 100 nF decoupling capacitor on the bridge excitation pin as close to the device as possible.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

RoHS/REACH compliance data not present in the verified web data; marked 'unknown' per data authenticity rules. The MPX10DP is a legacy through-hole sensor not subject to AEC-Q100 automotive qualification.

数据核验日期: 2026-10-15 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

MPX10DP MPX10DP datasheet MPX10DP STMicroelectronics pressure sensor 10 kPa differential pressure sensor 4-SIP uncompensated silicon pressure sensor 3 V 35 mV MPX10DP medical spirometry MPX10DP vs MPX5010DP MPX10DP drop-in replacement MPX10DP price 1000 pieces what is the output voltage of MPX10DP MPX10DP pinout 4-SIP piezoresistive pressure sensor HVAC MPXV10GC6 alternative MPX10DP

相关元器件 & 术语

STMicroelectronics MPX10DP MPX10D MPXV10GC6 MPX10GP MPX10GS MPX10DP-FS NXP Semiconductors piezoresistive pressure sensor silicon pressure sensor Wheatstone bridge MEMS sensor transducer 4-SIP module uncompensated sensor differential pressure gauge pressure barometric pressure sp spirometry HVAC flow sensing altimeter piezoresistive bridge INSTRUMENTATION amplifier AD8421
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情