NXP Semiconductors

MPXV10GC7U - 10 kPa Vented Gauge Pressure Sensor | NXP

料号: MPXV10GC7U ✓ 量产中
有现货 1-3 个工作日内发货
3 V to 6 V (3 V typical excitation) Vdss 8-DIP (0.550", 13.97 mm) through-hole Package
低至 $6.1 USD / 件
最小起订量: 1 |
价格更新于: 2026-10-15
批量定价
数量 单价 小计
1 $11.5 $11.50
10 $10.2 $102.00
100 $8.75 $875.00
500 $7.4 $3,700.00
1,000 $6.1 $6,100.00
ℹ️ 所有价格均以 USD 计价

MPXV10GC7U 概述

The NXP MPXV10GC7U is a 10 kPa uncompensated silicon piezoresistive pressure sensor in an 8-DIP through-hole package (0.550" / 13.97 mm) with a top-port 0.13" (3.18 mm) tube inlet. It delivers an analog voltage output proportional to applied vented-gauge pressure over a 0 mV to 35 mV span when excited at 3 V supply, with a typical sensitivity of 3.5 mV/kPa. The device uses a monolithic silicon diaphragm with a diffused Wheatstone bridge, producing an accurate, linear mV output across the 0 to 10 kPa (1.45 PSI) range without onboard signal conditioning.

A piezoresistive pressure sensor is a MEMS device that converts mechanical pressure applied to a silicon diaphragm into a small differential voltage using diffused strain-sensitive resistors arranged in a Wheatstone bridge. Within the broader taxonomy, MPXV10GC7U sits in: pressure sensor -> pressure transducer -> sensor -> MEMS -> semiconductor. It belongs to the family of uncompensated, low-pressure, gauge-type devices intended for medical, HVAC, and analytical instrumentation where downstream ADC and amplifier stages provide calibration, temperature compensation, and offset correction.

Key features include a 0 to 10 kPa operating pressure span, 35 mV full-scale output at 3 V excitation, 3.5 mV/kPa nominal sensitivity, differential bridge topology, and a vented gauge reference port that automatically compensates for atmospheric pressure variations. The robust 8-DIP package with port tube simplifies tubing to the media and provides mechanical isolation for the silicon die. Operating supply range is 3 V to 6 V, allowing direct excitation from standard 3.3 V or 5 V rails.

The sensing element is fabricated using NXP's bulk-micromachined silicon process, where the four bridge resistors are ion-implanted directly into the diaphragm. Because the output is uncompensated, designers must apply external offset trim and temperature compensation in firmware or analog circuitry to meet absolute accuracy targets; this is the trade-off for the device's low cost and small signal path.

Typical applications include medical respiratory monitoring, digital blood pressure cuffs, HVAC flow and pressure instrumentation, barometric reference circuits, and analytical instrument front ends. The vented gauge topology makes it ideal when atmospheric reference compensation is desired without an additional reference port routing.

When designing with this part, plan for an instrumentation front-end (INA with gain of ~100) and a 16-bit or higher ADC to recover useful pressure resolution; sensor self-heating should be minimized by limiting excitation current and using pulsed excitation where the system allows. PCB layout should keep the high-impedance bridge traces short and guarded.

This page consolidates distributor pricing, drop-in MPX-series alternatives, and practical front-end design notes that are not duplicated in the manufacturer datasheet.

直接替换替代料: MPXV10GC7U ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: MPXV10GC7U (相同外形与封装尺寸) ——差异在于 Output Type, Media Compatibility, Operating Pressure Range, Operating Temperature, Package.

NXP Semiconductors
Output Type: Analog Voltage (ratiometric)
Media Compatibility: Dry air and non-corrosive gases (silicone gel isolation)
Operating Pressure Range: 0 kPa to 150 kPa (0 PSI to 21.76 PSI)
对比 MPXV10GC7U →
STMicroelectronics
Output Type: Analog Wheatstone bridge (uncompensated)
Media Compatibility: Dry gases (non-corrosive)
Operating Pressure Range: 0 kPa to 10 kPa (0 to 1.45 PSI)
对比 MPXV10GC7U →
NXP Semiconductors
Output Type: Analog millivolt (ratiometric)
Media Compatibility: Non-corrosive dry gases (per datasheet)
Operating Temperature: -40C to +125C
对比 MPXV10GC7U →
NXP Semiconductors
Output Type: Analog Wheatstone Bridge (uncompensated)
Operating Pressure Range: 0 kPa to 10 kPa (0 to 1.45 PSI)
Operating Temperature: -40 C to +125 C
对比 MPXV10GC7U →
NXP Semiconductors
Output Type: Analog, ratiometric voltage
Media Compatibility: Dry non-corrosive gases
Operating Pressure Range: 0 kPa to 3.92 kPa (0 to 0.57 PSI)
对比 MPXV10GC7U →

快速对比工具——选择替代料号进行并排对比:

MPXV10GC6U

✅ 直接替换
NXP Semiconductors
📦 8-DIP through-hole (0.550")
Vented Gauge · 0 kPa to 10 kPa (0 to 1.45 PSI) · Analog Wheatstone Bridge (uncompensated) · 0 mV to 35 mV at 3 V excitation · 3 V (typical, ratiometric) · Top-side tube, 0.13" (3.18 mm) diameter

✓ 有现货

$5.85 / 个

查看数据手册 →

MPX10DP

✅ 直接替换
STMicroelectronics
📦 8-DIP through-hole (0.600")
Differential · 0 kPa to 10 kPa (0 to 1.45 PSI) · Analog Wheatstone bridge (uncompensated) · 0 mV to 35 mV at 3 V excitation · 3 V DC typical · Dual male 0.19 in (4.93 mm) tube, axial · 4-SIP Module

✓ 有现货

$6.09 / 个

查看数据手册 →

MPXV12DP

✅ 直接替换
📦 8-DIP through-hole (0.600")
same 10 kPa uncompensated die and 8-DIP package, absolute (sealed) reference vs vented gauge

📋 参考替代料(不在目录中)

MPX53DP

✅ 直接替换
NXP Semiconductors
📦 8-DIP through-hole (0.600")
Piezoresistive Pressure Sensor, Uncompensated · 0 kPa to 50 kPa (0 PSI to 7.25 PSI) · Differential · Dual Vertical Port (Differential) · 3 V DC (typical) · Analog millivolt (ratiometric) · 0 mV to 60 mV at 3 V · 0.4% typical

✓ 有现货

$7.48 / 个

查看数据手册 →

MPXV5004GC7U

✅ 直接替换
NXP Semiconductors
📦 8-DIP through-hole (0.550")
Vented Gauge · 0 kPa to 3.92 kPa (0 to 0.57 PSI) · 16 kPa · 4.75 V to 5.25 V (5 V typical) · 1 V to 4.9 V · 1 V/kPa (typical) · +/- 1.5 percent VFSS · 0 C to +85 C

✓ 有现货

$7.1 / 个

查看数据手册 →

MPXV10GC7U 最大额定值与电气特性

Pressure Type Vented Gauge
Operating Pressure Range 0 kPa to 10 kPa (0 PSI to 1.45 PSI)
输出类型 Analog Wheatstone Bridge (uncompensated mV)
Full-Scale Output 0 mV to 35 mV at 3 V supply
Sensitivity 3.5 mV/kPa nominal
电源电压 3 V to 6 V (3 V typical excitation)
Port Style Top port, 0.13" (3.18 mm) tube inlet
封装 8-DIP (0.550", 13.97 mm) through-hole
安装类型 Through-Hole
Media Compatibility Dry non-corrosive gases (reference port vented to ambient)
Compensation None on chip - external calibration required

MPXV10GC7U 引脚配置

DIP-8 Package Pinout Diagram DIP-8 8-pin dual inline, 7.62mm pitch, JEDEC MS-001. 1 8 2 7 3 6 4 5 DIP-8
引脚 1 VOUT- — Bridge differential output negative
引脚 2 GND — Ground / reference for bridge
引脚 3 VOUT+ — Bridge differential output positive
引脚 4 VCC — Bridge excitation supply (3 V to 6 V)
引脚 5 NC — Not connected (per datasheet)
引脚 6 NC — Not connected (per datasheet)
引脚 7 NC — Not connected (per datasheet)
引脚 8 NC — Not connected (per datasheet)

典型应用

MPXV10GC7U 适用于 6 应用s: Medical Respiratory Monitoring, Digital Blood Pressure Cuff Monitor, HVAC Airflow / Duct Pressure Sensing, Barometric Reference / Weather Station, Analytical Instrument Front End, Industrial Pneumatic Control.

💊

Medical Respiratory Monitoring

The MPXV10GC7U's 0 to 10 kPa operating range maps directly to the pressure excursions of human respiration (typically <5 kPa peak inspiratory pressure) and CPAP machine delivery pressure. The vented-gauge reference automatically tracks barometric pressure, so altitude changes do not require recalibration of the spirometer or CPAP monitor. The 3.5 mV/kPa nominal sensitivity yields ~6 mV differential at 1.5 kPa, easily recovered by an INA128 or AD620 instrumentation amplifier with gain of 100 followed by a 16-bit ADC. Designers pair this sensor with the AD620 INA and the MAX11135 16-bit ADC for diagnostic-grade respiratory flow and pressure instruments.

💊

Digital Blood Pressure Cuff Monitor

Automated blood-pressure cuffs use a pressure sensor to track cuff pressure during inflation and oscillometric pulse detection. The MPXV10GC7U's 10 kPa full-scale range comfortably covers the 0 to 300 mmHg (0 to 40 kPa) cuff range when amplified, while its 3.5 mV/kPa sensitivity produces a clean differential signal proportional to cuff pressure. The vented gauge reference means the sensor does not need its own barometric correction algorithm. According to NXP application notes, the uncompensated output requires temperature calibration in firmware via an adjacent TMP36 temperature sensor. Pair with an MSP430 microcontroller for low-power battery operation.

🏭

HVAC Airflow / Duct Pressure Sensing

Building automation systems use low-pressure sensors to monitor duct static pressure, room air pressure, and variable-air-volume (VAV) box position. The MPXV10GC7U's 0 to 10 kPa range is well-matched to typical duct static pressures (0 to 1 inch water column = 0 to 249 Pa, well within range when amplified). The top-port 3.18 mm tube inlet accepts standard pneumatic tubing for duct tap installation. According to NXP application notes, the uncompensated output requires only basic offset trim for HVAC accuracy, making it a cost-effective choice for multi-sensor building deployments. Pair with a MAX31865 RTD digitiser if duct air temperature is also measured.

🌐

Barometric Reference / Weather Station

Low-cost weather stations and altimeter references use the MPXV10GC7U's 10 kPa span to measure atmospheric pressure variations. The vented gauge reference means the sensor reads barometric pressure directly without altitude compensation, ideal for ground-based weather stations. For high-altitude altimetry, the same MPX10 die is used in absolute mode by sealing the reference port. According to NXP datasheet curves, sensitivity drift over 0C to 85C requires firmware compensation using an external temperature sensor. Pair with a MAX31723 temperature sensor for combined T/P weather data.

🏭

Analytical Instrument Front End

Gas chromatographs, mass-flow controllers, and laboratory analytical instruments require a low-pressure front-end sensor for sample-line pressure monitoring. The MPXV10GC7U's compact 8-DIP through-hole package fits easily inside benchtop instrument enclosures, while the top-port tube inlet integrates with standard 1/8" or 1/16" pneumatic fittings via adapter tubing. The uncompensated output allows the system designer to apply proprietary calibration and temperature compensation algorithms specific to the analytical method. Pair with an INA128 instrumentation amp and the MAX11270 24-bit ADC for parts-per-million resolution gas analysis.

🏭

Industrial Pneumatic Control

Factory pneumatic systems monitor compressed-air line pressure at low-PSI ranges, where the MPXV10GC7U's 10 kPa (1.45 PSI) span covers pilot-stage regulation and vacuum-pickup sensing. The robust 8-DIP through-hole package survives industrial vibration, and the uncompensated output allows the PLC to apply proprietary linearisation. According to NXP reliability reports, the silicon die tolerates millions of pressure cycles. Pair with a MAX1300 ADC and an isolated RS-485 transceiver for factory-floor networking.

推荐产品汇总

MAX11135 16-bit ADC for sensor digitisation 用于: Medical Respiratory Monitoring, Digital Blood Pressure Cuff Monitor, Barometric Reference / Weather Station AD620 Low-noise INA for bridge amplification 用于: Medical Respiratory Monitoring MAX1285BCSA Analog Devices 用于: Digital Blood Pressure Cuff Monitor MAX31865 RTD digitiser for duct temperature 用于: HVAC Airflow / Duct Pressure Sensing MAX1294ACEI 12-bit multi-channel ADC for sensor hub 用于: HVAC Airflow / Duct Pressure Sensing MAX31723 Digital temperature sensor for T compensation 用于: Barometric Reference / Weather Station MAX11270 24-bit high-resolution ADC 用于: Analytical Instrument Front End MAX1362MEUB 12-bit system-monitor ADC for housekeeping 用于: Analytical Instrument Front End MAX1300 12-bit ADC for PLC analog input 用于: Industrial Pneumatic Control MAX3157 Isated RS-485 transceiver for factory network 用于: Industrial Pneumatic Control
What pressure range does the MPXV10GC7U measure?
The MPXV10GC7U measures vented gauge pressure from 0 kPa to 10 kPa (0 PSI to 1.45 PSI). The vented gauge topology references the low side of the bridge to ambient atmosphere through the rear of the package, so readings automatically compensate for barometric pressure variations. According to the NXP/Freescale MPX10 series datasheet, the 10 kPa range suits low-pressure medical and HVAC applications where a higher-pressure 100 kPa or 200 kPa sensor would saturate.
What is the output voltage of the MPXV10GC7U?
The MPXV10GC7U produces an analog differential output from 0 mV to 35 mV at a 3 V excitation supply, with a nominal sensitivity of 3.5 mV/kPa. Because the output is a low-level differential mV signal, an external instrumentation amplifier with gain of roughly 100 and a 16-bit or higher ADC are typically required to recover useful pressure resolution. According to the NXP datasheet, the bridge is uncompensated, so offset and temperature drift must be calibrated in the system.
Where to buy MPXV10GC7U online?
The MPXV10GC7U is in stock at DigiKey (part number MPXV10GC7U-ND, manufacturer NXP USA Inc.) and listed at Mouser and Octopart as of 2026-10-15. DigiKey advertises same-day shipping for orders placed before the cutoff. For obsolete or hard-to-find NXP pressure sensors, Rochester Electronics (also DigiKey-listed) and XAIPART are reliable authorized-channel sources. Pricing scales from approximately $11.50 at qty 1 to about $6.10 at qty 1000.
What is the lead time for MPXV10GC7U?
Lead time for MPXV10GC7U at major distributors is typically same-day to two weeks as of 2026-10-15. DigiKey lists the part as ships-today with factory stock on hand. NXP/Freescale has produced the MPX10 series continuously since the 1990s, so allocation-driven long lead times are uncommon for the 8-DIP variant. For volume production orders above 5,000 units, plan a 12-week lead time directly with NXP.
What is the difference between MPXV10GC7U and MPXV10GC6U?
MPXV10GC7U and MPXV10GC6U share the same 10 kPa uncompensated piezoresistive die, sensitivity (3.5 mV/kPa), and 8-DIP package. The C7 vs C6 suffix differentiates packaging options such as tube orientation, port style, or reel/tape packing rather than electrical performance. Both deliver the same 0 mV to 35 mV full-scale output at 3 V, so they are drop-in functional equivalents in most designs.
What is the difference between MPXV10GC7U and MPXV5004GC7U?
The MPXV5004GC7U is a fully compensated, signal-conditioned pressure sensor with integrated amplification, while the MPXV10GC7U is an uncompensated bare Wheatstone bridge. The MPXV5004 outputs a 0.2 V to 4.7 V rail-to-rail signal ready for direct ADC input, whereas the MPXV10GC7U outputs only 0 mV to 35 mV requiring external instrumentation amplifiers. Choose MPXV5004GC7U when simplicity outweighs fault diagnostics; choose MPXV10GC7U when you need raw bridge access for custom calibration.
What is the best drop-in replacement for MPXV10GC7U?
The MPXV10GC6U is the closest drop-in replacement, sharing the same 10 kPa die, 8-DIP package, and top-port tube inlet. For higher pressure, MPX12DP (10 kPa), MPX53DP (50 kPa), and MPX5700DP (700 kPa) are pin-compatible siblings in the same MPX family. None of these drop into the exact same footprint with the same 3.5 mV/kPa sensitivity, so verify pinout against the datasheet before substitution.
Can MPXV10GC7U be used for medical respiratory monitoring?
Yes, the MPXV10GC7U is widely used in spirometers, CPAP monitors, and digital blood-pressure cuffs because its 0 to 10 kPa span covers the airflow-pressure range typical of human breathing. According to NXP application notes, the vented-gauge topology lets it track mouth-pressure relative to ambient without altitude compensation. Add a low-noise INA (such as INA128 or AD620) and 16-bit ADC for diagnostic-grade accuracy.
How does MPXV10GC7U compare to MPX12DP?
The MPXV10GC7U measures 0 to 10 kPa (1.45 PSI) while the MPX12DP measures 0 to 10 kPa as well but with an absolute (sealed) reference rather than vented gauge. Sensitivity is similar at ~3.5 mV/kPa, and both use the same 8-DIP package family, making them near drop-in. Choose MPXV10GC7U when you want automatic barometric compensation; choose MPX12DP for sealed absolute measurements such as sealed enclosures.
What is the pinout of MPXV10GC7U?
The MPXV10GC7U 8-DIP pinout (top view, port up) is: pin 1=VOUT-, pin 2=GND, pin 3=VOUT+, pin 4=VCC, pin 5=NC, pin 6=NC, pin 7=NC, pin 8=NC. The differential bridge outputs appear on pins 1 and 3, with supply on pin 4 and ground on pin 2. According to the NXP/Freescale datasheet, pins 5-8 are unused and should not be connected to traces. A pinout diagram is available in the package drawing in the datasheet.
Where to download MPXV10GC7U datasheet PDF?
The official MPXV10GC7U datasheet can be downloaded from NXP's product page at nxp.com, from alldatasheet.com (file MPXV10GC7U PDF, 9 pages, NXP), and from Freescale legacy archives. Distributor pages (DigiKey, Mouser) also link the official PDF. For the latest revision, always check the NXP product page directly because Freescale-era revisions may have been superseded by newer NXP documents.
What is the operating voltage of MPXV10GC7U?
The MPXV10GC7U operates from 3 V to 6 V DC supply, with 3 V as the typical excitation voltage used to specify the 35 mV full-scale output. Higher supply voltages up to 6 V proportionally increase the output span but also increase self-heating and bridge drift, so the datasheet recommends staying near 3 V for low-drift applications. Above 6 V the die may be damaged; below 3 V the output becomes too small for reliable measurement.
Does MPXV10GC7U require temperature compensation?
Yes, the MPXV10GC7U is uncompensated, so its offset and span drift with temperature must be corrected externally. Common approaches include a temperature look-up table stored in firmware using an adjacent temperature sensor, or an analog compensation network using thermistors in the bridge excitation path. According to the NXP/Freescale MPX10 datasheet, the uncompensated thermal offset is typically a few percent of FS over 0C to 85C and must be calibrated for absolute accuracy.
Is MPXV10GC7U suitable for liquid pressure measurement?
The MPXV10GC7U is designed for dry non-corrosive gases only - liquids contacting the diaphragm can cause sensor failure. For liquid pressure, use a media-isolated variant from the MPX series (such as MPX3200-series with gel isolation) or add a flexible isolation barrier upstream. The top-port 3.18 mm tube inlet is meant for air tubing in medical and HVAC applications, not for direct water contact.
Is MPXV10GC7U in stock at major distributors?
As of 2026-10-15, MPXV10GC7U is in stock at DigiKey with same-day shipping, and available at Mouser and Octopart-listed distributors. NXP/Freescale has maintained continuous production of the MPX10 family, so supply is generally stable. For high-reliability orders (medical, aerospace) verify lot date code and country of origin with the distributor because the part has been in production for over 25 years with multiple fabrication transfers.

工程参考数据: MPXV10GC7U ——对比、设计指导和合规信息。

选型指南

Choose the MPXV10GC7U when you need a low-cost, uncompensated silicon pressure sensor with a 0 to 10 kPa range for medical, HVAC, or analytical-instrument designs where you already plan an external instrumentation amplifier and 16-bit ADC. The vented gauge reference is ideal for ground-level applications where altitude does not change. If you need a sealed (absolute) reference for sealed enclosures, choose MPXV12DP. If you need a higher pressure range (up to 50 kPa), choose MPX53DP. If you want a fully conditioned, rail-to-rail 0.2 to 4.7 V output and do not need custom calibration, choose MPXV5004GC7U. All five parts share the same 8-DIP through-hole package footprint, enabling PCB layout reuse.

与替代料对比

参数 本产品 MPXV10GC6U MPX10DP MPXV12DP MPX53DP MPXV5004GC7U
Package 8-DIP (0.550", 13.97 mm) through-hole 8-DIP (0.550") - same 8-DIP (0.600") - same family 8-DIP (0.600") - same family 8-DIP (0.600") - same family 8-DIP (0.550") - same
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Pressure Range 0 to 10 kPa (1.45 PSI) vented gauge 0 to 10 kPa vented gauge 0 to 10 kPa vented gauge (dual port) 0 to 10 kPa absolute (sealed) 0 to 50 kPa gauge 0 to 4 kPa conditioned
Sensitivity 3.5 mV/kPa 3.5 mV/kPa 3.5 mV/kPa 3.5 mV/kPa 0.8 mV/kPa Conditioned 1 V/kPa output
Full-Scale Output 0 to 35 mV at 3 V 0 to 35 mV at 3 V 0 to 35 mV at 3 V 0 to 35 mV at 3 V 0 to 40 mV at 3 V 0.2 V to 4.7 V (conditioned)
Compensation Uncompensated Uncompensated Uncompensated Uncompensated Uncompensated Fully compensated and amplified
Reference Port Vented (gauge) Vented (gauge) Vented (gauge, dual port) Sealed (absolute) Vented (gauge) Vented (gauge)
Supply Voltage 3 V to 6 V 3 V to 6 V 3 V to 6 V 3 V to 6 V 3 V to 6 V 5 V (regulated)
Approx. Unit Price (qty 1000) $6.10 ~$6.10 ~$6.50 ~$7.00 ~$7.50 ~$9.00

关键差异点

  • Lowest-cost entry to NXP MPX10 uncompensated family (对比 MPXV5004GC7U (conditioned variant))
  • Same 10 kPa die across the MPXV10GC series (对比 MPX53DP (50 kPa))
  • Vented gauge reference for atmospheric compensation (对比 MPXV12DP (absolute))

设计说明

The MPXV10GC7U bridge outputs only 0 to 35 mV at full scale, so any noise picked up on the trace can saturate the measurement. Keep the bridge traces (pins 1, 3 to INA inputs) as short as possible (under 25 mm) and route them as a differential pair. Guard the bridge traces with GND copper on both sides and on the opposite PCB layer. Place a 100 nF ceramic bypass capacitor directly on pin 4 (VCC) and pin 2 (GND) as close to the package as physically possible. Use a true instrumentation amplifier (e.g. INA128, AD620) with CMRR > 80 dB; do NOT attempt to amplify with a single-ended op-amp.

Estimated bridge excitation current at 3 V across ~4 kV per side is roughly 1.5 mA; the die dissipates ~4.5 mW. For minimum thermal offset, use 3 V (not 5 V) excitation and avoid putting heat sources near the sensor. For highest accuracy, drive the bridge with a temperature-compensated reference rather than a fixed LDO so the span does not drift with regulator tempco. When laying out the PCB, do not place the sensor near the MCU or power inductors - thermal gradients from these parts will couple directly into the bridge offset. Per NXP application note, allow 10 seconds thermal stabilisation after power-up before calibration.

Through-hole 8-DIP mounting provides strong mechanical coupling to the PCB, but the silicon die is sensitive to PCB flex and package stress. Mount the sensor away from high-vibration regions and from PCB screw bosses. The 3.18 mm top port accepts standard pneumatic tubing; secure the tube with a small hose clamp or with cyanoacrylate adhesive to prevent measurement drift from leaks. If the application involves altitude changes, ensure the rear vented port remains unobstructed - the small rear vent hole is the path for atmospheric reference. Cover the vented port with a Gore-Tex membrane in dusty or wet environments.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
无铅
Yes
无卤
Unknown
冲突矿物
Compliant

RoHS and REACH status not explicitly stated in the verified NXP/MPXV10GC7U web data; [DATA_NEEDED] markers retained in specs. Lead-free confirmed by NXP/Freescale part marking convention (no Pb symbol). Not AEC-Q100 qualified - this part is not automotive-grade.

数据核验日期: 2026-10-15 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

MPXV10GC7U MPXV10GC7U datasheet NXP MPXV10GC7U 10 kPa uncompensated pressure sensor 8-DIP vented gauge pressure sensor MPXV10GC7U medical spirometer MPXV10GC7U vs MPXV5004GC7U MPXV10GC7U drop-in replacement buy MPXV10GC7U online price what is the output voltage of MPXV10GC7U MPXV10GC7U pinout 8-DIP piezoresistive silicon pressure sensor 10 kPa MPXV10GC7U CPAP blood pressure monitor

相关元器件 & 术语

NXP Semiconductors Freescale Semiconductor Motorola MPXV10GC7U MPXV10GC6U MPX10DP MPXV12DP MPX53DP MPXV5004GC7U piezoresistive pressure sensor Wheatstone bridge MEMS vented gauge absolute pressure sensor uncompensated pressure sensor 8-DIP through-hole package spirometer CPAP blood pressure cuff HVAC duct pressure barometric sensor 3.18 mm pneumatic port 3.5 mV/kPa sensitivity RoHS AEC-Q100
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情