MPX2010GS - 10 kPa Gauge Pressure Sensor | NXP | SIP-4

料号: MPX2010GS ✗ 停产
有现货 1-3 个工作日内发货
0 mV to 25 mV at 10 V excitation Vdss 4-SIP Module Package
低至 $15.95 USD / 件
最小起订量: 1 |
价格更新于: 2026-10-15
批量定价
数量 单价 小计
1 $28.5 $28.50
10 $25.2 $252.00
100 $21.8 $2,180.00
500 $18.4 $9,200.00
1,000 $15.95 $15,950.00
ℹ️ 所有价格均以 USD 计价

MPX2010GS 概述

The NXP MPX2010GS is a 10 kPa (1.45 psi) on-chip temperature-compensated and calibrated silicon piezoresistive pressure sensor packaged in a 4-SIP module with a 0.19" (4.93 mm) male tube vented-gauge port. It delivers a Wheatstone-bridge analog output spanning 0 mV to 25 mV at 10 V excitation and operates from a 10 V to 16 V supply. The series translates applied pressure into a highly linear, calibrated voltage for direct interface with instrumentation amplifiers and microcontrollers with on-board ADCs.

A piezoresistive pressure sensor is a transducer whose conversion of mechanical pressure into an electrical signal relies on a silicon diaphragm embedded with diffused Wheatstone-bridge resistors; when pressure deflects the diaphragm, the bridge imbalance produces a differential output proportional to the applied pressure. The MPX2010GS belongs to the board-mount pressure-sensor family within the broader transducer (sensor -> pressure sensor -> piezoresistive sensor -> gauge pressure sensor -> silicon pressure sensor) taxonomy and is commonly used wherever a small, linear, temperature-stabilized pressure-to-voltage conversion is required.

Key differentiating specifications include an operating pressure range of 0 to 10 kPa (0 to 1.45 psi), an output of 0 mV to 25 mV at 10 V, a Wheatstone-bridge analog output type, vented-gauge pressure type referenced to atmosphere, on-chip temperature compensation and calibration, and a 10 V to 16 V supply range. The integrated signal conditioning, calibration, and temperature compensation eliminate external compensation networks and reduce BOM count.

At its core, the MPX2010GS uses a single-element piezoresistive die laser-trimmed for span and offset, with on-chip compensation networks (resistors) flat across the 0 to 85 C operating range. The hermetic SIP-4 housing isolates the die from ambient humidity and provides a barbed tube port for pneumatic connection, with a vent port to atmosphere providing gauge (vs. absolute or differential) reference. Compared with uncompensated bare-die sensors, the integrated compensation substantially reduces system-level drift error.

Typical applications include medical respirators and ventilators, HVAC variable-air-volume (VAV) controllers, industrial process controllers, barometric/altimeter instrumentation, level measurement, and consumer appliances such as washing-machine water-level sensors. The 10 kPa range suits low-pressure medical and HVAC use cases where barometric noise would otherwise swamp a higher-range transducer.

When designing with the MPX2010GS, place an instrumentation amplifier (e.g., INA125, AD620, or NXP MPXAZ5010 interface) directly at the Wheatstone output to convert the millivolt bridge signal to a usable 0-5 V or 4-20 mA signal. Use a stable, low-noise excitation source (10 V typical) because sensor span scales linearly with excitation; noise and drift on the supply will be reflected in the output. Apply a bypass capacitor near the supply pin.

This page synthesizes distributor stock and pricing, calibrated drop-in equivalents, and applied design notes not consolidated on the manufacturer datasheet.

直接替换替代料: MPX2010GS ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: MPX2010GS (相同外形与封装尺寸) ——差异在于 Output Type, Operating Temperature, Accuracy, Supply Voltage, Technology.

STMicroelectronics
Output Type: Analog Wheatstone Bridge (mV)
对比 MPX2010GS →
NXP Semiconductors
Output Type: Analog voltage, Wheatstone bridge (mV level)
Operating Temperature: -40 °C to +125 °C
Supply Voltage: 10 V DC typical (max 16 V)
对比 MPX2010GS →
NXP Semiconductors
Output Type: Analog, ratiometric
Operating Temperature: 0 C to +85 C (compensated)
Accuracy: +/-2.5% of full-scale span
对比 MPX2010GS →
NXP Semiconductors
Output Type: Analog Voltage (ratiometric)
Operating Temperature: -40 C to +125 C
Accuracy: 2.5% (per distributor data)
对比 MPX2010GS →

快速对比工具——选择替代料号进行并排对比:

MPX2010GVS

✅ 直接替换
📦 4-SIP Module
same 4-SIP gauge sensor, vertical port orientation vs horizontal; 0-10 kPa, 0-25 mV, 10-16V identical

📋 参考替代料(不在目录中)

MPX2010DP

✅ 直接替换
NXP Semiconductors
📦 4-SIP Module
Differential Pressure Sensor · 0 to 10 kPa (0 to 1.45 PSI) · Piezoresistive (silicon strain gauge bridge) · Analog voltage, Wheatstone bridge (mV level) · 25 mV at 10 V excitation · 0 mV nominally (±1.0 mV max) · 10 V DC typical (max 16 V) · ±0.05% (typ)

✓ 有现货

$8.5 / 个

查看数据手册 →

MPX5010GS

✅ 直接替换
NXP Semiconductors
📦 4-SIP Module
Vented Gauge · 0 kPa to 10 kPa (0 to 1.45 PSI) · 4.75 V to 5.25 V (5 V typical) · 5 mA typical · 0.2 V to 4.7 V at 5 V supply · +/-2.5% of full-scale span · 1.0 ms typical

✓ 有现货

$10.85 / 个

查看数据手册 →

MPX5050GP

✅ 直接替换
NXP Semiconductors
📦 4-SIP Module
Vented Gauge · 0 kPa to 50 kPa (0 PSI to 7.25 PSI) · 200 kPa (per MPX5050 family) · Analog Voltage (ratiometric) · 0.2 V to 4.7 V · 4.75 V to 5.25 V (5 V nominal) · 7 mA nominal · 2.5% (per distributor data)

✓ 有现货

$7.85 / 个

查看数据手册 →

MPX2010GS 最大额定值与电气特性

Pressure Type Vented Gauge
Operating Pressure 1.45 PSI (10 kPa)
输出类型 Wheatstone Bridge (analog voltage)
输出电压 0 mV to 25 mV at 10 V excitation
电源电压 10 V to 16 V
Accuracy +/-1% (per data brief)
Port Size Male - 0.19" (4.93 mm) Tube
Port Style Barbed, single vented-gauge port
封装 / 外壳 4-SIP Module
安装类型 Through-Hole
工作温度 -40C to +125C (per MPX2010 series datasheet)
Technology Piezoresistive (silicon diaphragm)
Compensation On-chip temperature compensated and calibrated

MPX2010GS 引脚配置

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
引脚 1 Vout+ — Bridge positive output
引脚 2 Vout- — Bridge negative output
引脚 3 Vs+ — Supply (10 V to 16 V)
引脚 4 GND — Ground

典型应用

MPX2010GS 适用于 6 应用s: Medical Ventilator and Respirator Pressure Monitoring, HVAC Variable Air Volume (VAV) Box Control, Barometric Pressure and Altimeter Instrumentation, Industrial Process Controller Low-Pressure Loop, Washing Machine and Dishwasher Water Level Sensing, Robotic and Drone Airspeed / Pitot-Static Sensing.

💊

Medical Ventilator and Respirator Pressure Monitoring

The MPX2010GS is well suited to medical ventilator and respirator pressure monitoring because its 0-10 kPa (1.45 psi) range matches the low airway-pressure transients found in CPAP, BiPAP, and anesthesia circuits. Its on-chip temperature compensation from -40C to +125C keeps span and offset drift within +/-1% across clinical thermal environments, while the Wheatstone-bridge 0-25 mV output at 10 V excitation is easily amplified to a usable 0-5 V rail by an INA125 instrumentation amplifier placed adjacent to the SIP port. Unlike higher-range transducers, the MPX2010GS gives millibar resolution at the typical 5-30 mbar breathing pressure without saturating the front end, and its vented reference inherently rejects barometric shifts that would otherwise appear as patient-pressure error.

🏭

HVAC Variable Air Volume (VAV) Box Control

The MPX2010GS fits HVAC variable-air-volume box control where duct differential pressure typically ranges from 0 to 1.5 inches water column (about 0.4 kPa full-scale). With its 0-10 kPa range and 2.5 mV/kPa sensitivity, the sensor resolves fractions of a Pascal at the low signal levels where VAV controllers operate, while its vented-gauge reference auto-compensates for altitude and barometric shifts in rooftop installations. The 4-SIP barbed tube port accepts standard 4.93 mm pneumatic tubing used in duct manifolds, and the 10-16 V supply range aligns with 24 VAC-rectified control boards. The +/-1% calibrated accuracy is sufficient for closed-loop damper control without on-board linearization.

✈️

Barometric Pressure and Altimeter Instrumentation

For hobbyist altimeters, drone altitude hold, and weather-station barometers, the MPX2010GS provides a calibrated 0-10 kPa gauge output that is conveniently zero-referenced at sea level through its vent port. The 2.5 mV/kPa sensitivity gives roughly 25 microvolts per meter of altitude change near sea level when read with a low-noise 24-bit ADC (e.g., ADS1220), enabling sub-meter altitude resolution without external amplification. The hermetic SIP-4 housing protects the silicon diaphragm from humidity and condensation encountered in outdoor enclosures, and the on-chip temperature compensation suppresses the 0-25 mV output drift that would otherwise corrupt altitude readings across a -20C to +60C weather range.

🏭

Industrial Process Controller Low-Pressure Loop

The MPX2010GS serves in industrial process controllers monitoring low-pressure gas or pneumatic lines in the 0-10 kPa range, such as cleanroom pressure cascades, glove-box overpressure regulation, and natural-gas leak detection circuits. Its calibrated 0-25 mV bridge output integrates directly with 4-20 mA loop transmitters built around XTR105 or XTR106, allowing two-wire industrial transmission back to PLCs and DCS systems. The 10-16 V supply range is compatible with 24 VDC industrial rails, and the SIP mounting with barbed port simplifies pneumatic plumbing in standard 4.93 mm tubing manifolds common in process skids.

🏭

Washing Machine and Dishwasher Water Level Sensing

Consumer washing machines and dishwashers use the MPX2010GS for water-level (or air-trapped pressure) sensing, where 0-10 kPa covers the typical 0-1 m water column range. The vented-gauge reference automatically subtracts atmospheric pressure, so day-to-day barometric shifts do not affect fill-level calibration. The on-chip temperature compensation handles the 5C-60C wash-water environment without recalibration, and the 4-SIP barbed port connects directly to the air-trap tube used in appliance sump designs. The MPX2010GS is a higher-accuracy alternative to the discrete pressure-switches used in legacy designs, supporting multi-level wash programs via software-level thresholds.

✈️

Robotic and Drone Airspeed / Pitot-Static Sensing

Low-cost robotic and drone platforms use the MPX2010GS as a Pitot-static airspeed sensor where differential pressure across a venturi rarely exceeds 5 kPa even at 30 m/s flight speeds. Mounted in a 4-SIP module, the sensor's small footprint and barbed port simplify integration into air-data booms, and its calibrated millivolt output feeds directly into op-amp-based airspeed calculators before the MCU's ADC. The vented-gauge reference is critical here: it lets the back-side of the diaphragm see ambient (static) pressure while the front side sees stagnation (total) pressure, yielding true differential pressure when the two ports are connected to the appropriate Pitot tube taps.

What is the operating pressure range of the MPX2010GS?
The NXP MPX2010GS operates from 0 kPa to 10 kPa (0 psi to 1.45 psi) in vented-gauge mode. According to the MPX2010 datasheet, the part is calibrated at 10 V excitation to deliver 0 mV at zero pressure and 25 mV at full-scale 10 kPa. The vented-gauge port references the back side of the diaphragm to atmosphere through the SIP housing, so output reflects gauge rather than absolute pressure.
What supply voltage does the MPX2010GS require?
The MPX2010GS requires a supply voltage between 10 V and 16 V for the integrated Wheatstone-bridge excitation. The output span scales linearly with supply, so a 10 V regulated excitation is the standard calibration point and yields 25 mV full-scale at 10 kPa. Using 16 V instead raises full-scale output to about 40 mV and proportionally increases sensitivity to supply noise, so a clean, low-ripple source is critical.
Is the MPX2010GS obsolete?
Yes, the MPX2010GS is listed as obsolete on NXP's part database and on distributor listings (Octopart, ABC Semiconductor). The NXP MPX2010 family was originally released by Motorola, then transferred to Freescale, and is now under NXP. Functional equivalents and newer MPX-series successors exist; consult the alternatives section for drop-in candidates.
What is the pinout of the MPX2010GS 4-SIP module?
The MPX2010GS uses a 4-lead Single-Inline Package (SIP-4) where pins 1 and 2 are the bridge output (Vout+ and Vout-) and pins 3 and 4 are the supply (Vs+ and GND-). The vent port on the housing is the gauge reference to atmosphere. Pin numbering follows NXP's MPX-series convention with pin 1 marked by the chamfered corner on the SIP body; consult the package diagram on the datasheet.
What is the difference between MPX2010GS and MPX2010DP?
The MPX2010GS measures gauge pressure (vented to atmosphere through the housing port) in a 4-SIP module, while the MPX2010DP measures differential pressure across two ports in a similar 4-SIP package. Both share 0 to 10 kPa range, 0 to 25 mV output at 10 V, and the same on-chip temperature compensation, so they are electrically drop-in but pneumatically different; do not swap them in a gauge vs differential system without re-routing the pneumatic plumbing.
Where can I buy the MPX2010GS online?
The MPX2010GS is listed as obsolete by NXP, but authorized distributors including DigiKey, Mouser, and Octopart-aggregated resellers (Jotrin, OMO Electronic, Partstack) may still carry stock. Lead times and pricing as of 2026-10-15 vary widely because of the obsolete status; expect 4-12 week lead times at distributors. Confirm RoHS compliance and date code with the supplier before placing volume orders.
What is the price of the MPX2010GS?
Pricing for the MPX2010GS as of 2026-10-15 ranges from approximately USD 15 to USD 30 per piece depending on quantity and distributor, with volume breaks at 100, 500, and 1000 units. Obsolete-stock pricing typically rises above original MSRP because of scarcity; check Octopart's aggregated 6-distributor view for the live market. Newer MPX-series successors in the same range are usually lower cost.
What is the lead time for the MPX2010GS?
Lead time for the obsolete MPX2010GS as of 2026-10-15 is typically 4 to 12 weeks from authorized distributors, depending on whether the stock is factory remainder, distributor overstock, or brokered. NXP itself no longer manufactures the MPX2010GS. For new designs, choose the MPX5010 or MPX5700 series instead of relying on MPX2010GS remainder inventory.
Is the MPX2010GS in stock at major distributors?
As of 2026-10-15 the MPX2010GS is listed at DigiKey, Mouser, Octopart-aggregated sellers, and ABC Semiconductor with limited stock marked as obsolete. Inventory is fluctuating because the part is end-of-life. Contact distributors directly for live stock counts; for production designs, the NXP MPX5010 or MPX5700 series is recommended as a successor.
What can replace the MPX2010GS as a drop-in?
Drop-in replacements in the same 4-SIP gauge-pressure format include the NXP MPX2010GVS (different port orientation, same electrical output) and the NXP MPX5010GS at higher range. Both share 4-SIP pinout and 0-25 mV-class output, allowing PCB reuse. Confirm the pressure range and port style of any alternative before substituting; gauge vs differential vs absolute sensors are not pneumatically interchangeable.
Where do I download the MPX2010GS datasheet PDF?
The MPX2010GS datasheet PDF can be downloaded from NXP's product documentation portal, from distributor document servers (DigiKey, Mouser), or from archive sites such as Alldatasheet and DatasheetQ that host the original Motorola/Freescale/NXP revisions. The most recent NXP-marked PDF supersedes earlier Motorola and Freescale datasheets; electrical specs are identical across revisions.
MPX2010GS vs MPX2053DP - which is better for differential pressure?
For differential-pressure applications the MPX2053DP is the correct choice; the MPX2010GS is a vented-gauge sensor and cannot be used in differential mode without an external reference. The MPX2053DP measures 0 to 50 kPa differential in a 4-SIP package at 0.8 mV/kPa sensitivity, while the MPX2010GS measures 0 to 10 kPa gauge at 2.5 mV/kPa sensitivity. Choose by pressure type first, then by range.
When should I choose MPX2010GS over MPX2100GP?
Choose the MPX2010GS over the MPX2100GP when your application requires a 10 kPa (low-pressure, near-atmospheric) range, such as HVAC VAV, medical respiration, or altimetry. Choose the MPX2100GP when you need a 100 kPa range for higher-pressure measurement like hydraulic or pneumatic systems. Both are 4-SIP gauge sensors with the same output span; the MPX2010GS has 2.5x higher sensitivity per kPa because of its lower full-scale.
Is the MPX2010GS RoHS compliant?
The MPX2010GS datasheet does not explicitly state RoHS compliance in the verified document set, so RoHS status is marked unknown and confirmed only by checking the specific date code with the supplier. Earlier Motorola and Freescale lots of the MPX2010 family predate RoHS in some cases; later NXP-marked lots may be compliant. Request the latest Certificate of Compliance from your distributor for production orders.
What are the key specifications of MPX2010GS that engineers should know?
The MPX2010GS is a 0 to 10 kPa (1.45 psi) vented-gauge piezoresistive pressure sensor in a 4-SIP module with 0 to 25 mV analog output at 10 V excitation, 10 V to 16 V supply range, +/-1% accuracy, and on-chip temperature compensation from -40C to +125C. It uses a barbed 4.93 mm male tube port. The part is currently obsolete but remains broadly available through distributor stock channels as of 2026-10-15.

工程参考数据: MPX2010GS ——对比、设计指导和合规信息。

选型指南

Choose the MPX2010GS for low-pressure (0-10 kPa) gauge measurements where you want raw bridge output (0-25 mV at 10 V) and external signal-chain flexibility, in applications such as medical respiration, HVAC VAV control, altimetry, and appliance water-level sensing. Choose the MPX2010GVS in the same 4-SIP gauge family if your PCB layout needs a vertical port orientation. Choose the MPX5010GS instead if you want integrated 0.2-4.7 V signal conditioning to eliminate the external instrumentation amplifier and accept 5 V supply. Choose the MPX5050GP for higher 0-50 kPa pressure ranges. All four share the 4-SIP footprint, but note that the MPX2010GS is now obsolete; new designs should prefer the active MPX5010GS or MPX5050GP unless the obsolete part's specific raw-bridge output is required.

与替代料对比

参数 本产品 MPX2010GVS MPX2010DP MPX5010GS MPX5050GP
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 4-SIP Module 4-SIP Module - same 4-SIP Module - same 4-SIP Module - same 4-SIP Module - same
Pressure Type Vented Gauge Vented Gauge Differential Gauge Gauge
Operating Pressure 0 to 10 kPa (1.45 psi) 0 to 10 kPa 0 to 10 kPa 0 to 10 kPa 0 to 50 kPa
Output 0 to 25 mV at 10 V 0 to 25 mV at 10 V 0 to 25 mV at 10 V 0.2 to 4.7 V (conditioned) 0.2 to 4.7 V (conditioned)
Supply Voltage 10 V to 16 V 10 V to 16 V 10 V to 16 V 5 V (conditioned) 5 V (conditioned)
Sensitivity 2.5 mV/kPa 2.5 mV/kPa 2.5 mV/kPa 450 mV/kPa (conditioned) 90 mV/kPa (conditioned)
Integrated Signal Conditioning No (raw bridge) No (raw bridge) No (raw bridge) Yes (calibrated 0.2-4.7 V) Yes (calibrated 0.2-4.7 V)
Lifecycle Obsolete Obsolete Obsolete Active Active

关键差异点

  • Low-pressure 10 kPa range with high 2.5 mV/kPa sensitivity (对比 MPX5050GP)
  • Raw Wheatstone bridge output allows flexible external signal conditioning (对比 MPX5010GS)
  • Vented-gauge reference rejects barometric shifts (对比 MPX2010DP)

设计说明

The MPX2010GS bridge output span scales linearly with excitation voltage: a 10 V regulated source is the standard calibration reference and yields 25 mV full-scale at 10 kPa; a 16 V source raises full-scale to roughly 40 mV. Any noise or drift on the excitation voltage is reflected directly in the output, so use a low-noise LDO (e.g., LP2985, TPS7A47) rather than a switching regulator for the bridge supply. Place a 100 nF ceramic bypass capacitor within 5 mm of pins 3 and 4.

The 0-25 mV bridge signal is small and easily corrupted by thermocouple effects and ground loops. Use an instrumentation amplifier (e.g., INA125, AD620) placed adjacent to the SIP module with twisted-pair or shielded routing from pins 1 and 2 to the INA inputs. Estimated: for the MPX2010GS at 2.5 mV/kPa and an INA125 with gain 100, expect roughly 2.5 V full-scale output per 10 kPa, well-suited to a 0-5 V ADC input.

Do not apply pressure exceeding the maximum overpressure rating of the MPX2010GS - the die or housing will rupture. Do not confuse the MPX2010GS (vented gauge) with the MPX2010DP (differential) - they are electrically drop-in but pneumatically incompatible. Do not power the sensor below 10 V or above 16 V; below 10 V the output span scales down proportionally and the S/N ratio suffers; above 16 V the die may overheat and the calibration shifts.

Mount the MPX2010GS vertically with the barbed port pointing upward to prevent condensate from pooling on the silicon diaphragm. Keep the vent holes on the SIP housing clear of conformal coating or potting compound - blocked vents destroy the gauge reference. Provide strain relief for the pneumatic tubing so vibration cannot fatigue the barbed port.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

MPX2010GS originally released by Motorola then transferred through Freescale to NXP. RoHS, REACH, and lead-free status were not present in the verified web data set; request the latest CoC from the supplier for production orders. AEC-Q100 not applicable for board-mount sensors in non-automotive applications.

数据核验日期: 2026-10-15 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

MPX2010GS datasheet MPX2010GS price MPX2010GS equivalent 10 kPa piezoresistive pressure sensor SIP-4 vented gauge pressure sensor NXP MPX2010GS medical ventilator MPX2010GS HVAC VAV MPX2010GS vs MPX5010 MPX2010GS drop-in replacement buy MPX2010GS obsolete stock what is the output of MPX2010GS MPX2010GS pinout 4-SIP

相关元器件 & 术语

NXP Semiconductors Freescale Semiconductor Motorola MPX2010GS MPX2010GVS MPX2010DP MPX5010GS MPX5050GP piezoresistive pressure sensor Wheatstone bridge vented gauge pressure sensor silicon pressure sensor 4-SIP Module barbed pneumatic port on-chip temperature compensation transducer instrumentation amplifier INA125 HVAC VAV controller medical ventilator altimeter AEC-Q100 RoHS
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情