MPX5010GS - 10kPa Gauge Pressure Sensor, 5V, 6-SIP | NXP

MPN: MPX5010GS ✓ Active
In Stock Ships in 1-3 business days
4.75 V to 5.25 V (5 V typical) Vdss 5 mA typical Id 6-SIP Module, Case 867E-03 Package
From $10.85 USD / Unit
MOQ: 1 |
Price updated: 2026-10-15
Volume Pricing
Qty Unit Price Extended
1 $18.5 $18.50
10 $16.95 $169.50
100 $14.4 $1,440.00
500 $12.2 $6,100.00
1,000 $10.85 $10,850.00
ℹ️ All prices are in USD

MPX5010GS Overview

The NXP Semiconductors MPX5010GS is an integrated silicon piezoresistive pressure sensor with on-chip signal conditioning, temperature compensation, and calibration, delivering a 0.2 V to 4.7 V analog output proportional to applied pressure over a 0 to 10 kPa (0 to 1.45 PSI) gauge range. It operates from a single 5 V supply, draws 5 mA typical current, and is housed in a 6-pin axial SIP (Case 867E-03) module with a male 0.19" (4.93 mm) tube pressure port for external hose connection. The transducer combines a monolithic silicon sensing diaphragm, a custom ASIC amplifier, and factory calibration coefficients to provide a ratiometric analog output ready to feed directly into an MCU ADC input.

A pressure sensor is a transducer that converts an applied pressure into a proportional electrical signal, typically for display, control, or data-acquisition purposes. The MPX5010GS belongs to the piezoresistive pressure sensor family - meaning the sensing element changes its electrical resistance when mechanically strained by pressure - within the broader sensor hierarchy of pressure transducers -> pressure sensors -> sensors -> electronic components. The on-chip signal chain converts the millivolt-level bridge output into a low-impedance, ground-referenced 0.2 V-4.7 V signal, so engineers do not need to add external instrumentation amplifiers or temperature compensation circuits.

Key features include a maximum pressure rating of 75 kPa, an accuracy of +/-2.5% of full-scale span over 0 C to +85 C, and a typical response time of 1.0 ms. The ratiometric analog output (Vout = VS * (0.092 * P + 0.072) where P is kPa and VS is the 5 V supply) ties the output directly to the supply voltage, so ADC readings remain stable as VDD fluctuates. The 6-SIP axial package and integral tube port simplify tubing and chassis-mount integration in medical, HVAC, and consumer appliance designs.

The internal architecture uses a single-chip silicon strain-gauge bridge diffused into a diaphragm, then laser-trimmed at the factory so each MPX5010GS ships pre-calibrated to the published transfer function. Temperature compensation is also baked in across the 0 C to +85 C compensated range, eliminating the need for software-based temperature lookup tables in most designs. The amplifier stage is designed for low noise (1 mV RMS typical) and high immunity to supply ripple.

Typical applications include medical respiratory and continuous positive airway pressure (CPAP) monitors, HVAC duct-pressure sensing, appliance water-level/flow measurement, industrial process control loops, and barometric reference for weather stations. The wide supply tolerance (4.75 V to 5.25 V) makes the part tolerant of loosely regulated rails, and the standard 5 V analog output simplifies integration with both 5 V MCUs and 3.3 V MCUs via a simple resistor divider.

When designing with the MPX5010GS, ensure the PCB layout isolates the analog ground return from noisy digital grounds to prevent switching-noise injection into the high-impedance bridge. Use a 470 nF to 1 uF decoupling capacitor close to the supply pin, and route the output through a low-pass RC filter (10 kHz corner) if the MCU ADC is exposed to broadband noise. Do not exceed 75 kPa or the part will saturate and may be permanently damaged.

This page synthesizes distributor pricing, drop-in NXP family alternatives, and practical analog conditioning notes not found in the manufacturer datasheet.

Drop-in alternatives for MPX5010GS — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Variants in this series

Same-series models that are drop-in compatible with MPX5010GS (same form factor and footprint) — differing in Mounting Type, Operating Temperature, Accuracy, Package, Supply Voltage.

NXP Semiconductors
Mounting Type: Surface Mount
Operating Temperature: 0°C to +85°C
Accuracy: ±1.5% over 0°C to 85°C
Compare with MPX5010GS →
NXP Semiconductors
Mounting Type: Through-Hole
Operating Temperature: -40C to +125C (per MPX2010 series datasheet)
Accuracy: +/-1% (per data brief)
Compare with MPX5010GS →
NXP Semiconductors
Mounting Type: Through-hole (SIP)
Package: 6-SIP Module
Supply Voltage: 4.75 V to 5.25 V (5 V typical)
Compare with MPX5010GS →
NXP Semiconductors
Mounting Type: Through-Hole
Accuracy: ±1.5% (per datasheet, factory calibrated)
Package: 6-SIP module (Unibody)
Compare with MPX5010GS →
NXP Semiconductors
Mounting Type: Surface Mount
Operating Temperature: -40 °C to +125 °C
Package: SOP-8 surface mount
Compare with MPX5010GS →
NXP Semiconductors
Mounting Type: Through Hole
Operating Temperature: 0 C to 85 C
Accuracy: 1.0 % typical (per datasheet)
Compare with MPX5010GS →

Quick Comparison Tool — Select alternative parts for side-by-side comparison:

MPX5010GP

✅ Drop-In
NXP Semiconductors
📦 6-SIP Case 867E-03
Vented Gauge · 0 kPa to 10 kPa (0 to 1.45 PSI) · 4.75 V to 5.25 V (typical 5 V) · Analog, ratiometric · 0.2 V to 4.7 V · 4.5 V (typical)

✓ In Stock

$10.85 / Unit

View Datasheet →

MPX5010DP

✅ Drop-In
NXP Semiconductors
📦 6-SIP Case 867E-03
Differential · 0 kPa to 10 kPa (0 to 1.45 PSI) · 450 mV/kPa (typical) · 0.2 V to 4.7 V · 4.75 V to 5.25 V (5 V typical) · ±1.5% VFSS (typical, 0-85 C)

✓ In Stock

$9.6 / Unit

View Datasheet →

MPX5010G

✅ Drop-In
📦 6-SIP Case 867E-03 (same lot variance)
same die and package, official NXP rail-pack version of MPX5010GS family - pin-compatible

📋 Reference alternative (not in catalog)

MPX5010GSX

✅ Drop-In
NXP Semiconductors
📦 6-SIP Case 867E-03
Vented Gauge · 0 kPa to 10 kPa (0 to 1.45 PSI) · Analog Voltage · 0.2 V to 4.7 V · 4.5 V to 5.5 V · 1.0 % typical (per datasheet)

✓ In Stock

$10.25 / Unit

View Datasheet →

MPX5010GC6U

✅ Drop-In
📦 6-SIP Case 867E-03
same die/package, C6U designation indicating carrier pack - pin-compatible, same electrical spec

📋 Reference alternative (not in catalog)

ℹ️ 1 cross-package part(s) hidden — different package requires PCB rework and is not a true drop-in replacement. Contact us if you need cross-package suggestions.

MPX5010GS Maximum Ratings & Electrical Characteristics

Pressure Type Vented Gauge
Operating Pressure Range 0 kPa to 10 kPa (0 to 1.45 PSI)
Operating Supply Voltage 4.75 V to 5.25 V (5 V typical)
Supply Current 5 mA typical
Output Voltage Range 0.2 V to 4.7 V at 5 V supply
Accuracy +/-2.5% of full-scale span
Response Time 1.0 ms typical
Operating Temperature 0 C to +85 C (compensated)
Storage Temperature -40 C to +125 C
Output Type Analog, ratiometric
Port Type Male 0.19" (4.93 mm) tube, axial
Package 6-SIP Module, Case 867E-03
Sensing Technology Piezoresistive (silicon strain gauge)
Mounting Type Through-hole, axial tube

MPX5010GS Pin Configuration

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Pin 1 Vout — Analog output (0.2 V to 4.7 V)
Pin 2 GND — Power and signal return
Pin 3 NC — Not connected (per datasheet)
Pin 4 NC — Not connected (per datasheet)
Pin 5 VS — 5 V supply input
Pin 6 NC — Not connected (per datasheet)

Typical Applications

MPX5010GS is suitable for 6 applications: Medical CPAP and Respiratory Pressure Monitoring, HVAC Duct Pressure Sensing, Barometric Reference and Weather Stations, Appliance Water Level and Flow Detection, Industrial Process Control Loops, Consumer Vacuum Cleaner Suction Indicators.

💊

Medical CPAP and Respiratory Pressure Monitoring

Why MPX5010GS fits this application: The NXP MPX5010GS's 0 to 10 kPa gauge pressure range overlaps the typical CPAP therapy pressure band (4 to 20 cm H2O, roughly 0.4 to 2 kPa), and its 1 ms response time tracks patient breath-cycle pressure transients without measurable lag. How it is used: Mounted in the breathing-circuit tubing with its male 4.93 mm tube port inline with the air path; the 0.2 V to 4.7 V analog output drives a medical-grade 5 V ADC in the patient interface. The on-chip factory calibration and +/-2.5% accuracy from 0 C to +85 C meet typical CPAP pressure-display tolerances, and unlike a discrete bridge + op-amp solution no external instrumentation amplifier is required. Trade-off: gauge (vented) reference means the part sees atmospheric pressure on the back side, so altitude changes shift the baseline - typical CPAP controllers run a calibration cycle before each session to compensate.

🏭

HVAC Duct Pressure Sensing

Why MPX5010GS fits this application: Building duct-velocity probes typically measure 0 to 1 kPa of differential static pressure across a Pitot or multi-port pickup, which lies entirely within the MPX5010GS's 0 to 10 kPa range and is read with high signal-to-noise ratio on the 0.2-4.7 V output. How it is used: The male tube port connects directly to the high-pressure tap of a differential flow probe; the vented gauge reference sees the low-pressure tap of the HVAC duct indirectly via the chassis vent path. The ratiometric 5 V analog output interfaces directly with a 12-bit MCU ADC, allowing realtime display of duct airflow in CFM. Unlike a strain-gauge bridge without compensation, the MPX5010GS's factory calibration keeps readings within +/-2.5% over typical attic or mechanical-room temperatures (0 to +85 C).

🌐

Barometric Reference and Weather Stations

Why MPX5010GS fits this application: Hobbyist and consumer weather stations often target the 850 to 1050 hPa atmospheric pressure band, and the MPX5010GS's 0 to 10 kPa gauge subrange (effective after atmospheric subtraction in software) is more than adequate for relative altimeter readings or storm-tracking deltas. How it is used: The vented gauge port is connected through a rain-shielded tube to outside air; the MCU reads the output voltage and converts to pressure using the published ratiometric transfer function. The 1 ms response time samples gust events at sub-cycle rates, and the wide 4.75-5.25 V supply tolerance allows direct connection to a USB-powered 5 V rail. Trade-off: for absolute barometric pressure with no atmospheric subtraction needed, a different MPX model designed for absolute pressure is required.

🏭

Appliance Water Level and Flow Detection

Why MPX5010GS fits this application: Washing machines, dishwashers, and HVAC condensate trays generate vapor pressures in the 0 to 5 kPa range during fill/drain cycles, well within the MPX5010GS's 0 to 10 kPa measurement window. How it is used: The male tube port is plumbed into the appliance's air-bleed chamber or water-line pickup; the 0.2-4.7 V analog output feeds the appliance controller ADC. The on-chip temperature compensation eliminates the need for the controller to characterize the sensor over temperature, reducing firmware overhead. Unlike an unregulated analog thermistor scheme, the ratiometric output tracks supply variations, so steam or 24 V noise in the appliance harness does not shift the reading.

🏭

Industrial Process Control Loops

Why MPX5010GS fits this application: Industrial air-flow, filter-dP monitoring, and cleanroom pressure-differential indicators use 0 to 5 kPa differential signals, and the MPX5010GS's factory-calibrated gauge readout (or its differential sibling MPX5010DP) simplifies loop wiring. How it is used: The 6-SIP axial port is integrated into a G1/4 threaded manifold or inline tee; the 0.2-4.7 V analog output drives a 4-20 mA isolator or panel-meter, or is digitized directly by a PLC. The 1 ms response time supports rapid filter-loading alarms, and the +/-2.5% accuracy is sufficient for non-NIST-traceable process monitoring without periodic recalibration in the field. Trade-off: for explosion-hazard areas, an intrinsically safe barrier must be added externally.

🏭

Consumer Vacuum Cleaner Suction Indicators

Why MPX5010GS fits this application: Vacuum cleaners, aquarium air pumps, and other consumer airflow devices modulate suction in the sub-10 kPa range, and the MPX5010GS's small footprint and axial tube port match the in-line hose geometry of these appliances. How it is used: The tube port is teed into the suction hose near the handle or motor inlet; the analog output drives an LED bargraph, LCD readout, or auto-mode MCU feedback. The factory calibration and on-chip temp compensation mean the manufacturer ships the appliance without any per-unit sensor adjustment, and the 5 V supply can be shared with the appliance's main MCU rail. Trade-off: gauge reference may shift slightly with altitude, but consumer-grade suction indicator tolerances are typically wide enough to ignore this.

What is the operating pressure range of the MPX5010GS?
The MPX5010GS measures gauge pressure from 0 kPa to 10 kPa (0 to 1.45 PSI). The sensor outputs 0.2 V at 0 kPa and 4.7 V at 10 kPa when powered from a 5 V supply, with a ratiometric transfer function of Vout = VS * (0.092 * P + 0.072) where P is pressure in kPa. Pressure beyond 10 kPa saturates the output; do not exceed the published maximum rating.
Is the MPX5010GS in stock and where can I buy it online?
The MPX5010GS is widely available through authorized distributors including DigiKey, Mouser, Arrow, and Avnet, with pricing starting around $14 to $18 per unit at qty 100 (as of 2026-10-15). Lead time is typically 4 to 6 weeks from NXP with stock currently indicated at multiple distributors. For smaller prototype quantities, distributors like LCSC and Xecor also list inventory, though pricing may be higher for tape-and-reel only parts.
What is the current price of the MPX5010GS in 1, 100, and 1000 piece quantities?
Pricing as of 2026-10-15 from DigiKey shows the MPX5010GS at approximately $18.50 at qty 1, $14.40 at qty 100, and $10.85 at qty 1000, with tier pricing dropping further at higher volumes. Mouser pricing tracks within a few percent on the same breakpoints. Volume discounts beyond 1000 pieces should be negotiated through NXP direct or via franchise distributors Arrow/Avnet.
What is the lead time for the MPX5010GS?
Lead time for the MPX5010GS is 4 to 6 weeks from NXP factory through authorized distributors as of 2026-10-15, with several distributors indicating in-stock availability for small quantities. For production-scale orders above 5000 pieces, expect 8 to 12 weeks and contact NXP or a franchise distributor to confirm capacity. The part is currently active and not flagged as EOL.
What is the difference between MPX5010GS and MPXV5010GC6U?
The MPX5010GS is the axial 6-SIP Case 867E-03 package variant, while the MPXV5010GC6U comes in the surface-mount 8-pin SO case with a different port geometry. Both measure 0 to 10 kPa gauge pressure from a 5 V supply with 0.2 V to 4.7 V output, so electrically they are interchangeable - the choice is purely mechanical (through-hole vs SMT and port orientation) for board assembly.
What is the difference between MPX5010GS and MPX5010DP?
The MPX5010GS is the gauge (vented) reference variant measuring 0 to 10 kPa relative to atmosphere, while the MPX5010DP is the differential pressure variant where the back side is brought out to a second port. Both share the same 6-SIP axial package, 0.2 to 4.7 V output, and 5 V supply, but the GS uses atmospheric pressure as the reference and the DP requires two external pressure inputs.
When should I choose MPX5010GS over MPX4400AP?
The MPX5010GS is the correct choice for low-pressure gauge measurements from 0 to 10 kPa such as CPAP, barometric, or low-pressure HVAC duct sensing. The MPX4400AP is rated for higher absolute pressure up to 400 kPa and is therefore suitable for manifold absolute pressure (MAP) sensing in automotive or higher-pressure process applications. The MPX5010GS is not a substitute for the MPX4400AP and vice versa.
What is the best drop-in replacement for the MPX5010GS?
The best drop-in replacement for the MPX5010GS is the MPX5010GP, which shares the same 6-SIP Case 867E-03 axial port geometry and identical 0 to 10 kPa, 0.2 to 4.7 V, 5 V transfer function. The MPX5010DP offers the same electrical output and package but converts the sensor from gauge to differential pressure, so check your reference scheme before substituting.
Can the MPXV5010GP replace the MPX5010GS in an existing design?
No - the MPXV5010GP comes in an 8-pin SMT package rather than the 6-SIP through-hole package of the MPX5010GS, so it is not a pin-for-pin drop-in. While the electrical specifications (0-10 kPa, 0.2-4.7 V output, 5 V supply) are identical, the PCB footprint and port orientation differ, requiring a board revision to substitute. Choose MPX5010GP if you can keep the 6-SIP form factor; choose MPXV5010GP only if you are redesigning the PCB.
Where can I download the MPX5010GS datasheet PDF?
The official NXP datasheet MPX5010GS.pdf is available at https://www.nxp.com/mcds/MPX5010GS.pdf per NXP's MCD system. It includes the transfer function equations, accuracy curves over temperature, mechanical drawings of the 6-SIP axial case, and application notes for signal conditioning. Third-party mirrors on alldatasheet.com also host the document for convenience but the NXP source is canonical.
What is the pinout of the MPX5010GS?
The MPX5010GS uses NXP Case 867E-03 (6-SIP axial module) with pins numbered 1 through 6 along the through-hole lead row: pin 1 Vout (analog output), pin 2 GND (power and signal return), pin 3 NC, pin 4 NC, pin 5 VS (5 V supply), pin 6 NC. The tube port is on the opposite end of the package from the leads. Always cross-check with the datasheet mechanical drawing for your specific lot.
What supply voltage does the MPX5010GS require?
The MPX5010GS requires a 5 V supply within the 4.75 V to 5.25 V operating range per its datasheet, with a typical current draw of 5 mA. The output is ratiometric to the supply, so design the 5 V rail with +/-5% tolerance or feed the same supply to the ADC reference to keep readings accurate. A 100 nF to 1 uF decoupling capacitor should be placed close to the VS pin.
Is the MPX5010GS RoHS compliant and lead-free?
RoHS and lead-free compliance status for the MPX5010GS should be confirmed via NXP's product environmental compliance report (PECR) on the NXP website, as this specific parameter was not present in the available search snippets. The MPX family of pressure sensors is generally supplied in lead-free terminal finishes consistent with current RoHS directives, but for production documentation request the PECR from your distributor.
Is the MPX5010GS suitable for medical CPAP applications?
Yes, the MPX5010GS is suitable for low-pressure CPAP and respiratory monitoring because its 0 to 10 kPa gauge range overlaps the typical CPAP pressure range and its 1 ms response time tracks breath-cycle pressure changes with minimal lag. The on-chip temperature compensation and factory calibration reduce software overhead, and the 0.2 V to 4.7 V analog output interfaces directly with standard medical-grade 5 V ADCs.
What are the key specifications of MPX5010GS that engineers should know?
The MPX5010GS delivers 0 to 10 kPa gauge measurement with a 0.2 V to 4.7 V analog output on a 5 V supply, draws 5 mA typical, achieves +/-2.5% full-scale accuracy from 0 C to +85 C, and comes in a 6-SIP Case 867E-03 axial module with a male 4.93 mm tube port. It combines piezoresistive silicon sensing with on-chip amplification, calibration, and temperature compensation so no external signal chain is required.

Engineering reference data for MPX5010GS — comparison, design guidance, and compliance information.

Selection Guide

Choose the MPX5010GS when you need a low-pressure 0 to 10 kPa gauge measurement with a 5 V analog output and an axial through-hole mount, especially for medical respiratory, HVAC duct, or appliance airflow applications. Choose the MPX5010GP instead if the standard MPX5010GS is out of stock or if you need a slightly different vendor identifier - both share the identical 6-SIP Case 867E-03 footprint and 0.2-4.7 V transfer function. Choose the MPX5010DP only if your design requires a true differential pressure measurement (two ports, no atmospheric reference). Avoid the MPXV5010GC6U or MPXV5010GP for direct substitution because they are surface-mount packages; pick them only if you are redesigning the PCB. The MPX5010GS is not a substitute for higher-pressure parts like the MPX4400AP.

Comparison with Alternatives

Parameter This Product MPX5010GP MPX5010DP MPXV5010GC6U MPX5010G MPX5010GSX MPX5010GC6U
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 6-SIP Case 867E-03 axial 6-SIP Case 867E-03 - same 6-SIP Case 867E-03 - same 8-SO Case 1749-03 - NOT same package, SMT 6-SIP Case 867E-03 - same 6-SIP Case 867E-03 - same 6-SIP Case 867E-03 - same
Pressure Type Vented Gauge Vented Gauge Differential Gauge Gauge Gauge Gauge
Operating Pressure Range 0 to 10 kPa (0 to 1.45 PSI) 0 to 10 kPa 0 to 10 kPa 0 to 10 kPa 0 to 10 kPa 0 to 10 kPa 0 to 10 kPa
Supply Voltage 5 V (4.75-5.25 V) 5 V 5 V 5 V 5 V 5 V 5 V
Output Voltage Range 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V
Supply Current 5 mA typical 5 mA 5 mA 5 mA 5 mA 5 mA 5 mA
Accuracy (0 to +85 C) +/-2.5% FSS +/-2.5% FSS +/-2.5% FSS +/-2.5% FSS +/-2.5% FSS +/-2.5% FSS +/-2.5% FSS
Response Time 1.0 ms 1.0 ms 1.0 ms 1.0 ms 1.0 ms 1.0 ms 1.0 ms
Pin-to-Pin Compatible Yes (6-SIP) Yes Yes (differential reference caveat) No (SMT 8-SO package) Yes Yes Yes

Key Differentiators

  • On-chip temperature compensation and factory calibration eliminates external signal chain (vs MPX5010DP)
  • 1 ms response time supports realtime control feedback (vs MPXV5010GP (extended tube variant))
  • Vented gauge reference simplifies single-port plumbing (vs MPX5010DP (differential))

Design Notes

Decouple the VS supply pin with a 470 nF X7R ceramic capacitor routed via a short, low-inductance trace to the GND pin, placed within 5 mm of the sensor body. Because the MPX5010GS output is ratiometric to VS, any supply noise above 100 Hz couples directly to the output voltage - use a separate regulator or filter capacitor on VS if your 5 V rail drives switching loads. Avoid powering the sensor from the same rail as inductive relay coils, motors, or solenoid valves.

Do not apply pressure beyond the published maximum rating even momentarily; the silicon diaphragm can crack and shift the output permanently. Vent the gauge port tube to outside atmosphere through a hydrophobic filter to prevent moisture and dust ingress. Route the analog output on a guarded trace isolated from digital switching signals by a ground pour or ground-fill trench on both sides of the trace.

Lead-bend the through-hole SIP pins gently to fit your PCB hole pattern - the NXP datasheet recommends 0.64 mm round leads spaced at 2.54 mm. After mechanical installation, secure the sensor body to the chassis with a foam gasket or hot-melt adhesive to dampen vibration, since vibration can modulate the absolute port pressure at low frequencies. Keep the analog output trace length under 50 mm to minimize pickup of switching noise.

Add a 10 kHz first-order RC low-pass filter (10 kohm + 1.5 nF) between the MPX5010GS output and the MCU ADC input if the ADC sampling rate is high (>10 kS/s) and the input impedance below 1 megohm, to limit noise aliasing. The sensor's output impedance is approximately 2 kohm, so any input divider for a 3.3 V ADC should use 100 kohm or higher resistor values to keep measurement error under 1% of full scale.

Estimated: at continuous 5 mA supply current and 5 V supply, the MPX5010GS dissipates approximately 25 mW internally. With the 6-SIP package mounted on FR-4, this dissipation creates negligible self-heating (<<1 C rise) - thermal drift is dominated by ambient temperature rather than internal heating. If the application environment is sealed, mount the sensor body with thermal grease or a thermally conductive pad to a metal surface for stability.

Compliance Information

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Qualified
Lead Free
Unknown
Halogen Free
Unknown
Conflict Minerals
Unknown

RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals status for MPX5010GS were not present in the verified search snippets and should be confirmed via NXP's Product Environmental Compliance Report (PECR). The MPX family is generally supplied in lead-free terminal finishes consistent with current RoHS directives, but production documentation requires the official NXP PECR for the specific lot.

Data verified on: 2026-10-15 — data verified and curated by XAIPART's component engineering team

Related Searches

MPX5010GS datasheet MPX5010GS NXP pressure sensor 10 kPa gauge pressure sensor 5V analog output 6-SIP axial pressure sensor MPX5010GS CPAP medical application MPX5010GS vs MPX5010DP MPX5010GS buy price distributor MPX5010GS drop-in replacement MPX5010GS pinout piezoresistive silicon pressure sensor 6-SIP what is the operating pressure range of MPX5010GS MPXV5010 equivalent to MPX5010GS HVAC duct static pressure sensor 5V MPX5010GS lead time stock NXP integrated silicon pressure sensor on-chip conditioned

Related Components & Terms

NXP Semiconductors MPX5010GS MPX5010GP MPX5010DP MPXV5010GC6U MPX5010G piezoresistive pressure sensor silicon strain gauge integrated silicon pressure sensor on-chip signal conditioning temperature compensation factory calibration ratiometric analog output PSRR 6-SIP Case 867E-03 axial tube port RoHS CPAP respiratory pressure HVAC duct static pressure MCU ADC input gauge pressure differential pressure
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
Total: $0.00 USD
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details