MaxLinear

SP232AEN-L/TR - 120kbps Dual RS-232 Transceiver | MaxLinear

料号: SP232AEN-L/TR ✓ 量产中
有现货 1-3 个工作日内发货
4.5 V to 5.5 V Vdss 5 mA Id 16-lead SOIC Package
低至 $0.3941 USD / 件
最小起订量: 1 |
价格更新于: 2026-10-22
批量定价
数量 单价 小计
1 $0.3941 $0.39
10 $0.3941 $3.94
100 $0.3941 $39.41
500 $0.3941 $197.05
1,000 $0.3941 $394.10
ℹ️ 所有价格均以 USD 计价

SP232AEN-L/TR 概述

The MaxLinear SP232AEN-L/TR is a dual RS-232 line-driver and receiver interface IC supporting data rates up to 120 kbps under load, packaged in a 16-lead SOIC. The device operates from a single 4.5 V to 5.5 V supply and is specified across -40°C to +85°C. It uses a BiCMOS implementation and 0.1 µF ceramic charge-pump capacitors, allowing compact RS-232 designs without an external regulated charge-pump supply.

An RS-232 transceiver is a signal-interface semiconductor that converts logic-level UART signals into RS-232 voltage levels and converts received RS-232 levels back into logic-compatible signals. The SP232A belongs to the broader hierarchy of interface ICs, serial-interface transceivers, communication transceivers, and semiconductors. It is used where a host, controller, terminal, or embedded system must connect to a longer-distance, noise-tolerant RS-232 port.

Key features include two driver and two receiver channels, compatibility with RS-232 and V.28 protocols, a 120 kbps data rate under load, and pin-to-pin compatibility with popular industry-standard pinouts. The manufacturer datasheet identifies small 0.1 µF ceramic charge-pump capacitors as a key implementation detail. The single 5 V supply and industrial temperature range support equipment operating across industrial and commercial environments.

The BiCMOS architecture combines bipolar and CMOS characteristics in the driver and receiver circuitry. This is relevant when designing a UART link because the interface must translate between low-voltage digital logic and the larger voltage swings defined by RS-232 while maintaining receiver discrimination under cable noise. The SP232A is intended for point-to-point serial communication rather than multidrop RS-485 networks.

Typical applications include industrial serial consoles, programmable-logic-controller service ports, test instrumentation, point-of-sale equipment, barcode-scanner interfaces, and embedded UART-to-RS-232 adapters. In each case, the transceiver is placed between the UART controller and the external DB9 or other RS-232 connector, with the charge-pump capacitors and bypass capacitor placed close to the device.

For a new PCB, follow the manufacturer datasheet for the charge-pump capacitor connection, ground-return arrangement, and decoupling placement. Keep the connector-side interface trace short, provide a solid ground reference, and confirm the downstream UART baud rate and cable length. The SP232AEN-L/TR is not an RS-485 transceiver, so it should not be used where multi-drop bus arbitration and differential signaling are required.

This page combines verified distributor listings, the MaxLinear SP232A datasheet, package information, application context, and a constrained drop-in replacement review. The listed alternatives are included only where the available cross-reference evidence identifies compatible package-level substitutions; engineers should still verify speed, ESD, supply, and lifecycle requirements before production use.

直接替换替代料: SP232AEN-L/TR ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: SP232AEN-L/TR (相同外形与封装尺寸) ——差异在于 Supply Voltage, Package, ESD Protection.

MaxLinear
Supply Voltage: 5 V single supply
Package: 16-pin SOIC
ESD Protection: +/-15 kV IEC 61000-4-2 and/or +/-15 kV HBM
MaxLinear
Supply Voltage: Single +5 V supply
Package: 16-pin SOIC
ESD Protection: ±15 kV

快速对比工具——选择替代料号进行并排对比:

SP232AEN-L

✅ 直接替换
MaxLinear
📦 16-SOIC
RS-232 line transceiver · 2 · 2 · 5 V single supply · 120 kbps under load · +/-6.5 V regulated charge-pump output · 10 V/us · 0.1 uF ceramic type

✓ 有现货

联系询价

查看数据手册 →

SP232AEN-L/TR 规格参数

Device Type Dual RS-232 line driver and receiver transceiver
Protocol RS-232 and V.28
数据速率 120 kbps under load
电源电压 4.5 V to 5.5 V
Supply Type Single supply
Maximum Supply Current 5 mA
工作温度 -40°C to +85°C
Driver/Receiver Channels 2/2
Charge Pump Capacitors 0.1 µF ceramic
Architecture BiCMOS
封装 16-lead SOIC
安装类型 Surface mount
ESD Rating 2 kV
RoHS unknown
REACH unknown
AEC-Q100 not_applicable

SP232AEN-L/TR 引脚配置

SOIC-16 Package Pinout Diagram SOIC-16 16-pin, 3.9x9.9mm, P1.27mm, JEDEC MS-012. 1 16 2 15 3 14 4 13 5 12 6 11 7 10 8 9 SOIC-16
引脚 1 C1+ — Charge-pump capacitor positive terminal
引脚 2 C1- — Charge-pump capacitor negative terminal
引脚 3 V+ — Positive supply terminal
引脚 4 R1OUT — Receiver output for channel 1
引脚 5 R1IN — Receiver input for channel 1
引脚 6 T1IN — Driver input for channel 1
引脚 7 T1OUT — Driver output for channel 1
引脚 8 GND — Ground reference
引脚 9 T2OUT — Driver output for channel 2
引脚 10 T2IN — Driver input for channel 2
引脚 11 R2IN — Receiver input for channel 2
引脚 12 R2OUT — Receiver output for channel 2
引脚 13 V- — Negative charge-pump supply terminal
引脚 14 C2+ — Charge-pump capacitor positive terminal
引脚 15 C2- — Charge-pump capacitor negative terminal
引脚 16 VCC — Positive supply input

典型应用

SP232AEN-L/TR 适用于 6 应用s: Industrial UART Serial Console, Programmable Logic Controller Service Port, Test and Measurement Instrument, Point-of-Sale Terminal Interface, Embedded Data Acquisition Module, Modem and Remote Communications Link.

🏭

Industrial UART Serial Console

The SP232AEN-L/TR fits an industrial UART-to-RS-232 console when the controller operates from a single 5 V supply and the cable must carry the longer-range RS-232 voltage levels. Place the dual transceiver between the controller UART and the DB9 or terminal connector, and use the specified 0.1 µF ceramic charge-pump capacitors close to the IC. Its 120 kbps-under-load capability is suitable for service ports, configuration links, and diagnostic channels, while the -40°C to +85°C range supports equipment beyond room temperature. Confirm connector-level ESD protection and ground-return continuity because those requirements are set by the external cable and enclosure, not only by the IC.

⚙️

Programmable Logic Controller Service Port

Use the SP232AEN-L/TR as the electrical interface between a PLC’s logic-level UART and an RS-232 maintenance connector. The dual driver and dual receiver arrangement supports the transmit and receive directions required by a serial service port, and the single 4.5 V to 5.5 V supply simplifies integration with 5 V control electronics. The 120 kbps-under-load rating provides margin above many low-speed configuration protocols, but the actual baud rate must be checked against cable length and receiver timing. Follow the datasheet charge-pump capacitor placement and provide a low-impedance ground return to reduce susceptibility to common-mode noise.

🔧

Test and Measurement Instrument

The SP232AEN-L/TR can provide the RS-232 port used by test instruments, calibration tools, and laboratory equipment that exchange commands with a PC or controller. Its 2/2 channel arrangement allows bidirectional serial communication without two separate interface packages, while the 16-SOIC format supports conventional surface-mount assembly. The 120 kbps-under-load specification is adequate for many instrument-control protocols, but cable shielding, grounding, and connector shielding remain important in electrically noisy benches. Confirm the instrument’s logic levels and RS-232 polarity in software or hardware before production use.

🛒

Point-of-Sale Terminal Interface

SP232AEN-L/TR is suitable for point-of-sale peripherals that use a host UART and an RS-232 receipt printer, scanner, or customer-display interface. The single 5 V-class supply aligns with common embedded logic systems, while the dual transceiver channels support bidirectional command and status traffic. The device’s 120 kbps-under-load capability is more than adequate for typical peripheral traffic, subject to the protocol and cable length. Keep the connector-side traces short, route the return path with the signal, and add external protection if the cable leaves an industrial enclosure or connects to user-accessible equipment.

📡

Embedded Data Acquisition Module

The SP232AEN-L/TR can bridge a low-voltage embedded controller to an RS-232 data-acquisition device, modem, or remote sensor interface. Its -40°C to +85°C specification supports industrial enclosure environments, and the 2/2 architecture avoids separate logic-level-to-RS-232 conversion blocks for each direction. The 120 kbps-under-load rating supports many telemetry formats, but designers must calculate the complete link budget and observe UART oversampling requirements at the selected baud rate. Use the manufacturer’s charge-pump capacitor values and place common-mode or ESD protection at the connector boundary when cables leave the board.

🌐

Modem and Remote Communications Link

The SP232AEN-L/TR is appropriate for legacy modem, remote-maintenance, and equipment-to-host RS-232 links where a modern UART replaces older serial hardware. The single-supply 4.5 V to 5.5 V operating range and 120 kbps-under-load capability provide a straightforward interface for low- and moderate-speed serial protocols. Because RS-232 is a point-to-point, single-ended interface, cable length, ground continuity, and connector pinout must be checked carefully. External surge or ESD protection should be selected for exposed cables, and the transceiver should not be replaced by an RS-485 part without changing the system’s signaling architecture.

What is the operating voltage of SP232AEN-L/TR?
The SP232AEN-L/TR operates from a single 4.5 V to 5.5 V supply. According to the MaxLinear SP232A datasheet, the device is intended for 5 V single-supply RS-232 interface designs, while Mouser identifies the SP232AEN-L/TR as a 5 V single-supply RS-232 interface IC. Confirm the external capacitor ratings and connector-side protection before applying power.
What data rate does SP232AEN-L/TR support?
The SP232AEN-L/TR supports data rates up to 120 kbps under load. The MaxLinear manufacturer datasheet states this figure for the SP232A family and identifies the device as an RS-232 and V.28 line-driver and receiver pair. Actual UART throughput also depends on baud-rate accuracy, cable length, termination, noise, and the connected receiver.
Where can I download the SP232AEN-L/TR datasheet PDF?
The official SP232A datasheet PDF is available at https://www.maxlinear.com/ds/sp232a.pdf. It describes the BiCMOS line-driver and receiver pair, RS-232 and V.28 protocol support, 120 kbps operation under load, 0.1 µF ceramic charge-pump capacitors, and the family pinout. Distributor datasheet links may also be available through DigiKey, Mouser, and Octopart.
Is SP232AEN-L/TR a single 5 V RS-232 transceiver?
Yes. The SP232AEN-L/TR is a 2/2 RS-232 transceiver operating from a single 5 V-class supply. Mouser describes it as a 5 V single-supply RS-232 interface IC, and DigiKey identifies the part as a dual line-driver and receiver in a 16-pin SOIC. It is appropriate for UART-to-RS-232 conversion, not RS-485 multidrop networks.
What is the temperature range of SP232AEN-L/TR?
The SP232AEN-L/TR is specified for -40°C to +85°C. The Mouser product result identifies the MaxLinear SP232AEN-L/TR operating range as -40°C to +85°C, while the related SP232AEN listing describes the same industrial temperature span. The final operating limit should still be checked against the complete manufacturer datasheet and system enclosure temperature.
What can replace SP232AEN-L/TR?
The strongest verified drop-in replacement identified for the SP232AEN-L/TR is the SP232AEN-L, which uses the same SP232AEN 16-SOIC family and is directly compared as an alternative to SP232AEN-L/TR. Confirm speed, ESD, supply, pinout, and lifecycle requirements before substitution. Packaging suffixes alone should not be treated as replacements.
Is SP232AEN-L/TR compatible with RS-232 V.28 systems?
Yes. The MaxLinear datasheet says the SP232A is a line-driver and receiver pair that meets RS-232 and V.28 serial-protocol specifications. It therefore fits conventional UART-to-RS-232 equipment, including service consoles and controller interfaces. It does not convert the system to differential RS-422 or RS-485 signaling.
What is the SP232AEN-L/TR vs SP232AEN-L/TR distinction?
SP232AEN-L/TR is the orderable reel-packaged MPN specified in the distributor data, while SP232AEN-L is the related base-family listing identified by the cross-reference search. The available comparison results do not establish a functional difference, so engineers should verify the manufacturer ordering table before treating one as a substitute for the other.
How much does SP232AEN-L/TR cost?
The verified LCSC listing shows SP232AEN-L/TR priced from $0.3941, and the product result states that the part is in stock. This price is the available starting price rather than a guaranteed volume quote and is current as of 2026-10-23. Check stock, breaks, and landed cost at the distributor before purchasing.
Where can I buy SP232AEN-L/TR online?
SP232AEN-L/TR can be purchased from DigiKey, Mouser, LCSC, and other distributors listed in the verified search results. LCSC identifies the part as in stock and lists a starting price of $0.3941 as of 2026-10-23, while DigiKey describes it as available to buy. Request a quotation when production quantity, traceability, or delivery schedule matters.
What is the lead time for SP232AEN-L/TR?
The verified results do not provide a numeric production lead time for SP232AEN-L/TR. LCSC lists the component as in stock, but stock quantity and future replenishment timing are not stated. For procurement, request a dated quotation from the distributor and confirm the manufacturer’s lifecycle and allocation status before releasing a production order.
Is SP232AEN-L/TR in stock?
Yes, the verified LCSC result explicitly labels SP232AEN-L/TR as an in-stock component. That statement is a point-in-time distributor result rather than a guarantee of future inventory, and no quantity is provided. Verify availability, package details, and lead time at the distributor when placing an order.
What is the best drop-in replacement for SP232AEN-L/TR?
SP232AEN-L is the clearest verified family-level candidate because the cross-reference search directly compares SP232AEN-L with SP232AEN-L/TR and identifies the shared SP232AEN naming and package context. Confirm the exact 16-SOIC pinout, 120 kbps requirement, 4.5 V to 5.5 V supply, and 2 kV ESD expectation before approval. No additional cross-brand equivalent was sufficiently verified in the supplied data.
Can MAX232 replace SP232AEN-L/TR?
The supplied data does not verify a MAX232 MPN as a pin-to-pin, same-package replacement for SP232AEN-L/TR. The MAX232 family may be electrically related to RS-232 interface designs, but cross-brand alternatives require verified package, pinout, speed, supply, and protection data. Do not substitute MAX232 solely because both products are RS-232 transceivers.
What are the key specifications engineers should know about SP232AEN-L/TR?
The key verified specifications are 4.5 V to 5.5 V single-supply operation, 120 kbps data rate under load, 2/2 driver-receiver channels, -40°C to +85°C operation, 0.1 µF ceramic charge-pump capacitors, BiCMOS architecture, and a 16-lead SOIC package. The part also has a reported 2 kV ESD specification in related distributor data. Verify the complete ordering and electrical details in the MaxLinear datasheet.
What design considerations apply when using SP232AEN-L/TR?
Place the 0.1 µF ceramic charge-pump capacitors and supply bypass capacitor close to the device according to the MaxLinear datasheet. Keep RS-232 connector traces short, provide a continuous ground return, and account for ESD protection at the connector. The interface is intended for RS-232 point-to-point links and should not be mistaken for an RS-485 multidrop transceiver.

工程参考数据: SP232AEN-L/TR ——对比、设计指导和合规信息。

选型指南

Choose SP232AEN-L/TR when the design needs a dual RS-232 transceiver in a 16-SOIC package with a 4.5 V to 5.5 V single supply, operation from -40°C to +85°C, and up to 120 kbps under load. It is a strong fit for UART service ports, PLC maintenance interfaces, test instruments, and legacy modem links. SP232AEN-L is the closest verified family candidate when the exact ordering code must be checked, but the supplied data does not prove a quantified electrical difference. Do not choose an RS-485 replacement merely because it has a similar channel count; RS-232 is single-ended and point-to-point. Verify connector pinout, cable length, ESD requirements, charge-pump capacitor placement, lifecycle status, and distributor stock before releasing production quantities.

与替代料对比

参数 本产品 SP232AEN-L
Package 16-SOIC 16-SOIC
Brand MaxLinear MaxLinear
Device Type Dual RS-232 transceiver Dual RS-232 transceiver
Supply Voltage 4.5 V to 5.5 V 4.5 V to 5.5 V
Temperature Range -40°C to +85°C -40°C to +85°C
ESD 2 kV 2 kV
Architecture BiCMOS BiCMOS

关键差异点

  • Single-supply RS-232 interface with integrated charge-pump support (对比 SP232AEN-L)
  • Verified 120 kbps-under-load capability (对比 SP232AEN-L)
  • Industrial temperature capability (对比 SP232AEN-L)

设计说明

Use the manufacturer-specified 0.1 µF ceramic charge-pump capacitors for the SP232AEN and a local supply bypass capacitor close to VCC. Keep the charge-pump loop compact because long traces increase loop area and can reduce effectiveness of the internal charge pump. The verified 4.5 V to 5.5 V supply range should be checked against the actual rail tolerance and startup sequence.

Place the RS-232 connector-side driver and receiver pins away from noisy clocks, switching inductors, and high-current return paths. Route the interface as a pair with an uninterrupted ground return, and keep the external protection components close to the connector. The SP232AEN-L/TR is a single-ended RS-232 device, so ground integrity is part of signal integrity rather than an optional layout detail.

Do not substitute an RS-485 transceiver solely because it also uses a 2/2 driver-receiver arrangement. RS-232 and RS-485 use different voltage polarity, topology, termination, and multidrop behavior. Also verify the exact MPN suffix and package pinout before assembly, because the supplied cross-reference evidence confirms only the SP232AEN-L family relationship and does not establish a broad cross-brand replacement list.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

The supplied distributor and manufacturer results do not explicitly state RoHS, REACH, lead-free, halogen-free, or conflict-minerals status. AEC-Q100 is marked not applicable because this is an RS-232 interface IC rather than an automotive-qualified device in the provided data.

数据核验日期: 2026-10-23 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

SP232AEN-L/TR SP232AEN-L/TR datasheet PDF MaxLinear SP232AEN-L/TR 120 kbps dual RS-232 transceiver 16-SOIC single supply RS-232 IC SP232AEN-L/TR RS-232 interface SP232AEN-L/TR vs SP232AEN-L SP232AEN-L/TR replacement SP232AEN-L/TR price and stock RS-232 charge pump capacitor 0.1 uF SP232AEN-L/TR pinout single supply RS-232 UART industrial console

相关元器件 & 术语

MaxLinear SP232AEN-L/TR SP232AEN-L RS-232 V.28 UART line driver line receiver dual transceiver BiCMOS single-supply interface charge-pump capacitor 120 kbps 4.5 V to 5.5 V 16-SOIC industrial temperature range ESD protection UART-to-RS-232 PLC service port serial console test instrumentation point-of-sale peripheral legacy modem RS-485
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情