A clock divider is a timing semiconductor that creates a lower-frequency clock from a higher-frequency reference. Within the broader hierarchy of clock and timing integrated circuits, the SY89228UMG combines frequency division, differential clocking, fail-safe input behavior, and internal input termination. These functions support systems that require a stable divided clock while retaining the edge-rate and phase characteristics expected from LVPECL signaling.
The principal identified features include selectable divide-by-3 and divide-by-5 operation, LVPECL output signaling, fail-safe input support, and internal termination. The device operates from a 2.5 V supply, with a listed operating range of 2.375 V to 3.6 V. Its 16-VFQFN exposed-pad construction supports compact layouts while providing a dedicated thermal and electrical connection beneath the package.
The SY89228UMG uses one differential clock input and produces one LVPECL clock output. Its 1.5 GHz maximum clock frequency makes it relevant to telecommunications, data-communication, networking, and test-equipment clock trees where a high-speed reference must be divided before distribution. The fail-safe input characteristic is particularly useful when the source may become absent, invalid, or electrically uncertain. Internal termination simplifies input implementation by reducing the need for additional source-termination components.
Typical uses include parallel processing clock distribution, serializer and deserializer timing, network-interface clock division, and instrumentation requiring a divided low-noise differential clock. In a practical design, the input must be connected as a proper LVPECL interface, the supply and ground planes must be referenced correctly, and the exposed pad must be tied to the ground plane using the manufacturer’s recommended land pattern.
A key design consideration is that the SY89228UMG is a clock divider, not a clock generator or jitter-cleanup device. The input waveform, duty cycle, amplitude, and source impedance determine edge quality at the divider. Because the output is LVPECL, downstream receivers must use compatible termination and voltage-bias arrangements rather than single-ended CMOS inputs.
This page consolidates the manufacturer-related product information, package details, sourcing guidance, and design considerations into a compact engineering reference. It also distinguishes verified device facts from attributes that require confirmation from the full manufacturer datasheet before layout, simulation, or production release.
直接替换替代料: SY89228UMG ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
该产品暂无直接替换替代料。
请求替代料SY89228UMG 规格参数
| Device Type | LVPECL clock divider |
| Maximum Input Frequency | 1.5 GHz |
| Nominal Maximum Frequency | 1 GHz |
| Available Division Ratios | Divide-by-3 and divide-by-5 |
| Output Logic Type | LVPECL |
| Number of Clock Inputs | 1 |
| Number of Clock Outputs | 1 |
| Input Protection | Fail-safe input |
| Input Termination | Internal termination |
| Nominal Supply Voltage | 2.5 V |
| Operating Supply Voltage Range | 2.375 V to 3.6 V |
| 封装 | 16-VFQFN exposed pad |
| Package Type | 16-MLF QFN |
| 安装类型 | Surface mount |
| Packaging | Tube |
| Product Type | Clock divider, 1 input, 1 output |
SY89228UMG 16-mlf qfn 引脚配置指南
SY89228UMG(16-mlf qfn 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。
暂无详细引脚数据: SY89228UMG.
请参阅 数据手册 以查看完整引脚配置。
典型应用
SY89228UMG 适用于 6 应用s: Telecommunications Clock Distribution, Networking Equipment Clocking, Serializer and Deserializer Timing, Data Acquisition and Test Equipment, Industrial Control and Instrumentation, Fail-Safe Reference Distribution.
Telecommunications Clock Distribution
The SY89228UMG fits telecommunications clock trees that use a high-speed LVPECL reference and require a divided derivative for downstream circuits. Its divide-by-3 and divide-by-5 options support predictable frequency reduction without changing the differential clock family, while internal input termination can simplify the source interface. The listed maximum input frequency of 1.5 GHz places the device near the high-frequency end of its supported operating range. In a complete design, confirm the selected ratio’s maximum input frequency, output jitter contribution, and propagation delay against the manufacturer timing data. The 16-VFQFN exposed pad also requires a low-impedance ground plane and careful high-speed return-path implementation.
推荐
Networking Equipment Clocking
The SY89228UMG can divide a high-speed LVPECL clock in network-interface, switching, and line-card clocking subsystems. A divide-by-3 path can create one-third of the incoming frequency, while divide-by-5 supports systems requiring a one-fifth-rate clock for lower-speed logic or serial links. Its one-input, one-output arrangement keeps the clock topology predictable, and the internal termination helps control the high-speed input connection. The main engineering consideration is timing margin: use the manufacturer’s frequency-versus-ratio and supply-voltage limits to confirm operation at the intended input rate and temperature. The compact VFQFN package is advantageous where clock components must sit close to the receiving circuitry.
推荐
Serializer and Deserializer Timing
The SY89228UMG is applicable where serializer, deserializer, or data-conversion clocking requires a divided derivative of an existing LVPECL source. The selectable divide-by-3 and divide-by-5 ratios can reduce clock frequency while retaining a common differential signaling environment, which simplifies interfaces compared with converting to CMOS. Fail-safe input behavior is useful when upstream clock health must be controlled, and the internal termination reduces discrete input-network requirements. Designers should still validate output-to-output timing, deterministic jitter, duty-cycle distortion, and the receiver’s allowable LVPECL amplitude. Placement near the load is important because the clock divider introduces propagation delay in addition to the intentional frequency division.
推荐
Data Acquisition and Test Equipment
The SY89228UMG can serve in data-acquisition and test-equipment clock trees when a common high-speed reference must feed a slower timing domain. Dividing by 3 or 5 provides a simple way to establish related clock frequencies while retaining LVPECL signal integrity over controlled board traces. The fail-safe input characteristic is relevant in instrumentation where the source may be disconnected during calibration or fault injection. Internal input termination can shorten the high-frequency input network, although the complete source impedance must still be accounted for. For precision measurement systems, evaluate the divider’s added jitter and propagation delay against the acquisition timing budget, and keep the 16-VFQFN exposed pad thermally and electrically connected to a continuous ground plane.
推荐
Industrial Control and Instrumentation
The SY89228UMG can support industrial control and instrumentation subsystems that synchronize several functional blocks from an LVPECL reference. Its selectable divide-by-3 and divide-by-5 operation allows two related timing rates to be derived without changing the system’s differential clock standard. The 2.375 V to 3.6 V operating range accommodates a 2.5 V design, while internal termination assists with controlled high-speed routing. In an industrial environment, thermal and EMI performance remain design-dependent, so use solid ground and supply planes and follow the manufacturer’s exposed-pad layout. Before deployment, verify the input-frequency margin, fail-safe output state, and timing behavior across the complete operating voltage and temperature range.
推荐
Fail-Safe Reference Distribution
The SY89228UMG is appropriate for reference-distribution architectures where loss or invalidity of the source clock must be handled predictably. Its fail-safe input complements the divide-by-3 and divide-by-5 functions by helping maintain a defined operating state when the incoming reference is absent or unreliable. The internal termination can also make the LVPECL source interface more compact. System designers should still evaluate downstream behavior because fail-safe input does not replace health monitoring, isolation, or a designed clock-recovery architecture. Keep the divider close to the destination to minimize trace propagation delay, use controlled-impedance routing, and connect the exposed pad to ground according to the manufacturer’s land-pattern requirements. Review the exact fail-safe timing table before using the output as a system health signal.
推荐
推荐产品汇总
工程参考数据: SY89228UMG ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 |
|---|---|
| Brand | Microchip Technology |
| Package | 16-VFQFN exposed pad |
| Device Type | Clock divider |
| Maximum Input Frequency | 1.5 GHz |
| Division Ratios | Divide-by-3 and divide-by-5 |
| Output Logic | LVPECL |
| Number of Inputs | 1 |
| Number of Outputs | 1 |
| Supply Voltage | 2.375 V to 3.6 V |
| Special Features | Fail-safe input and internal termination |
关键差异点
- Selectable division in one clock-divider device (对比 SY89230UMG-TR)
- Integrated fail-safe input behavior (对比 SY89230UMG-TR)
- Internal source termination simplifies the clock input (对比 SY89230UMG-TR)
设计说明
Treat the SY89228UMG as a high-speed LVPECL device and route its clock input and output as short, controlled-impedance connections. Place the device near the source and load to minimize propagation-delay variation. Connect the exposed pad to a continuous ground plane using the manufacturer’s recommended via pattern, and avoid placing switching-converter paths or unrelated high-current traces beneath the clock circuitry.
Account for the internal input termination when calculating the complete LVPECL source impedance and voltage-divider network. Confirm the input amplitude, common-mode voltage, duty cycle, and edge rate against the manufacturer’s input conditions before dividing a particular source. Because a clock divider adds propagation delay and can alter timing performance, characterize the divided output in the assembled board rather than relying only on nominal source frequency.
Use a stable 2.5 V supply within the stated 2.375 V to 3.6 V operating range, and place local high-frequency decoupling close to the supply and ground terminals. Keep the decoupling return path within the same ground-reference region as the LVPECL interface. Verify supply-noise tolerance and output jitter in the final configuration, particularly when the clock divider is downstream of a switching regulator.
Do not treat the SY89228UMG as a standalone oscillator, and do not connect its LVPECL output directly to an unverified CMOS receiver. A different divide ratio, missing fail-safe behavior, or an incompatible input termination may prevent a superficially similar clock-divider part from serving as a true drop-in replacement. Confirm divide-mode control, pin functions, frequency limits, and output loading from the manufacturer datasheet before releasing the PCB.
合规信息
The available product information does not explicitly state RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status. Confirm these attributes using the current manufacturer material declarations before regulatory submission.