TCAN337DCNR - 3.3V 1Mbps CAN Transceiver | Texas Instruments
料号: TCAN337DCNR ✓ 量产中TCAN337DCNR 概述
A CAN transceiver is an interface IC that connects a host controller's digital logic to a Controller Area Network physical layer. The transmitter converts logic-level signals into a dominant or recessive bus state, while the receiver converts bus states back into logic-level signals. Together, these functions form part of the broader CAN interface hierarchy: CAN controller, CAN transceiver, CAN bus, and connected electronic control units.
The TCAN337DCNR operates from a 3.3 V supply and supports CAN data rates up to 1 Mbps. Its one-driver, one-receiver arrangement supports half-duplex CAN communication, while the SOT-23-8 package minimizes board area. The family also includes ultra-low-power shutdown and standby modes, making it suitable for battery-powered equipment that periodically enters a reduced-power state. The specified operating-temperature range extends from -40 °C to 125 °C.
The TCAN337 family is associated with the ISO 11898 High-Speed CAN physical-layer standard. Its low-voltage supply operation and small footprint make it suitable for CAN nodes built around 3.3 V microcontrollers, where larger SOIC packages would consume unnecessary board space. A designer should still validate the complete bus network, including cable length, termination, node count, transceiver timing, and controller compatibility.
Typical uses include industrial automation equipment, automotive body and comfort modules, battery-powered sensors, building-control gateways, and compact CAN-to-serial or CAN-to-Ethernet gateways. The device is particularly useful where a controller operates from 3.3 V and board area is more constrained than thermal dissipation.
For a new design, follow the manufacturer's recommended bus and decoupling connections, place the device close to the CAN connector and protection network, and verify the transceiver's mode-control logic against the system power sequence. The TCAN337DCNR is identified as active by Texas Instruments.
This page organizes the confirmed electrical, package, application, and lifecycle information into an engineering-focused selection guide. It also distinguishes directly comparable same-family devices from options that would require changes to the PCB footprint or CAN network configuration.
直接替换替代料: TCAN337DCNR ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: TCAN337DCNR (相同外形与封装尺寸) ——差异在于 Operating Temperature Range, Product Type, Package, Maximum CAN Data Rate, Pin Count.
TCAN330DCNR
✅ 直接替换联系询价
查看数据手册 →TCAN332DCNR
✅ 直接替换 ⚠️ 规格未核验联系询价
查看数据手册 →TCAN334DCNT
✅ 直接替换 ⚠️ 规格未核验联系询价
查看数据手册 →TCAN337DCNR 规格参数
| Product Type | CANbus transceiver |
| 电源电压 | 3.3 V |
| Operating Supply Voltage Range | 3 V to 3.6 V |
| Maximum CAN Data Rate | 1 Mbps |
| Number of Drivers | 1 |
| Number of Receivers | 1 |
| Duplex Type | Half-duplex |
| Receiver Hysteresis | 120 mV |
| CAN Protocol | CANbus |
| Physical-Layer Standard | ISO 11898 High-Speed CAN |
| 工作温度范围 | -40 °C to 125 °C |
| 封装 | SOT-23-8 (DCN) |
| 引脚数 | 8 pins |
| 安装类型 | Surface mount |
| Power States | Shutdown and standby modes |
| Product Status | Active |
TCAN337DCNR sot-23-8 (dcn) 引脚配置指南
TCAN337DCNR(sot-23-8 (dcn) 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。
暂无详细引脚数据: TCAN337DCNR.
请参阅 数据手册 以查看完整引脚配置。
典型应用
TCAN337DCNR 适用于 6 应用s: 3.3V Industrial CAN Sensor Node, Automotive Body Control Module, Battery-Powered CAN Gateway, Building Control and HVAC Interface, CAN-to-Ethernet Communication Module, Compact CAN-to-Serial Adapter.
3.3V Industrial CAN Sensor Node
The TCAN337DCNR fits compact industrial sensor nodes that communicate over a 3.3 V CANbus. Its 3 V to 3.6 V operating range aligns with common 3.3 V embedded controllers, while the one-driver, one-receiver transceiver provides the required physical-layer interface at rates up to 1 Mbps. The 8-pin SOT-23-8 package conserves board area in distributed instrumentation. Place the transceiver near the connector and its protection components, and validate timing for the longest cable and highest node count in the network.
推荐
Automotive Body Control Module
The TCAN337DCNR is suitable for low-voltage CAN links in compact automotive body, comfort, and sensor-control modules. Its specified -40 °C to 125 °C operating range covers harsh-temperature environments, and the 3.3 V supply supports integration with 3.3 V logic. The SOT-23-8 footprint allows placement near board connectors while leaving more PCB area for protection and routing. Automotive qualification status must be confirmed for the exact ordered device before production release.
推荐
Battery-Powered CAN Gateway
The TCAN337DCNR works well in a battery-powered gateway where the CAN interface must coexist with a low-voltage embedded controller. Its 3.3 V operating range and TCAN337-family shutdown and standby modes support power-conscious system designs, while the 1 Mbps capability handles normal CANbus traffic. The small SOT-23-8 package is valuable in portable equipment. Define mode-control defaults so the bus transmitter is disabled during low-power states, and use the manufacturer's test conditions when calculating standby current.
推荐
Building Control and HVAC Interface
The TCAN337DCNR can serve as the CAN physical-layer device in compact building-control, HVAC, or facilities-management equipment. Its 1 Mbps data rate is appropriate for conventional CAN networks, and the 120 mV receiver hysteresis supports dependable interpretation of bus levels. The SOT-23-8 package helps reduce controller-board size. For industrial deployment, check the complete operating-temperature requirement, select termination and protection for the cable environment, and verify controller timing at the longest planned bus length.
推荐
CAN-to-Ethernet Communication Module
The TCAN337DCNR is appropriate for a CAN-to-Ethernet bridge that converts messages between a CAN network and a higher-level communications processor. The transceiver handles the physical CAN layer while the bridge controller manages protocol conversion and data routing. Its 3.3 V operation, 1 Mbps rate, and small SOT-23-8 footprint support compact embedded networking equipment. Place the transceiver near the CAN connector, provide the specified bus protection, and keep Ethernet and CAN return-current paths arranged to minimize coupling.
推荐
Compact CAN-to-Serial Adapter
The TCAN337DCNR is a practical choice for a compact CAN-to-serial adapter connecting legacy serial equipment to a modern CAN network. Its one-driver, one-receiver arrangement and 1 Mbps capability support ordinary CANbus communication, while the 8-pin SOT-23-8 package minimizes the adapter footprint. The 3.3 V supply requirement must match the adapter's logic rail. Use level-compatible serial components, provide accessible bus termination, and confirm that the selected controller supports the bus timing and identifiers used by the network.
推荐
推荐产品汇总
工程参考数据: TCAN337DCNR ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | TCAN330DCNR | TCAN332DCNR | TCAN334DCNT |
|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | SOT-23-8 (DCN) | SOT-23-8 (DCN) | SOT-23-8 (DCN) | SOT-23-8 (DCN) |
| Product Type | 3.3 V CANbus transceiver | CANbus transceiver | CANbus transceiver | CANbus transceiver |
| Maximum Data Rate | 1 Mbps | 1 Mbps | 1 Mbps | 1 Mbps |
| Number of Drivers/Receivers | 1/1 | 1/1 | 1/1 | 1/1 |
| Physical-Layer Standard | ISO 11898 High-Speed CAN | ISO 11898 High-Speed CAN | ISO 11898 High-Speed CAN | ISO 11898 High-Speed CAN |
关键差异点
- Compact 3.3 V CAN interface in an 8-pin SOT-23 package (对比 TCAN330DCNR)
- Wide specified operating-temperature range (对比 TCAN334DCNT)
- 3.3 V supply operation with 1 Mbps performance (对比 TCAN332DCNR)
设计说明
Place the TCAN337DCNR close to the CAN connector, termination network, and transient-voltage protection components. Keep the CANH and CANL route symmetrical where practical and avoid long unprotected traces. Route the transceiver ground return directly to the ground plane, and maintain a continuous return path beneath the bus pair. This placement reduces radiated emissions and susceptibility to differences between the transceiver and connector ground currents.
Tie the transceiver supply pins to a clean 3.3 V rail and place the manufacturer-recommended bypass capacitor immediately beside the device. Do not route bus return current through the logic supply ground path. In standby or shutdown designs, define mode-control defaults so the transmitter cannot unintentionally dominate the bus during startup, reset, or low-battery operation.
Separate CAN routing from clocks, high-speed serial links, switching-node power stages, and other likely noise sources. Avoid placing test pads or long stubs on CANH or CANL unless their effects have been evaluated. Keep the termination capacitor close to the connector rather than at the transceiver, and follow the bus topology and termination scheme specified for the number of active nodes.
A matching SOT-23-8 footprint does not by itself prove that another TCAN33x device is a functional replacement. Check mode-control polarity, shutdown and standby behavior, bus-fault response, propagation timing, supply limits, and controller compatibility. When substituting a part, review its manufacturer application circuit and update firmware or board-control logic wherever the operating modes differ.
合规信息
The manufacturer identifies TCAN337DCNR as active. Exact RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals status must be confirmed for the ordered device.