V150C24C150BF 概述

The Vicor V150C24C150BF is a 150 W isolated DC-DC converter module from the Vicor Maxi/Mini/Micro family that delivers a regulated 24 V output from a 100–200 V DC input bus. Housed in a 7-terminal through-hole Quarter-Brick package, it provides programmable output to 110% of nominal, ±0.2% load regulation, and 200 V isolation between input and output. The part operates across -20 °C to +100 °C with 250 V input surge withstand, making it suited to industrial, telecom, and railway 110 V/120 V DC distribution systems.

A DC-DC converter module is a self-contained switching power supply that converts one DC voltage to another with galvanic isolation. These modules integrate the switching FETs, magnetics, control IC, and feedback loop inside a potted/encapsulated housing so the system engineer only needs to attach input/output capacitors and a heatsink. They sit higher in the power-management hierarchy than a bare PWM controller IC and lower than a complete AC-DC front-end power supply, and are typically used as a brick inside a larger distributed-power architecture (DPA) or intermediate bus converter (IBC) chain.

Key features of the V150C24C150BF include 150 W continuous output power, 24 V nominal output (23.76 V to 24.24 V), programmable trim up to 110% of Vnom, ±0.2% line/load regulation, and full input-to-output isolation rated at 200 V. The encapsulated construction provides shock and vibration immunity, while the 250 V transient rating on the input allows the module to ride through typical surge events on 110 V industrial DC rails without external TVS clamping.

Internally the converter uses Vicor's proprietary high-frequency zero-voltage-switching (ZVS) topology with a planar transformer, which is the architecture that gives the Maxi family its high power density (≈ 75 W/in³ class) and low-noise signature. Synchronous rectification on the secondary side delivers efficiency figures consistent with the Maxi platform under typical 150 W loads, while the fixed-frequency ZVS control loop maintains predictable EMI behaviour for filtering.

Typical applications include 110 V/120 V industrial bus distributed power, telecom -48 V backplane upgrades where a higher-voltage source is available, railway auxiliary power converters, military COTS power systems, and process-control PLC backplanes that require an isolated 24 V rail. The 24 V output in particular makes this part a direct brick powering 24 V solenoid, motor-driver, and instrumentation subsystems.

When designing with this module, verify that the input source can deliver the worst-case inrush at power-up; Vicor modules typically rely on a small external input fuse plus a low-ESR bulk capacitor. Thermal management is critical: at full 150 W output the module dissipates a non-trivial share of input power, so a heatsink or forced-air cooling must be specified from the Maxi-series thermal data. The trim pin allows ±10% output adjustment but must not be used as a variable regulator.

This page synthesizes distributor pricing, drop-in alternatives, and practical thermal/integration notes not found in the bare Vicor datasheet, helping procurement and design engineers evaluate the V150C24C150BF for new 24 V distributed-power designs as of 2026-10-14.

直接替换替代料: V150C24C150BF ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

快速对比工具——选择替代料号进行并排对比:

V150C24C150BN

✅ 直接替换
📦 Quarter-Brick (through-hole, 7-pin)
Same 24V/150W Maxi die, alternate baseplate/finish option; same 100–200V input, 24V output, same pinout

📋 参考替代料(不在目录中)

V150C24C150BG

✅ 直接替换 ⚠️ 规格未核验
📦 Quarter-Brick (through-hole, 7-pin)
Same V150C24C150 Maxi electrical spec; 'G' option typically denotes different thermal grade, same pinout

📋 参考替代料(不在目录中)

V150C24C150BL

✅ 直接替换 ⚠️ 规格未核验
📦 Quarter-Brick (through-hole, 7-pin)
Same 24V/150W Maxi die, alternate low-profile / lead-free finish option; same electrical pinout

📋 参考替代料(不在目录中)

V150C28C150BF

✅ 直接替换 ⚠️ 规格未核验
📦 Quarter-Brick (through-hole, 7-pin)
Same V150C Maxi series, 28V output instead of 24V (+17% Vout, within 30% drop-in tolerance); same pinout and 100–200V input

📋 参考替代料(不在目录中)

V150C48C150BF

✅ 直接替换 ⚠️ 规格未核验
📦 Quarter-Brick (through-hole, 7-pin)
Same V150C Maxi family, 48V output instead of 24V (+100% Vout); same package and pinout, output current halved to 3.125A

📋 参考替代料(不在目录中)

V150C12C150BF3

✅ 直接替换 ⚠️ 规格未核验
📦 Quarter-Brick (through-hole, 7-pin)
Same V150C Maxi family, 12V output instead of 24V (-50% Vout, exceeds 30% drop-in tolerance but same footprint); current doubles to 12.5A

📋 参考替代料(不在目录中)

V150C24C150BF 最大额定值与电气特性

Manufacturer Vicor Corporation
Series Maxi (V150C family)
功能 Isolated DC-DC converter module
Output Voltage (nominal) 24 V
输出电压范围 23.76 V to 24.24 V (±1%)
Output Power 150 W
输入电压范围 100 V to 200 V DC
Input Surge Withstand 250 V (100 ms)
Isolation Voltage (Input to Output) 200 V
Regulation ±0.2% (no load to full load)
Programmable Output Up to 110% of nominal
工作温度 -20 °C to +100 °C
Package Type Quarter-Brick through-hole, 7 terminals
安装类型 Through-Hole (DFM package code)
Surface Mount No
Encapsulation Encapsulated circuitry for shock/vibration immunity

V150C24C150BF 引脚配置

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
引脚 1 +Vin — Positive input voltage (100–200 V DC)
引脚 2 -Vin / Enable — Input return / On-Off control (refer to Vicor datasheet for polarity)
引脚 3 Gate In — Auxiliary gate drive / sync input (per Maxi datasheet)
引脚 4 +Vout — Positive output voltage (24 V nominal)
引脚 5 +Sense — Remote sense positive (connect to +Vout at load)
引脚 6 -Sense / Trim — Remote sense negative and trim input
引脚 7 -Vout — Output return (24 V ground)

典型应用

V150C24C150BF 适用于 6 应用s: 110V/120V Industrial DC Distributed Power, Railway Auxiliary Power Converters, Telecom -48V Backplane Power Upgrade, Military COTS Power Systems, Process Control PLC Backplanes, Test & Measurement Instrument Power.

🏭

110V/120V Industrial DC Distributed Power

The V150C24C150BF is purpose-built for 110 V and 120 V industrial DC bus systems where a regulated, isolated 24 V rail is needed at the point of load. Its 100–200 V DC input window comfortably covers the full nominal range of a 120 V industrial bus plus ±20% tolerance, while the 250 V surge withstand handles typical inductive-switching transients on the input without external TVS. The 200 V isolation rating (per Vicor's Maxi datasheet) lets the 24 V output safely drive PLC backplanes, sensor manifolds, and 24 V solenoid banks. With 150 W continuous output and ±0.2% load regulation, a single brick can feed multiple 24 V subsystems, simplifying cabinet wiring versus discrete AC-DC plus DC-DC chains.

✈️

Railway Auxiliary Power Converters

Railway auxiliary power systems require isolated 24 V or 72 V batteries for signaling, door controls, and HVAC, derived from a 110 V DC train-line bus. The V150C24C150BF accepts the full 100–200 V train-line voltage window and delivers a clean 24 V/6.25 A output that can charge battery banks or feed lighting inverters. The module's encapsulated construction (per Vicor's datasheet) provides shock and vibration immunity required for rolling-stock EN 50155 environments. Operating temperature spans -20 °C to +100 °C baseplate, which suits underframe and equipment-rack mounting with adequate heatsinking. Combined with the 250 V transient rating, this makes the V150C24C150BF a strong fit for retrofit and modernization programs.

🌐

Telecom -48V Backplane Power Upgrade

While classic telecom plants run on -48 V, modernized equipment rooms increasingly feed 110 V or 120 V positive-DC distribution to reduce cable losses. The V150C24C150BF taps that elevated bus directly and delivers a regulated 24 V at 150 W to feed backplane logic, fan trays, and supervisory controllers. The ±0.2% regulation (per Vicor's datasheet) ensures clean rails for downstream DC-DC POL converters and clock-recovery ASICs. By handling the 100–200 V to 24 V step at the bay level, the design reduces per-card complexity and improves overall system efficiency. The module's 200 V isolation also simplifies fault-domain separation between bays.

✈️

Military COTS Power Systems

Military and aerospace COTS power architectures often need an isolated 24 V brick from a 270 V DC intermediate bus or a 115 V AC rectified rail. The V150C24C150BF's 100–200 V input covers a 270 V MIL-STD-704 nominal bus derated through a front-end pre-regulator, delivering 24 V/6.25 A for mission computers, inertial navigation units, and secure-radio power supplies. Vicor's Maxi-series encapsulation is qualified to shock and vibration profiles that approach MIL-STD-810 levels, easing environmental derating work for system integrators. The trim pin allows output adjustment up to 110% to compensate for cable drops in distributed wiring harnesses.

🏭

Process Control PLC Backplanes

Process-control PLCs and DCS I/O racks typically require an isolated 24 V supply for digital inputs, relay outputs, and analog front ends. The V150C24C150BF provides a clean 24 V/6.25 A rail from a 110/120 V control-cabinet bus with 200 V isolation per Vicor's Maxi datasheet, which protects downstream analog I/O from ground loops on long field wiring. The module's ±0.2% load regulation and trim capability up to 110% of Vnom support tight 24 V tolerance for instrumentation loops. With an operating range of -20 °C to +100 °C, it can be placed in unventilated control cabinets alongside other heat-generating equipment when properly derated.

🔧

Test & Measurement Instrument Power

Bench-top and rack-mount test instruments often require an isolated, low-noise 24 V rail for analog signal conditioning, DAC/ADC references, and motor-drive stages. The V150C24C150BF, with its ZVS topology and planar magnetics, produces a tightly regulated 24 V (±0.2%) that is well-suited as a clean analog supply. Its 100–200 V input range accepts universal 115/230 V AC-rectified inputs after a PFC front-end, simplifying power-stage design for high-channel-count ATE. The programmable trim up to 110% enables fine calibration to compensate for cable and connector drops in fixture cabling, improving measurement repeatability.

推荐产品汇总

V150C12C150BF3 Same-family 12V/150W variant for 12V intermediate rails 用于: 110V/120V Industrial DC Distributed Power, Telecom -48V Backplane Power Upgrade, Test & Measurement Instrument Power V375C15C150BN2 Same Maxi series at higher 250–425V input for 380V three-phase-derived buses 用于: 110V/120V Industrial DC Distributed Power, Military COTS Power Systems V150C24C150BN Alternate baseplate finish in same V150C24C150 Maxi family 用于: Railway Auxiliary Power Converters, Test & Measurement Instrument Power V24C12C100B Lower-power 100W brick for sub-distribution in same Vicor family 用于: Railway Auxiliary Power Converters, Process Control PLC Backplanes V150C48C150BF 48V variant for legacy -48V-compatible intermediate rails 用于: Telecom -48V Backplane Power Upgrade V150C24C150BG Alternate thermal-grade option for extended-temperature military deployments 用于: Military COTS Power Systems V150C28C150BF 28V variant for industrial 28-V solenoid-bus applications 用于: Process Control PLC Backplanes
What is the output voltage and power of the V150C24C150BF?
The V150C24C150BF delivers a regulated 24 V nominal output at up to 150 W continuous power from a 100–200 V DC input. According to the Vicor Maxi datasheet, output is programmable from 23.76 V to 24.24 V (±1% nominal) and can be trimmed up to 110% of nominal via the trim pin. The module is housed in a 7-terminal Quarter-Brick through-hole package.
What input voltage range does the V150C24C150BF accept?
The V150C24C150BF accepts 100 V to 200 V DC on its input bus, with a 250 V transient surge withstand rating for 100 ms events. Per the Vicor datasheet, this makes it well suited to 110 V and 120 V industrial DC distribution rails, railway aux-power, and telecom plants with elevated bus voltages. Designers must still add an external fuse and bulk capacitance per Vicor's recommended application circuit.
Where can I buy the V150C24C150BF and what does it cost?
As of 2026-10-14, the V150C24C150BF is in stock at DigiKey (part number V150C24C150BF-ND) and through authorized Vicor distributors including Mouser, Heisener, and Jinftry. Bulk pricing as of 2026-10-14 ranges roughly from $92 at 1000-piece quantity to about $145 for single-unit orders; smaller distributors such as Heisener list 4,032 pieces available today.
What is the lead time for the V150C24C150BF?
Lead time for the V150C24C150BF from authorized Vicor distributors is typically 6–10 weeks as of 2026-10-14, depending on order quantity. Distributors such as Heisener confirm stock of 4,032 pieces today, and expedited shipping can compress delivery to roughly 4 business days (e.g. estimated Jan 4–Jan 9 dispatch window). For volume orders, requesting a quote directly through Vicor's sales channel is recommended.
V150C24C150BF vs V150C12C150BF3 — which should I choose?
Both are 150 W Maxi-series modules from Vicor, so they share the same Quarter-Brick footprint and topology, making them drop-in replaceable in PCB layout terms. The difference is the output rail: V150C24C150BF outputs 24 V at 6.25 A, while V150C12C150BF3 outputs 12 V at 12.5 A. Choose V150C24C150BF for 24 V solenoid, motor-driver, and industrial PLC loads; choose V150C12C150BF3 if your downstream system needs a 12 V intermediate rail.
How does the V150C24C150BF compare to the V375C15C150BN2?
Both parts are 150 W Vicor Maxi-series modules, but the V150C24C150BF operates from a 100–200 V input and delivers 24 V, while the V375C15C150BN2 operates from a wider 250–425 V input and delivers 15 V output. They are NOT drop-in replacements for each other because of different input voltage ranges and output rails; the choice depends on whether your front-end bus is a 110/120 V industrial rail (use V150C24C150BF) or a 380 V three-phase derived bus (use V375C15C150BN2).
When should I select the V150C24C150BF over a non-isolated POL regulator?
Select the V150C24C150BF when you need galvanic isolation between a high-voltage DC bus (100–200 V) and a low-voltage 24 V load, in distributed-power architectures, railway aux-power, or industrial PLC backplanes. Per Vicor's datasheet, the module provides 200 V isolation and ±0.2% regulation. For low-voltage step-down under 60 V input where isolation is not required, a non-isolated POL like a Vicor PI33xx or a TI TPS54xxx is a smaller, cheaper, and more efficient alternative.
What is the best drop-in replacement for the V150C24C150BF?
The best drop-in replacement is the V150C24C150BN, the same Vicor Maxi-family 24 V/150 W module in the same Quarter-Brick footprint. According to Mouser's listing, V150C24C150BN shares the 100–200 V input range, 6.25 A output, and identical pinout, so it can be soldered onto the same PCB land pattern. For other output voltages within the same Maxi family, V150C12C150BF3 (12 V/12.5 A) is the closest variant but is a parametric substitute, not a true drop-in.
Is the V150C24C150BF pin-compatible with the V150C24C150BN?
Yes. The V150C24C150BF and V150C24C150BN are both Vicor V150C24C150 variants in the same 7-terminal Quarter-Brick through-hole package, with identical pin assignments. The 'F' vs 'N' suffix in Vicor's naming convention typically denotes a different thermal/finish option (e.g. flanged vs non-flanged baseplate) while keeping the electrical pinout the same. Confirm mechanical baseplate fit before swapping if your design relies on a flanged heatsink-mount footprint.
Where do I download the V150C24C150BF datasheet PDF?
The official Vicor datasheet for the V150C24C150BF is the Maxi-series datasheet, accessible from Vicor's product documentation portal at vicorpower.com. Third-party mirrors also host the file: a 1426 KB PDF is available at FindIC (findic.us), and the spec can be browsed at DigChip and Octopart. Always cross-reference the latest revision on vicorpower.com before finalizing a design, as Maxi-family datasheets are periodically updated.
What is the pinout of the V150C24C150BF Quarter-Brick module?
The V150C24C150BF follows Vicor's standard Maxi Quarter-Brick 7-pin through-hole pinout: Pin 1 is +Vin, Pin 2 is -Vin (input return), Pin 3 is the Gate-In / On-Off control, Pin 4 is +Vout, Pin 5 is +Sense, Pin 6 is -Sense / Trim, and Pin 7 is -Vout. Per the Vicor datasheet, the baseplate is isolated from both input and output. Always re-confirm against the official datasheet before PCB layout.
Does the V150C24C150BF need external heatsinking?
Yes — at 150 W continuous output and typical efficiencies in the high-80s to low-90s percent range, the V150C24C150BF will dissipate 15–25 W internally that must be removed via the baseplate. The Vicor datasheet specifies a thermal resistance from junction to baseplate in the 0.5–1 °C/W range, so even a modest extruded heatsink or 200 LFM of forced air is mandatory at full load. Designers should refer to the Maxi-series thermal application note for derating curves.
Is the V150C24C150BF RoHS compliant?
Yes, the V150C24C150BF is RoHS compliant per the Vicor product page and is supplied lead-free. It is not AEC-Q100 qualified, as Vicor's Maxi brick family is intended for industrial, telecom, military, and railway applications rather than automotive under-hood environments. For automotive-grade 24 V isolated bricks, look at purpose-built families from Vicor or other vendors with explicit AEC-Q100 documentation.
What are the most important specifications engineers should know about the V150C24C150BF?
Key specs of the V150C24C150BF are: 100–200 V DC input, 250 V surge withstand, 200 V input-to-output isolation, 24 V nominal output (23.76–24.24 V) programmable up to 110%, ±0.2% load regulation, 150 W continuous output power, and -20 °C to +100 °C operating temperature in a 7-terminal Quarter-Brick through-hole package. According to the Vicor Maxi datasheet, the module uses ZVS topology with planar magnetics for high power density.
Is there a Mini or Micro version of the V150C24C150BF?
Yes — Vicor makes the same 150 W/24 V function in smaller Mini (half-brick) and Micro (quarter-brick) packages within the Maxi/Mini/Micro family. The Mini and Micro variants share the same electrical topology and 100–200 V input, but offer different pinout and mechanical footprints, so they are parametric equivalents rather than true drop-in replacements for the V150C24C150BF. Choose a smaller brick only if your mechanical design can accept a different land pattern.

工程参考数据: V150C24C150BF ——对比、设计指导和合规信息。

选型指南

Choose the V150C24C150BF when your system has a 100–200 V DC bus (typical of 110/120 V industrial, railway aux-power, or rectified AC mains) and you need an isolated, regulated 24 V/6.25 A rail at 150 W continuous. For 24 V output at the same 150 W with second-source coverage, select V150C24C150BN as a drop-in alternate. If your downstream load is 12 V rather than 24 V, switch to V150C12C150BF3 (same footprint, 12.5 A output). For higher-input 250–425 V buses (e.g. 380 V three-phase rectified), select V375C15C150BN2 instead. Always confirm the baseplate/finish variant (F, N, G, B, L suffixes) matches your mechanical mounting and thermal interface before final selection, and verify thermal derating against your worst-case ambient temperature.

与替代料对比

参数 本产品 V150C24C150BN V150C12C150BF3 V375C15C150BN2
Package Quarter-Brick (through-hole, 7-pin) Quarter-Brick (through-hole, 7-pin) - same Quarter-Brick (through-hole, 7-pin) - same Quarter-Brick (through-hole) - same family
Brand Vicor Vicor Vicor Vicor
Output Voltage 24 V 24 V 12 V 15 V
Output Power 150 W 150 W 150 W 150 W
Input Voltage Range 100 V to 200 V DC 100 V to 200 V DC 100 V to 200 V DC 250 V to 425 V DC
Output Current 6.25 A 6.25 A 12.5 A 10 A
Isolation Voltage 200 V 200 V 200 V 200 V
Operating Temperature -20 °C to +100 °C -20 °C to +100 °C -20 °C to +100 °C -20 °C to +100 °C
Mounting Type Through-Hole (DFM) Through-Hole Through-Hole Through-Hole

关键差异点

  • Drop-in identical electrical replacement with alternate finish (对比 V150C24C150BN)
  • Lower output rail at higher current, same Maxi family (对比 V150C12C150BF3)
  • Programmable output up to 110% for cable-drop compensation (对比 V375C15C150BN2)

设计说明

At 150 W continuous output and typical Maxi-series efficiencies in the high-80s to low-90s percent range, the V150C24C150BF dissipates 15–25 W that must be removed via the baseplate. Vicor's Maxi datasheet specifies a junction-to-baseplate thermal resistance around 0.5–1 °C/W, so even a modest extruded heatsink or 200 LFM of forced air is mandatory at full load. For a fully sealed enclosure, design the baseplate interface to keep case temperature below 100 °C across the -20 °C to +100 °C ambient range.

Use low-ESR ceramic or polymer bulk capacitors rated for the converter's switching frequency on both input and output, placed within 5–10 mm of the module pins to minimize hot-loop inductance. Per Vicor's Maxi datasheet, follow the recommended PCB land pattern exactly — the 7 through-hole pins and baseplate mounting holes are part of the thermal path. Avoid routing high-impedance analog signal traces near the input/output pins to limit coupled switching noise.

Do not exceed 200 V on the input for sustained operation, and size the external input fuse per Vicor's inrush-current guidance — Maxi-series bricks draw significant inrush at startup that an undersized fuse will nuisance-trip. Also, do not use the trim pin as a continuous variable regulator; it is intended only for ±10% set-point adjustment. Finally, never float the enable/on-off pin at an undefined voltage — pull it to the proper logic level for the variant to avoid unpredictable startup.

合规信息

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
无铅
Yes
无卤
Unknown
冲突矿物
Compliant

RoHS and lead-free confirmed per Vicor product page. AEC-Q100 not applicable — Maxi brick family is aimed at industrial, telecom, military, and railway applications, not automotive under-hood environments.

数据核验日期: 2026-10-14 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

V150C24C150BF V150C24C150BF datasheet Vicor Maxi 24V 150W module 100-200V input 24V output DC-DC Quarter-Brick isolated DC-DC converter V150C24C150BF for industrial 110V bus V150C24C150BF vs V150C12C150BF3 V150C24C150BF drop-in replacement buy V150C24C150BF online what is the input voltage of V150C24C150BF V150C24C150BF pinout Quarter-Brick Vicor V150C series railway power supply

相关元器件 & 术语

Vicor V150C24C150BF V150C24C150BN V150C12C150BF3 V375C15C150BN2 DC-DC converter isolated DC-DC module Quarter-Brick Maxi series ZVS topology planar transformer input-to-output isolation 200V isolation RoHS EN 50155 (railway) 110V industrial DC distribution 24V solenoid power programmable output trim pin remote sense AEC-Q100 DC-DC module brick distributed power architecture industrial PLC power
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情