Vicor

V375A28H600BG - 28V 600W Maxi Isolated DC-DC | Vicor

料号: V375A28H600BG ✓ 量产中
有现货 1-3 个工作日内发货
28 V nominal (programmable 2.8 V to 30.8 V) Vdss 29.9 A (peak); 21.4 A steady per datasheet snippet Id Full Brick, Through-Hole Package
低至 $287.45 USD / 件
最小起订量: 1 |
价格更新于: 2026-10-13
批量定价
数量 单价 小计
1 $387.5 $387.50
10 $358.2 $3,582.00
100 $332.1 $33,210.00
500 $309.8 $154,900.00
1,000 $287.45 $287,450.00
ℹ️ 所有价格均以 USD 计价

V375A28H600BG 概述

The Vicor V375A28H600BG is a Maxi-series isolated DC-DC converter module delivering 28 V at up to 600 W (29.9 A full load, 21.4 A steady) from a 250 V to 425 V DC input range, housed in a through-hole Full Brick package. It is part of Vicor's broad modular power building-block family used in 24 V industrial bus, telecom, and high-end test equipment power architectures where isolation, high efficiency, and predictable EMI behavior are required.

An isolated DC-DC converter is a power-conversion module that uses a high-frequency switching transformer to provide galvanic isolation between input and output, stepping a wide-range DC bus to a regulated, low-noise DC rail. They sit above discrete buck regulators and below multi-kW front-end supplies in the power-tree hierarchy, combining isolation, inrush protection, filtering, and feedback compensation inside a single agency-qualified brick. The Maxi family is the mid-power tier of Vicor's brick platform (above Mini and below Mega), targeting the 200 W to 800 W range with peak efficiencies above 86%.

Key electrical specifications include a 28 V nominal output (programmable from 2.8 V to 30.8 V per datasheet), 600 W maximum output power, and a wide 250 V to 425 V input window that maps directly onto 380 V PFC front-end rails in three-phase industrial systems. Line and load regulation are specified at ±0.25% from no load to full load, the module withstands 500 V input surges for 100 ms, and the through-hole Full Brick footprint provides a thermally conductive baseplate rated for -40 °C to +100 °C operation with forced air or conduction cooling.

Architecturally, the converter uses a zero-current-switching quasi-resonant topology with Vicor's proprietary secondary-side control, which keeps the output ripple low without external LC filtering and simplifies paralleling. The high switching frequency (typically several hundred kHz) is decoupled from the input-to-output path by the internal transformer, eliminating the common-mode / differential-mode choke design work that bulk discrete regulators usually demand.

Typical applications include industrial automation PLC backplanes fed from 380 V three-phase buses, telecom BTS and access-node 24 V/28 V distribution, railway auxiliary and rolling-stock power, ATE and semiconductor test rack power, and high-power LED drivers. The 28 V rail is also widely used as an intermediate bus for downstream point-of-load converters in computing and defense platforms.

When designing with this module, allocate a flat copper pad or forced-air path for the baseplate: the module dissipates roughly 14% of output power at full load (about 80-100 W) and must reject that heat through its baseplate rather than through the pins. Follow Vicor's recommended inrush and hold-up circuitry to keep within the 500 V transient rating, and observe creepage / clearance distances on the primary side to maintain the input-to-isolation voltage rating specified in the datasheet.

This page synthesizes distributor pricing, drop-in same-package variants from the same Vicor Maxi family, and practical design notes that complement - and go beyond - what appears in the manufacturer's datasheet page.

直接替换替代料: V375A28H600BG ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

快速对比工具——选择替代料号进行并排对比:

V375A28H600BL

✅ 直接替换
📦 Full Brick, Through-Hole
Same Maxi Full Brick footprint and terminals; trailing-letter option variant per FindIC 'Completely replace' classification; param_match within ±5%.

📋 参考替代料(不在目录中)

V375A28H600BN

✅ 直接替换
📦 Full Brick, Through-Hole
Same Maxi Full Brick footprint and terminals; FindIC 'Completely replace' - main performance consistent, terminals consistent, no PCB mod required.

📋 参考替代料(不在目录中)

V375A28H600BN2

✅ 直接替换
📦 Full Brick, Through-Hole
Same Vicor Maxi 28 V/600 W family, Full Brick Through-Hole package; trailing-letter option variant - terminals and package consistent.

📋 参考替代料(不在目录中)

V375A28H600BG 最大额定值与电气特性

拓扑 Isolated DC-DC converter module (Maxi family)
输出电压 28 V nominal (programmable 2.8 V to 30.8 V)
Maximum Output Power 600 W
Output Current 29.9 A (peak); 21.4 A steady per datasheet snippet
输入电压范围 250 V to 425 V DC
Input Surge Withstand 500 V for 100 ms
Output Power Rating (other listing) 400 W (0.5361 HP) per third-party listing
Line/Load Regulation ±0.25% (no load to full load)
Programmable Output Range to 110% of nominal
Isolation Voltage Isolated (per datasheet)
工作温度 -40 °C to +100 °C
封装 Full Brick, Through-Hole
安装类型 Through Hole (board mount module)
Output Channels 1
Module Family Vicor Maxi Series

V375A28H600BG full brick, through-hole 引脚配置指南

V375A28H600BG(full brick, through-hole 封装)的引脚配置。 该功率器件具有栅极、漏极和源极端子。对于无极性封装,请参阅制造商数据手册以了解确切的引脚 1 方向和封装尺寸细节。常见应用包括电源设计、电机驱动和负载开关。

V375A28H600BG 的 full brick, through-hole 封装引脚图

暂无详细引脚数据: V375A28H600BG.

请参阅 数据手册 以查看完整引脚配置。

典型应用

V375A28H600BG 适用于 6 应用s: Industrial 380 V Three-Phase Bus to 28 V Power, Telecom 380 V DC Distribution to 28 V Sub-Rail, Railway and Rolling-Stock Auxiliary Converters, ATE and Semiconductor Test Equipment Rack Power, High-Power LED Driver and Stage Lighting, Defense and Avionics 270 V DC Intermediate Bus.

🏭

Industrial 380 V Three-Phase Bus to 28 V Power

The V375A28H600BG is designed for a 250 V to 425 V DC intermediate bus - the natural output of a 380 V three-phase PFC front end used in industrial cabinets. With 600 W available, a single module can feed an entire 28 V backplane that powers PLCs, sensors, contactors and motor drives. Its ±0.25% regulation from no load to full load keeps analog I/O rails within tolerance without post-regulators. The 500 V input surge withstand for 100 ms also absorbs line-side transients on the shop floor without nuisance trips.

🌐

Telecom 380 V DC Distribution to 28 V Sub-Rail

Modern telco and datacom central offices increasingly use a 380 V HVDC distribution bus instead of -48 V to cut copper losses. The V375A28H600BG sits directly on that bus and produces 28 V at 600 W with Vicor's low-noise ZCS topology. Compared with discrete front-end converters, it eliminates EMI filtering work, and its galvanic isolation simplifies the SELV / hazardous-voltage boundary. At 28 V the output can feed a downstream point-of-load regulator block (Vicor DCM or PRM) when individual sub-cards need 1-12 V rails.

🚂

Railway and Rolling-Stock Auxiliary Converters

Rolling-stock auxiliary power systems often derive an intermediate 600 V or 750 V DC bus from the catenary/3rd-rail rectifier. The V375A28H600BG's 250 V-425 V input window (after converter's input converter you may need a step-down) is well adapted to the dc-link feeding body-control loads, lighting, door drives and HVAC controls on board. The 600 W headroom covers multi-rail loads, while -40 °C to +100 °C baseplate rating handles the under-thermal-chamber conditions typical of train cabinetry.

🖥️

ATE and Semiconductor Test Equipment Rack Power

ATE platforms demand very low noise 28 V rails for analog and mixed-signal instrumentation. The V375A28H600BG's ZCS topology keeps output ripple low and the input-to-output isolation eliminates ground loops between the rack chassis and the device under test. At 600 W it can power multiple test-head boards simultaneously, and the Full Brick baseplate simplifies integration into chassis that already use conduction cooling. Engineers commonly combine this module with downstream Vicor PRM / VTM chains for sub-volt domains below 12 V.

💡

High-Power LED Driver and Stage Lighting

Stage lighting fixtures need isolated, regulated 28 V or 36 V rails to drive long LED chains and dim. The V375A28H600BG's 2.8 V to 30.8 V programmable output window lets designers use one part across both 24 V and 28 V fixture families. Its 600 W budget means a single module can drive multiple fixtures on an installed rack, and its high efficiency keeps heat-rejection budgets realistic in truss-mounted gear where space for heat sinks is limited.

✈️

Defense and Avionics 270 V DC Intermediate Bus

Mil-aero platforms increasingly run on a 270 V DC intermediate bus derived from generators or fuel cells. The V375A28H600BG's 250 V-425 V input range directly accommodates that bus and isolates the downstream sub-rails (28 V/avionics, 5 V mission computing) from the high-voltage side. The 500 V surge withstand handles engine-start transients specified by MIL-STD-704. The Full Brick through-hole package and the thermal baseplate support both conduction-cooled chassis (per MIL-STD-810) and forced-air cabinets.

推荐产品汇总

V375A24M600BL Vicor Maxi sibling on the same 380 V bus, 24 V/600 W output for legacy industrial backplanes 用于: Industrial 380 V Three-Phase Bus to 28 V Power, High-Power LED Driver and Stage Lighting V375B48H200BL Vicor Mini sibling on the same bus, 48 V/200 W output for telecom sub-rails 用于: Industrial 380 V Three-Phase Bus to 28 V Power, Telecom 380 V DC Distribution to 28 V Sub-Rail VTM48EF040T050A00 Vicor VTM factor - downstream isolation point-of-load fed from a 28 V PRM/DCM chain 用于: Telecom 380 V DC Distribution to 28 V Sub-Rail, ATE and Semiconductor Test Equipment Rack Power V375A12H600BL Vicor Maxi sibling at 12 V for lighting and door drives on the same bus 用于: Railway and Rolling-Stock Auxiliary Converters, Defense and Avionics 270 V DC Intermediate Bus V375A48H600BL Vicor Maxi sibling at 48 V for controller and HVAC sub-rails 用于: Railway and Rolling-Stock Auxiliary Converters PRM48JH480T250A00 Vicor PRM chip - upstream / downstream factor on 28 V bus for sub-V domains 用于: ATE and Semiconductor Test Equipment Rack Power V375A36H600BL Vicor Maxi sibling at 36 V/600 W for 36 V LED chains on the same bus 用于: High-Power LED Driver and Stage Lighting V375A28H600BLQ Vicor Maxi family variant selected for military/avionics designs - confirm with Vicor factory 用于: Defense and Avionics 270 V DC Intermediate Bus
What is the V375A28H600BG and what does it do?
The V375A28H600BG is a Vicor Maxi-series isolated DC-DC converter module that delivers 28 V at up to 600 W from a 250 V to 425 V DC input bus. It uses zero-current-switching quasi-resonant topology and provides ±0.25% line/load regulation, 500 V input-surge withstand for 100 ms, and a 2.8 V to 30.8 V programmable output range in a through-hole Full Brick package.
What input voltage range does the V375A28H600BG accept?
According to the Vicor datasheet snippet, the V375A28H600BG accepts an input range of 250 V to 425 V DC. It is designed to ride directly on the DC output of a three-phase 380 V PFC front end and can withstand transients up to 500 V for 100 ms without latch-up. This makes it well matched to industrial 380 V and 400 V bus environments.
How much output power and current can the V375A28H600BG deliver?
The V375A28H600BG is rated for 600 W of output power with a peak output current of 29.9 A and a steady-state current of 21.4 A, per the Vicor product page. One distributor listing also reports 400 W (0.5361 HP) as a secondary rating - engineers should confirm the active rating with the orderable part's factory datasheet before committing to a thermal design.
Where can I download the V375A28H600BG datasheet PDF?
The official Vicor product page for the V375A28H600BG Maxi DC-DC Converter is available at https://www.vicorpower.com/products?productKey=V375A28H600BG&productType=cfg and links to the full datasheet along with mechanical drawings and application notes. Distributor datasheets are also mirrored at DigiKey (page 2851305) and Mouser.
Is the V375A28H600BG in stock at distributors?
As of 2026-10-14, DigiKey lists the V375A28H600BG as 'ships today' through its board-mount inventory, and third-party aggregators such as JAK Electronics report stock holding around 5,652 pieces with December-January lead times. Octopart currently aggregates two distributors with bulk-tier discounts - check those pages live for real-time quantity and pricing.
What is the price of the V375A28H600BG?
As of 2026-10-14, distributor pricing for the V375A28H600BG sits in the mid-hundreds of USD depending on volume break. Tiered indicative pricing on this page runs from approximately $387 at qty 1 down to roughly $287 at qty 1000 (reference only); live distributor prices should always be confirmed on DigiKey, Mouser, or Vicor direct before issuing a purchase order.
What is the lead time for the V375A28H600BG?
As of 2026-10-14, DigiKey indicates same-day shipping for stocked V375A28H600BG orders, while independent distributors report general lead times of about one week with expedited options. Vicor's own direct-channel quoting (the 'order direct from Vicor' path on the product page) typically takes two to four weeks depending on quantity and configuration.
What is the difference between V375A28H600BG and V375A28H600BL?
According to the FindIC cross-reference for V375A28H600BG vs V375A28H600BL, both parts share the same family and the same Full Brick pinout - the terminal layout and functional characteristics are consistent enough that one can replace the other without PCB modification. The trailing letter typically denotes a packaging or test-screen variation, so engineers should compare voltage trim, hold-up, and baseplate options in the datasheet before treating them as truly drop-in.
What is the difference between V375A28H600BG and V375A28H600BN?
V375A28H600BN is the same Vicor Maxi-series family member with identical terminals and packages as V375A28H600BG per FindIC cross-reference data; FindIC explicitly notes 'Completely replace - main performance parameters are consistent and terminals are consistent; replacement does not require modification.' The trailing-letter code usually indicates a minor option (e.g., lead trim, baseplate finish) that you should confirm against the latest datasheet before committing.
When should I choose V375A28H600BG over a discrete DC-DC design?
Choose the V375A28H600BG when you need a guaranteed-isolated 28 V rail above ~400 W with agency-recognized EMI behavior and minimum PCB area, and when the 250 V to 425 V DC bus already exists in your system (such as after a three-phase PFC front end). Prefer a discrete buck or LLC design only when the input bus is below 150 V, when output power is under about 200 W, or when cost is more important than time-to-market and isolation certification.
What is a drop-in replacement for the V375A28H600BG?
Within the Vicor Maxi family the closest drop-in substitutes sharing the same Full Brick footprint and 28 V/600 W window are V375A28H600BL and V375A28H600BN - both verified as terminal- and package-compatible. Engineers should match the exact suffix against the latest Vicor datasheet before swapping. Cross-brand equivalents in brick DC-DCs are not general-purpose drop-in candidates because through-hole mounting dimensions and baseplate styles differ between vendors.
Can I use the V375A28H600BG at lower input voltages like 200 V?
The V375A28H600BG is specified for a 250 V minimum input and should not be operated continuously below that threshold, otherwise the converter will simply drop out of regulation and likely assert its under-voltage lockout. Below 250 V, choose a Mini-series part or one of Vicor's 24 V / 28 V / 48 V input Maxi modules that have a lower V_in(min) rating - they share the same Full Brick option key letter scheme for easy reselection.
Does the V375A28H600BG need an external inrush limiter?
Vicor modules are designed to be used with their recommended hold-up and inrush network around the input pins; consult the Vicor Maxi datasheet and the associated application note for the exact resistor/capacitor values. Skipping the input hold-up section can cause nuisance trips on the upstream breaker during hot-plug events and prevent full-rated 500 V transient survival even though the module itself is rated to withstand the surge.
What cooling does the V375A28H600BG require?
The Maxi Full Brick dissipates roughly 80 to 100 W at full 600 W output and must reject that heat through its baseplate using either a heat sink, cold-plate, or significant airflow - Vicor's datasheet specifies derating curves for both conduction and forced-air cooling. Without a thermal path the baseplate will trip OTP at around 100 °C, derating the output long before you reach the rated current.
Where to buy the V375A28H600BG online?
As of 2026-10-14, the V375A28H600BG can be purchased from DigiKey (https://www.digikey.com/en/products/detail/vicor-corporation/V375A28H600BG/2851305), Mouser (vicor sku search), Vicor Direct (vicorpower.com), and JAK Electronics (jakelectronics.com/productdetail/9961423). For volume above a few hundred units, request a quote from Vicor Direct for the best pricing and shortest allocation lead time.

工程参考数据: V375A28H600BG ——对比、设计指导和合规信息。

选型指南

Choose the V375A28H600BG when your system already produces a 250 V to 425 V DC intermediate bus (e.g., a 380 V three-phase PFC or a 270 V dc-link in military platforms) and you need a single, agency-recognized point-of-source for an isolated 28 V / 600 W rail. It is a particularly good fit where predictable EMI, elimination of discrete inrush / hold-up work, and rapid time-to-market outweigh unit-cost optimization. Prefer the trailing-letter variants (V375A28H600BL, V375A28H600BN, or BN2) when availability on the base P/N is constrained but the same Full Brick footprint and pinout are required. Avoid this part if the upstream DC bus is below 150 V - choose a Vicor 24 V/28 V/48 V or 110 V input Maxi module instead - and avoid it if output power is well under 200 W, where a Mini-series Vicor brick would be cheaper per watt.

与替代料对比

参数 本产品 V375A28H600BL V375A28H600BN V375A28H600BN2
Brand Vicor Vicor Vicor Vicor
Package Full Brick, Through-Hole Full Brick, Through-Hole Full Brick, Through-Hole Full Brick, Through-Hole
Output Voltage 28 V (2.8 V to 30.8 V programmable) 28 V (programmable) 28 V (programmable) 28 V (programmable)
Output Power 600 W 600 W 600 W 600 W
Input Voltage Range 250 V to 425 V 250 V to 425 V 250 V to 425 V 250 V to 425 V
Input Surge Withstand 500 V for 100 ms 500 V for 100 ms 500 V for 100 ms 500 V for 100 ms
Regulation (no load to full load) ±0.25% ±0.25% ±0.25% ±0.25%
Operating Temperature -40 °C to +100 °C -40 °C to +100 °C -40 °C to +100 °C -40 °C to +100 °C

关键差异点

  • Wide-input Maxi family is built for 380 V three-phase bus power without an additional front-end converter (对比 Discrete 28 V brick built from an LLC + rectifier on the same bus)
  • Documented same-footprint trailing-letter variants from the same Vicor Maxi series (对比 Any non-Vicor brick on the same bus)
  • 500 V input surge withstand for 100 ms is documented in the datasheet snippet (对比 Lower-voltage-input Vicor Maxi parts (24/48/72/110 V Maxi siblings))

设计说明

Estimated: at 600 W output and 86% efficiency (typical for ZCS Maxi on a 380 V bus), the V375A28H600BG dissipates about 97 W in the baseplate. Without a heat sink or cold-plate the junction will rapidly exceed the -40 °C to +100 °C operating window. Provide either a 200-300 LFM airflow directly on the baseplate, or bolt the baseplate to a 150 mm × 150 mm aluminum cold-plate with thermal interface material. Derate output current roughly linearly from 100 °C baseplate to 110 °C absolute maximum.

Solder the through-hole pins to a thermally massive copper pour on both primary and secondary sides; Vicor recommends at least 2 oz copper on a 4-layer PCB at 1 oz on the inner two layers directly beneath the brick. Keep primary-side (250 V-425 V) and secondary-side (28 V) copper pours well separated to preserve the isolation voltage rating and meet the creepage / clearance listed in the datasheet. Always mount the baseplate to chassis ground or a floating cold-plate per the datasheet's mechanical drawing.

Estimated: hot-plugging a 600 W load onto the 28 V output without the Vicor-recommended hold-up / inrush network will cause a fast inrush surge that the upstream 28 V bus cannot tolerate, and the brick's input fuse may open. Always include Vicor's standard hold-up circuit (a few µF of hold-up capacitor plus a charging resistor) on the input when downstream loads are hot-plug capable, and never parallel two bricks into a single output without the Vicor MicropTM-style OR'ing network - otherwise one unit will source-back into the other.

Place the input fuse, optional EMI filter, and hold-up capacitor within 30 mm of the input pins to keep the input loop area small. Vicor Maxi modules are robust to common-mode EMI but loop-sensitive to differential-mode ringing - 20-30 mm of copper trace is short enough to avoid emitting pulses back onto the input bus. On the secondary side, keep the output capacitor bank tight to the brick's output pins and star-ground its return to a single point near the brick's secondary-side GND pin.

Although the ZCS topology generates less conducted EMI than hard-switched designs, large industrial systems still benefit from a small CM choke on the input when the brick is part of an EN 55011 / EN 55032 emission-tested product. For military and avionics applications reference Vicor's application note on EMI filtering for Maxi modules and add a CM filter plus a small shield around the baseplate to suppress radiated emissions above 30 MHz.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

Compliance fields not stated in the provided data snippets. Vicor publishes full RoHS / REACH / conflict-mineral declarations on the product page; check https://www.vicorpower.com/products?productKey=V375A28H600BG&productType=cfg for the official document references.

数据核验日期: 2026-10-14 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

V375A28H600BG datasheet V375A28H600BG Vicor V375A28H600BG price V375A28H600BG buy Vicor Maxi 28V 600W isolated DC-DC Full Brick DC-DC converter 380V input V375A28H600BG vs V375A28H600BL V375A28H600BG equivalent V375A28H600BG pinout V375A28H600BG industrial DC-DC Vicor DC-DC converter 380V three-phase bus How much power does V375A28H600BG deliver

相关元器件 & 术语

Vicor V375A28H600BG V375A28H600BL V375A28H600BN V375A28H600BN2 Maxi series Full Brick DC-DC converter isolated DC-DC converter PFC 380 V DC bus 270 V DC MIL-STD-704 RoHS REACH Vicor PRM Vicor VTM industrial automation telecom railway rolling stock ATE zero-current switching ZCS hold-up capacitor inrush limiter
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情