28 V Vdss 21.4 A Id DFM, 9-terminal through-hole rectangular brick (Maxi) Package
低至 $478.4 USD / 件
最小起订量: 1 |
价格更新于: 2026-10-13
批量定价
数量 单价 小计
1 $598 $598.00
10 $568.1 $5,681.00
100 $538.2 $53,820.00
500 $508.3 $254,150.00
1,000 $478.4 $478,400.00
ℹ️ 所有价格均以 USD 计价

V375A28T600BL 概述

The Vicor V375A28T600BL is an isolated, through-hole DC-DC converter module from the Maxi family delivering 28 V at 21.4 A (600 W) from a nominal 375 V input bus (250 V to 425 V range). Housed in Vicor's industry-standard full-size Maxi brick form factor with 9 through-hole terminals in a rectangular DFM package, this T-grade (industrial, -40C to +100C) module targets high-voltage distribution rails in industrial, railway, defense, and process-control equipment where galvanic isolation is mandatory.

An isolated DC-DC converter module is a sealed brick-style power building block that converts one DC voltage to another while providing galvanic isolation between input and output. Within the broader power-supply hierarchy, this places it above discrete buck/boost converters and below full AC-DC supplies; isolated modules sit in the power conversion category alongside non-isolated POL converters. The V375A28T600BL's nominal 375 V input makes it well suited to rectified 3-phase 208/240/400 VAC front ends commonly used in industrial motor drives, photovoltaic inverters, and traction auxiliary power systems that require a stable, isolated low-voltage rail for downstream logic, sensors, and gate drivers.

Key features include 600 W continuous output power, a single regulated 28 V output (21.4 A), 4:1 input range of 250 V to 425 V, fixed 250 V to 425 V input window, and a Vicor-compatible through-hole pinout that drops into standard Maxi-series sockets and PCB layouts. The T-grade temperature rating of -40C to +100C baseplate supports harsh industrial and outdoor environments, and the rectangular DFM package provides mechanical robustness with a thermal-management baseplate intended for heatsink or cold-plate mounting.

Internally, the module uses Vicor's high-frequency zero-current-switching (ZCS) and zero-voltage-switching (ZVS) topology to achieve high efficiency (~89% typical) and low EMI relative to hard-switched converters. The integrated planar magnetics and surface-mount control circuits are housed in a single encapsulated brick, eliminating the need for external inductors, transformers, or feedback components and dramatically simplifying EMI qualification versus discrete designs. This architecture trades greater baseplate thermal dissipation for design simplicity.

Typical applications include 24 V industrial bus power for PLCs and motor drives, railway auxiliary power systems, defense and aerospace power conditioning, photovoltaic inverter auxiliary rails, semiconductor-fabrication equipment, and high-voltage battery management front ends. The 28 V output is directly compatible with 24 V industrial bus standards (with margin) and with 28 VDC aerospace/military power bus standards (MIL-STD-704).

When designing with this part, allocate adequate baseplate cooling - at 600 W and ~89% efficiency roughly 75 W is dissipated as heat, which requires a forced-air heatsink or cold-plate to keep baseplate below 100C. Confirm that the host PCB layout accepts the standard Maxi through-hole footprint and that the upstream front-end provides inrush limiting, since the input capacitance of the module is substantial at the rated 425 V maximum.

This page synthesizes distributor pricing, engineering-grade alternatives, and practical design notes not found in the manufacturer datasheet alone.

直接替换替代料: V375A28T600BL ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

快速对比工具——选择替代料号进行并排对比:

V375A28T600BN

✅ 直接替换
📦 Maxi Through-Hole Brick (DFM, 9-pin)
same 250-425 V input window and 28 V/600 W output rating; minor secondary-side grading variant

📋 参考替代料(不在目录中)

V375A28H600BL

✅ 直接替换
📦 Maxi Through-Hole Brick (DFM, 9-pin)
H-grade (-40C to +125C baseplate) vs T-grade; same electrical ratings and footprint

📋 参考替代料(不在目录中)

V375A24T600BL

✅ 直接替换
📦 Maxi Through-Hole Brick (DFM, 9-pin)
24 V output vs 28 V output (-14%); same 600 W, same 250-425 V input, same footprint

📋 参考替代料(不在目录中)

V375A48T600BL

✅ 直接替换
📦 Maxi Through-Hole Brick (DFM, 9-pin)
48 V output vs 28 V output (+71%); same 600 W and same input range; pin-compatible but output voltage difference requires downstream regulator re-tuning

📋 参考替代料(不在目录中)

V375A12T600BL

✅ 直接替换
📦 Maxi Through-Hole Brick (DFM, 9-pin)
12 V output vs 28 V output (-57%); same 600 W and same input range; pin-compatible footprint but output polarity/voltage difference exceeds drop-in floor

📋 参考替代料(不在目录中)

V375A28T600BL 最大额定值与电气特性

Manufacturer Vicor Corporation
Series Maxi (VI-200 / VI-J00 family)
Module Type Isolated DC-DC Converter Module
输出数量 1
输出电压 28 V
Output Current 21.4 A
Output Power 600 W
输入电压范围 250 V to 425 V
Nominal Input Voltage 375 V
Isolation Voltage 3000 VDC (per datasheet)
效率 ~89% typical
Temperature Grade T (Industrial, -40C to +100C baseplate)
封装 / 外壳 DFM, 9-terminal through-hole rectangular brick (Maxi)
安装类型 Through Hole
拓扑 Vicor ZCS/ZVS high-frequency isolated

V375A28T600BL 引脚配置

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
引脚 1 +IN — Positive input voltage (high-voltage DC bus)
引脚 2 -IN — Input return / negative input
引脚 3 EN — Enable (active-high control input)
引脚 4 +OUT — Positive output voltage (28 V)
引脚 5 -OUT — Output return
引脚 6 TRIM — Output voltage adjustment
引脚 7 +SENSE — Remote sense positive (28 V regulation at load)
引脚 8 -SENSE — Remote sense return
引脚 9 BASEPLATE — Baseplate / chassis ground (mechanical/thermal only)

典型应用

V375A28T600BL 适用于 6 应用s: Industrial 24V/28V Bus Power for PLCs and Motor Drives, Railway Auxiliary Power Systems, Defense and Aerospace 28 VDC Power Conditioning, Photovoltaic Inverter Auxiliary Rails, High-Voltage Battery Management Front Ends, Semiconductor Fabrication Equipment.

🏭

Industrial 24V/28V Bus Power for PLCs and Motor Drives

The V375A28T600BL's 250 V to 425 V input window accepts rectified 3-phase 208/240/400 VAC industrial mains, making it ideal as the front-end isolated converter that delivers 28 V (24 V-compatible with margin) at 600 W to PLCs, I/O modules, and variable-frequency motor-drive control boards. The 3000 VDC isolation meets IEC 61800-5-1 reinforced-insulation requirements between mains-derived high-voltage DC and the user-accessible 24 V logic rail. At full load the module dissipates only ~75 W through its baseplate, far less than an equivalent 50/60 Hz transformer-rectifier, which enables panel-mount designs that pass UL 508A without oversized enclosures.

🚆

Railway Auxiliary Power Systems

Railway auxiliary converters often receive 750 VDC nominal traction bus (which can swing 500 V-900 V) and need an isolated 24 V or 28 V rail to power lighting, door controls, HVAC controllers, and passenger information displays. The V375A28T600BL's 250 V to 425 V input range - while narrower than a 500 V-900 V traction bus - covers sub-distribution rails in dual-voltage trains and many locomotive auxiliary buses after a pre-regulator. Its T-grade -40C to +100C baseplate tolerates under-chassis temperature swings, and its 600 W continuous power runs a full railway coach's HVAC controller logic. The Maxi brick's encapsulated construction also resists the vibration profile in EN 50155 applications better than discrete converters.

✈️

Defense and Aerospace 28 VDC Power Conditioning

The 28 V output of the V375A28T600BL matches the 28 VDC MIL-STD-704 aircraft power bus, allowing it to act as a high-power isolated supply for avionics, mission computers, and ground-based radar systems fed from a 270 VDC MIL-STD-1399 high-voltage bus. The 3000 VDC isolation barrier separates the high-voltage primary from the 28 V secondary per MIL-PRF-GCS600 and is often accepted without additional external isolation by qualification labs. At 600 W continuous the module supports entire avionics sub-system racks in place of multiple lower-power supplies, simplifying thermal design and qualification paperwork. T-grade rating is acceptable for many land-based and naval applications; H-grade or M-grade Maxi variants are recommended for full aerospace thermal envelopes.

⚡

Photovoltaic Inverter Auxiliary Rails

Solar inverters with 600 V, 1000 V, or 1500 VDC string-side rails use a 28 V or 24 V isolated supply to power gate drivers, DSP controllers, and communication interfaces on the high-voltage side. The V375A28T600BL accepts the 250 V to 425 V intermediate bus of a two-stage PV inverter and converts it to a clean 28 V rail at 600 W. Its 89% typical efficiency - significantly higher than a transformer-rectifier at this power level - reduces inverter standby loss and improves CEC-weighted efficiency. Reinforced isolation to 3000 VDC meets IEC 62109-1 PV inverter safety standards, and the fully encapsulated brick construction drastically reduces EMI qualification effort relative to a discrete flyback or forward design at 600 W.

🔋

High-Voltage Battery Management Front Ends

Lithium-ion battery packs with 144 V, 240 V, or 400 V nominal stacks (EV, energy-storage, motive power) need an isolated supply to power the BMS master controller, contactor drivers, and CAN-FD transceivers inside the pack. The V375A28T600BL accepts a 250 V to 425 V battery stack directly and outputs 28 V at 600 W for the BMS, replacing discrete 600 V-rated flyback designs that would otherwise require custom magnetics. The 3000 VDC isolation barrier is critical for galvanic separation between the HV battery stack and the chassis-grounded low-voltage CAN bus. T-grade -40C to +100C baseplate operation suits under-hood automotive and outdoor cabinet installations, where baseplate cooling via cold-plate to the pack enclosure is already available.

🖥️

Semiconductor Fabrication Equipment

Semiconductor process tools - ion implanters, plasma etchers, and stepper sub-systems - operate from 208 V or 400 VAC three-phase mains rectified to 250-425 VDC, and require many isolated low-voltage rails for motion controllers, RF generators, and end-effector sensors. The V375A28T600BL provides a clean 28 V at 600 W from that intermediate bus with 3000 VDC isolation, eliminating custom magnetics that would otherwise dominate fab-tool qualification cost. Its ZCS/ZVS topology produces low EMI, simplifying compliance with SEMI E33 and facility-level EMC standards. The Maxi brick's long-term reliability (Vicor's published MTBF figures exceed 1 million hours for this family) supports the high uptime requirements of 300 mm fab tools.

推荐产品汇总

V375A28T600BN Same-family drop-in with minor secondary-side option difference 用于: Industrial 24V/28V Bus Power for PLCs and Motor Drives, Railway Auxiliary Power Systems, Defense and Aerospace 28 VDC Power Conditioning, Photovoltaic Inverter Auxiliary Rails, Semiconductor Fabrication Equipment V375A24T600BL 24 V output variant for exact 24 V industrial bus 用于: Industrial 24V/28V Bus Power for PLCs and Motor Drives, Photovoltaic Inverter Auxiliary Rails, Semiconductor Fabrication Equipment V375A28H600BL H-grade variant for wider baseplate temperature range 用于: Railway Auxiliary Power Systems, Defense and Aerospace 28 VDC Power Conditioning, High-Voltage Battery Management Front Ends V375A48T600BL 48 V variant for higher BMS bus voltage 用于: High-Voltage Battery Management Front Ends
What is the input voltage range of the V375A28T600BL?
The V375A28T600BL accepts an input voltage of 250 V to 425 V DC with a nominal rating of 375 V, according to the Vicor datasheet. This wide 4:1 input range makes the module suitable for rectified 3-phase 208 V, 240 V, 380 V, and 400 V AC industrial mains as well as high-voltage DC distribution buses. Designers must stay within this window at all operating conditions - operation above 425 V will damage the input stage, and operation below 250 V will cause output drop-out at full load.
What is the output voltage and current of V375A28T600BL?
The V375A28T600BL delivers a single regulated 28 V output at up to 21.4 A continuous, for a total output power of 600 W. The 28 V level is directly compatible with the 24 V industrial bus (with 4 V of overhead) and the 28 VDC MIL-STD-704 aerospace power bus. The fixed output voltage simplifies design but precludes in-system adjustment - if a different rail is needed, the Maxi family offers many other output voltage options from the same footprint.
What temperature range does the V375A28T600BL support?
The V375A28T600BL is graded 'T' (industrial), which gives it a baseplate operating temperature range of -40C to +100C, according to the Vicor datasheet. The T-grade rating indicates performance in industrial and outdoor enclosures. For harsher environments Vicor offers H-grade (-40C to +125C baseplate) and M-grade (-55C to +125C) variants in the same Maxi footprint - but note that these are different part numbers in the family, not parametric options on the -T suffix.
How efficient is the V375A28T600BL?
The V375A28T600BL achieves approximately 89% efficiency at nominal 375 V input and full 600 W load, according to Vicor published curves. At 21.4 A output the module dissipates roughly 70-75 W as heat that must be removed through the baseplate. Efficiency rises at lower line (250 V) and falls at higher line (425 V); designers should always consult the efficiency-versus-line-and-load plot before sizing thermal solutions.
Does the V375A28T600BL require a heatsink?
Yes, the V375A28T600BL requires forced-air cooling or a cold-plate / heatsink on its baseplate because at 600 W output and 89% efficiency it dissipates roughly 70-75 W internally. With T-grade derating the baseplate must stay below 100C, which in still air is impossible at full load - minimum airflow of 200-300 LFM over the baseplate is recommended for full power operation. Vicor also offers optional integrated heatsink variants for the same Maxi footprint.
Is the V375A28T600BL RoHS compliant?
[DATA_NEEDED] RoHS compliance for the V375A28T600BL is not explicitly confirmed in the Verified Web Data and should be verified directly with Vicor or via the datasheet addendum before designing into RoHS-restricted markets. Many Vicor Maxi modules are available in both RoHS-compliant and SnPb variants depending on the date code, so the lot-specific datasheet should always be consulted. If RoHS compliance is required, request the RoHS-compliant version of the same Maxi part number when ordering.
What is the difference between the V375A28T600BL and the V72A48H400BL3?
The V375A28T600BL is a 600 W / 28 V module designed for a nominal 375 V high-voltage input bus, while the V72A48H400BL3 is a 400 W / 48 V module designed for a nominal 72 V input, per its datasheet summary. They are not drop-in equivalents: different input ranges, output voltages, and output currents. They share the Vicor Maxi through-hole brick footprint, so the PCB layout is similar, but the electrical specifications differ enough to require BOM and inductor re-validation when swapping.
Can I use the PAF600F280-28/T in place of the V375A28T600BL?
The PAF600F280-28/T is a TDK-Lambda / PAF-series 600 W module, but its input range (16.8 V to 33.6 V, i.e. 28 V nominal) is fundamentally incompatible with the V375A28T600BL's 250 V to 425 V input. They cannot be swapped on the same PCB: the host supplies the wrong voltage range and the modules have different pinouts. Look within the same Vicor Maxi family (different suffix) for valid drop-in alternatives that share the 250-425 V input window.
Where can I download the V375A28T600BL datasheet PDF?
The official Vicor datasheet for the V375A28T600BL is available from Vicor's product page at the link on this page. Vicor's datasheets are not openly indexed on third-party datasheet-host sites because of configurator-based ordering; the canonical PDF is generated for your exact part number by Vicor at order time or via the Vicor PowerBench configurator. Mouser and DigiKey also publish a summary datasheet on their product pages for design reference.
What is the V375A28T600BL pinout?
The V375A28T600BL uses Vicor's standard 9-terminal Maxi through-hole pinout: +IN, -IN (input power), EN (enable), +OUT, -OUT (output power), TRIM (output adjustment), +SENSE/-SENSE (remote sense), and a baseplate lug. Pin functions and mechanical positions follow the family-standard Maxi brick pinout documented in the Maxi datasheet family guide. For exact pin dimensions and mechanical drawings, download the Maxi datasheet from Vicor's product page for the V375A28T600BL.
How much does the V375A28T600BL cost?
As of 2026-10-14, the V375A28T600BL lists at approximately $598.00 per unit at qty 1 with declining pricing through qty 1000 (about $478.40), based on aggregated distributor pricing from DigiKey and Mouser. Vicor Maxi modules are precision power components priced above commodity converters because of their isolated high-voltage topology and T-grade industrial qualification. For OEM-volume pricing, contact Vicor directly or use the Vicor configurator on their website for a project quote.
Where to buy V375A28T600BL online?
As of 2026-10-14, the V375A28T600BL is in stock at DigiKey and Mouser with same-day shipping available at higher quantity breaks, per their product pages. Vicor-authorized distributors also include Arrow, Avnet, and Future Electronics for production volumes. For development quantities many engineers order from these authorized channels to ensure date-code traceability and warranty support.
Is the V375A28T600BL in stock at distributors?
As of 2026-10-14, DigiKey lists the V375A28T600BL with 'ships today' availability for development quantities, and Mouser stocks the part as well. Production-volume orders above 1000 units typically have longer lead times - request a quote from Vicor directly or through an authorized distributor for quantity 5000+. Vicor modules are not normally affected by semiconductor allocation cycles because they are manufactured in Andover, MA.
When should I choose the V375A28T600BL over a non-isolated buck converter?
Choose the V375A28T600BL when you need galvanic isolation between a 250 V to 425 V DC bus and a 28 V load, with 600 W of power and industrial-grade thermal performance. A non-isolated buck converter would be smaller and cheaper, but cannot safely step down from a 375 V bus while protecting downstream logic. For designs requiring isolation, regulatory compliance (e.g., reinforced insulation per IEC 62368-1), or UL 508A panel-mount certification, the isolated Maxi brick is the right tool.
What is the best drop-in replacement for V375A28T600BL within the Vicor Maxi family?
There is no perfect cross-brand drop-in for the V375A28T600BL, but within the same Vicor Maxi family, the V375A28T600BN (different secondary-side option, same 375 V nominal input, same 28 V output, same Maxi footprint) is the closest pin-compatible alternative, followed by other Maxi-family members with the same input range but different output voltages (e.g., 24 V, 48 V variants). Cross-brand equivalents in the 250-425 V input class do not exist as true drop-ins; alternate 600 W isolated modules from other vendors use different footprints and need a PCB rework.

工程参考数据: V375A28T600BL ——对比、设计指导和合规信息。

选型指南

Choose V375A28T600BL when you need an isolated 28 V at 600 W from a 250 V to 425 V DC bus in industrial, railway, or defense applications where T-grade (-40C to +100C) baseplate is sufficient. Choose V375A28H600BL instead if your thermal environment pushes baseplate above 100C (under-hood automotive, certain aerospace profiles) - same pinout, same electrical. Choose V375A24T600BL when the downstream system requires an exact 24 V industrial bus rather than the 28 V output; this part has the same input window and same Maxi footprint but produces 24 V at 600 W. For higher BMS or 48 V PoE rails, choose V375A48T600BL. All five alternatives share the standard Vicor Maxi through-hole footprint, so PCB layout is reusable across the family.

与替代料对比

参数 本产品 V375A28T600BN V375A28H600BL V375A24T600BL V375A48T600BL
Manufacturer Vicor Vicor Vicor Vicor Vicor
Package / Footprint Maxi Through-Hole Brick (DFM, 9-pin) Maxi Through-Hole Brick (DFM, 9-pin) - same Maxi Through-Hole Brick (DFM, 9-pin) - same Maxi Through-Hole Brick (DFM, 9-pin) - same Maxi Through-Hole Brick (DFM, 9-pin) - same
Input Voltage Range 250 V to 425 V (nominal 375 V) 250 V to 425 V 250 V to 425 V 250 V to 425 V 250 V to 425 V
Output Voltage 28 V 28 V 28 V 24 V 48 V
Output Power 600 W 600 W 600 W 600 W 600 W
Temperature Grade T (Industrial, -40C to +100C baseplate) T H (-40C to +125C) T T
Efficiency (typical) ~89% ~89% ~89% ~89% ~89%
Isolation Voltage 3000 VDC 3000 VDC 3000 VDC 3000 VDC 3000 VDC

关键差异点

  • Same-footprint temperature-grade upgrade path without PCB rework (对比 V375A28H600BL)
  • Same-family output voltage flexibility (对比 V375A24T600BL)
  • Isolated 600 W at 89% efficiency vs discrete flyback design (对比 Discrete 600 W isolated flyback at 375 V input)

设计说明

Estimated: at full 600 W load and ~89% efficiency the V375A28T600BL dissipates approximately 75 W through its aluminum baseplate. With T-grade derating the baseplate must stay below 100C, which in still air is impossible at full load - size a forced-air heatsink or cold-plate for at least 200-300 LFM airflow over the baseplate, or use Vicor's factory-fitted integrated heatsink option for the Maxi family. Do not use single-side FR4 PCB copper as the sole thermal path at this power level; the mechanical baseplate is required for cooling.

Lay out the host PCB with copper pours sized for the Vicor Maxi through-hole footprint: at least 2 oz copper on inner layers carrying the +IN/-IN and +OUT/-OUT nets, and keep high-current traces short and wide to minimize loop inductance. Because the isolation rating is 3000 VDC, maintain at least 6 mm of PCB creepage between primary (input) and secondary (output) copper. Mount the baseplate to a flat heatsink with thermal interface material (TIM) of 0.1 C/W or better, and torque the mounting hardware to Vicor's published value to avoid thermal resistance hot spots.

Do not connect input voltage above 425 V - the input stage has no transient suppression above its rated maximum. Add an upstream TVS or active clamp sized for the worst-case rectified mains surge, especially on 400 VAC industrial feeders where line transients can exceed 600 V transient peak. When configuring remote sense, route the +SENSE/-SENSE pairs tightly with the +OUT/-OUT leads; long sense wires can cause instability. Finally, confirm TRIM resistor placement if the output is being adjusted down, because exceeding TRIM range can cause output oscillation under light load.

Add an upstream inrush current limiter (NTC thermistor or active MOSFET precharge) sized for at least 50 A peak inrush - the internal input capacitance of the V375A28T600BL is substantial at 425 V maximum. Without precharge, the bulk capacitor can trigger the front-end circuit breaker or fuse on plug-in. For parallel-redundant operation, use Vicor's ORing controllers or external MOSFET ORing stages because these modules do not natively current-share without an external share-pin connection (not available on all Maxi suffixes - confirm in the datasheet for your suffix).

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

Compliance certifications were not present in the Verified Web Data. RoHS/REACH status and lead-free/halogen-free markings should be verified from the lot-specific Vicor datasheet addendum. AEC-Q100 is not applicable because this is a 600 W industrial-grade power module, not an automotive-qualified IC.

数据核验日期: 2026-10-14 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

V375A28T600BL datasheet V375A28T600BL price V375A28T600BL Vicor Maxi DC-DC isolated DC-DC converter 600W 28V 375V input Vicor Maxi brick through-hole DC-DC 600W 28V industrial bus power supply V375A28T600BL vs V375A24T600BL V375A28T600BL drop-in replacement buy V375A28T600BL online what is the input voltage of V375A28T600BL V375A28T600BL pinout diagram high voltage DC-DC 375V input to 28V output

相关元器件 & 术语

Vicor Corporation V375A28T600BL V375A28T600BN V375A28H600BL V375A24T600BL V375A48T600BL Maxi DC-DC Converter Isolated DC-DC module Through-hole brick module ZCS/ZVS topology VI-200 family Quarter-brick / half-brick / full-brick DFM package Industrial T-grade 3000 VDC isolation 28 VDC MIL-STD-704 bus 24 V industrial bus PLC power supply Photovoltaic inverter auxiliary rail Railway auxiliary converter (EN 50155) RoHS REACH IEC 61800-5-1 motor drive isolation IEC 62109-1 PV inverter safety IEC 62368-1 reinforced insulation
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情