An instrumentation amplifier is a differential-input amplifier optimized for measuring small signals superimposed on larger common-mode voltages. Its internal three-op-amp architecture provides matched input stages, high differential input impedance, accurate gain control, and strong common-mode rejection. This makes the INA2128 suitable for sensor interfaces where a low-level differential signal must be amplified accurately in the presence of substantial DC voltage, industrial noise, or ground-potential differences.
The INA2128 combines low offset and drift with a minimum 120 dB CMRR. Input overload protection extends to plus or minus 40 V, helping the amplifier tolerate accidental large input transients. Its supply range of 2.25 V to 18 V supports single-supply and dual-supply instrumentation systems. A single external resistor selects the gain, reducing the number of precision components needed for adjustable measurement channels.
The versatile three-op-amp design uses current-feedback input circuitry to preserve bandwidth at higher gains. According to the Texas Instruments datasheet, bandwidth remains 200 kHz at a gain of 100. This combination of precision DC behavior and usable high-gain bandwidth makes the device suitable for bridge sensors, current measurement, biomedical instrumentation, and industrial data-acquisition systems.
Typical uses include low-voltage pressure and strain-signal conditioning, thermocouple and RTD amplification, current-shunt measurement, battery-cell monitoring, and precision analog-front-end designs. The two-channel configuration is especially useful when a system must process two related sensor inputs while maintaining consistent gain-setting and supply architecture across both channels.
Choose gain resistors with suitable tolerance and temperature coefficient, and verify common-mode headroom at the lowest supply voltage. Input and reference pins require careful layout because leakage, parasitic resistance, and asymmetric copper can degrade CMRR. The gain-setting resistor should be placed close to the device, with symmetrical input routing where practical.
This product overview combines manufacturer specifications, package details, application guidance, and drop-in replacement information to support faster component selection and PCB planning. It also identifies the trade-offs involved when changing amplifier families, including gain range, bandwidth, offset performance, supply voltage, and protection requirements.
بدائل مباشرة لـ INA2128UA — نفس الحزمة، متوافق دبوس بدبوس. تُستثنى القطع ذات الحزم المختلفة التي تتطلب تعديل PCB.
الطرازات في هذه السلسلة
طرازات من نفس السلسلة متوافقة تمامًا مع INA2128UA (نفس عامل الشكل والبصمة) — يختلف في Package.
INA2128U
✅ بديل مباشرتواصل لمعرفة السعر
عرض ورقة البيانات ←INA2128UA-1
✅ بديل مباشر📋 بديل مرجعي (غير موجود في الكتالوج)
INA2128UA الحدود القصوى والخصائص الكهربائية
| Amplifier Type | Dual instrumentation amplifier |
| Number of Channels | 2 channels |
| Gain Range | 1 to 10,000 |
| Gain Setting Method | 1 external resistor |
| Bandwidth at Gain 100 | 200 kHz |
| Maximum Offset Voltage | 50 uV |
| Maximum Offset Drift | 0.5 uV/degree C |
| Maximum Input Bias Current | 5 nA |
| Minimum Common-Mode Rejection | 120 dB |
| Input Overload Protection | plus or minus 40 V |
| Supply Voltage Range | 2.25 V to 18 V |
| Internal Architecture | 3-op-amp design |
| Input Circuitry | Current-feedback |
| العلبة | 16-pin SOIC (DW) |
| نوع التركيب | Surface mount |
دليل تكوين أطراف INA2128UA 16-pin soic (dw)
تكوين الأطراف لـ INA2128UA (حزمة 16-pin soic (dw)). يتميز هذا المكوّن التناظري بأطراف الإدخال والإخراج وإمداد الطاقة. راجع ورقة بيانات الشركة المصنعة لتكوينات طرف إلغاء الإزاحة والتعويض والتمكين. مثالي لدوائر تكييف الإشارة والمضخمات.
لا تتوفر بيانات مفصلة لمخطط التوصيلات لـ INA2128UA.
راجع ورقة البيانات للحصول على تكوين الأطراف الكامل.
التطبيقات النموذجية
INA2128UA مناسب لـ 6 التطبيقs: Strain-Gauge Bridge Measurement, Current-Shunt Monitoring, Battery-Cell Voltage Acquisition, Precision Pressure Sensor Interface, Biomedical Sensor Signal Conditioning, Industrial Data Acquisition.
Strain-Gauge Bridge Measurement
The INA2128UA fits strain-gauge and resistive bridge front ends that produce small differential signals on a substantial common-mode voltage. Its two independently adjustable channels can process complementary bridge outputs or two related sensing elements, while the 1 to 10,000 gain range accommodates both millivolt-level and low-level volt signals. Maximum offset voltage of 50 uV and maximum drift of 0.5 uV/degree C help stabilize measurements over temperature, and 120 dB minimum CMRR suppresses common-mode excitation and coupled industrial noise. Gain is established with one resistor, allowing the design to use matched high-precision resistors while retaining a straightforward calibration structure.
موصى به
Current-Shunt Monitoring
The INA2128UA is appropriate for bidirectional or unidirectional current measurement using a low-ohm shunt in the high-current path. Its maximum input bias current of 5 nA limits the error introduced into high-impedance sensing nodes, while plus or minus 40 V input protection improves tolerance of transient voltage during fault conditions. Two channels allow simultaneous measurement of two shunt sections or power-rail currents, and gains up to 10,000 provide useful amplification for low-value shunts. The 200 kHz bandwidth at gain 100 permits measurement of current waveforms beyond static DC without requiring a higher-speed alternative.
موصى به
Battery-Cell Voltage Acquisition
The dual-channel INA2128UA can monitor adjacent battery cells or divided high-voltage bus sections in a battery-management system. Its 2.25 V to 18 V supply range supports low-voltage sensing rails, and the 120 dB minimum common-mode rejection helps isolate small voltage differences from the much larger potential shared by series-connected cells. Maximum offset of 50 uV and drift of 0.5 uV/degree C are particularly valuable when accurate cell balancing depends on measuring small voltage differences. The two-channel architecture reduces the number of separate amplifiers needed for redundant or differential cell measurements.
موصى به
Precision Pressure Sensor Interface
The INA2128UA supports pressure and force sensors that generate a differential millivolt output on a common-mode baseline. The 5 nA maximum input bias current minimizes loading of high-impedance sensor outputs, and the 50 uV maximum offset reduces errors in pressure readings that depend on detecting small differential signals. Adjustable gains from 1 to 10,000 allow the same amplifier family to serve different sensor sensitivities. With 200 kHz bandwidth at gain 100, the device can also handle dynamic pressure events while retaining low DC error for static measurements.
موصى به
Biomedical Sensor Signal Conditioning
The INA2128UA can condition low-amplitude differential signals from biomedical and diagnostic sensors where offset, drift, and common-mode rejection determine measurement quality. Its 50 uV maximum offset and 0.5 uV/degree C maximum drift limit temperature-dependent baseline errors, while 120 dB minimum CMRR helps reject mains-coupled interference and body-coupled common-mode voltage. The dual-channel configuration supports two sensors or a differential and reference channel. Plus or minus 40 V input protection is useful for robust connector interfaces, provided signal amplitude and duration remain within the device's absolute-maximum ratings.
موصى به
Industrial Data Acquisition
The INA2128UA is well suited to industrial data-acquisition modules that combine slow precision measurements with occasional higher-bandwidth signals. Two channels support redundant sensors, bridge measurements, or gain stages feeding multiplexed converters, while the 120 dB minimum CMRR reduces errors from long cables and grounded machinery. The 200 kHz bandwidth at gain 100 provides useful signal bandwidth, and gain selection through one external resistor simplifies calibration across multiple board variants. Plus or minus 40 V input protection improves robustness at connector-exposed inputs, although protection-network design must preserve accuracy and bandwidth.
موصى به
ملخص المنتجات الموصى بها
بيانات مرجعية هندسية لـ INA2128UA — المقارنة وإرشادات التصميم ومعلومات الامتثال.
دليل الاختيار
المقارنة مع البدائل
| المعامل | هذا المنتج | INA2128U | INA2128UA-1 |
|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | SOIC-16 (DW) | SOIC-16 (DW) | SOIC-16 (DW) |
| Channel Count | 2 channels | 2 channels | 2 channels |
| Gain Range | 1 to 10,000 | 1 to 10,000 | 1 to 10,000 |
| Bandwidth at Gain 100 | 200 kHz | 200 kHz | 200 kHz |
| Supply Voltage Range | 2.25 V to 18 V | 2.25 V to 18 V | 2.25 V to 18 V |
| Input Protection | plus or minus 40 V | plus or minus 40 V | plus or minus 40 V |
أبرز الفروقات
- High accuracy for low-level differential measurements (مقابلINA2128U)
- Dual-channel instrumentation amplification (مقابلINA2128U)
- Strong common-mode rejection (مقابلINA2128UA-1)
ملاحظات التصميم
Keep the gain-setting resistor close to the INA2128UA gain pin, and route each input channel symmetrically. Use a common ground reference for both amplifier channels and avoid placing long, high-impedance input traces next to switching nodes. Refer to the manufacturer datasheet pin-description and application diagrams when assigning the 16-pin SOIC connections.
Do not assume the input-protection rating changes the normal operating range. The plus or minus 40 V protection rating describes tolerance of input voltage, while valid measurement operation still requires compliance with the specified common-mode and absolute-maximum limits. Also verify output swing at the selected supply voltage before choosing a gain that could saturate the amplifier.
For maximum CMRR, use equal input impedance and matched resistor networks on both sides of each differential input. Keep leakage from PCB contamination and flux residue under control because the 5 nA maximum input bias current makes high-impedance nodes sensitive to contamination. A protective resistor can limit transient current, but its value should preserve bandwidth and input impedance at the intended gain.
Place input and reference components adjacent to their corresponding pins, with the shortest practical return path to the exposed supply and ground structure. The SOIC-16 package benefits from stable ground-plane continuity beneath the device. Avoid adding test-point loops that increase parasitic capacitance on high-gain input nodes, particularly when 200 kHz bandwidth at gain 100 is a system requirement.
معلومات الامتثال